• 제목/요약/키워드: Materials of insole

검색결과 11건 처리시간 0.03초

초다공성 에어로젤 함유 섬유상 복합체를 이용한 신발 안창소재에 관한 연구 (Study on Ultra Porous Aerogel/fiber Composite for Shoe Insole)

  • 오경화;박순자
    • 한국의류학회지
    • /
    • 제33권5호
    • /
    • pp.701-710
    • /
    • 2009
  • This study was conducted to develop excellent insole with good thermal insulation using new materials. We investigated that aerogel/fiber composite can be used as padding materials of shoes by comparing surface shape, moisture regain, water vapor permeability, thermal insulation and compression rate of insole materials tried with nonwoven fabric padding materials and insole sold in market. The results are as follows. Surface shapes were shown that the most appropriate material for sealing aerogel/fiber composite was high density fabric as per size of particle of aerogel. Moisture regain of aerogel/fabric composite was better than nonwoven fabric padding samples. However, when compared to insole sold in market, its moisture regain was worse than those of insole merchandises. Water vapor permeability was higher in material padded with nonwoven fabric than materials padded with aerogel/fiber composite in all three kinds of sealing fabrics. Thermal conductivity of aerogel/fabric composite was lower than nonwoven fabric material regardless of sealing fabrics. Thermal insulation of aerogel/fiber composite was higher than padding material of nonwoven fabric regardless of sealing fabrics. Compression rate of nonwoven (SP1) was higher than that of aerogel/fiber composite (SP2). Compressive elastic recovery rate of SP1 was also higher than that of SP2, which its compression rate and compressive elastic recovery rate were both poor. As the above result, ultra porous aerogel/fiber composite were proved to be material of good thermal insulation with lower thermal conductivity and also compression rate was proved to be low. Therefore, we can say that aerogel/fiber composite have high possibility to be used as insole materials for cold winter shoes requiring good thermal insulation protection.

층간소음 방지를 위한 인솔 재질별 진동 및 소음 평가 (Analyzing the Effect of Insole Materials on Vibration and Noise Reduction between Floors)

  • 민승남;이희란
    • 한국의류학회지
    • /
    • 제47권1호
    • /
    • pp.110-122
    • /
    • 2023
  • The COVID-19 pandemic increased people's time at home and caused an 80% increase in noise disputes between floors. The purpose of this study is to propose suitable materials for making indoor shoes (insoles) to minimize noise between floors. Subjects without back pain and leg-related disease (e.g. arthritis, etc.) from three different age groups (childhood, adolescence, and adulthood) were recruited for the study. Five polymer insole materials were considered: Chloroprene Rubber (CR foam), Ethylene Propylene Diene Monomer (EPDM foam), Natural Latex foam, Ethylene Vinyl Acetate (EVA foam), and Polyurethane (PU foam). From these materials, 20 combinations were prepared and randomly tested for noise and vibration. The results revealed a significant difference in noise and vibration levels based on the type of material used and the age of the subject. Nevertheless, all materials under consideration successfully reduced noise and vibration; in particular, type A-C greatly decreased. The CR foam material was especially effective at noise and vibration reduction (p<.01). This study suggests that adding insoles into socks that children wear at home could reduce noise vibration and disputes between floors.

소아 편평족 환자에서 Pressure Based Customized 3-Dimensional Printing Insole의 유용성 (Effect of Pressure Based Customized 3-Dimensional Printing Insole in Pediatric Flexible Flat Foot Patients)

  • 이시욱;최정훈;권혁준;송광순
    • 대한족부족관절학회지
    • /
    • 제24권3호
    • /
    • pp.113-119
    • /
    • 2020
  • Purpose: A flatfoot that fails to form a longitudinal foot arch is a common lower limb deformity in children. This study evaluated the structural and functional effects of the insole for pediatric flexible flat foot (PFFF). Materials and Methods: Twenty-nine PFFF patients (20 boys and 9 girls, 58 feet) with bilateral symptomatic flatfoot deformities between February 2017 and May 2019 were included in this study. Sixteen patients (32 cases, study group) were treated with a pressured based 3-dimensional printing insole, and 13 patients (26 cases, control group) were followed up regularly without any treatment. Flatfoot was diagnosed by a lateral talo-first metatarsal angle of more than 4° in convex downward and talocalcaneal angles of more than 30° and a calcaneal pitch of less than 20°. The foot pressures, including the midfoot pressure, total foot pressure, and the ratio of the midfoot pressure to the total foot pressure, were evaluated by pedobarography. The clinical scores were assessed using the visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS), and Pediatrics Outcomes Data Collection Instrument (PODCI) scores. Results: The mean age of the study group was 9.16 years, and the mean age of the control group was 7.73 years. The mean follow-up period was 16 months. The change in the lateral talocalcaneal angle was -4.664°±1.239° in the study group and -0.484°±1.513° in the control group. A significant difference in the amount of change of the lateral talocalcaneal angle was observed between the two groups (p=0.034). The midfoot pressures were similar in the two groups. Conclusion: Pressure based customized 3-dimensional printing insole in PFFF may have some effect on the hindfoot bony alignment, but it does not affect the changes in midfoot pressure.

당뇨화 다밀도 안창의 충격특성 (Impact Characteristics of Multi-Density Insoles for DM Shoes)

  • 금영광;정임숙;강성재;김영길;김명웅;김영호
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.31-36
    • /
    • 2003
  • 본 논문에서는 일정한 충격하중을 제공하여 충격특성을 정량적으로 측정할 수 있는 시스템을 개발하고 당뇨화 안창의 소재에 대한 감쇠지수, 중앙주파수, 반발계수 등을 통하여 6종류의 당뇨화 소재와 3종류의 다밀도 당뇨화 안창의 충격특성을 측정하였다. Podian, Plastazote black, Plastazote white, Flexible PU foam, Podialene 200 blue, Podia flex 소재 중에서 감쇠지수와 반발계수는 Podian이 우수하였으며, Flexible PU foam 소재의 중앙주파수가 가장 작음을 알 수 있었다. 3종의 다밀도 안창인 AP 안창, OS 안창, PW 안창을 각각 세 부위로 나누어 안창의 종류와 부위별 충격특성을 비교한 결과 발뒤꿈치 부분이 충격완화 효과가 가장 우수함을 확인할 수 있었다. 반발계수와 중앙주파수에서는 OS 안창이 AP 안창보다 충격완화 효과가 우수함을 보였으나, 감쇠지수는 서로 유사한 견과를 보였다. PW 안창은 두 겹의 폴리우레탄이 전체에 분포되어 있으므로 부위별로 유사한 충격흡수정도를 나타내었다.

보행 시 변형 및 복원이 가능한 인솔에 대한 족저압력 비교 분석 (Comparative Analysis of Foot Pressure Distribution by Functional Insole to be Transformed and Restored During Walking)

  • 박승범;이경득;김대웅;유중현;김경훈
    • 한국운동역학회지
    • /
    • 제21권2호
    • /
    • pp.231-241
    • /
    • 2011
  • The purpose of this study was to analyze the distribution of foot pressure generated by active materials of a functional insole. Comfort is an important consideration while selectingfootwear and insoles. Consequently, it has an influence on injury. The development of new materials for functional insoles is considered one of the more important points for their manufacture. The method adopted in this study is as follows. First, ten healthy males were selected as subjects for the study. Each subject's foof was pre-screened podoscope(Alfoots, Korea) to check for the presence of any foot abnormalities, Two kinds of equipment were used for the study: a foot pressure device from Pedar-X, Germany, and a treadmill from Pulsefitness, UK. Next, each subject was asked to test four types of insoles(insoles of outdoor shoes, indoor shoes, walking shoes, and sports shoes) via walking trials on the treadmill at a constant speed of 4.2 km/h. The pressure distribution data(contact area, maximum force, maximum peak pressure, and maximum mean pressure) was collected using the pressure device at a sampling rate of 100 Hz. Results of the tests showed that all four types of functional insoles increased contact areas whit the foot. Further, functional insoles of walking shoes and sport shoes decreased the foot pressure. From these results, we conclude that the active materials of functional insoles of shoes can increase the contact area and provide greater comfort.

스마트 슈즈의 에너지 하베스팅 기능향상을 위한 복합재료 프레임 특성평가 (Characterization of Composite Frame for Enhancing Energy Harvesting Function of a Smart Shoes)

  • 이호석;정인준;장승환
    • Composites Research
    • /
    • 제34권6호
    • /
    • pp.400-405
    • /
    • 2021
  • 본 연구에서는 인장 시 에너지 하베스팅을 하는 Polyvinylidene Fluoride(PVDF) 리본 하베스터를 신발에 접목한 스마트 슈즈의 에너지 하베스팅 효율을 증가시키기 위한 복합재료 프레임을 설계하였다. 프레임의 하중방향 변형량을 최소화하기 위해 이방성 재료인 탄소 연속 섬유를 사용하여 설계하고 3D 프린터를 이용하여 복잡한 형상을 제작하였다. 보행 시 발생하는 하중에 의한 안창과 중창의 변형량을 계산하기 위해 스프링 요소를 이용하여 안창과 중창을 모델링 하였다. 유한요소 해석을 사용하여 보행 시 스마트 슈즈에 장착된 리본형 하베스터의 인장량을 계산하였다. 예측된 하베스터의 최종 인장 길이 정보는 스마트 슈즈의 에너지 하베스팅 효율 증대에 활용할 수 있을 것으로 기대된다.

족저 압력분포 평가를 위한 Foot Track System의 개발 (Development of the foot track system for the evaluation of foot plantar surface pressure distribution)

  • 이기훈;정민근;김태복
    • 대한인간공학회지
    • /
    • 제11권2호
    • /
    • pp.23-33
    • /
    • 1992
  • The distribution of the pressure between the sole of a feet and a supporting surface can reveal the information about the structure and fonction of the foot and the posural control of the whole body. In particular, the measurement of the vertical contact forces between the plantar surface of the foot and the shoe insole is of great importance to reveal the loading distributio patterns incurred from a particular shoe midsole design. In order to investigate the plantar surface pressure distribution, an insole-type sensor with a piezoelectric material is developed and tested. The present paper describes a new method to completely reduce both the shear force and pyroelectric effects that are normally caused from piezoelectric materials.

  • PDF

직교 그리드 센서가 삽입된 인솔을 이용한 족압분포 연구 (A Study on Foot Pressure by using an Insole Equipped with the Orthogonal Grid Sensor)

  • 손정협;정인준;장승환
    • Composites Research
    • /
    • 제34권3호
    • /
    • pp.161-166
    • /
    • 2021
  • 본 연구에서는 당뇨병 환자들의 균일한 족압 분포를 유도하여 발의 상처를 예방하는 신발을 개발하기 위한 연구방법을 제시하였다. 직교 그리드 센서를 사용하여 일반인의 직립 상태 시 족압 분포를 확인하고, 다양한 조건에 대한 족압분포의 변화를 비교하였다. 신발 바닥부에 삽입된 스프링의 스프링 상수와 인솔의 아치부 유무 등에 따른 족압 분포의 변화를 파악하여 효과적인 족압 분산 조건을 확인하였다. 인체거동의 임의성 등에 의한 실험 오차를 최소화 하기 위해, 직립 상태를 모사한 유한요소해석을 통해 특정 조건에서의 족압 분포를 예측하고 실험 결과와 비교하여 실험의 정확성을 확보할 수 있도록 하였다. 스프링의 개수와 배치에 따른 족압 분포의 변화를 유한요소해석을 통해 확인하여 보다 균일한 족압을 구현할 수 있는 조건을 제시하였다. 이러한 결과는 당뇨발을 가진 환자를 위한 신발 설계에 활용할 수 있을 것으로 기대된다.

당뇨병 환자의 치료용 신발에 대한 연구 (A Study on the Therapeutic Shoes for Diabetic Patients)

  • 이우천;박성식
    • 대한족부족관절학회지
    • /
    • 제8권1호
    • /
    • pp.16-21
    • /
    • 2004
  • Purpose: To investigate the characteristics of the patients and therapeutic shoes for diabetic patients. Materials and Methods: Forty two diabetic patients who had their own therapeutic shoes which were prescribed somewhere else were studied from March 2003 to December 2003. There were 27 males and 15 females, and the mean age was 62.1 years (range, 49-72 years). Duration of diabetes was average 14 years (range, $6{\sim}30$ years), all had type 2 diabetes. Sensation was examined with 5.07 nylon monofilament. The route of purchasing the shoes, compliance to the prescribed shoes were investigated by interview. The shape of shoe, stiffness of upper, conformity of insole to the shape of the foot were recorded. In-shoe plantar pressure was measured in 15 patients. Results: Eighteen patients were insensate to the monofilament. Seven patients did not wear the therapeutic shoes, and only 18 of 35 patients were wearing the therapeutic shoes more than 6 hours a day. The shoes of 17 patients were prescribed by medical doctor and the rest were purchased by the recommendation of acquaintances or advertisement. Ulcer recurred in four of five patients to whom the shoe was prescribed by medical doctor and the cause of three recurrences were evident by just observing the foot and shoe. The therapeutic shoes were made from 11 different makers. Eight shoes were adequate for diabetic patients with respect to the material, shape of insole, type of shoe. In-shoe plantar pressure was examined in 15 patients and was less than 300 kPa in all patients. Conclusion: The therapeutic shoes for the diabetic patients need to be prescribed by medical doctor for selective patients with neuropathy or previous history of ulcer and follow-up examination is important to monitor the compliance of the patients and adequacy of the shoes.

  • PDF

스마트 인솔의 족저압 측정 결과에 대한 타당도 및 신뢰도 평가 (Assessment of Validity and Reliability of Plantar Pressure in Smart Insole)

  • 강호원;안예린;김대유;이동오;박길영;이동연
    • 대한족부족관절학회지
    • /
    • 제26권3호
    • /
    • pp.130-135
    • /
    • 2022
  • Purpose: Smart insoles are wearable devices that are inserted into shoes. Smart insoles with built-in pressure and acceleration sensors can measure the plantar pressure, stride length, and walking speed. This study evaluated the validity and reliability of the plantar pressure measurements of smart insoles during walking on flat ground. Materials and Methods: Twenty one subjects were included in this study. After wearing smart insoles, I-SOL® (Gilon, Seongnam, Korea), the subjects walked a 10 m corridor six times at a rate of 100 steps/min, and the middle three steps, free from direction changes, were chosen for data analysis. The same protocol was repeated after wearing Pedar-X (Novel Corporation, Munich, Germany), an insoletype plantar pressure measurement equipment with proven validity. The average maximum pressure (Ppeak, kPa) and the time at which Ppeak appeared (Ptime, %stride) were calculated for each device. The validity of smart insoles was evaluated by using the interclass correlation coefficient (ICC) of Ppeak and Ptime between the two instruments, and Cronbach's alpha was obtained from the Ppeak values to evaluate the reliability. Results: The ICC of Ppeak was 0.651 (good) in the hallux, 0.744 (good) in the medial forefoot, 0.839 (excellent) in the lateral forefoot, and 0.854 (excellent) in the hindfoot. The ICC of Ptime showed 0.868 (excellent) in the hallux, 0.892 (excellent) in the medial forefoot, 0.721 (good) in the lateral forefoot, and 0.832 (excellent) in the hindfoot. All ICC values showed good or excellent results. The Cronbach's alpha of Ppeak measured in the smart insoles was 0.990 in the hallux, 0.961 in the medial forefoot, 0.973 in the lateral forefoot, and 0.995 in the hindfoot; all indicated excellent reliability in all areas. Conclusion: The plantar pressure measurements of smart insoles during walking on a flat ground showed validity compared to Pedar-X, and high reliability after repeated measurements.