• Title/Summary/Keyword: Matrix Capacity Rate

Search Result 73, Processing Time 0.021 seconds

MIMO Channel Capacity and Configuration Selection for Switched Parasitic Antennas

  • Pal, Paramvir Kaur;Sherratt, Robert Simon
    • ETRI Journal
    • /
    • v.40 no.2
    • /
    • pp.197-206
    • /
    • 2018
  • Multiple-input multiple-output (MIMO) systems offer significant enhancements in terms of their data rate and channel capacity compared to traditional systems. However, correlation degrades the system performance and imposes practical limits on the number of antennas that can be incorporated into portable wireless devices. The use of switched parasitic antennas (SPAs) is a possible solution, especially where it is difficult to obtain sufficient signal decorrelation by conventional means. The covariance matrix represents the correlation present in the propagation channel, and has significant impact on the MIMO channel capacity. The results of this work demonstrate a significant improvement in the MIMO channel capacity by using SPA with the knowledge of the covariance matrix for all pattern configurations. By employing the "water-pouring algorithm" to modify the covariance matrix, the channel capacity is significantly improved compared to traditional systems, which spread transmit power uniformly across all the antennas. A condition number is also proposed as a selection metric to select the optimal pattern configuration for MIMO-SPAs.

An Experimental Study on the Rotary Regenerator for Air Conditioning according to Variable Inlet Conditions (흡기조건의 변화에 따른 공기조화용 회전재생기에 관한 실험적 연구)

  • 이태우;조진호;서정일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.422-429
    • /
    • 1990
  • The experimental study investigates two aspects of counterflow sensible heat regenerator operation. First, it examines the regenerator performance in periodic steady state operation with spatially nonuniform inlet temperature in one of the fluid stream. Second, the study examines the transient response of a regenerator to a step change in the inlet temperature of one of the fluid streams. The effect of transient inlet temperatures is analyzed in terms of the response of the outlet fluid temperatures to a step change in temperature of one of the inlet fluid streams. The effect of temperature nonuniformities is analyzed in terms of the change of temperature nonuniformities is analyzed in terms of the change in steady state effectiveness due to a circumferential temperature distribution in one of the inlet fluid streams. an experimental analysis has been conducted using a counterflow, parallel passage, and rotary regenerator made from polyethylene film. Efficiencies follow similar trends with increasing matrix to fluid capacity rate ratio for the balanced and symmetric regenerator with nonuniform inlet temperature.

Strain Rate Effect on the Compressive and Tensile Strength of Hooked Steel Fiber and Polyamide Fiber Reinforced Cement Composite (변형 속도에 따른 후크형 강섬유 및 폴리아미드섬유보강 시멘트 복합체의 압축 및 인장강도 특성)

  • Kim, Hong-Seop;Kim, Gyu-Yong;Lee, Sang-Kyu;Son, Min-Jae;Nam, Jeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.3
    • /
    • pp.76-85
    • /
    • 2017
  • In this study, to evaluate the mechanical properties of fiber-reinforced cement composites by strain rate, hydraulic rapid loading test system was developed. And compressive and tensile strength of the hooked steel fiber and polyamide fiber reinforced cement composite were evaluated. As a result, the compressive strength, strain capacity and elastic modulus were increased with increasing strain rate. The effect of compressive strength by type and volume fraction of fibers was not significant. The dynamic increase factor(DIF) of the compressive strength was higher than that of the CEB-FIP model code 2010 and showed a trend similar to that of ACI-349. The tensile strength and strain capacity were increased with increasing strain rate. The hooked steel fibers were drawn from the matrix. The tensile strength and strain capacity of hooked steel fiber reinforced cement composites were increased as the strain rate increased. The tensile strength and deformation capacity of the fiber reinforced cement composites were increased. And, hooked steel fibers were drawn from the matrix. On the other hand, because the bonding properties of polyamide fiber and matrix is large, polyamide fiber was cut-off with out pullout from matrix. The strain rate effect on the tensile properties of polyamide fiber reinforced cement composites was found to be strongly affected by the tensile strength of the fibers.

Theoretical Analysis of a Rotary Heat Exchanger Based on a Simplified Model (단순모델에 의한 회전형 열교환기 이론해석)

  • Son, Sung Gyun;Kim, Yongchan;Lee, Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.8
    • /
    • pp.409-417
    • /
    • 2015
  • A simplified rotary heat-exchanger model was developed with an assumption of a linear temperature distribution along the flow direction. Based on the model, the exact fluid solution and solid temperature variations were obtained and verified from a comparison with previous numerical studies. The heat transfer in the rotary heat exchanger was investigated using the theoretical solutions. The heat exchanger's effectiveness was shown to be saturated, with a rotational-speed increase that is higher than a critical value that is solely dependent on the thermal capacity of the solid matrix but independent of the fluid flow rate; the saturated value of the effectiveness was determined only by the NTU of the heat exchanger. Where the thermal diffusivity of the solid matrix is so slight that the thermal penetration depth becomes smaller than the matrix thickness, the effective thermal capacity of the solid matrix decreased according to the penetration depth.

Triangulation Algorithm for Multi-user Spatial Multiplexing in MIMO Downlink Channels (MIMO 다운링크 채널에서 다중사용자 공간다중화를 위한 알고리즘)

  • Lee, Heun-Chul;Paulraj, Aroyaswami;Lee, In-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.1C
    • /
    • pp.45-54
    • /
    • 2010
  • This paper studies the design of a multiuser multiple-input multiple-output (MIMO) system, where a base station (BS) transmits independent messages to multiple users. The remarkable "dirty paper coding (DPC)" result was first presented by Costa that the capacity does not change if the Gaussian interference is known at the transmitter noncausally. While several implementable DPC schemes have been proposed recently for single-user dirty-paper channels, DPC is still difficult to implement directly in practical multiuser MIMO channels. In this paper, we propose a network channel matrix triangulation (NMT) algorithm for utilizing interference known at the transmitter. The NMT algorithm decomposes a multiuser MIMO channel into a set of parallel, single-input single-output dirty-paper subchannels and then successively employs the DPC to each subchannel. This approach allows us to extend practical single-user DPC techniques to multiuser MIMO downlink cases. We present the sum rate analysis for the proposed scheme. Simulation results show that the proposed schemes approach the sum rate capacity of the multiuser MIMO downlink at moderate signal-to-noise ratio (SNR) values.

The Microstructure and the Electrochemical Characteristics of Zr based Zr-V-Mn-Ni Laves Phase Alloy (Zr-V-Mn-Ni계 라브스상 합금의 미세 구조와 전기 화학적 특성)

  • Jeong, Chigyu;Han, Dongsoo;Chung, Wonsub;Kim, Ingon;Kim, Wonbaek
    • Journal of Hydrogen and New Energy
    • /
    • v.8 no.3
    • /
    • pp.121-129
    • /
    • 1997
  • $ZrV_{0.1}Mn_{0.7}Ni_{1.2}$ alloy ingot (bulk alloy) made by the arc melting was found to be consisting of mostly of $ZrV_{0.2}Mn_{0.98}Ni_{1.04}$ matrix alloy and $ZrV_{0.01}Mn_{0.13}Ni_{1.2}$ 2nd phase alloy. The former alloy had the form of the C15 type Laves alloy structure and the latter one had the intermetallic compound structure of $Zr_9Ni_{11}$. In order to investigate the effect of these two phases on the electrochemical charge-discharge characteristics of bulk $ZrV_[0.1}Mn_0.7}Ni_{1.2}$ alloy, the matrix and the 2nd phase alloys were fabricated separately by arc melting method and their electrochemical characteristics were studied and compared with the bulk alloy. It was found that the discharge capacity was the lowest of 160 mAh/g in the 2nd phase alloy. The matrix alloy exhibited 200 mAh/g. Both were lower than that of the bulk alloy of 250 mAh/g. The matrix and the bulk alloys showed a similar properties in the activation stage, the high rate dischargeability and the self discharge characteristics. Also a signigicant capacity decrease was observed after activation in both alloys. Whereas the 2nd phase alloy showed the very different characteristics. This alloy was found to be difficult to activate. However the capacity was remained constant after the activation. Also the self discharge rate was seen to be better than those of the matrix and the bulk alloys.

  • PDF

Effect of Strain Rate on Tensile Behavior of Hybrid Fiber Reinforced Cement-based Composites (하이브리드 섬유보강 시멘트복합체의 인장거동에 미치는 변형속도의 영향)

  • Son, Min-Jae;Kim, Gyu-Yong;Lee, Bo-Kyeong;Lee, Sang-Kyu;Kim, Gyeong-Tae;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.122-123
    • /
    • 2017
  • In this study, the tensile behavior of single and hybrid fiber reinforced cement composite according to strain rate was evaluated. Experimental results, in the strain rate 10-6/s, fiber reinforced cement composite showed improved of tensile strength and decrease of strain at peak stress as SSF volume content increased. In the strain rate 101/s, the single and hybrid reinforced cement composite' s tensile properties are improved, because of the improved bond strength between the fiber and matrix. And hybrid fiber reinforced cement composite showed high energy absorption capacity, because the SSF prevented the cracking and fracture of the surrounding matrix when during the HSF pull-out.

  • PDF

Strain Rate Effect on the Tensile Properties of Steel Fiber Hybrid Reinforced Cement Composites (강섬유를 하이브리드 보강한 섬유보강 시멘트복합체의 인장특성에 미치는 변형속도의 영향)

  • Kim, In-Ho;Kim, Gyu-Yong;Lee, Sang-Kyu;Son, Min-Jae;Kim, Gyeong-Tae;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.87-88
    • /
    • 2018
  • In this study, the tensile properties of single and hybrid fiber reinforced cement composite according to strain rate was evaluated. Experimental results, in the strain rate 10-6/s, fiber reinforced cement composite showed improved of tensile strength and decrease of strain at peak stress as SSF volume content increased. In the strain rate 101/s, the single and hybrid reinforced cement composite's tensile properties are improved, because of the improved bond strength between the fiber and matrix. And hybrid fiber reinforced cement composite showed high energy absorption capacity, because the SSF prevented the cracking and fracture of the surrounding matrix when during the HSF pull-out.

  • PDF

The effect of Ni content on the discharge characteristics of Zr-V-Mn-Ni hydrogen storage alloy electrode (Zr-V-Mn-Ni 수소저장합금전극의 방전특성에 미치는 Ni 양의 효과에 관한 연구)

  • Lee, Sang-Min;Kim, Dong-Myung;Jung, Jae-Han;Lee, Jai-Young
    • Journal of Hydrogen and New Energy
    • /
    • v.8 no.1
    • /
    • pp.11-21
    • /
    • 1997
  • $ZrV_{0.7}Mn_{0.5}Ni_{1.2}$ alloy is attractive for anode material in Ni/MH secondary battery because of its large hydrogen storage capacity in gas-solid reaction and long cycling durability in KOH electrolyte. In this work, in order to further improve the discharge performance of this alloy electrode, the alloy was annealed by optimal condition which is for 12 hours at $1000^{\circ}C$. The alloy annealed under optimal condition had higher rate capability and discharge capacity than as-cast one. The microstructure of the as-cast and annealed alloy was investigated by scanning electron microscopy and energy dispersive spectroscopy. Ni content in the matrix was increased, being this homogenized after annealing. Additionally, The measurement of the surface area by B.E.T. analysis showed that there was little difference as-cast and annealed alloy. Therefore, improvement in the rate capability of the annealed alloy is due to increase of Ni content in the matrix.

  • PDF

Wear Properties of Epoxy Matrix Nanocomposites (에폭시 기지 나노복합재료의 마모 특성)

  • Kim, J.D.;Kim, H.J.;Koh, S.W.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.83-88
    • /
    • 2010
  • The wear behavior of epoxy matrix composites filled with nano sized silica particles is discussed in this paper. Especially, the variation of the coefficient of friction and the wear resistance according to the change of apply load and sliding velocity were investigated for these materials. Wear tests of pin-on-disc mode were carried out and the wear test results exhibited as following ; The epoxy matrix composites showed lower coefficient of friction compared to the neat epoxy through the whole sliding distance. As increasing the sliding velocity the epoxy matrix composites indicated lower coefficient of friction, whereas the neat epoxy showed higher coefficient of friction as increasing the sliding velocity. The specific friction work of both materials were increased with apply load. In case of the epoxy matrix composites, the running in periods of friction were reduced as increase in apply load. The epoxy matrix composites were improved the wear resistance by adding the nano silica particles remarkably. It is expected that the load carrying capacity of the epoxy matrix composites will be improved by increase of Pv factor.