• 제목/요약/키워드: Mass Efficiency

검색결과 1,886건 처리시간 0.028초

A Real-Time DSP-Based Imbalance Analysis System for Rotating Machine with Vibration Signal

  • Su Hua;Huang Linglong;Chong Kil To
    • Journal of Mechanical Science and Technology
    • /
    • 제19권6호
    • /
    • pp.1243-1252
    • /
    • 2005
  • This paper describes a new digital signal processor (DSP) imbalance measurement system dedicated to real-time vibration analysis on rotating machine. To accomplish real-time analysis, the vibration signals are on-line acquired and processed to analyze the mass imbalance and phase position. This is achieved through the use of FFT and Lissajous diagram. The method followed to analyze the mass imbalance with the chosen hardware and software solutions are described in detail in this paper. Several experimental tests demonstrate the efficiency and accuracy in imbalance analysis performance of the DSP system.

Optimal design of wind-induced vibration control of tall buildings and high-rise structures

  • Li, Qiusheng;Cao, Hong;Li, Guiqing;Li, Shujing;Liu, Dikai
    • Wind and Structures
    • /
    • 제2권1호
    • /
    • pp.69-83
    • /
    • 1999
  • The most common used control device on tall buildings and high-rise structures is active and passive tuned mass damper (ATMD and TMD). The major advantages of ATMD and TMD are discussed. The existing installations of various passive/active control devices on real structures are listed. A set of parameter optimization methods is proposed to determine optimal parameters of passive tuned mass dampers under wind excitation. Simplified formulas for determining the optimal parameters are proposed so that the design of a TMD can be carried out easily. Optimal design of wind-induced vibration control of frame structures is investigated. A thirty-story tall building is used as an example to demonstrate the procedure and to verify the efficiency of ATMD and TMD with the optimal parameters.

The dynamic relaxation method using new formulation for fictitious mass and damping

  • Rezaiee-Pajand, M.;Alamatian, J.
    • Structural Engineering and Mechanics
    • /
    • 제34권1호
    • /
    • pp.109-133
    • /
    • 2010
  • This paper addresses the modified Dynamic Relaxation algorithm, called mdDR by minimizing displacement error between two successive iterations. In the mdDR method, new relationships for fictitious mass and damping are presented. The results obtained from linear and nonlinear structural analysis, either by finite element or finite difference techniques; demonstrate the potential ability of the proposed scheme compared to the conventional DR algorithm. It is shown that the mdDR improves the convergence rate of Dynamic Relaxation method without any additional calculations, so that, the cost and computational time are decreased. Simplicity, high efficiency and automatic operations are the main merits of the proposed technique.

곡유로 채널을 가지는 수증기-메탄올 개질기에서 유량 변화에 따른 메탄올 전환율 및 물질 전달에 관한 연구 (Study on Methanol Conversion Efficiency and Mass Transfer of Steam-Methanol Reforming on Flow Rate Variation in Curved Channel)

  • 장현;박인성;서정세
    • 대한기계학회논문집B
    • /
    • 제39권3호
    • /
    • pp.261-269
    • /
    • 2015
  • 본 연구에서는 전산유체역학 상용 코드를 이용하여 곡유로 채널형 수소 개질기에 대한 수치 해석적 연구를 수행하였다. 상용코드에서 제공하는 연소모델의 사전 검증을 위하여 원통 채널형 개질기 형를 가지는 선행연구모델(23)에 대한 수치해석을 선행하여 수행하였고, 95% 이상 일치하는 결과를 얻을 수 있었다. 선행연구모델의 수치해석을 통해 연소모델에 대한 해석 타당성검증이 완료된 후, 반응기 형태 변화가 메탄올 전환율과 수소생성에 미치는 영향을 파악하여 기존보다 유로의 길이가 증가한 곡유로 채널형 개질기를 설계하고, 유량조건($10/15/20{\mu}l/min$)을 변수로 수치해석을 수행하였다. 그 결과 원통 채널형 개질기와 곡유로 채널형 개질기에서 발생하는 유동 특성 및 물질전달 특성을 파악할 수 있었고, 그리고 유량에 따른 메탄올 전환율 및 수소 생성에 관한 유용한 정보를 얻을 수 있었다.

소규모 염색공장 폐수의 처리에 관한 연구 (A Study on the Treatment of Wastewater from Small-scale dyehouse)

  • 이준현;허항록;김광진;김민영;신재영
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2002년도 춘계 국제 학술대회
    • /
    • pp.23-25
    • /
    • 2002
  • This study was conducted to understand characteristics of wastewater which is discharged from small-scale dyehouse located in Seoul downtown area and to Find the appliable treatment method on the spot. The results of this study were summarized as followings. 1. The method which is used at present is mostly flocculation by coagulant or fenton oxidation. But the treatment efficiency of them are not good. 2. The results of fenton oxidation experiment demonstrated that treatment efficiency of COD was limited, which showed the need of the additional process or the improvement of existing treatment method, while the color was reduced considerably in optimal condition. 3. The optimal condition of fenton oxidation are as followings. -Feasible pH was in the 3∼4 regardless of the kinds of iron ions, But the fluctuation of treatment efficiency with the change of pH was small - The mass ratio of H$_2$O/CODcr was used to evaluate the parameter of H$_2$O$_2$ The optimal range of this was in 0.7∼1,3 and it was observed that the ratio got higher as the quality got worse. -For iron ion, FeCl$_2$4H$_2$O turned out to be more effective for removal of color compared with was compared FeSO$_4$7H$_2$Oin. the mass ratio of Fe/H$_2$O$_2$ of 2.3∼2.8 for of FeSO$_4$7H$_2$O and 1.6∼1.8 for FeCl$_2$4H$_2$O resulted in good treatment efficiencies. 4. With adsorption process applied before fenton oxidation in order to treat the high concentration wastewater, the treatment efficiency increased by 61% in CODcr, 55% in color. and if the power activated carbon is injected in more than 2500mg/$\ell$, the wastewater can be treated within the effluent quality criteria.

  • PDF

복합형 태양열 가열기의 일일 운전 특성 및 축열 성능에 관한 연구 (A Study on Thermal Storage Performance and Characteristics of Daily Operation of a Hybrid Solar Air-Water Heater)

  • 최휘웅;파쿠르 로커만;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.73-79
    • /
    • 2015
  • In this study, a thermal storage performance and characteristics of daily operation were investigated when the air and the liquid were heated simultaneously by a hybrid solar air-water heater that can make hot water as well as heated air. The hybrid solar air-water heater is kind of a flat plate solar collector that can make hot water and heated air by installing air channel beneath absorber plate of traditional flat plate solar collector for hot water. As a result of daily operation, maximum water temperature reached in a thermal storage was shown $44^{\circ}C$ on 73kg/h of air mass flow rate and about $40^{\circ}C$ on 176kg/h of air mass flow rate. Thus, the necessity of heating water in thermal storage by operating only liquid side was confirmed when the temperature of liquid in thermal storage is lower than we need. In case of efficiency investigated on daily operation, the thermal efficiency of the liquid side was decreased with increment of the inlet liquid temperature and decrement of the solar radiation, but efficiency of the air side was increased with increment of inlet liquid temperature difference as the traditional solar air heater. Total thermal efficiency of the collector was shown from 65.85% to 78.23% and it was decreased with increment of the inlet liquid temperature and decrement of solar radiation same as the traditional system.

Multiple Pounding Tuned Mass Damper (MPTMD) control on benchmark tower subjected to earthquake excitations

  • Lin, Wei;Lin, Yinglu;Song, Gangbing;Li, Jun
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.1123-1141
    • /
    • 2016
  • To explore the application of traditional tuned mass dampers (TMDs) to the earthquake induced vibration control problem, a pounding tuned mass damper (PTMD) is proposed by adding a viscoelastic limitation to the traditional TMD. In the proposed PTMD, the vibration energy can be further dissipated through the impact between the attached mass and the viscoelastic layer. More energy dissipation modes can guarantee better control effectiveness under a suite of excitations. To further reduce mass ratio and enhance the implementation of the PTMD control, multiple PTMDs (MPTMD) control is then presented. After the experimental validation of the proposed improved Hertz based pounding model, the basic equations of the MPTMD controlled system are obtained. Numerical simulation is conducted on the benchmark model of the Canton Tower. The control effectiveness of the PTMD and the MPTMD is analyzed and compared under different earthquake inputs. The sensitivity and the optimization of the design parameters are also investigated. It is demonstrated that PTMDs have better control efficiency over the traditional TMDs, especially under more severe excitation. The control performance can be further improved with MPTMD control. The robustness can be enhanced while the attached mass for each PTMD can be greatly reduced. It is also demonstrated through the simulation that a non-uniformly distributed MPTMD has better control performance than the uniformly distributed one. Parameter study is carried out for both the PTMD and the MPTMD systems. Finally, the optimization of the design parameters, including mass ratio, initial gap value, and number of PTMD in the MPTMD system, is performed for control improvement.

STARBURST AND AGN CONNECTIONS AND MODELS

  • SCOVILLE NICK
    • 천문학회지
    • /
    • 제36권3호
    • /
    • pp.167-175
    • /
    • 2003
  • There is accumulating evidence for a strong link between nuclear starbursts and AGN. Molecular gas in the central regions of galaxies plays a critical role in fueling nuclear starburst activity and feeding central AGN. The dense molecular ISM is accreted to the nuclear regions by stellar bars and galactic interactions. Here we describe recent observational results for the OB star forming regions in M51 and the nuclear star burst in Arp 220 - both of which have approximately the same rate of star formation per unit mass of ISM. We suggest that the maximum efficiency for forming young stars is an Eddington-like limit imposed by the radiation pressure of newly formed stars acting on the interstellar dust. This limit corresponds to approximately 500 $L_{\bigodot} / M_{\bigodot}$ for optically thick regions in which the radiation has been degraded to the NIR. Interestingly, we note that some of the same considerations can be important in AGN where the source of fuel is provided by stellar evolution mass-loss or ISM accretion. Most of the stellar mass-loss occurs from evolving red giant stars and whether their mass-loss can be accreted to a central AGN or not depends on the radiative opacity of the mass-loss material. The latter depends on whether the dust survives or is sublimated (due to radiative heating). This, in turn, is determined by the AGN luminosity and the distance of the mass-loss stars from the AGN. Several AGN phenomena such as the broad emission and absorption lines may arise in this stellar mass-loss material. The same radiation pressure limit to the accretion may arise if the AGN fuel is from the ISM since the ISM dust-to-gas ratio is the same as that of stellar mass-loss.

고압나트륨등 조사가 파프리카의 동적 생장과 건물분배율에 미치는 영향 (Effects of the High Pressure Sodium Lamp Lighting on the Dynamics of Growth and Dry Mass Partitioning in Sweet Pepper Plant)

  • 김은정;이상현;이정현
    • 원예과학기술지
    • /
    • 제31권5호
    • /
    • pp.565-572
    • /
    • 2013
  • 본 연구의 목적은 고압나트륨등 광원(HPS)을 조사하여 파프리카의 동적생장과 기관별 건물분배율 및 광이용효율에 미치는 효과를 구명하고자 수행하였다. 파프리카 육묘는 2010년 9월 29일에 $m^2$당 3.75주를 정식하여 2010년 12월 14일부터 HPS 광원을 실험종료일까지 하루 16시간 조사하였다. HPS 처리는 엽수를 증가시켰으나, 절간수와 엽면적에는 미비한 영향을 미쳤다. HPS 처리구의 초장은 대조구에 비해 짧았으나, 줄기당 착과수의 증가를 나타냈다. 줄기와 과실 및 총건물중은 HPS 처리구가 대조구보다 각각 28.5%, 97.1%, 67.8%를 증가시켰다. 총 건물중의 증가율 대비 엽과 줄기 생장율을 비율로 나타낸 각 기관의 건물분배율은 생육초기에 45-47%로 동일하다가 과실의 생장이 시작되는 시점에서 급격히 감소하였다. 영양생장기관으로의 건물분배율은 대조구에서 HPS 처리구보다 4% 높았다. 과실로의 평균 건물 분배율을 HPS 처리구에서 대조구에 비해 14.2% 증가하였다. 동적생장량은 지수선형함수의 최대상대생장율, 최대 절대생장율 및 손실일수로 잘 묘사할 수 있었다. 대조구에 비해 처리구의 엽의 최대절대생장율은 18.6%, 줄기는 74.7%, 과실은 143.5%가 증가하는 것으로 추정되었다. 총 건물중에 대한 광이용효율(LUE)은 HPS 처리구에서 $4.90g{\cdot}MJ^{-1}$로 대조구의 $3.84g{\cdot}MJ^{-1}$ 높았으며, 영양생장기관의 LUE는 HPS 처리구가 $1.56g{\cdot}MJ^{-1}$로 대조구의 $1.61g{\cdot}MJ^{-1}$보다 약간 낮았으며, 과실 생산에 대한 LUE는 처리구가 $3.34g{\cdot}MJ^{-1}$로 대조구 $2.23g{\cdot}MJ^{-1}$보다 49.8% 증가하였다. 처리간 총 건물중의 LUE의 차이는 HPS 처리구의 과실생산에 대한 LUE가 높았기 때문에 발생되었다.

ORC 시스템의 운전 특성에 관한 실험연구 (Experimental Study on the Operating Characteristics of the Organic Rankine Cycle)

  • 엄홍선;윤천석;김영민
    • 설비공학논문집
    • /
    • 제25권4호
    • /
    • pp.208-215
    • /
    • 2013
  • An experimental study of an ORC (Organic Rankine Cycle) system has been performed for small-scale applications in the range of a few kW for low-grade-recovery heat sources. The ORC system was equipped with a scroll expander. Experimental tests were carried out using this system, and showed good performance and reliability for the small-scale system. The effects of various operating conditions were selected as the main parameters for the performance of ORC system, such as the expander speeds and mass flow rates of R-134a for expander inlet temperatures ranging from $100^{\circ}C$ to $190^{\circ}C$, as well as the thermal power, thermal efficiency, expansion efficiency, and volumetric efficiency.