• 제목/요약/키워드: Material Evaluations

검색결과 246건 처리시간 0.025초

이동형 방사선 발생장치 차폐물 설치에 관한 연구 (A study on Protector Performance Evaluation According to X-ray Scattering Distribution of Portable Radiation System)

  • 김형균;성동근;조경미;김상범;김재영;최준호
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.85-92
    • /
    • 2009
  • This study, "The study about performance evaluations of mobile cover for X-ray's diffusion and distribution in mobile radiation" is based on the rules of mobile defense apparatus for radiation producer in 2006. To use the mobile cover for X-ray for diagnosis has been compulsory in common wards except operation rooms, emergency rooms and intensive care units. we have confirmed the effect in arbitrary shielding material after Qualitiy Control was carried out for accuracy in an experiment of mobile photographing equipment. The performance evaluation was conducted with the fabrics of selenium, 0.2 mmPb, 0.1 mmPb and aluminiums. Considering the result, we choosed 0.1 mmPb and attached cover to mobile photographing equipment. We have finished making the cover after drew up the draft to attach cover to mobile photographing equipment through the modeling and the structural analysis. the process of the study is that we assembled the manufactured structures and carried out the practical experiment to take the photograph after attaching the fabric of 0.1 mmPb to mobile photographing equipment. It is need of additional thesises hereafter that we compare the result between the part to improve for safety besides convenience in photographic experiment about clinical radiation and the effect of covering the diffusion in condition attached the cover.

  • PDF

화학물질 유해성에 대한 작업자와 관리자들의 인식 (Perception of Workers and Managers for the Chemical Hazard)

  • 조용민;김희정;최재욱
    • 한국산업보건학회지
    • /
    • 제22권4호
    • /
    • pp.293-300
    • /
    • 2012
  • Objectives: In chemical hazard communication, information receiver's perception is a important factor, but the study on the perception was few. Therefore, this study evaluated the perception of managers and workers group about chemical hazard communication by chemical hazard communication tools that were being used in fields. Methods: 91 managers and 238 workers were surveyed in two companies where use chemicals. All subjects were asked about the comprehensibility and perception for MSDS and GHS Pictograms being used in their workplaces through face-to-face interviews. Results: Most of the respondents knew MSDS, and more than half of the respondents had used MSDS once or more per year. The level of use to find the information on chemicals with MSDS was higher in the managers in comparison with workers. Also, the managers could understand and find the information on MSDS easier(p < 0.05). In the question asking the meaning of GHS Pictograms, the managers responded more correctly, as well(p < 0.05). 86.8% of the managers and 62.6% of the workers were conscious of the possible health hazards of chemicals that they could be exposed at work. However, among the respondents conscious of the health hazards, only less than 70% were well aware of the contents of the health hazards correctly. Conclusions: In chemical hazard communication, it is very important to evaluate whether information receiver have proper and correct knowledge and perception or not and actions based on the evaluations as well as provide correct information.

필라멘트로 구성(構成)된 위편성물(緯編成物)및 모델의 광학적(光學的) 특성(特性)에 관(關)한 연구(硏究) (A Study on the Optical Properties of the Filament Yarn Weft Knit Fabrics and the 3-dimensional Model)

  • 신혜선;김종준;전동원
    • 패션비즈니스
    • /
    • 제6권5호
    • /
    • pp.1-11
    • /
    • 2002
  • Today, great percentage of apparel fabrics comprise knit products. A few apparel items are almost exclusively made from knit products including sweaters, T-shirts, lingerie, and hosiery. In weft knits, intermeshing yarn traverses the fabric crosswise. The production rate of knitting machines is about four times higher than that of conventional looms iin proportion to the amount of fabric produced per unit time. Knit apparels fabrics are noted for freedom of body movement, easy-care, resilience, soft draping and quality. The appearance of fabrics is of prime importance along with tactile features such as smoothness, crispness, stiffness when we deal with the handling evaluation of the textiles. In practice, the quality and performance of fabrics judged by sighted evaluators, and it is perhaps logical, in attempting to establish an effective fabric objective measurement system. It is worthwhile to make objective measurement that correlate well with subjective evaluations made by sight and touch together. However, it often imposes difficulties to effectively measure and analyze the appearance or optical properties of the textile surface features. In this study, an attempt is made to provide a preliminary approach to the analysis of the gloss property, which is one of the optical properties of fabrics. The specimens range from 70/24 nylon 6 filament yarn knit fabric to 70/68 nylon 6 filament yarn knit fabric, the latter being finer. A few three-dimensional models based on Peirce's model of knit stitch have been proposed and material properties were given to calculate the properties. Goniophotometric measurements of the specimens were also carried out.

원전 피로 감시 시스템 개발 및 적용 현황 (Current Status on the Development and Application of Fatigue Monitoring System for Nuclear Power Plants)

  • 부명환;이경수;오창균;김현수
    • 한국압력기기공학회 논문집
    • /
    • 제13권2호
    • /
    • pp.1-18
    • /
    • 2017
  • 세계적으로 원자력발전소의 안정적 운영 및 안전성 확보를 위해 수명기간 중 주요 기기 및 배관의 실제 운전 과도상태를 체계적으로 관리하고, 피로 손상의 정량적 평가 및 관리를 위한 체계적인 시스템이 요구되고 있는 실정이다. 이에 본 논문에서는 원자력발전소의 안전등급 1 설비에 대한 피로 평가요건을 분석하였고, 피로 감시방법 및 절차와 웹 기반으로 개발된 피로 감시 시스템인 NuFMS 개발 및 검증 내용을 기술하였다. NuFMS는 설계 시 고려한 과도상태 발생 횟수 대 비발전소의 특정 운전 시점에서의 실제 발생 횟수를 비교하여 안전 여유도의 정량적 확인이 가능하며, 누적피로사용계수 도출을 통해 정확한 피로영향 분석뿐만 아니라 손상 관리가 가능하다. 이와 같이 NuFMS의 적용을 통해 원자력발전소 기기 및 배관의 피로 건전성을 확인하고 운영 신뢰도를 향상시킬 수 있으며, 발전소의 안전성 유지 및 운영비용 절감 등의 효과를 기대할 수 있다. 따라서 향후 국내 전 원전에 NuFMS를 확대 적용할 예정이며, 이러한 기술의 해외 수출을 적극 추진 중이다.

Whey Protein Isolate(WPI)의 대체비율을 달리한 스폰지 케이크의 품질 특성에 관한 연구 (The Quality Characteristics of Sponge Cake with Varied Levels of Whey Protein Isolate)

  • 안명수;김찬희
    • 한국식품조리과학회지
    • /
    • 제23권1호통권97호
    • /
    • pp.41-49
    • /
    • 2007
  • The substitution effects of whey protein isolate(WPI) for egg in the preparation of sponge cake were determined by objective and subjective tests. Milk whey is drained from milk curd as a by-product of cheese manufacture. Whey protein is known as a good nutritional source and a functional material for many processed foods, especially baked goods. WPI contains above 90% whey protein. The specific gravity and viscosity of sponge cakes tend to be affected by WPI substitution. The cooking loss of sponge cakes with WPI substituted for egg(abbreviated as WPI cake) during oven baking was smaller than that made with egg(abbreviated as egg cake) and the specific loaf volume of WPI cake was larger than that of egg cake. The number of pores was highly increased and the size of pores was more uniformly and finely distributed in the cross section of WPI cake than those of egg cake, as observed by scanning electron microscopy(SEM). The hardness, gumminess and chewiness of WPI cake made with 10-20% WPI substitution were the lowest among all the tested cakes, including egg cake, thereby confirming the considerable improvement in their cake qualities. By the results of sensory evaluation, appearance, pore uniformity, softness, chewiness, moistness, flavor, mouth feeling, and overall acceptability of 10-20% WPI substitute cakes were evaluated as being significantly superior to those of all other cakes(p<0.05). These results support the better physicochemical characteristics and sensory evaluations of sponge cake prepared with 10-20% of WPI substitution for egg.

악안면 골절 치료시 흡수성 고정판의 사용에 관한 임상 연구 (CLINICAL STUDY OF RESORBABLE PLATE AND SCREW FOR TREATMENT OF MAXILLOFACIAL FRACTURES)

  • 정종철;최세훈;송민석;전창훈;김현민
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권6호
    • /
    • pp.438-443
    • /
    • 2003
  • Purpose : This study evaluated the usefulness of resorbable plate and screw for treatment of maxillofacial bone fractures. Patients and methods : From july, 2000 to july, 2002, we used resorbable plates and screws($Biosorb^{(R)}$ FX, Bionix Inc, Finland) on 126 patients for treatment of maxillofacial bone fractures. Among them, 80 patients were capable of periodic following up to present season. We evaluated these patients with clinical, radiographic findings and subjective satisfaction. Results : 80 patients composed of 63 men and 17 women. Complication rates are 7.5%(6/80) recorded. 1 of bulging sensation, 3 of infection sign, 2 of the plate detachment were shown. The plates involved in such complications were removed. The other patients(92.5%) were not shown any problems. We could not find complete resorption of screw holes in the mandibular symphysis area even though two years later after surgery. Conclusion : Bioresorbable plates and screws are useful as fixation material at maxillofacial fractures although strength is thought to be weaker than titanium plate. But to reduce the possible complicaions, need to careful clinical and radiographical evaluations.

보트에 적용되는 하이브리드 복합재에 대한 기계적 특성 연구 (Research on Mechanical Properties and Characteristics of Hybrid Composites for Boat)

  • 조제형;김성훈;윤성원;하종록;김명현
    • Journal of Welding and Joining
    • /
    • 제34권2호
    • /
    • pp.22-29
    • /
    • 2016
  • Recently, Application of composite materials are increased in transport area for weight reduction. Also, Related technical developments have been implemented actively at domestic and abroad. In particular, The carbon fiber has high strength and ultra light property higher than stainless steel, aluminum, GFRP as Eco-friendly material. Carbon fiber contribute to improving the environmental effect such as fuel saving, expansion of loadage, reducing the exhaustion of carbon dioxide through the weight reduction of transport area. In addition, The carbon fiber is applied to the ship in the area of race yacht, luxury cruise boat as weight reduction and high added-value materials, but there is limited application for general boat because price of carbon fiber is very expensive. For the weight reduction of general boat hull, being used as structure materials, glass fiber and carbon fiber are applied to hull with form of hybrid composite materials, but application of domestic and research for development are incomlete. In this study, An evaluations of mechanical strength property and fatigue strength are performed on composite materials by hybrid weaving of glass fiber and carbon fiber and composite materials forming method by hybrid forming.

SHPB 시험 및 영상분석을 통한 고변형율 속도 하의 시멘트 복합체 물성 변화 평가 (Evaluation of Material Properties Variations of Cementitious Composites under High Strain Rate by SHPB Test and Image Analysis)

  • 조현우;이장화;민지영;박정준;문재흠
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.83-91
    • /
    • 2015
  • 충돌 또는 폭발 하중 하의 콘크리트는 정적 하중에서 가지는 재료물성과 다른 거동을 보이게 된다. 즉, 고변형율 하의 콘크리트의 재료물성은 크게 변화하게 되며, 이를 시험평가하기 위한 방법 중 압축강도와 관련된 시험법으로는 SHPB(Split Hopkinson Pressure Bar) Test가 있다. 그러나, SHPB Test는 금속과 같은 인성재료를 위해 개발된 시험방법으로서 취성재료인 콘크리트에 적용이 가능한지에 대한 검토가 추가적으로 필요하며, UHPC와 같은 섬유보강 초고성능 콘크리트에 대한 연구는 미미한 실정이다. 이에 본 연구에서는 콘크리트 시험체를 위해 제작된 SHPB Test 장비를 사용하여 일반 콘크리트 및 UHPC 시험체에 대한 시험평가를 수행하였으며, SHPB Test의 적용 적정성을 파악하기 위하여 초고속카메라를 활용한 변위영상 분석을 통한 검증을 수행하였다.

A TWO-YEAR STUDY OF IMPLANT RETAINED OVERDENTURES IN THE TREATMENT OF TOTALLY EDENTULOUS JAWS

  • Kwon, Ho-Beom;Kim, Eun-Ha;Lee, Seok-Hyoung
    • 대한치과보철학회지
    • /
    • 제45권6호
    • /
    • pp.760-768
    • /
    • 2007
  • Statement of problem. Conventional denture treatment for totally edentulous patients is associated with a variety of functional and psychosocial problems. The placement of implants in the anterior region of the maxilla and mandible and the fabrication of an implant-retained overdenture might solve these problems. Purpose. This study compared the marginal bone loss around the implant and evaluated the implant survival rate and complications in patients treated with overdentures retained by implants for 2 years. Material and methods. Patients who had received implant-retained overdentures using a Dolder bar at Samsung Medical Center from January 1999 to June 2005 and had participated in the annual recall programs for two years were selected for this study. A total of 18 patients and 56 $Br{\aa}ne-mark\;system^{(R)}$ implants were used, and their data were reviewed. Evaluations of the survival rate, bone quality, marginal bone loss, and complications were performed. The data on the Dolder bar length and clip length were measured. The change in marginal bone loss and the correlation between the marginal bone loss and bar length, clip length, or bone quality were investigated. Results. Implants placed in this study showed a 100% survival rate. The average annual bone loss was 1.12mm in the first year and 0.27mm in the second year in the maxilla, and 0.58mm in the first year and 0.22mm in the second year in the mandible. The marginal bone loss in the maxilla showed no significant association with those in the mandible. (P>.05). There was no significant difference in marginal bone loss around implants between the first and second year. (P>.05) There was no statistically significant relationship (P>.05) between the marginal bone loss and bone quality, clip length, or Dolder bar length. The Dolder bar length showed a high correlation with the clip length. (P<.05) Various complications were noted. Conclusion. These results confirmed the favorable outcome for patients treated with implant-retained overdentures.

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.