• Title/Summary/Keyword: Materials and methods

Search Result 21,838, Processing Time 0.067 seconds

Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery (변형 근치적 유방절제술 시행 환자의 방사선 치료 시 3D-bolus와 step-bolus의 비교 평가)

  • Jang, Wonseok;Park, Kwangwoo;Shin, Dongbong;Kim, Jongdae;Kim, Seijoon;Ha, Jinsook;Jeon, Mijin;Cho, Yoonjin;Jung, Inho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 2016
  • Purpose : This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. Materials and Methods : The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. Results : The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0.3%. However, to mention the average prescribed dose for the part of lung and heart, that of 3D-bolus was decreased by 11% for lung and by 8% for heart, compared to that of step-bolus. Conclusion : It was confirmed through this research that the dose uniformity could be improved better through the device of 3D-bolus than through the device of step-bolus, as the device of 3D-bolus, produced in consideration of the contact condition of skin surface of chest wall, could be attached to patients' skin more nicely and the thickness of chest wall can be guaranteed more accurately by the device of 3D-bolus. It is considered that 3D-bolus device can be highly appreciated clinically because 3D-bolus reduces the dose on the adjacent organs and make the normal tissues protected, while that gives no reduction of dose on chest wall.

  • PDF

Gene Expression Profiles in Cervical Cancer with Radiation Therapy Alone and Chemo-radiation Therapy (자궁경부암의 방사선치료 및 방사선항암화학 병용치료에 따른 유전자발현 조절양상)

  • Lee Kyu Chan;Kim Meyoung-kon;Kim Jooyoung;Hwang You Jin;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.54-65
    • /
    • 2003
  • Purpose : To analyze the gene expression Profiles of uterine ceulcal cancer, and its variation after radiation therapy, with or without concurrent chemotherapy, using a CDNA microarray. Materials and Methods :Sixteen patients, 8 with squamous ceil carcinomas of the uterine cervix, who were treated with radiation alone, and the other 8 treated w14h concurrent chemo-radiation, were Included in the study. Before the starling of the treatment, tumor biopsies were carried out, and the second time biopsies were peformed after a radiation dose of 16.2$\~$27 Gy. Three normal cervix tissues were used as a control group. The microarray experiments were peformed with 5 groups of the total RNAs extracted individually and then admixed as control, pre-radiation therapy alone, during-radiation therapy alone, pre-chemoradiation therapy, and during-chemoradlation therapy. The 33P-iabeled CDNAS were synthesized from the total RNAs of each group, by reverse transcription, and then they were hybridized to the CDNA microarray membrane. The gene expression of each microarrays was captured by the intensity of each spot produced by the radioactive isotopes. The pixels per spot were counted with an Arrayguage, and were exported to Microsoft Excel The data were normalized by the Z transformation, and the comparisons were peformed on the Z-ratio values calculated. Results : The expressions of 15 genes, including integrin linked kinase (ILK), CDC28 protein kinase 2, Spry 2, and ERK 3, were increased with the Z-ratio values of over 2.0 for the cervix cancer tissues compared to those for the normal controls. Those genes were involved In cell growth and proliferation, cell cycle control, or signal transduction. The expressions of the other 6 genes, Including G protein coupled receptor kinase 5, were decreased with the Z-ratio values of below -2.0. After the radiation thorapy, most of the genes, with a previously Increase expressions, represented the decreased expression profiles, and the genes, with the Z-ratio values of over 2.0, were cyclic nucleotlde gated channel and 3 Expressed sequence tags (EST). In the concurrent chemo-radiation group, the genes involved in cell growth and proliferation, cell cycle control, and signal transduction were shown to have increased expressions compared to the radiation therapy alone group. The expressions of genes involved in anglogenesis (angiopoietln-2), immune reactions (formyl peptide receptor-iike 1), and DNA repair (CAMP phosphodiesterase) were increased, however, the expression of gene involved In apoptosls (death associated protein kinase) was decreased. Conclusion : The different kinds of genes involved in the development and progression of cervical cancer were identified with the CDNA microarray, and the proposed theory is that the proliferation signal stalls with ILK, and is amplified with Spry 2 and MAPK signaling, and the cellular mitoses are Increased with the increased expression oi Cdc 2 and cell division kinases. After the radiation therapy, the expression profiles demonstrated 4he evidence of the decreased cancer cell proliferation. There was no sigificant difference in the morphological findings of cell death between the radiation therapy aione and the chemo-radiation groups In the second time biopsy specimen, however, the gene expression profiles were markedly different, and the mechanism at the molecular level needs further study.

Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images (사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Park, Hee-Chul;Ahn, Jong-Ho;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jin-Sung;Han, Young-Yih;Lim, Do-Hoon;Choi, Doo-Ho
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.155-165
    • /
    • 2010
  • Purpose: In order to evaluate the positional uncertainty of internal organs during radiation therapy for treatment of liver cancer, we measured differences in inter- and intra-fractional variation of the tumor position and tidal amplitude using 4-dimentional computed radiograph (DCT) images and gated orthogonal setup kilovolt (KV) images taken on every treatment using the on board imaging (OBI) and real time position management (RPM) system. Materials and Methods: Twenty consecutive patients who underwent 3-dimensional (3D) conformal radiation therapy for treatment of liver cancer participated in this study. All patients received a 4DCT simulation with an RT16 scanner and an RPM system. Lipiodol, which was updated near the target volume after transarterial chemoembolization or diaphragm was chosen as a surrogate for the evaluation of the position difference of internal organs. Two reference orthogonal (anterior and lateral) digital reconstructed radiograph (DRR) images were generated using CT image sets of 0% and 50% into the respiratory phases. The maximum tidal amplitude of the surrogate was measured from 3D conformal treatment planning. After setting the patient up with laser markings on the skin, orthogonal gated setup images at 50% into the respiratory phase were acquired at each treatment session with OBI and registered on reference DRR images by setting each beam center. Online inter-fractional variation was determined with the surrogate. After adjusting the patient setup error, orthogonal setup images at 0% and 50% into the respiratory phases were obtained and tidal amplitude of the surrogate was measured. Measured tidal amplitude was compared with data from 4DCT. For evaluation of intra-fractional variation, an orthogonal gated setup image at 50% into the respiratory phase was promptly acquired after treatment and compared with the same image taken just before treatment. In addition, a statistical analysis for the quantitative evaluation was performed. Results: Medians of inter-fractional variation for twenty patients were 0.00 cm (range, -0.50 to 0.90 cm), 0.00 cm (range, -2.40 to 1.60 cm), and 0.00 cm (range, -1.10 to 0.50 cm) in the X (transaxial), Y (superior-inferior), and Z (anterior-posterior) directions, respectively. Significant inter-fractional variations over 0.5 cm were observed in four patients. Min addition, the median tidal amplitude differences between 4DCTs and the gated orthogonal setup images were -0.05 cm (range, -0.83 to 0.60 cm), -0.15 cm (range, -2.58 to 1.18 cm), and -0.02 cm (range, -1.37 to 0.59 cm) in the X, Y, and Z directions, respectively. Large differences of over 1 cm were detected in 3 patients in the Y direction, while differences of more than 0.5 but less than 1 cm were observed in 5 patients in Y and Z directions. Median intra-fractional variation was 0.00 cm (range, -0.30 to 0.40 cm), -0.03 cm (range, -1.14 to 0.50 cm), 0.05 cm (range, -0.30 to 0.50 cm) in the X, Y, and Z directions, respectively. Significant intra-fractional variation of over 1 cm was observed in 2 patients in Y direction. Conclusion: Gated setup images provided a clear image quality for the detection of organ motion without a motion artifact. Significant intra- and inter-fractional variation and tidal amplitude differences between 4DCT and gated setup images were detected in some patients during the radiation treatment period, and therefore, should be considered when setting up the target margin. Monitoring of positional uncertainty and its adaptive feedback system can enhance the accuracy of treatments.

Evaluation of Metal Volume and Proton Dose Distribution Using MVCT for Head and Neck Proton Treatment Plan (두경부 양성자 치료계획 시 MVCT를 이용한 Metal Volume 평가 및 양성자 선량분포 평가)

  • Seo, Sung Gook;Kwon, Dong Yeol;Park, Se Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • Purpose: The size, shape, and volume of prosthetic appliance depend on the metal artifacts resulting from dental implant during head and neck treatment with radiation. This reduced the accuracy of contouring targets and surrounding normal tissues in radiation treatment plan. Therefore, the purpose of this study is to obtain the images of metal representing the size of tooth through MVCT, SMART-MAR CT and KVCT, evaluate the volumes, apply them into the proton therapy plan, and analyze the difference of dose distribution. Materials and Methods : Metal A ($0.5{\times}0.5{\times}0.5cm$), Metal B ($1{\times}1{\times}1cm$), and Metal C ($1{\times}2{\times}1cm$) similar in size to inlay, crown, and bridge taking the treatments used at the dentist's into account were made with Cerrobend ($9.64g/cm^3$). Metal was placed into the In House Head & Neck Phantom and by using CT Simulator (Discovery CT 590RT, GE, USA) the images of KVCT and SMART-MAR were obtained with slice thickness 1.25 mm. The images of MVCT were obtained in the same way with $RADIXACT^{(R)}$ Series (Accuracy $Precision^{(R)}$, USA). The images of metal obtained through MVCT, SMART-MAR CT, and KVCT were compared in both size of axis X, Y, and Z and volume based on the Autocontour Thresholds Raw Values from the computerized treatment planning equipment Pinnacle (Ver 9.10, Philips, Palo Alto, USA). The proton treatment plan (Ray station 5.1, RaySearch, USA) was set by fusing the contour of metal B ($1{\times}1{\times}1cm$) obtained from the above experiment by each CT into KVCT in order to compare the difference of dose distribution. Result: Referencing the actual sizes, it was appeared: Metal A (MVCT: 1.0 times, SMART-MAR CT: 1.84 times, and KVCT: 1.92 times), Metal B (MVCT: 1.02 times, SMART-MAR CT: 1.47 times, and KVCT: 1.82 times), and Metal C (MVCT: 1.0 times, SMART-MAR CT: 1.46 times, and KVCT: 1.66 times). MVCT was measured most similarly to the actual metal volume. As a result of measurement by applying the volume of metal B into proton treatment plan, the dose of $D_{99%}$ volume was measured as: MVCT: 3094 CcGE, SMART-MAR CT: 2902 CcGE, and KVCT: 2880 CcGE, against the reference 3082 CcGE Conclusion: Overall volume and axes X and Z were most identical to the actual sizes in MVCT and axis Y, which is in the superior-Inferior direction, was regular in length without differences in CT. The best dose distribution was shown in MVCT having similar size, shape, and volume of metal when treating head and neck protons. Thus it is thought that it would be very useful if the contour of prosthetic appliance using MVCT is applied into KVCT for proton treatment plan.

Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy (가임기 여성의 방사선 치료 시 난소 선량 평가)

  • Park, Sung Jun;Lee, Yeong Cheol;Kim, Seon Myeong;Kim, Young Bum
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.145-153
    • /
    • 2021
  • Purpose: The purpose of this study is to evaluate the ovarian dose during radiation therapy for breast cancer in women of childbearing age through an experiment. The ovarian dose is evaluated by comparing and analyzing between the calculated dose in the treatment planning system according to the treatment technique and the measured dose using a thermoluminescence dosimeter (TLD). The clinical usefulness of lead (Pb) apron is investigated through dose analysis according to whether or not it is used. Materials and Methods: Rando humanoid phantom was used for measurement, and wedge filter radiation therapy, 3D conformal radiation therapy, and intensity modulated radiation therapy were used as treatment techniques. A treatment plan was established so that 95% of the prescribed dose could be delivered to the right breast of the Rando humanoid phantom 3D image obtained using the CT simulator. TLD was inserted into the surface and depth of the virtual ovary of the Rando hunmanoid phantom and irradiated with radiation. The measurement location was the center of treatment and the point moved 2 cm to the opposite breast from the center of the Rando hunmanoid phantom, 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm from the boundary of the right breast to the center of treatment and downward, and the surface and depth of the right ovary. Measurements were made at a total of 9 central points. In the dose comparison of treatment planning systems, two wedge filter treatment techniques, three-dimensional conformal radiotherapy, and intensity-modulated radiation therapy were established and compared. Treatments were compared, and dose measurements according to the use of lead apron were compared and analyzed in intensity-modulated radiation therapy. The measured value was calculated by averaging three TLD values for each point and converting using the TLD calibration value, which was calculated as the point dose mean value. In order to compare the treatment plan value with the actual measured value, the absolute dose value was measured and compared at each point (%Diff). Results: At Point A, the center of treatment, a maximum of 201.7cGy was obtained in the treatment planning system, and a maximum of 200.6cGy was obtained in the TLD. In all treatment planning systems, 0cGy was calculated from Point G, which is a point 17.5cm downward from the breast interface. As a result of TLD, a maximum of 2.6cGy was obtained at Point G, and a maximum of 0.9cGy was obtained at Point J, which is the ovarian dose, and the absolute dose was 0.3%~1.3%. The difference in dose according to the use of lead aprons was from a maximum of 2.1cGy to a minimum of 0.1cGy, and the %Diff value was 0.1%~1.1%. Conclusion: In the treatment planning system, the difference in dose according to the three treatment plans did not show a significant difference from 0.85% to 2.45%. In the ovary, the difference between the Rando humanoid phantom's treatment planning system and the actual measured dose was within 0.9%, and the actual measured dose was slightly higher. This did not accurately reflect the effect of scattered radiation in the treatment planning system, and it is thought that the dose of scattered radiation and the dose taken by CBCT with TLD inserted were reflected in the actual measurement. In dosimetry according to the with or without a lead apron, when a lead apron was used, the closer the distance from the treatment range, the more effective the shielding was. Although it is not clinically appropriate for pregnancy or artificial insemination during radiotherapy, the dose irradiated to the ovaries during treatment is not expected to significantly affect the reproductive function of women of childbearing age after radiotherapy. However, since women of childbearing age have constant anxiety, it is thought that psychological stability can be promoted by presenting the data from this study.

Evaluation of Standardized Uptake Value and Metabolic Tumor Volume between Reconstructed data and Re-sliced data in PET Study (PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.3-8
    • /
    • 2016
  • Purpose SUV is one of the parameters that assist diagnosis in origin, metastasis and staging of cancer. Specially, it is important to compare SUV before and after chemo or radiation therapy to find out effectiveness of treatment. Storing PET data which has no quantitative change is needed for SUV comparison. However, there is a possibility to loss the data in external hard drive or MINIpacs that are managed by department of nuclear medicine. The aim of this study is to evaluate SUV and metabolic tumor volume (MTV) among reconstructed data (R-D) in workstation, R-D and re-sliced data (S-D) in PACS. Materials and Methods Data of 20 patients (aged $60.5{\pm}8.3y$) underwent $^{18}F-FDG$ PET (Biograph truepoint 40, mCT 40, mCT 64, mMR, Siemens) study were analysed. $SUV_{max}$, $SUV_{peak}$ and MTV were measured in liver, aorta and tumor after sending R-D in workstation, R-D and S-D in PACS to syngo.via software. Results R-D of workstation and PACS showed the same value as mean $SUV_{max}$ in liver, aorta and tumor were $2.95{\pm}0.59$, $2.35{\pm}0.61$, $10.36{\pm}6.15$ and $SUV_{peak}$ were $2.70{\pm}0.51$, $2.07{\pm}0.43$, $7.67{\pm}3.73$(p>0.05) respectively. Mean $SUV_{max}$ of S-D in PACS were decreased by 5.18%, 7.22%, 12.11% and $SUV_{peak}$ 2.61%, 3.63%, 10.07%(p<0.05). Correlation between R-D and S-D were $SUV_{max}$ 0.99, 0.96, 0.99 and $SUV_{peak}$ 0.99, 0.99, 0.99. And 2SD in balnd-altman analysis were $SUV_{max}$ 0.125, 0.290, 1.864 and $SUV_{peak}$ 0.053, 0.103, 0.826. MTV of R-D in workstation and PACS show the same value as $14.21{\pm}12.72cm^3$(p>0.05). MTV in PACS was decreased by 0.12% compared to R-D(p>0.05). Correlation and 2SD between R-D and S-D were 0.99 and 2.243. Conclusion $SUV_{max}$, $SUV_{peak}$, MTV showed the same value in both of R-D in workstation and PACS. However, there was statistically difference in $SUV_{max}$, $SUV_{peak}$ of S-D compare to R-D despite of high correlation. It is possible to analyse reliable pre and post SUV if storing R-D in main hospital PACS system.

  • PDF

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF

Combined Chemotherapy and Radiation Therapy in Limited Disease Small-Cell Lung Cancer (국한성 소세포 폐암에서 항암 화학 및 흉부 방사선치료의 병합요법 적응)

  • Kim Moon Kyung;Ahn Yong Chan;Park Keunchil;Lim Do Hoon;Huh Seung Jae;Kim Dae Yong;Shin Kyung Hwan;Lee Kyu Chan;Kwon O Jung
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.9-15
    • /
    • 1999
  • Purpose : This is a retrospective study to evaluate the response rate, acute toxicity, and survival rate of a combined chemotherapy and radiation therapy in limited disease small cell lung cancer, Materials and Methods : Firty-six patients with limited disease small-cell lung cancer who underwent combined chemotherapy and radiation therapy between October 1994 and April 1998 were evaluated. Six cycles of chemotherapy were planned either using a VIP regimen etoposide, ifosfamide, and cis-platin) or a EP regimen (etoposide and cis-platin). Thoracic radiation therapy was planned to deli- ver 44 Gy using 1 OMV X-ray, starting concurrently with chemotherapy. Response was evaluated 4 weeks after the completion of the planned chemotherapy and radiation therapy, and the prophylaetic cranial irradiation was planned only for the patients with complete responses. Acute toxicity was evaluated using the SWOG toxicity criteria, and the overall survival and disease-free survival were calculated using the Kaplan-Meier Method. Results : The median follow-up period was 16 months (range:2 to 41 months). Complete response was achieved En 30 (65$\%$) patients, of which 22 patients received prophylactic cranial irradiations. Acute toxicities over grade III were granulocytopenia in 23 (50$\%$), anemia in 17 (37$\%$), thrombo- cytopenia in nine (20$\%$), alopecia in nine (20$\%$), nausea/vomiting in five (11$\%$), and peripheral neuropathy in one (2$\%$). Chemotherapy was delayed in one patient, and the chemotherapy doses were reduced in 58 (24$\%$) out of the total 246 cycles. No radiation esophagitis over grade 111 was observed, while interruption during radiation therapy for a mean of 8.3 days occurred in 21 patients. The local recurrences were observed in 8 patients and local progressions were in 6 patients, and the distant metastases in 17 patients. Among these, four patients had both the local relapse and the distant metastasis. Brain was the most common metastatic site (10 patients), followed by the liver as the next common site (4 patients). The overall and progression-free survival rates were 79$\%$ and 55$\%$ in 1 year, and 45'/) and 32% in 2 years, respectively, and the median survival was 23 months. Conclusion : Relatively satisfactory local control and suwival rates were achieved after the combined chemotherapy and radiation therapy with mild to moderate acute morbidities in limited disease small cell lung cancer.

  • PDF

Analysis of Bone Mineral Density and Related Factors after Pelvic Radiotherapy in Patients with Cervical Cancer (골반부 방사선 치료를 받은 자궁경부암 환자의 골밀도 변화와 관련 인자 분석)

  • Yi, Sun-Shin;Jeung, Tae-Sig
    • Radiation Oncology Journal
    • /
    • v.27 no.1
    • /
    • pp.15-22
    • /
    • 2009
  • Purpose: This study was designed to evaluate the effects on bone mineral density (BMD) and related factors according to the distance from the radiation field at different sites. This study was conducted on patients with uterine cervical cancer who received pelvic radiotherapy. Materials and Methods: We selected 96 patients with cervical cancer who underwent determination of BMD from November 2002 to December 2006 after pelvic radiotherapy at Kosin University Gospel Hospital. The T-score and Z-score for the first lumbar spine (L1), fourth lumbar spine (L4) and femur neck (F) were analyzed to determine the difference in BMD among the sites by the use of ANOVA and the post-hoc test. The study subjects were evaluated for age, body weight, body mass index (BMI), post-radiotherapy follow-up duration, intracavitary radiotherapy (ICR) and hormonal replacement therapy (HRT). Association between the characteristics of the study subjects and T-score for each site was evaluated by the use of Pearson's correlation and multiple regression analysis. Results: The average T-score for all ages was -1.94 for the L1, -0.42 for the L4 and -0.53 for the F. The average Z-score for all ages was -1.11 for the L1, -0.40 for the L4 and -0.48 for the F. The T-score and Z-score for the L4 and F were significantly different from the scores for the L1 (p<0.05). There was no significant difference between the L4 and F. Results for patients younger than 60 years were the same as for all ages. Age and ICR were negatively correlated and body weight and HRT were positively correlated with the T-score for all sites (p<0.05). BMI was positively correlated with the T-score for the L4 and F (p<0.05). Based on the use of multiple regression analysis, age was negatively associated with the T-score for the L1 and F and was positively correlated for the L4 (p<0.05). Body weight was positively associated with the T-score for all sites (p<0.05). ICR was negatively associated with the T-score for the L1 (p<0.05). HRT was positively associated with the T-score for the L4 and F (p<0.05). Conclusion: The T-score and Z-score for the L4 and F were significantly higher than the scores for the L1, a finding in contrast to some previous studies on normal women. It was thought that radiation could partly influence BMD because of a higher T-score and Z-score for sites around the radiotherapy field. We suggest that a further long-term study is necessary to determine the clinical significance of these findings, which will influence the diagnosis of osteoporosis based on BMD in patients with cervical cancer who have received radiotherapy.

The Radioprotective Effect and Mechanism of Captopril on Radiation Induced-Heart Damage in Rats (방사선 조사 후 발생한 흰쥐 심장손상에서 Captopril의 방어역할과 기전)

  • Chang Seung-Hee;Lee Kyung-Ja;Koo Heasoo
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.40-54
    • /
    • 2004
  • Purpose : Captopril (angiotension converting enzyme inhibitor) is known to have a radioproptective effect in the lungs, intestines and skin, but its effect in the heart is unclear. To investigate the radioprotectlve efiect and mechanism of captopril on the heart, the histopathological changes and immunohistochemical stains were compared with radiation alone, and radiation combined with captopril, in the rats. Materials and Methods : The histopathological changes and immunohistochemical stains ($TNF{\alpha}$, $TGF{\beta}1$, PDGF and FGF2) were examined in the radiation alone and the combined captopril and radiation groups, 2 and 8 weeks after irradiation. Each group consisted of 8 to 10 rats (Sprague-Dawley). Irradiation (12.5 Gy) was given to the left hemithorax in a single fraction. Captopril (50 mg/Kg/d) mixed with water, was given orally and continuously from the first week prior to, up to the 8th week of the experiment. Results : In the radiation alone group, the ventricle at 2 weeks after irradiation showed prominent edema (p=0.082) and fibrin deposit (p=0.018) compared to the control group. At 8 weeks, the edema was decreased and fibrosis increased compared to those at 2 weeks. The histopathological changes of the combined group were similar to those of the control group, due to the reduced radiation toxicity at 2 and 8 weeks. The endocardial fibrin deposit (p=0.047) in the atrium, and the interstitial fibrin deposit (p=0.019) and edema (p=0.042) of the ventricle were reduced significantly in the combined group compared to those in the radiation alone group at 2 weeks. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$, PDGF and FGF-2 in the radiation alone group were more increased than in the control group, especially in the pericardium and endocardium of the atrium at 2 weeks. At 8 weeks, the pericardial $TNF-{\alpha}$ and $TGF-{\beta}1$ in the radiation alone group continuously increased. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$ and PDGF were decreased in the combined group at 2 weeks. At 8 weeks, the expressions of $TNF-{\alpha}$ in the atrial and ventricular pericardia were markedly reduced (p=0.049, p=0.009). Conclusion : This study revealed that the early heart damage induced by radiation can be reduced by the addition of captopril in a rat model. The expressions of $TNF-{\alpha}$, $TGF-{\beta}1$ and PDGF were further decreased in the combined compared to the radiation alone group at both 2 and 8 weeks. From these results, it may be concluded that these cytokines probably play roles in the radioprotective mechanism of captopril from the radiation-induced heart toxicity, similarly to in other organs.