• Title/Summary/Keyword: Material fracture

Search Result 1,963, Processing Time 0.028 seconds

Determination of CTOD & CTOA Curve for Structural Steel Hot-Rolled Thin Plates (일반 구조용강 열간압연 박판에 대한 CTOD와 CTOA 곡선 결정)

  • 이계승;이억섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.729-732
    • /
    • 2003
  • The K-R design curve is an engineering method of linear-elastic fracture analysis under plane-stress loading conditions. By the way, linear-elastic fracture mechanics (LEFM) is valid only as long as nonlinear material deformation is confined to a small region surrounding the crack tip. Like general steels, it is virtually impossible to characterize the fracture behavior with LEFM, in many materials. Critical values of J contour integral or crack tip opening displacement (CTOD) give nearly size independent measures of fracture toughness, even for relatively large amounts of crack tip plasticity. Furthermore, the crack tip opening displacement is the only parameter that can be directly measured in the fracture test. On the other. the crack tip opening angle (CTOA) test is similar to CTOD experimentally. Moreover, the test is easier to measure the fracture toughness than other method. The shape of the CTOA curve depends on material fracture behavior and, on the opening configuration of the cracked structure. CTOA parameter describes crack tip conditions in elastic-plastic materials, and it can be used as a fracture criterion effectively. In this paper, CTOA test is performed for steel JS-SS400 hot-rolled thin plates under plane-stress loading conditions. Special experimental apparatuses are used to prevent specimens from buckling and to measure crack tip opening angle for thin compact tension (CT) specimens.

  • PDF

An analytical and computational study on energy dissipation along fracture process zone in concrete

  • Zhao, Yanhua;Xu, Shilang;Li, Zongjin
    • Computers and Concrete
    • /
    • v.1 no.1
    • /
    • pp.47-60
    • /
    • 2004
  • The influence of the fracture process zone (FPZ) on the fracture properties is one of the hottest topics in the field of fracture mechanics for cementitious materials. Within the FPZ in front of a traction free crack, cohesive forces are distributed in accordance with the softening stress-separation constitutive relation of the material. Therefore, further crack propagation necessitates energy dissipation, which is the work done by the cohesive forces. In this paper $g_f$, the local fracture energy characterizing the energy consumption due to the cohesive forces, is discussed. The computational expression of $g_f$ in the FPZ can be obtained for any stage during the material fracture process regarding the variation of FPZ, whether in terms of its length or width. $G_{fa}$, the average energy consumption along the crack extension region, has also been computed and discussed in this paper. The experimental results obtained from the wedge splitting tests on specimens with different initial notch ratios are employed to investigate the property of the local fracture energy $g_f$ and the average value $G_{fa}$ over the crack extension length. These results can be used to indicate the influence of the FPZ. Additionally, changes in the length of the FPZ during the fracture process are also studied.

ACOUSTIC EMISSION ANALYSIS FOR FRACTURE CHARACTERISTICS OF DENTAL POSTERIOR COMPOSITES (구치부 수복용 복합레진의 파괴특성에 관한 Acoustic Emission 연구)

  • Park, Jin-Hoon;Kim, Kyo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.153-165
    • /
    • 1992
  • Dental composite resin is a kind of the particle - reinforced composite material, and is widely used in recent dental restoration of anterior and posterior tooth region. The purpose of this study was to investigate the fracture behaviour according to volume fractions and external findings of the filler particles for better interpretation of the fracture characteristics of posterior dental composite resins by analytic method of fracture mechanics. The plane strain fracture toughness($K_{IC}$) and Acoustic Emission were determined with three - point bending test using the single edge notch specimen according to the ASTM - E399, and its analyzed data was compared with filler volume fractions derived from the standard ashing test and scanning electron fractographs of each specimen including the unfilled experimental resin as a control. The results were that the value of fracture toughness of the composite resin material was in the range from 0.85 MPa$\sqrt{m}$ to 1.60 MPa$\sqrt{m}$ and was higher than the value of the unfilled experimental resin, and the fracture behaviours dervied from Acoustic Emission analysis show prominent differences according to the volume fraction and the size of filler particles used in each composite resin. The degree of resistance against crack propagation seems to be increase and the fractographs demonstrate the high degree of surface roughness and irregularity according with the increase of fracture toughness value.

  • PDF

Experimental Study on Fracture Protect Effect in Mouthguards (수종의 마우스가드에 대한 파절방지효과 비교)

  • Kim, Nam-Joong;Kim, So-Min
    • Journal of Technologic Dentistry
    • /
    • v.31 no.2
    • /
    • pp.31-38
    • /
    • 2009
  • In recent year, the population for sports has been increased and lots of wounded patients at the oral & facial portion were troubled with the accidents. So, it was needed to protect them from the sports accident, by the use of the mouthguard appliance. This study was done as ae guide for selection of the mouthguard materials. Such mouthguards classified as E.V.A., PE, silicone as material, Scheu(Germany), Tru-Tain(U.S.A.), Dreve(Germany) as companies, 1.5mm, 3.0mm, and 4.0mm as thickness and single sheet, soft double sheet, hard double sheet methods were selected for experiment to compare the fracture protect test. The obtained results are as follows. 1. All types of mouthguards, whatever differences there are in material, production company, procedure and the thickness, were effective for fracture protect effect. 2. The most effective one for fracture protection was recommended as E.V.A. in material, and Tru-Tain in company. 3. More thick, and soft & hard multi sheets productions were more effective for fracture protection.

  • PDF

A Study on the Fracture Toughness of Plasma-treated Aluminum/Aluminum Foam Composites using Nitrogen Gas (알루미늄/발포알루미늄의 질소 플라즈마 표면처리에 따른 파괴인성평가)

  • Chung, Hyup-Jae;Rhee, Kyong-Yop;Han, Beom-Suck;Ryu, Yong-Mun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.51-56
    • /
    • 2008
  • Aluminum foam material has unique properties that make them useful in applications to the automobile, construction and railroad industries. In this study, aluminum was plasma-treated using nitrogen gas to improve fracture behavior between aluminum and aluminum foam material. SLS specimens were used for fracture tests. They were performed using plasma-treated and untreated aluminum/aluminum foam specimens. It was shown that the fracture strength and the tincture toughness of aluminum/aluminum foam were improved ${\sim}86%\;and\;{\sim}250%$, respectively when the aluminum was plasma-treated using nitrogen gas.

Fracture Analysis of Hole Flanging Process for High Strength Steel Sheets (고강도 열연판재의 홀 플랜정시 파단특성연구)

  • 김정운;김봉준;문영훈
    • Transactions of Materials Processing
    • /
    • v.10 no.6
    • /
    • pp.465-470
    • /
    • 2001
  • Hole flanging experiments are performed on flat circular plates with a hole in the center and the flangeability and fracture behaviors of TRIP steels and ferrite-Bainite duplex steels were examined. In the hole flanging, deformation by lip and petalling occurs when plates are struck by punches of various shapes and high circumferential strains induced in the target material cause radial cracking and the subsequent rotation of the affected plate material in a number of symmetric petals. In all cases, failure of the plate was due to lip fracture that results from multiple localized neckings that take place around the hole periphery where straining is most severe and a somewhat regular pattern was observed in a fracture shape. The neck characteristics in flange formation and the transition from the lip to petal mode at which fracture occurs were compared with two materials.

  • PDF

A Study on the Cutting Characteristics in the Machining of SKD11 by Face Milling (난삭재인 SKD11의 정면밀링 가공시 절삭특성에 관한 연구)

  • 김형석;문상돈;김태영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.73-78
    • /
    • 1994
  • Wear and fracture mode of ceramic tool for hardened SKD11 steel was investigated by face milling in this study. The cutting force and Acoustic Emission(AE) signal were utilized to detect the wear and fracture of ceramic tool. The following conclusions were obtained : (1) The wear and fracture modes of ceramic tool are characterized by three types: \circled1wear which has normal wear and notch wear, \circled2 wear caused by scooping on the rake face, \circled3 large fracture caused by thermal crack in the rake face. (2) The wear behaviour of ceramic tool can be detected by the increase of mean cutting force and the variation of the AE RMS voltage. (3) The catastrophic fracture of ceramic tool can be detected by the cutting force(Fz-component). (4) As the hardness of work material increased, Acoustic Emission RMS value and mean cutting force(Fz) increased linearly, but the tool life decreased.

  • PDF

A Study on the Fracture Behavior of Tooth Interfacial Layer, DEJ (Dental Enamel Junction) (치아 계면 층 DEJ(Dental Enamel Junction)의 파괴 거동에 관한 수치해석적 연구)

  • Mishra, Dhaneshwar;Yoo, Seung-Hyun;Jeong, Ung-Rak
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.3
    • /
    • pp.284-291
    • /
    • 2011
  • Numerical experiments on biological interfacial layer, DEJ by finite element software ABAQUS have been conducted to study its fracture behavior including crack bridging / arresting characteristics in the model. Crack growth simulation has been carried out by numerical tool, XFEM, devoted to study cracks and discontinuities. The fracture toughness of DEJ has been estimated before and after crack bridging. The implications of bridging in numerical study of fracture behavior of DEJ-like biological interface have been discussed. It has been observed that the results provided by the numerical studies without proper accommodation of bridging phenomenon can mislead. This study can be helpful for understanding the DEJ-like biological interface in terms of its fracture toughness, an important material characteristics. This property of the material is an important measure that has to be taken care during design and manufacturing processes.

A cohesive model for concrete mesostructure considering friction effect between cracks

  • Huang, Yi-qun;Hu, Shao-wei
    • Computers and Concrete
    • /
    • v.24 no.1
    • /
    • pp.51-61
    • /
    • 2019
  • Compressive ability is one of the most important mechanical properties of concrete material. The compressive failure process of concrete is pretty complex with internal tension, shear damage and friction between cracks. To simulate the complex fracture process of concrete at meso level, methodology for meso-structural analysis of concrete specimens is developed; the zero thickness cohesive elements are pre-inserted to simulate the crack initiation and propagation; the constitutive applied in cohesive element is established to describe the mechanism of crack separation, closure and friction behavior between the fracture surfaces. A series of simulations were carried out based on the model proposed in this paper. The results reproduced the main fracture and mechanical feature of concrete under compression condition. The effect of key material parameters, structure size, and aggregate content on the concrete fracture pattern and loading carrying capacities was investigated. It is found that the inner friction coefficient has a significant influence on the compression character of concrete, the compression strength raises linearly with the increase of the inner friction coefficient, and the fracture pattern is sensitive to the mesostructure of concrete.

Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designs

  • Chaturvedi, Saurabh;Alqahtani, Turki;Alsolami, Saleh;Alqahtani, Abdulbari;Das, Gotam;Alsubaiy, Ebrahim
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.36-45
    • /
    • 2021
  • Purpose. To investigate the fracture resistance of monolithic CAD-CAM all-ceramic surveyed crowns with two different occlusal rest seat designs. Materials and Methods. Two maxillary first premolar were prepared for all-ceramic surveyed crowns with wide (2/3rd of buccolingual width of an unprepared tooth) or narrow (1/3rd of buccolingual width of an unprepared tooth) disto-occlusal rest seat (ORS) designs. Eighty monolithic CAD-CAM all-ceramic surveyed crowns were prepared and divided into 4 groups - Group CR, Composite resin material as a control; Group LDS, Lithium disilicate based material; Group ZIPS, zirconia-material (IPS ZirCAD); and Group ZLHT, zirconia- material (CeramillZolidht+). Crowns were cemented on an epoxy resin die with adhesive resin cement. The fracture resistance of crowns was tested with the universal machine. Univariate regression analysis was used. Results. The mean ± standard deviation of maximum failure force values varied from 3476.10 ± 285.97 N for the narrow ORS subgroup of group ZIPS to 687.89 ± 167.63 N for the wide ORS subgroup of group CR. The mean ± standard deviation of maximum force was 1075 ± 77.0 N for group CR, 1309.3 ± 283.9 N for group LDS, 3476.1 ± 285.97 N for group ZIPS, and 2666.7 ± 228.21 N for group ZLHT, with narrow occlusal rest seat design. The results of the intergroup comparison showed significant differences in fracture strength with various material groups and occlusal rest seat designs (P<.001). Conclusion. The zirconia-based all-ceramic surveyed crowns fractured at more than double the load of Lithium disilicate based crowns. The crowns with narrow base occlusal rest seat design had statistically significantly higher fracture resistance than surveyed crowns with wide occlusal rest seat design. The use of narrow occlusal rest seat design in CAD-CAM all ceramic surveyed crowns provides higher fracture resistance, and therefore narrow occlusal rest design can be used for providing esthetics with high strength.