• Title/Summary/Keyword: Manual Measurement

Search Result 453, Processing Time 0.031 seconds

Inferring Pedestrian Level of Service for Pathways through Electrodermal Activity Monitoring

  • Lee, Heejung;Hwang, Sungjoo
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.1247-1248
    • /
    • 2022
  • Due to rapid urbanization and population growth, it has become crucial to analyze the various volumes and characteristics of pedestrian pathways to understand the capacity and level of service (LOS) for pathways to promote a better walking environment. Different indicators have been developed to measure pedestrian volume. The pedestrian level of service (PLOS), tailored to analyze pedestrian pathways based on the concept of the LOS in transportation in the Highway Capacity Manual, has been widely used. PLOS is a measurement concept used to assess the quality of pedestrian facilities, from grade A (best condition) to grade F (worst condition), based on the flow rate, average speed, occupied space, and other parameters. Since the original PLOS approach has been criticized for producing idealistic results, several modified versions of PLOS have also been developed. One of these modified versions is perceived PLOS, which measures the LOS for pathways by considering pedestrians' awareness levels. However, this method relies on survey-based measurements, making it difficult to continuously deploy the technique to all the pathways. To measure PLOS more quantitatively and continuously, researchers have adopted computer vision technologies to automatically assess pedestrian flows and PLOS from CCTV videos. However, there are drawbacks even with this method because CCTVs cannot be installed everywhere, e.g., in alleyways. Recently, a technique to monitor bio-signals, such as electrodermal activity (EDA), through wearable sensors that can measure physiological responses to external stimuli (e.g., when another pedestrian passes), has gained popularity. It has the potential to continuously measure perceived PLOS. In their previous experiment, the authors of this study found that there were many significant EDA responses in crowded places when other pedestrians acting as external stimuli passed by. Therefore, we hypothesized that the EDA responses would be significantly higher in places where relatively more dynamic objects pass, i.e., in crowded areas with low PLOS levels (e.g., level F). To this end, the authors conducted an experiment to confirm the validity of EDA in inferring the perceived PLOS. The EDA of the subjects was measured and analyzed while watching both the real-world and virtually created videos with different pedestrian volumes in a laboratory environment. The results showed the possibility of inferring the amount of pedestrian volume on the pathways by measuring the physiological reactions of pedestrians. Through further validation, the research outcome is expected to be used for EDA-based continuous measurement of perceived PLOS at the alley level, which will facilitate modifying the existing walking environments, e.g., constructing pathways with appropriate effective width based on pedestrian volume. Future research will examine the validity of the integrated use of EDA and acceleration signals to increase the accuracy of inferring the perceived PLOS by capturing both physiological and behavioral reactions when walking in a crowded area.

  • PDF

A Experimental Study on the Stiffness Characteristics of Elastomeric Bearings (탄성받침의 강성특성에 대한 실험연구)

  • Yoon, Hyejin;Cho, Changbeck;Kim, Youngjin;Kwahk, Imjong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.475-485
    • /
    • 2008
  • This paper intends to enhance the reliability and performance of domestic elastomeric bearings through the proposal of directions for the improvement of their stiffness regard to the Korean industrial standard KS F 4420 relative to the evaluation of design/fabrication/quality. Therefore, comparative analysis of the compressive elastic modulus, stiffness measurement method and performance evaluation method of KS F 4420 with those of Eurocode, Japanese bearing manual, and ISO code was performed, and measurement tests on the compressive stiffness and shear stiffness of common elastomeric bearings produced in Korea were conducted. The experimental results reveal that differences of about 20% and 13% occurred respectively for the compressive stiffness and shear stiffness according to the definition adopted for the stiffness. The measured values for the stiffness of the domestic elastomeric bearings were also verified to exhibit large deviation from the formula proposed by KS F 4420. Elastomeric bearings that does not have appropriate compressive stiffness required at the design can result in uneven deflection at supports of bridges and excessive stress in girders. Accordingly, the establishment of compressive elastic modulus formula and performance evaluation criteria fitted to the domestic circumstances through the execution of performance evaluation of bearings presenting diversified shapes and shape factors appears to be necessary for the domestic bearings to meet the performance required in design.

Conservation Status, Construction Type and Stability Considerations for Fortress Wall in Hongjuupseong (Town Wall) of Hongseong, Korea (홍성 홍주읍성 성벽의 보존상태 및 축성유형과 안정성 고찰)

  • Park, Junhyoung;Lee, Chanhee
    • Korean Journal of Heritage: History & Science
    • /
    • v.51 no.3
    • /
    • pp.4-31
    • /
    • 2018
  • It is difficult to ascertain exactly when the Hongjuupseong (Town Wall) was first constructed, due to it had undergone several times of repair and maintenance works since it was piled up newly in 1415, when the first year of the reign of King Munjong (the 5th King of the Joseon Dynasty). Parts of its walls were demolished during the Japanese occupation, leaving the wall as it is today. Hongseong region is also susceptible to historical earthquakes for geological reasons. There have been records of earthquakes, such as the ones in 1978 and 1979 having magnitudes of 5.0 and 4.0, respectively, which left part of the walls collapsed. Again, in 2010, heavy rainfall destroyed another part of the wall. The fortress walls of the Hongjuupseong comprise various rocks, types of facing, building methods, and filling materials, according to sections. Moreover, the remaining wall parts were reused in repair works, and characteristics of each period are reflected vertically in the wall. Therefore, based on the vertical distribution of the walls, the Hongjuupseong was divided into type I, type II, and type III, according to building types. The walls consist mainly of coarse-grained granites, but, clearly different types of rocks were used for varying types of walls. The bottom of the wall shows a mixed variety of rocks and natural and split stones, whereas the center is made up mostly of coarse-grained granites. For repairs, pink feldspar granites was used, but it was different from the rock variety utilized for Suguji and Joyangmun Gate. Deterioration types to the wall can be categorized into bulging, protrusion of stones, missing stones at the basement, separation of framework, fissure and fragmentation, basement instability, and structural deformation. Manually and light-wave measurements were used to check the amount and direction of behavior of the fortress walls. A manual measurement revealed the sections that were undergoing structural deformation. Compared with the result of the light-wave measurement, the two monitoring methods proved correlational. As a result, the two measuring methods can be used complementarily for the long-term conservation and management of the wall. Additionally, the measurement system must be maintained, managed, and improved for the stability of the Hongjuupseong. The measurement of Nammunji indicated continuing changes in behavior due to collapse and rainfall. It can be greatly presumed that accumulated changes over the long period reached the threshold due to concentrated rainfall and subsequent behavioral irregularities, leading to the walls' collapse. Based on the findings, suggestions of the six grades of management from 0 to 5 have been made, to manage the Hongjuupseong more effectively. The applied suggested grade system of 501.9 m (61.10%) was assessed to grade 1, 29.5 m (3.77%) to grade 2, 10.4 m (1.33%) to grade 3, 241.2 m (30.80%) and grade 4. The sections with grade 4 concentrated around the west of Honghwamun Gate and the east of the battlement, which must be monitored regularly in preparation for a potential emergency. The six-staged management grade system is cyclical, where after performing repair and maintenance works through a comprehensive stability review, the section returned to grade 0. It is necessary to monitor thoroughly and evaluate grades on a regular basis.

Measurement of Bone mineral density According to Middle aged Women with Low Back Pain (중년여성의 요통에 따른 골밀도 측정)

  • Kang, Jeom-Deok;Kim, Jong-Bong
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.7 no.1
    • /
    • pp.5-28
    • /
    • 2001
  • Objectives: The objective of this study was to investigate analysis of bone mineral density according to Women with low back pain women. Methods: The data were collected from women who visited Physical Examination Center of a Catholic university hospital located in Daegu. Questionnaires were completed by 50 women during the period from July 20, 2000 to January 12, 2001. The sample was divided into three groups(the normal group of 16 cases and the osteopenia group of 12cases and the osteoporosis group of 22 cases). Bone mineral density(BMD) of lumbar spine was measured using energy absorptiometry. Results: The bone mineral density of the lumbar spine decreased with aging. The bone mineral density of the lumbar spine decreased with the serum Calcium and Phosphorus and Alkaline phosphatase increased. The mean bone mineral density of the lumbar spine of healthy women in age(50~59) was 0.87g/$cm^2$, the lumbar spine of women with low back pain in age(50~59) was 0.77g/$cm^2$. In the multiple regression of risk factors to bone mineral density(BMD) of lumbar spine were correlated with age, marriage existence, exercise time, the loving food of taste, calcium, bone mineral density standard T scores(p<0.05). The experience for LBP increased as weight increased(Odds ratio=999.000). The experience for LBP increased as number of Exercise decreased(Odds ratio=999.000). The experience for LBP increased as menopause existence increased(Odds ratio=999.000). The experience for LBP increased as serum Calcium and Phosphorus increased (Odds ratio=999.000). however all four variables had significant no relationship. The correlation in variables in relation to low back pain and bone mineral density, age showed contra-correlation with low back pain existence, Alkaline phosphatase(p<0.01). Weight showed contra-correlation with body mass index(BMI)(p<0.01). Exercise time showed correlation with number of exercise(p<0.01). The loving food of taste showed contra-correlation with Alkaline phosphatase(p<0.05). Bone mineral density showed correlation with menopause existence(p<0.05). Conclusions: Results from this study indicated that a statistically significant association between bone mineral density of the lumbar spin and age, marriage existence, exercise time, the loving food of taste, calcium, bone mineral density standard T scores. In logistic regression test, there were no related variables. The combination of bone mineral density measurement and assessment of the bone turnover rate by measuring biochemical would be helpful for the treatment of patients with risks of osteoporosis. The more precise study for risk factors to osteoporosis is essential.

  • PDF

A Study for the development of the Korean orthodontic bracket (한국형 교정치료용 Bracket의 개발에 관한 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Moon, Seong-cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.565-578
    • /
    • 2000
  • The aim of this study was development of the Straight-Wire Appliance(SWA) suitable lot the treatment or Korean. To accomplish the object of this study, Korean adult with normal occlusion were selected with following criteria : 1) no functional abnormality in the craniofacial area, 2) good dental arch form and posterior occlusal relationship, 3) Angle Class I occlusal relationship, 4) no experience of orthodontic, nor prosthodontic treatment, especially, no dental treatment on labial and buccal surfaces of teeth, 5) good racial profile. Impression were taken for upper and lower dental arches or the selected normal occlusion samples and the orthodontic dental stone models were fabricated. 5 well-trained orthodontists had examined the acquired dental stone models to select study samples which satisfy the Six keys to optimal occlusion of Andrews. 155 pairs of dental stone models (92 pairs of Male, 63 of Female) were finally selected. 3 dimensional digitization were performed with the Coordinate Measuring Machine(CMM, MPC802, WEGU-Messtechnik, Germany) and measuring of Angulation, Inclination, In-and-Out, Molar offset angle and Arch form were accomplished with a measuring software to achieve data for the development of SWA. Before the measurement, error study was performed on the 3 dimensional digitization with CMM, and the analysis of reliability of computerized measuring method adapted in this study and conventional manual method Presented by Andrews was performed. Results of this study were as to)lows : 1. Equi-distance digitization with mesh size 0.25 mm, 0.5 mm and 1.0 mm were acceptable in 3 dimensional digitization of dental stone model with the CMM, and the digitization with 1.0 mm mesh size was recommendable in terms of efficiency. 2. Computerized measuring method with 3 dimensional digitization was more reliable than manual measuring method of Andrews. 3. Data were collected for the development of SWA suitable for the morphological characteristics of Korean with the computerized measuring method with 3 dimensional digitization.

  • PDF

Upper Body Surface Change Analysis using 3-D Body Scanner (3차원 인체 측정기를 이용한 체표변화 분석)

  • Lee Jeongran;Ashdoon Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.29 no.12 s.148
    • /
    • pp.1595-1607
    • /
    • 2005
  • Three-dimensional(3-D) body scanners used to capture anthropometric measurements are now becoming a common research tool far apparel. This study had two goals, to test the accuracy and reliability of 3-D measurements of dynamic postures, and !o analyze the change in upper body surface measurements between the standard anthropometric position and various dynamic positions. A comparison of body surface measurements using two different measuring methods, 3-D scan measurements using virtual tools on the computer screen and traditional manual measurements for a standard anthropometric posture and for a posture with shoulder flexion were $-2\~20mm$. Girth items showed some disagreement of values between the two methods. None of the measurements were significantly different except f3r the neckbase girth for any of the measuring methods or postures. Scan measurements of the upper body items showed significant linear surface change in the dynamic postures. Shoulder length, interscye front and back, and biacromion length were the items most affected in the dynamic postures. Changes of linear body surface were very similar for the two measuring methods within the same posture. The repeatability of data taken from the 3-D scans using virtual tools showed satisfactory results. Three times repeated scan measurements f3r the scapula protraction and scapula elevation posture were proven to be statistically the same for all measurement items. Measurements from automatic measuring software that measured the 3-D scan with no manual intervention were compared with the measurements using virtual tools. Many measurements from the automatic program were larger and showed quite different values.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

Principles and Applications of Multi-Level H2O/CO2 Profile Measurement System (다중 수증기/이산화탄소 프로파일 관측 시스템의 원리와 활용)

  • Yoo, Jae-Ill;Lee, Dong-Ho;Hong, Jin-Kyu;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.1
    • /
    • pp.27-38
    • /
    • 2009
  • The multi-level profile system is designed to measure the vertical profile of $H_2O$ and $CO_2$ concentrations in the surface layer to estimate the storage effects within the plant canopy. It is suitable for long-term experiments and can be used also in advection studies for estimating the spatial variability and vertical gradients in concentration. It enables the user to calculate vertical fluxes of water vapor, $CO_2$ and other trace gases using the surface layer similarity theory and to infer their sources or sinks. The profile system described in this report includes the following components: sampling system, calibration and flow control system, closed path infrared gas analyzer(IRGA), vacuum pump and a datalogger. The sampling system draws air from 8 inlets into the IRGA in a sequence, so that for 80 seconds air from all levels is measured. The calibration system, controlled by the datalogger, compensates for any deviations in the calibration of the IRGA by using gas sources with known concentrations. The datalogger switches the corresponding valves, measures the linearized voltages from the IRGA, calculates the concentrations for each monitoring level, performs statistical analysis and stores the final data. All critical components are mounted in an environmental enclosure and can operate with little maintenance over long periods of time. This report, as a practical manual, is designed to provide helpful information for those who are interested in using profile system to measure evapotranspiration and net ecosystem exchanges in complex terrain.

A Study of Analgesic Effect of Twirling Acupuncture on Pain Model of the Formalin Test Using the Infrared Thermal Image Processing (적외선 영상 처리를 통한 Formalin Test 통증 모델에서의 염전 침자극 효과에 대한 연구)

  • Ryu, Jae-kwan;Lee, Soon-geul;Rhim, Sung-soo;Lee, Jae-dong;Min, Byung-il;Ryu, Un-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.2
    • /
    • pp.223-233
    • /
    • 2004
  • Objective: As a manual accupucture method, the twirling-needle treatment has been known more effective in relieving pain than the conventional simple accupuncture treatment. Finding a proper treatment condition is difficult because of the lack of a quantative measurement of the alleviation of pain made by acupuncture. In this research, the authors propose the use of infrared thermal images in a formalin test to quantatively verify the effect of twirling. Methods: After injecting 10%~20% formalin into the tail of rats, the infrared thermal images(ITI) have been obtained to estimate the thermal distribution caused by inflammation. The authors propose a processing method to measure the thermal distribution from the thermal images obtained from the infrared camera as a pain model of the formalin test. Results: The pain model obtained from the infrared thermal image has two phases. The first phase, which is a transient period, is the initial 20 minutes when the pain is developed after the formalin injection. The second phase, which is a steady state, is where the development of pain lasts for 60 minutes or more after the first stage. This characteristic of the proposed model based on ITI is consistent with that of the pain model reported by other researchers whose works are based on the time-course of flinching and licking/biting, following a different concentration of formalin. It is noticed that the response of the thermal distribution obtained from ITI shows very high correlation to the behavioral response in the formalin test performed by Kazuhiro Okuda and four others5). In addition, the authors propose an ITI method to determine the pain-reducing effect of the acupuncture. The thermal distribution obtained from the experiment shows that there is significant pain reducing effect made by the twirling-needle method.

  • PDF

A Study on the Usefulness of an Examination Information Printout during Ordinary X-Ray Examinations (일반촬영 검사 시 검사안내 유인물의 유용성에 관한 고찰)

  • Kang, Sang-Oh;Hong, Seong-Kwon;Son, Seok-Ho;Lee, Min-Woo;Kim, Kyeong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • In a normal x-ray examination, the cooperation of a patient in positioning greatly influences the improvement of work performance, the quality of the images and the reduction in time spent on the examination. An attempt was made to discover the connection between an examination information printout and the effects of the examination by informing the patient before the examination on the examination positions in order to increase the level of cooperation by the patient and by surveying the degree of satisfaction of the patient during the examination proceedings. An examination information printout was prepared on five positions that patients consider to be difficult while receiving normal x-ray examinations and were shown to 257 male and female patients between the ages of 30 to 79 who had visited this hospital between January 1 to February 29, 2012 or to a person who had accompanied the patients before the examination to research the degree of satisfaction regarding the printout. In addition, the examination explanation printout was given to Radiologic Technologists with over 1 year experience in this hospital to use while taking the x-rays and the degree of satisfaction was surveyed and it was examined if the increase of the degree of satisfaction had an effect on the reduction in the examination time. The patients who utilized the examination information printout revealed results of approximately a 7.8% higher degree of satisfaction among the patients who had previous experience receiving x-ray examinations compared to those were having an x-ray for the first time. In the age groups between 30 to 70 years of age, the age group in the 30's revealed the lowest level of satisfaction at approximately 69% and the group in the 50's showed the highest degree of satisfaction of 87.94%. In the survey of the Radiologic Technologists, 85% responded that they were satisfied. In the question that stated "Will the examination information printouts reduce the time involved in unnecessary conversations with the patients?," the responses showed a 95% degree of satisfaction. The degree of satisfaction was high over the examination information printout by both the patients and the Radiologic Technologists. Although the effects of examination time reduction varied based on the ages of the patients and physical conditions that they were in and could not be given measurement values, it was able to be seen through the survey that reduction of the unnecessary communication between the patient and the Radiologic Technologists contributed to the increase in the degree of satisfaction. As a result, both the patients and the Radiologic Technologists had an increased degree of satisfaction over the examination information printout and it was possible for improvements to be made in the quality of medical service provided as well. Nevertheless, it is considered that a more developed manual in terms of quality and quantity must be produced using a more systematic approach and design.

  • PDF