• Title/Summary/Keyword: Master-Pipe

Search Result 12, Processing Time 0.021 seconds

Implementation of CAM Program for 6-Axis CNC Pipe Coaster (6축 CNC 파이프 코스터 전용 CAM 프로그램 구현)

  • Lho, Tae-Jung;Lee, Wook-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2202-2209
    • /
    • 2009
  • Joint paths are induced mathematically for many kinds of joint pattern between master- and sub-pipes. By compensating them with root gap of welds and kerf width, real cutting paths are determined. Their NC codes are generated, and the paths generated by NC code are verified by a ghost function. A beveling is implemented through tilting a torch in the A- and B-axis direction for 8 sections in the chuck rotation of C-axis. The effective CAM program was developed specially for 6-axis CNC pipe coasters which cut a master or sub- pipe along the cutting path and simultaneously fulfill a beveling process.

A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters (2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구)

  • Choi Jong Oh;Lee Woan Kyu;Lim Ki Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

'Master Character Set-up' for Effective Management of 3D Animation Pipe Line (애니메이션 효율적 공정관리를 위한 캐릭터 셋업)

  • Chae, Eel-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.4
    • /
    • pp.133-140
    • /
    • 2007
  • The current 3D CG animation pipe line, which is the production system, does not have an effective solution that all animation departments are able to start their jobs independently against other animation departments. It is generally acknowledged that we could not do animating task before the modeling and set-up task. This kind of process has caused loss of labour. We could expect lasting problems which is stopping marking animating process before the previous process done again in case of requiring editing the jobs which are modeling and set-up. We could solve these "bottleneck" situation with "master character" defined as standard, so that animate and retake the job independently against other departments. These new process could accelerate the animation pipe line system.

On the Development of Pipe Equipment in 3D Ship CAD (3차원 선박 CAD를 위한 배관 의장품의 Part Master 정보 구축)

  • Lee, Jang-Hyun;Lee, Hwang-Beom;Hwang, Se-Yun;Ha, Sung-Cook;Lee, Chan-Woo
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.819-824
    • /
    • 2007
  • Outfitting system in ship design has huge kinds of standard part. Data base of and automatic design procedure of part master should be included in ship cad in order to reduce the design time. Present study shows an process of part master DB construction of pipe equipments using 3-dimensional CAD environment Attribute and properties of part masters are chosen from JIS standard. As the schema of part masters are stored in data base, 3D geometric model is parsed from the schema.

  • PDF

Development of Automatic 3-Axis Pipe Profile-Cutting System with Bevelling of Welds Using PLC (PLC를 이용하여 궤적절단과 동시에 용접부 개선이 가능한 자동 3축 파이프 형상절단 시스템 개발)

  • Lho, Tae-Jung;Kim, Hwa-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3066-3073
    • /
    • 2009
  • Joint paths of master and branch pipes are induced mathematically for many kinds of joint patterns between both pipes in 3-axis pipe profile-cutting machines. By compensating them with a kerf width, the real cutting paths are determined, and their CL-data are generated, and the tool paths generated by CL-data are verified by a ghost function. A bevelling of welds is implemented through tilting a cutting torch in the $\beta$-axis direction for 8 sections in the chuck rotation of $\alpha$-axis. A PLC controls simultaneously position and velocity in a real time for $\alpha$, X, $\beta$-axis by loading CL-data generated. We developed the PLC-controlled 3-axis pipe profile-cutting system which can cut a master or branch pipe along the cutting path and simultaneously do a bevelling process.

An Application of Catalogue Database for the Modeling of Pipe Parts in Ship Design (카탈로그 데이터베이스를 이용한 선박 배관부품의 효과적인 모델링 절차 개발 사례)

  • Hwang, Se-Yun;Lee, Jang-Hyun;Kim, Seung-Hyun;Kim, Kwang-Sik;Lee, Sung-Je
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.1
    • /
    • pp.60-69
    • /
    • 2010
  • Outfitting systems in marine vessels have many kinds of standard parts. Ship CAD system should support the designers with an efficient tool for the modeling of outfitting parts such as pipes and valves. We develop a practical procedure for a part master model that combines ship CAD systems with the industrial standard. Part master or catalogue database of standard equipments is included in the database of ship CAD. The part master makes the associations of three dimensional modeling with the industrial standard. Moreover, it reflects the automatic modeling to maintain attributes that are disclosed in the entity of each part master in order to reduce the modeling time. Entity and attributes of pipe and valves are chosen from JIS(Japanese Industrial Standards) in order to explain the proposed procedure. Suggested procedure explains that three dimensional model of equipment is generated by parsing the pre-defined attributes after the entities of part masters is stored in database.

Flow Range Extension of Light Oil Flowmeter Standard System with Build-Up Technique (Build-Up 기법을 이용한 경질유 표준장치의 측정범위 확장)

  • Lim, Ki-Won;Choi, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.12 s.255
    • /
    • pp.1139-1146
    • /
    • 2006
  • Light Oil Flow Standard System(LOFSS) in Korea Research Institute of Standards and Science(KRISS) was designed for oil flowmeter calibration. In order to extend the flow range from 120 $m^3/h$ to 200 $m^3/h$, the build-up technique was applied with two positive displacement flowmeters as master flowmeter. The master flowmeters were calibrated against with LOFSS, which has 0.04 % uncertainty of flow quantity determination, then the test flowmeter is calibrated against two master flowmeters. For uncertainty analysis, the repeatability of master flowmeters, the variation of the fluid density and the pipe volume due to temperature change were scrutinized. The contribution of each uncertainty factors to the calibrator and the correlation of each factors were discussed. For investigating the feasibility of uncertainty analysis, a turbine flowmeter as a transfer package was tested with LOFSS and two reference flowmeter. The hypothesis test for both results was coincide with a 95 % significant level. This means that the uncertainty analysis procedure of the calibrator is reasonable and the extension of flow range with master meters was carry out successfully.

Low-cycle fatigue evaluation for girth-welded pipes based on the structural strain method considering cyclic material behavior

  • Lee, Jin-Ho;Dong, Pingsha;Kim, Myung-Hyun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.868-880
    • /
    • 2020
  • One of the main concerns in the structural integrity of offshore pipelines is mechanical damage from external loads. Pipelines are exposed to fatigue failure in welded joints due to geometric discontinuity. In addition, fatigue loads such as currents, waves, and platform motions may cause significant plastic deformation and fracture or leakage within a relatively low-cycle regime. The 2007 ASME Div. 2 Code adopts the master S―N curve for the fatigue evaluation of welded joints based on the mesh-insensitive structural stress. An extension to the master S―N curve was introduced to evaluate the low-cycle fatigue strength. This structural strain method uses the tensile properties of the material. However, the monotonic tensile properties have limitations in describing the material behavior above the elastic range because most engineering materials exhibit hardening or softening behavior under cyclic loads. The goal of this study is to extend the cyclic stress-strain behavior to the structural strain method. To this end, structural strain-based procedure was established while considering the cyclic stress-strain behavior and compared to the structural strain method with monotonic tensile properties. Finally, the improved prediction method was validated using fatigue test data from full-scale girth-welded pipes.

BEPU analysis of a CANDU LBLOCA RD-14M experiment using RELAP/SCDAPSIM

  • A.K. Trivedi;D.R. Novog
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1448-1459
    • /
    • 2023
  • A key element of the safety analysis is Loss of Coolant Analysis (LOCA) which must be performed using system thermal-hydraulic codes. These codes are extensively validated against separate effect and integral experiments. RELAP/SCDAPSIM is one such code that may be used to predict LBLOCA response in a CANDU reactor. The RD-14M experiment selected for the Best Estimate Plus Uncertainty study is a 44 mm (22.7%) inlet header break test with no Emergency Coolant Injection. This work has two objectives first is to simulate pipe break with RELAP and compare these results to those available from experiment and from comparable TRACE calculations. The second objective is to quantify uncertainty in the fuel element sheath (FES) temperature arising from model coefficient as well as input parameter uncertainties using Integrated Uncertainty Analysis package. RELAP calculated results are found to be in good agreement with those of TRACE and with those of experiments. The base case maximum FES temperature is 335.5 ℃ while that of 95% confidence 95th percentile is 407.41 ℃ for the first order Wilk's formula. The experimental measurements fall within the predicted band and the trends and sensitivities are similar to those reported for the TRACE code.

Intercomparison of Light Oil Flow Standard System for the Reliability of Measurement Accuracy (경질유 유량표준장치의 신뢰도 검증을 위한 측정정확도 비교)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.9
    • /
    • pp.712-719
    • /
    • 2008
  • Light Oil Flow Standard System(LOFSS), as a national oil flow standard system, in Korea Research Institute of Standards and Science(KRISS) was developed for oil flowmeter calibration, and the expanded uncertainty of flow quantity determination was estimated within 0.04 %. In order to improve the reliability of the LOFSS measurement, a proficiency test was carried out in the flow range of 20 and $240\;m^3/h$ (Reynolds number $20,000{\sim}900,000$). A turbine flowmeter was used as a transfer package in round robin test. The water flow standard system of KRISS, the pipe prover of the national calibration and test organization and the master meter calibrator of the turbine flowmeter supplier, which used the different working fluid respectively, were compared with the turbine flowmeter measurement. The maximum difference of measurement was 0.15 % between the LOFSS and the pipe prover. The En numbers of the each system measurement were evaluated at the same Reynolds number. It was found that the En numbers were less than 1 in the comparison, which means the procedures of the uncertainty estimation of the each calibrators were reasonable and reliable.