• 제목/요약/키워드: Maximum Response Acceleration

검색결과 224건 처리시간 0.029초

지반변동성을 고려한 액상화 진동전단응력비의 확률론적 해석 (Probabilistic Analysis of Liquefaction Cyclic Stress Ratio Considering Soil Variability)

  • 허준
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.95-101
    • /
    • 2018
  • The objective of this study is to evaluate the liquefaction cyclic shear stress ratio considering the soil uncertainty. In this study, the probabilistic ground response analysis and the cyclic shear stress ratio analysis for the liquefaction potential evaluation are performed considering the soil variability. The statistical properties of input ground parameters were analyzed to investigate the parameters affecting the seismic response analysis. The Probabilistic analysis was carried out by Monte Carlo Simulation method. The ground response analysis was performed considering the soil variability and the probability distribution characteristics of the ground acceleration. The probability distribution of the peak ground acceleration by seismic characteristics was presented. The differences of liquefaction shear stress ratio results according to soil variability were compared and analyzed. The maximum acceleration of the ground by the deterministic method was analyzed to be overestimation of the ground amplification phenomenon. Also, the shear stress ratio was overestimated.

탄소성 응답스펙트럼의 일반적인 성질에 대하여 (The General Characteristic of Elastic-Plastic Spectra)

  • 전규식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.233-240
    • /
    • 1997
  • Seven kinds of hysteric model were used and classified three groups considering the absorbing capacities of strain energy for each model. Four kids of each model. Four kinds of strong motion earthquake record (two of them were recorded in Japan and the others in U.S.A) are used. The yield strength of building was set in the ratio to the maximum input acceleration (Yield Strength / Maximum Acceleration = 0.5~3.0). Natural periods of structures were varied 0.1~3.0 second with an interval of 0.1 second. First group : Elastic-Plastic model, Ramberg-Osgood model Second group : Degrading Tri-liner model, Takeda model Third group : Slip model, Origin model, Max-D model Elastic-plastic response spectra were calculated for response velocities, displacement, energy input, ductility factors, accumulated ductility factors. The equivalent response values of M.D.O.F systems against S.D.O.F system were calculated to compare the relationship of two systems.

  • PDF

쇄석 띠기초와의 거리에 따른 주변지반의 가속도 변화 (Acceleration Variation of Surrounding Ground according to distance from Strip-Type Crushed Stone Foundation)

  • 손수원;손태익;김수봉;김진만
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.217-223
    • /
    • 2019
  • 국내외에서 점토층이나 준설토 등이 있는 연약지반을 개량하고, 그 지반위에 구조물을 건설하는 수요는 점차적으로 늘어나고 있다. 그리고 이러한 개발과 더불어 태풍, 산사태, 지진 등과 같은 자연재해의 빈도와 규모도 증가하고 있다. 이러한 자연재해로 인한 피해를 예방하기 위한 방법 중 하나가 지반개량공법이다. 본 연구에서는 쇄석을 띠기초 형식으로 설치하였을 때의 주변지반의 가속도 변화를 1-G 진동대 실험을 이용하여 분석하였다. 점토를 이용하여 지반을 조성하고 기초는 쇄석을 띠형식으로 설치하였다. 주기가 다른 입력지진파에 대해 응답가속도와 응답스펙트럼을 분석하였다. 쇄석 띠기초와의 인접거리에 따른 가속도 변화를 분석하여 지진시 쇄석 띠기초가 주변지반의 가속도 변화에 미치는 영향을 평가하였다. Hachinohe 지진파 결과에서는 쇄석띠기초와의 거리에 비해 가속도가 큰 감소는 없지만, 두가지 지진파에 대한 최대응답가속도가 쇄석띠기초와의 거리에 반비례하였다. 응답스펙트럼 분석결과, 장주기와 단주기 입력파에서의 감쇠되는 주기가 달랐으며, 이와 같은 응답스펙트럼 변화가 가속도의 최대가속도값에 영향을 준 것으로 판단된다. Hachinohe 지진파에서는 쇄석띠기초와 멀어질수록 0.08~0.5초 사이의 주기에서 감쇠가 컸으며, Northridge 입력파에서는 쇄석띠기초와 멀어질수록 0.2초 이내의 주기에서 감쇠가 컸다.

지진격리교량의 지진해석을 위한 인공지진파의 작성 (Generation of artificial earthquake time histories for the seismic analysis of base-isolated bridges)

  • 김남식;김재민;이계희;강형택
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.487-494
    • /
    • 2005
  • In this study, a set of artificial earthquake time histories, which can be used for the earthquake-resistant design of seismically isolated highway bridges, was presented. In addition, adequateness of the generated ground accelerations was investigated. These were performed based on the seismic design standard for seismically isolated bridges. Total of 22 acceleration time histories were generated for each soil condition by the spectral method. The time histories were verified to meet the code provisions including (1) mean response spectrum at control frequencies, (2) EPGA (effective peak ground acceleration), and (3) correlation coefficient. Finally, the maximum response corresponding to four time histories and the mean response associated with seven time histories were computed using the generated acceleration time histories, which shows validity of the proposed artificial earthquake time histories.

  • PDF

경부고속철도 교량의 과도한 가속도의 저감방안에 대한 연구 (A Study on the Solution of Excessive Accelerations on the Bridge for Gyeongbu High-speed Railway)

  • 곽종원;진원종;최은석;조정래;이정우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.477-485
    • /
    • 2007
  • When Korean High Speed Train (KTX) runs over a high-speed railway bridge, the high-speed railway bridge gives quite large acceleration response. Local vibration at the large cross section, the impact from equally spaced sleepers, the vibration due to elastomeric bearings, and the vibration from the train itself are the causes of this acceleration response. Maximum peaks of the accelerations measured at the bridges are sometimes going over the limit value. Although it is smaller than 0.35G, the limit from the Korean Bridge Design Manual(BRDM), this acceleration response should be reduced for the safety of running trains with high speed. In this paper, to reduce the acceleration response by controlling excessive local vibration at the large cross section, vibration reduction method is studied. The result shows that the effect of elastomeric bearings on the vibration of the bridge is very large and that the vibration reduction device is effective against wing mode local vibration PSC box girder bridge for the high-speed railway, which usually has very large cross section, although it has little effect on global vibration modes such as flexural and twisting modes. The test of the vibration reduction device on the bridge in service has been performed in this study.

  • PDF

Generation of critical and compatible seismic ground acceleration time histories for high-tech facilities

  • Hong, X.J.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제26권6호
    • /
    • pp.687-707
    • /
    • 2007
  • High-tech facilities engaged in the production of semiconductors and optical microscopes are extremely expensive, which may require time-domain analysis for seismic resistant design in consideration of the most critical directions of seismic ground motions. This paper presents a framework for generating three-dimensional critical seismic ground acceleration time histories compatible with the response spectra specified in seismic design codes. The most critical directions of seismic ground motions associated with the maximum response of a high-tech facility are first identified. A new numerical method is then proposed to derive the power spectrum density functions of ground accelerations which are compatible with the response spectra specified in seismic design codes in critical directions. The ground acceleration time histories for the high-tech facility along the structural axes are generated by applying the spectral representation method to the power spectrum density function matrix and then multiplied by envelope functions to consider nonstationarity of ground motions. The proposed framework is finally applied to a typical three-story high-tech facility, and the numerical results demonstrate the feasibility of the proposed approach.

Mitigation of seismic responses of actual nuclear piping by a newly developed tuned mass damper device

  • Kwag, Shinyoung;Eem, Seunghyun;Kwak, Jinsung;Lee, Hwanho;Oh, Jinho;Koo, Gyeong-Hoi
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2728-2745
    • /
    • 2021
  • The purpose of this study is to reduce seismic responses of an actual nuclear piping system using a tuned mass damper (TMD) device. A numerical piping model was developed and validated based on shaking table test results with actual nuclear piping. A TMD for nuclear piping was newly devised in this work. A TMD shape design suitable for nuclear piping systems was conducted, and its operating performance was verified after manufacturing. The response reduction performance of the developed TMD under earthquake loading on actual piping was investigated. Results confirmed that, on average, seismic response reduction rates of 34% in the maximum acceleration response, 41% in the root mean square acceleration response, and 57% in the spectral acceleration response were shown through the TMD application. This developed TMD operated successfully within the seismic response reduction rate of existing TMD optimum design values. Therefore, the developed TMD and dynamic interpretation help improve the nuclear piping's seismic performance.

Seismic microzonation of Kolkata

  • Shiuly, Amit;Sahu, R.B.;Mandal, Saroj
    • Geomechanics and Engineering
    • /
    • 제9권2호
    • /
    • pp.125-144
    • /
    • 2015
  • This paper presents the probabilistic seismic microzonation of densely populated Kolkata city, situated on the world's largest delta island with very soft alluvial soil deposit. At first probabilistic seismic hazard analysis of Kolkata city was carried out at bedrock level and then ground motion amplification due to sedimentary deposit was computed using one dimensional (1D) wave propagation analysis SHAKE2000. Different maps like fundamental frequency, amplification at fundamental frequency, peak ground acceleration (PGA), peak ground velocity (PGV), peak ground displacement (PGD), maximum response spectral acceleration at different time period bands are developed for variety of end users, structural and geotechnical engineers, land use planners, emergency managers and awareness of general public. The probabilistically predicted PGA at bedrock level is 0.12 g for 50% exceedance in 50 years and maximum PGA at surface level it varies from 0.095 g to 0.18 g for same probability of exceedance. The scenario of simulated ground motion revealed that Kolkata city is very much prone to damage during earthquake.

Conceptual Design and Wind Load Analysis of Tall Building

  • Lee, S.L.;Swaddiwudhipong, S.
    • Computational Structural Engineering : An International Journal
    • /
    • 제1권1호
    • /
    • pp.11-20
    • /
    • 2001
  • The paper describes the conceptual design, structural modelling and wind load analysis of tall buildings. The lateral stiffness of the building can be obtained economically through the interaction of core walls with peripheral frame tube and/or bundle of frame tubes and integrated design of the basement. The main structural components should be properly distributed such that the building will deflect mainly in the direction of the applied force without inducing significant response in other directions and twist. The cost effectiveness can be further enhanced through close consultation between architects and engineers at an early stage of conceptual design. Simplified structural modelling of the building and its response in three principal directions due to wind load are included. Effects of the two main structural components on the performances of a 70-story reinforced concrete building in terms of peak drift and maximum acceleration under wind load are discussed.

  • PDF

Investigating the dynamic response of deep soil mixing and gravel drain columns in the liquefiable layer with different thickness

  • Gholi Asadzadeh Khoshemehr;Hadi Bahadori
    • Geomechanics and Engineering
    • /
    • 제34권6호
    • /
    • pp.665-681
    • /
    • 2023
  • Liquefaction is one of the most devastating geotechnical phenomena that severely damage vital structures and lifelines. Before constructing structures on problematic ground, it is necessary to improve the site and solve the geotechnical problem. Among ground improvement methods dealing with liquefaction, gravel drain (GD) columns and deep soil mixing (DSM) columns are popular. In this study, the results of a series of seismic experiments in a 1g environment on a structure located over liquefiable ground with different thicknesses reinforced with GD and DSM techniques were presented. The dynamic response of the reinforced ground system was investigated based on the parameters of subsidence rate, excess pore water pressure ratio, and maximum acceleration. The time history of the input acceleration was applied harmonically with an acceleration range of 0.2g and at frequencies of 1, 2, and 3 Hz. The results show that the thickness of the liquefiable layer and the frequency of the input motion have a significant impact on the effectiveness of the improvement method and all responses. Among the two techniques used, DSM in thick liquefied layers was much more efficient than GD in controlling the subsidence and rupture of the soil under the foundation. Maximum settlement values, settlement rate, and foundation rotation in the thicker liquefied layer at the 1-Hz input frequency were higher than at other frequencies. At low thicknesses, the dynamic behavior of the GD was closer to that of the DSM.