• Title/Summary/Keyword: Mass spectrometer

Search Result 729, Processing Time 0.059 seconds

A Carbon Nanotube Field Emitter with a Triode Configuration for a Miniature Mass Spectrometer (초소형 질량분석기를 위한 삼극관 구조의 탄소나노튜브 전자방출원)

  • Lee, Yu-Ri;Lee, Ki-Jung;Hong, Nguyen Tuan;Lee, Soon-Il;Yang, Sang-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1001-1006
    • /
    • 2012
  • This paper presents a carbon nanotube (CNT) triode-structure field emitter as an ion source in a micro time-of-flight mass spectrometer(TOF-MS). In the ion source by field emission, the electrons emitted from cathodes under an electric field accelerated to the anode and ionize gas molecules by impact before arriving the anode. The generated positive ions are to be accelerated to the ion collector. Whereas most of ions are drawn to the cathodes in diode field emitters, a grid in the triode field emitter prevents the ions from being drawn to the cathodes. The triode field emitter is fabricated by micromachining. The cathode is composed of six CNT cylinders. The total size of the fabricated device is $8.0{\times}7.3{\times}1.9mm^3$. The anode and the grid current of the fabricated CNT field emitter were measured for various anode and grid voltages. When the anode and the grid voltages are 1000 V and 990 V, respectively, the emission current passing through the ionization region is 8.6 ${\mu}A$, which is a sufficient emission current for ionization and mass spectrometry.

Construction of an Improved Tandem Time-of-flight Mass Spectrometer for Photodissociation of Ions Generated by Matrix-assisted Laser Desorption Ionization (MALDI)

  • Moon, Jeong-Hee;Yoon, So-Hee;Kim, Myung-Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.5
    • /
    • pp.763-768
    • /
    • 2005
  • An improved tandem time-of-flight (TOF) mass spectrometer for the photodissociation (PD) study of ions generated by matrix-assisted laser desorption ionization (MALDI), MALDI-TOF-PD-TOF, has been designed and constructed. Recording a full spectrum with better than unit mass resolution even in low mass range has been achieved without reflectron voltage stepping which was needed in the previous version. Other aspects of the improvement, such as those in the data system which now allow 10-100 times faster spectral acquisition than with the previous instrument, are described. Rationale for the ideas which have led to the improvements is presented also.

Analytical Characteristics and Applications of Laser Ionization Mass Spectrometry

  • 임훙선;윤하섭;김성규
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.1
    • /
    • pp.32-37
    • /
    • 1997
  • We have built a laser ionization mass spectrometer (LIMS) for chemical composition analysis of solid samples, which employs an Nd:YAG laser and a time-of-flight mass analyzer. In this spectrometer, the maximum mass we identified clearly is higher than 2000 amu. A mass resolution of 230 has been achieved at m/z 208 (Pb element) in the linear TOFMS and can be even improved up to 1550 by employing a reflectron. The detection limit is determined to be on the order of ppm for Fe and In. The depth resolution is found to be about 20Å/spectrum with a laser power of 0.5 J/cm2. We also report a preliminary application of the LIMS to identifying impurities resident in several solid samples.

Study on increasing the mass resolution in aerosol TOF mass spectrometer by using post focusing method (후집속 방법을 이용한 에어로졸 TOF 질량분석기의 질량분해능 향상 연구)

  • Kim, Dukhyeon;Yang, Kiho;Cha, Hyungki;Kim, Dohoon;Lee, Sang Chun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.483-490
    • /
    • 2005
  • Mass resolution of the time of flight aerosol mass spectrometer for an aerosol component analysis depends on the initial direction and the initial energy of the ions. We have found that the shape of the optimum post focusing electric field is not linear. The maximum electric potential should be applied to the ions whose initial direction is 90 degree. To check on the post focusing effects, we have installed a laser ablation mass spectrometer. By using this LA-MS, we have found that the average energy distribution of the laser ablated ions is 8 eV. To establish the optimum mass resolution, a time delay and a high voltage are needed, and the results of the study show that 1500 nsec, and 3.7 kV are the optimum parameters for our system respectively. The isotope mass signals of copper show a good resolution.

Development of Remote Data Analysis System for the Joint Use of Equipments (분석기기지원을 위한 원격 데이터 분석 시스템 개발)

  • 최인식
    • Journal of Korea Technology Innovation Society
    • /
    • v.2 no.3
    • /
    • pp.94-106
    • /
    • 1999
  • In Korea Basic Science Institute(KBSI) the remote data analysis system is developed for the joint use of advanced equipments. This system enables the researchers to access the datas which are produced at KBSI and analyse them by Java program on the Web,. Except Web browser such as Internet Explorer or Netscape Navigator no additional softwares are required for analysing data. We have developed remote data analysis systems for five major equipments which KBSI supports for the researchers, The systems which are developed are those for NMR spectrometer High Reso-lution Tandem mass Spectrometer Microscopic Imaging System DNA Sequencer and Natural Ra-dioactivity Measruement System, These programs work on any computer platform and any operat-ing system only if the internet is available. This remote data analysis system will be served as a part of Collaboratory the remote collaborative system.

  • PDF

Analysis of Chemical Accident-Causing Substances Using a Proton Transfer Reaction-Time of Flight Mass Spectrometer (양자전이 비행시간 질량분석기를 이용한 화학사고 원인물질 분석)

  • Kim, So-Young
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.80-86
    • /
    • 2019
  • In Korea, a total of 556 chemical accidents occurred from 2012 to 2018 caused by adverse reactions of two or more chemicals, which required significant amounts of time to identify the causative chemicals. Rapid analysis is required for effective incident response and probing. In this study, a quantum transition time-of-flight mass spectrometer was used to identify the causative agents of chemical accidents caused by adverse reactions. The analyzer enabled fast real-time analysis without the need for sample collection and pretreatment. Quantitative and qualitative analysis of most volatile organic compounds with high hydrogen affinity was performed to investigate the cause of the chemical accidents. In fact, in the month of 201◯, methanol and toluene were detected as causative agents of the accident using a quantum transition time mass spectrometer, and were also the cause of the reported odor.

Analysis of Binding Trimethylamine with Rice-washed Solution using Electronic Nose Based on Mass Spectrometer (Mass spectrometer 기반의 전자코를 이용한 트리메틸아민과 쌀뜨물간의 결합 분석)

  • Hong, Eun-Jeung;Son, Hee-Jin;Kang, Jin-Hee;Noh, Bong Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.509-514
    • /
    • 2009
  • The effectiveness of a technique for binding rice-washed solution with trimethylamine (TMA) was investigated in this study. The mixtures of TMA and rice-washed solution were quantified using an electronic nose based on the mass spectrometer. After 7 min of reaction in a model system, the binding of TMA to the rice-washed solution was detected. As the concentration of rice-washed solution increased, the levels of TMA detected in the headspace decreased, thereby indicating an increase in the binding of TMA to the rice-washed solution. The binding effect of the rice-washed solution was comparable to those of starch, ${\alpha}$-cyclodextrin, or amylose, and superior to that of flour. The results of this study demonstrate the potential for reduction of off-flavors using the rice-washed solution.

Discrimination of Geographical Origin of Beef Using Electronic Nose Based on Mass Spectrometer (질량분석기가 연결된 전자코를 사용한 쇠고기의 원산지 판별)

  • Lim, Chae-Lan;Son, Hee-Jin;Hong, Eun-Jeung;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.717-720
    • /
    • 2008
  • In this study, the geographical origin of beef was studied using an electronic nose based on mass spectrometer. Domestic beef was compared with the imported beef from New Zealand and Australia. Each sample was analyzed, and discriminant function analysis was used utilized for the discrimination of geographical origin. The $R^2$ and F-value of discriminant function analysis (DFA)1 were 0.4317 and 14.18, respectively when the samples were separated by geographical origin. The $R^2$ and F-value of DFA1 were 0.8960 and 22.98, respectively when the samples were separated by part of beef.

Development of a Residual Gas Analyzer Calibration System (잔류기체 분석기 교정장치 개발)

  • Hong, S.S.;Lim, I.T.;Kim, J.T.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.91-98
    • /
    • 2007
  • The Korea Research Institute of Standards and Science (KRISS) has developed a residual gas analyzer (RGA) calibration system and measured gas sensitivities for two different types QMSs using nitrogen, argon, and helium. Different gas sensitivities were identified according to mass and pressure, so it was revealed that the gas sensitivity correction is necessary for proper use of mass spectrometers.