• 제목/요약/키워드: Material Condition

검색결과 5,688건 처리시간 0.036초

Thermal Reflow 공정 적용 Micro Pattern 형상 변화를 통한 광 향상 구조층 연구 (Study on Optical Control Layer for Micro Pattern Shape Change Using Thermal Reflow Process)

  • 성민호;차지민;문성철;유시홍;이성의
    • 한국전기전자재료학회논문지
    • /
    • 제28권5호
    • /
    • pp.306-313
    • /
    • 2015
  • In this study, the change of optical characteristics was studied according to the micro optical pattern provided by photo lithography followed by thermal reflow process. The shape and luminance variation with micro pattern was evaluated by SEM and spectrometers. Also, we analyzed the luminance characteristics using the 3D-optical simulation (Optis works) program. As a result, we found that the radius of curvature(R) in micro pattern is decreased up to 77%($150^{\circ}C$) compared to the radius of curvature at the condition $100^{\circ}C$, which is caused by efficient reflow of organic material without chemical changes. The highest enhancement of brightness with optimum micro pattern was obtained at the condition of $120^{\circ}C$ reflow process. The brightness gain with optical micro patterns is more than 15% at the condition of R=16.95 um, ${\Theta}=77.14^{\circ}$ compared to original optical source. The results of light simulation with various radius of curvature and side angle of pattern shows the similar result of experiment evaluation of light behavior on optical micro patterns. It is regarded that the more effect on light enhancement was contributed by side angle which is effective factor on light reflection, rather than the curvature of micro-patterns.

주기가열법을 이용한 탄소/에폭시 및 다공성 단열재의 진공 열확산도 측정 (Thermal Diffusivity Measurement of Carbon/Epoxy and Porous Thermal Insulation Material under Vacuum Condition Using Cyclic Heating Method)

  • 남기원;이영무;;공철원
    • Composites Research
    • /
    • 제20권5호
    • /
    • pp.20-25
    • /
    • 2007
  • 열주기법은 다공성 소재의 열확산도를 측정하는데 유용한 방법이다. 본 논문의 주 목적은 진공환경에서 다공성 소재의 열확산도 측정 시스템을 개발하고 검증하는데 있다. 이 방법을 검증하기 위하여 알루미나 시편과 폴리스티렌 폼의 열확산도를 측정하였다. 이 시편들의 열확산도는 참고값과 일치하였다. 탄소/에폭시 소재와 다공성 단열소재의 열확산도를 대기상온과 대기진공 환경에서 측정하였다. 탄소/에폭시 소재와 다공성 단열소재의 진공환경에서 열확산도는 대기환경에 비하여 각각 66.4%와 64.9% 감소하였다. 이 차이는 소재내의 기공에 있는 공기의 영향으로 추정된다.

PV 모듈용 EVA Sheet의 Lamination 공정 조건에 따른 태양전지 크랙발생 현상 관찰 (The observation of solar cell's micro-crack depending on EVA Sheet's lamination condition for photovoltaic module)

  • 강경찬;강기환;허창수;유권종
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.9-9
    • /
    • 2008
  • Recently, the thickness of solar cell gets thinner to reduce the quantity of silicon. And the reduced thickness make it easy to be broken while PV module fabrication process. This phenomenon might make PV module's maximum power and durability down. So, when using thin solar cell for PV module fabrication, it is needed to optimize the material and fabrication condition which is quite different from normal thick solar cell process. Normally, gel-content of EVA sheet should be higher than 80% so PV module has long term durability. But high gel-content characteristic might cause micro-crack on solar cell. In this experiment, we fabricated several specimen by varying curing temperature and time condition. And from the gel-content measurement, we figure the best fabrication condition. Also we examine the crack generation phenomenon during experiment.

  • PDF

Salt fog 시험에서 silicone rubber에서 발생하는 방전 전류의 특성 (The surface discharge performance of silicone rubber in the Salt fog test)

  • 강성화;박영국;이광우;김완수;이용회
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.565-569
    • /
    • 1999
  • In these days, the silicone insulators have been increasingly studied and applied for outdoor insulators because it has superior characteristics than porcelain and glass insulators, which have been used for outdoor insulators. First of all, The excellent performance of the silicone rubber in polluted and wet conditions is attributed to the ability of the material to maintain the hydrophobicity of the surface in the presence of severe contamination and wet conditions. This is because of the presence of low molecular weight mobile fluid in the silicone rubber which diffuses to the surface and to above the contamination layer. But, the leakage current and some surface discharge occurs on surface of the composite polymeric insulation materials when the insulator is used for a long time with severe contaminative condition and it can lead the contamination flashover. So the leakage current and the discharge current are important to estimate the condition of the silicone rubber surface. In this paper, the average leakage current, the relation of surface discharge current and phase angle were study to investigate electrical conduction of silicone rubber surface with the salt fog condition.

  • PDF

비율제한 및 과제제시방법에 따른 3, 4, 5세 유아의 비상징 수 비교능력 (An Investigation Into 3-, 4-, and 5-Year-Old Children's Nonsymbolic Magnitude Comparison Ability According to Ratio Limit and Task Condition)

  • 조우미;이순형
    • 아동학회지
    • /
    • 제38권1호
    • /
    • pp.117-126
    • /
    • 2017
  • Objective: The purpose of this study was to investigate young children's nonsymbolic magnitude comparison ability according to ratio limit and task condition. Methods: The participants included 40 3-year-old children, 42 4-year-old children, and 41 5-year-old children recruited from 4 childcare centers located in Seoul, Korea. All magnitude comparison tasks were composed of image material tasks and concrete material tasks. In addition, each magnitude comparison task varied with the ratio of the two quantities; 0.5 ratio, 0.67 ratio, 0.75 ratio. Results and Conclusion: The results revealed that 3-, 4-, and 5-year-old children could perform nonsymbolic magnitude comparison tasks without learning experiences. Also, 3-, 4-, and 5-year-old children could perform concrete material tasks better than image material tasks in nonsymbolic magnitude comparison tasks. Furthermore, children's performance on nonsymbolic magnitude comparison tasks indicated the ratio signature of the approximate number system. Children have a degree of numerical capacity prior to formal mathematics instruction. Also, children were influenced by task conditions or sense stimulus when they processed numerical information. Furthermore, the approximate number system can be used in understanding the ordinality of number.

Corrosive Wear of Alloy 690 Tubes in Alkaline Water

  • Hong, Seung Mo;Jang, Changheui;Kim, In Sup
    • Corrosion Science and Technology
    • /
    • 제8권3호
    • /
    • pp.126-131
    • /
    • 2009
  • The interaction between wear and corrosion can significantly increase total material losses in water chemistry environment. The corrosive wear tests of a PWR steam generator tube material (Alloy 690) against the anti vibration bar material (409 SS) were performed at room temperature. The tests were performed in alkaline water chemistry conditions. NaOH solution was selected for test condition to investigate the corrosive wear effect of steam generator tube material in alkaline pH condition without other factors. The flow induced vibration can caused tube damage and the corrosion can be occurred by water chemistry. The test results showed that, in the alkaline solution at pH 13.9, the corrosion current density was increased about ten times than that in the distilled water. And wear rate at pH 13.9 was increased about ten times from that at neutral condition. However, the wear rate was decreased with time. The decrease would be attributed to the change in roughness of specimen or sub-layer of the worn surface with time. From microstructure observation, severe abrasive shape and several wear debris were found. From those results, it could infer that the oxide film on Alloy 690 changed to easily breakable one in the alkaline water, and then abrasion with corrosion became the main wear mechanism.

The Study on the Effects of Air Pollution on the Material Damages in Northeast Asia

  • Kim, Sun-Tae;Yasuaki Maeda
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E2호
    • /
    • pp.51-61
    • /
    • 2003
  • The material exposure tests have been carried out since 1993 to evaluate the relationship between air pollution and material corrosion with the cooperation of the researchers in Japan, China, and Korea. The test pieces such as bronze, copper, marble, and carbon steel have been exposed under both unsheltered and rain-sheltered outdoor condition separately at 18 sampling sites in East Asia. At the same time, the concentration of SO$_2$ and NO$_2$ has been measured simultaneously with passive sampler. The meteorological data were collected from the AWS (Auto-mated weather station) In each country and chemical compositions of wet deposition were also analyzed by the bulk sampling of rainfall every month. As the results, it was found that the corrosion rates of test pieces in the ambient air were appeared to be in the order of carbon steel > marble > bronze copper. The corrosion rates of test pieces in the unsheltered outdoor condition were 2.34 to 5.88 times larger than those in rain-sheltered condition. It was also found that the corrosion rate in the heavy polluted area in China was the highest, and the corrosion rates of the metal pieces were generally proportional to SO$_2$ concentration. Between two sites in Korea, the test pieces at Daegu site showed higher corrosion rates that would be due to the higher SO$_2$ concentration.

MR Fluid Polishing을 이용한 Co-Cr-Mo alloy의 초정밀 연마 방법 (A Study on The Ultra-precision Polishing Method of Co-Cr-Mo alloy Using MR Fluid Polishing)

  • 신봉철;김병찬;송기혁;조명우
    • Design & Manufacturing
    • /
    • 제11권3호
    • /
    • pp.8-12
    • /
    • 2017
  • In general, metallic bio-materials is more widely used in solid tissue like bone or tooth than flexible tissue such as skin or muscle. Especially, Cobalt Chrome Molybdenum(Co-Cr-Mo), which is used in tooth surgery, has a great corrosion resistance. Because this bio-material is non-toxic in human body, and has a bio-compatibility that the vital reaction is not occurred with tissue in body. However the chemical reaction is occurred by fatal matter that deteriorate the property of material surface in conventional polishing, and it can affect to fatal disease in human body or decrease the material properties such as hardness, yield strength or bio-compatibility. This surface in poor condition can cause development of corrosion or bacteria. In this study, MR fluid polishing is used to minimize the scratch, pit or surface flaws generated in conventional polishing. Surface roughness is measured according to the polishing condition to obtain fine surface condition.

금속류 행정박물의 손상도 및 재질 연구 (Deterioration Degree and Material Research of Metal Archival Objects)

  • 박형호;조남철;나미선
    • 보존과학회지
    • /
    • 제26권1호
    • /
    • pp.33-41
    • /
    • 2010
  • 행정박물이란 공공업무의 활동을 반영하는 유형적 증거물로서 행정적 역사적 상징적 문화적 예술적 가치를 지니는 형상기록물이며 세계 여러 나라에서 제작되어 재질과 제작기법이 다양하지만, 재질조사 및 보존관리 시스템이 확립되지 않아 효율적인 보존관리의 어려움이 많다. 그러므로 본 연구에서는 금속류 행정박물에 대한 재질조사와 상태점검을 통하여 효율적인 보존관리를 위한 기초자료를 제시하고자 한다. 금속류 행정박물 중 상태점검 및 재질 분류는 공직자 선물 가운데 변색, 산화, 결손 및 균열이 기록된 12점을 선별하여 조사하였다. 행정박물의 전반적인 상태를 점검하기 위해 국내 박물관, 미술관 및 일본민족학박물관에서 사용하는 상태점검카드를 수집 정리하여 새로운 점검카드를 작성 후 금속류 행정박물을 점검하였다. X-ray를 통해 행정박물의 제작기법과 소재간의 결합방법, 구조상 취약부분에 대하여 조사하였으며 P-XRF를 사용하여 행정박물의 재질 분석을 시도하여 각 재질별 분류를 실시하였다. 점검결과 행정박물의 외형적 특성과 손상부분에 대한 점검이 가능하고 구조적으로 취약한 부분을 관찰 할 수 있었다. 또한 P-XRF 측정을 통하여 재질이 미상으로 기록된 행정박물의 재질을 밝혀내었고 기록카드에 기재된 재질과 다른 재질을 찾아낼 수 있었다. 행정박물의 상태점검 및 손상정도, 재질별 분류 방법은 향후 보존관리를 위한 자료로써 활용이 가능하며 재질에 따른 훼손 방지 및 관리를 위한 보존관리지침 수립 등 장기보존을 위한 기초자료로서도 활용이 가능한 것으로 보인다.

DC/RF Magnetron Sputter를 이용한 무반사 및 고반사 박막증착 (A thin film condition of material for AR and HR coating by the DC/RF Magnetron Sputter)

  • 양진석;조운조;이천;김동우;신춘교
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.206-209
    • /
    • 2003
  • The purpose of AR and HR coating is acquire the very low reflection rate and the high reflection rate through the deposition of a thin film using the refraction ofmaterial. Basically if the high refractive material and the low refractive material are chosen and the condition for the experiment is determined, then we solve theproject with the optical design and multi thin film coating. First of all, we choose $SiO_2$for the low refractive material and $TiO_2$ for the high refractive material and apply Sputtering System easy to control the refraction rate and excellent in reconstruction to the equipment of thin film multiplication. For the control of the refraction rate and growth rate we modify RF Power and the ratio of Gas(Ar:O2), And we use Ellipsometer for estimation and analysis of the refraction rate and growth rate and AFM&SEM for the analysis of surface and component.

  • PDF