• Title/Summary/Keyword: Mandibular positions

Search Result 116, Processing Time 0.023 seconds

The Effect of Head Posture Change on Initial Occlusal Contacts (두부의 자세 변화가 초기 교합접촉에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.195-204
    • /
    • 1995
  • The purpose of this study was to evaluate effect of head posture change on initial occlusal contacts through measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture. Two special devices were designed and constructed. Mandibular movement replicator was used to assess reliability of the K6 diagnostic system(MKG; Myo-tronic Inc, Seatle, USA) and head posture calibrator was used to maintain the constant head posture during experiment. We measured difference of distance between initial occlusal contact and maximum intercuspal position with MKG in upright, supine, 45 degrees extension, 30 degrees flexion, 30 degrees right and left bending postion of the head. The Frankfurt horizontal plane was used as a reference plane. 21 adults aged from 23 to 25 were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. The obtained results were as follows : The mean absolute distances between initial occlusal contact and maximum intercuspal postion were 0.39(0.18mm in the upright position, 0.65(0.37mm in the supine position, 0.59(0.33mm in the 45 degree extension, 0.70(0.53mm in the 30 degrees flexion, 1.12(1.10mm in the 30 degrees right bending and 1.94(0.67mm in the 30 degrees left bending of the head. The positions of the initial occlusal contacts have a tendency to locate anterior, left and inferior to maximal intercuspal position in upright position, posterior and inferior in supine position and 45 degrees extension, anterior and inferior in 30 degrees flexion, right and inferior in 30 degrees right bending, and left and inferior in 30 degrees left bending of the head. There were significant differences among the initial occlusal contacts in each head postures(P<0.0001). Therefore, we need to check initial occlusal contacts in the altered head posture during occlusal analysis and adjustment of occlusal appliance and dental occlusion for diagnosis and treatment of temporomandibular disorder.

  • PDF

THE EFFECT OF CLASP DESIGN ON ABUTMENT TOOTH MOVEMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURE (유리단 국소의치의 Clasp설계가 지대치 운동에 미치는 영향)

  • Yim, Soon-Ho;Chang, Ik-Tai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.17-40
    • /
    • 1987
  • The purpose of this study was to clarify the effect of clasp design on abutment tooth adjacent to a distal extension base under the influence by the location of functional loading. The RPI clasp, the Akers clasp and the combination clasp were selected for evaluation. Tests were performed at 10Kg, 20Kg, 30Kg loads on the buccal, central, lingual, mesial and distal positions of loading platform of each mandibular distal extension partial denture. The laser reflexion method was used for three dimensional measurement of abutment movement, which is possible to measure precisely without contact. The movement in the mesiodistal(X), buccolingual(Y), and occlusoapical(Z) directions and the rotational movement(R) were measured, and in addition, the total movement (SV) as expressed by the three dimensional summation vector independent of direction was calculated. The data were analyzed using Student t-test, p<.05. The following results were obtained from this study; 1. Clasp design did not generally affect the direction of abutment tooth movement except the movement in an undesirable occlusal direction in case of the Akers clasp and the combination clasp. 2. The greater the load on the prosthesis, the greater was the abutment tooth movement, and the direction of abutment tooth movement was affected by positional loading. 3. Each prosthesis was dislodged from the test base under the small amount of load in the distal load position, and the buccal loading showed the greatest abutment tooth movement under the maximum load. 4. RPI clasp was evaluated as the most favorable design.

  • PDF

A STUDY OF OCCLUSAL CONTACT VARIATON DUE TO CHANGE IN EACH HEAD POSITION IN NORMAL OCCLUSION (정상교합인의 두부위치변화에 따른 교합접촉점의 변화에 관한 연구)

  • Choi, Hee-Cheol;Lee, Sung-Bok;Choi, Dae-Gyun;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.769-779
    • /
    • 1995
  • The understanding the nature of occlusal tooth contacts of natural dentition is important for correct diagnosis and treatment of diseases developed in stomatognatic system. Several investigator have studied the distribution of tooth contacts in maximum intercuspation and have repored contact locations with respect to the tooth position. However, there are few report the variation of the occlusal contact point with change in each head position. This study analysed the number of occlusal contact point with change in each head position. 30 subject(male 17, female 13), who ahad natural occlusion and no symptoms of temporomandibular disorder, were selected. The numbers and patterns of tooth contact were recorded by silicone bite registration on stone model at four different head positions with head anguration gauge(from the supine to the upright position). The results obtained were as follows : 1. The numbers of total occlusal contact point on teeth increased to average 25, 29, 35, 42 points as head angulation was changed from the supine to the upright position against the ala-tragus line, and there was significant difference(P<0.05). 2. In the 19 subject(65%)of total 30 subject, the perforated point of the silicone bite indicated that the locus for the prime contact point moved mesially as the head angulation was changed from the supine to the upright position. 3. On the basis of the fact that the anterior occlusal contact point increase as head angulation changed from the supine to the upright position, we could find that the mandibular position is moved anteriorly.

  • PDF

Magnetic resonance imaging-based temporomandibular joint space evaluation in tempormandibular disorders (측두하악관절증에서 자기공명영상을 이용한 측두하악관절의 관절강 평가)

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.15-18
    • /
    • 2007
  • Purpose : Disc and condylar position were observed on MRIs of temporomandibular joint disorder patients and condylar position agreement between MRI and tranascranal radiography was evaluated. Materials and Methods MRI and transcranial radiographs of both TM joints from 67 patients with temporemandibular disorder were used. On MRI, the position and shape of disc and condylar position as anterior, middle, posterior was evaluated at medial, center, and lateral views. On transcranial radiographs, condylar position was evaluated using the shortest distance from condyle to fossa in anterior, superior, and posterior directions. Results. 1. On MRI, 96 joints (71.6%) of 134 had anterior disc dispalcement with reduction and 38 joints (28.4%) without reduction. 2. Fourteen (14.6%) of 96 reducible joints showed anterior condylar position, 19 (19.8%) showed central position, 63 joints (65.6%) showed posterior position. Two joints (5.3%) of 38 non-reducible joints showed anterior condylar position, while 9 (23.7%) showed central position, and 27 (71.1%)-posterior position. 3. In 85 joints (63.4%) of 134, the transcranial condylar position agreed with that of the central MRI view, 10 joints (7.5%) with that of medial, 16 joints (11.9%) with that of lateral, and 23 joints (17.2%) disagreed with that of MRI. Conclusion : On MRT, most oi the reducible and non-reducible joints showed posterior condylar position. Transcranial radiographs taken with machine designed for TMJ had better agreement of condylar position with that of MRI. Extremely narrow joint spaces or very posterior condylar positions observed on transcranial radiographs had a little more than fifty percent agreement with those of MRIs.

  • PDF

Evaluation of condylar positions in patients with temporomandibular disorders: A cone-beam computed tomographic study

  • Imanimoghaddam, Mahrokh;Madani, Azam Sadat;Mahdavi, Pirooze;Bagherpour, Ali;Darijani, Mansoreh;Ebrahimnejad, Hamed
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.127-131
    • /
    • 2016
  • Purpose: This study was performed to compare the condylar position in patients with temporomandibular joint disorders (TMDs) and a normal group by using cone-beam computed tomography (CBCT). Materials and Methods: In the TMD group, 25 patients (5 men and 20 women) were randomly selected among the ones suffering from TMD according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD). The control group consisted of 25 patients (8 men and 17 women) with normal temporomandibular joints (TMJs) who were referred to the radiology department in order to undergo CBCT scanning for implant treatment in the posterior maxilla. Linear measurements from the superior, anterior, and posterior joint spaces between the condyle and glenoid fossa were made through defined landmarks in the sagittal view. The inclination of articular eminence was also determined. Results: The mean anterior joint space was 2.3 mm in the normal group and 2.8 mm in the TMD group, respectively. The results showed that there was a significant correlation between the superior and posterior joint spaces in both the normal and TMD groups, but it was only in the TMD group that the correlation coefficient among the dimensions of anterior and superior spaces was significant. There was a significant correlation between the inclination of articular eminence and the size of the superior and posterior spaces in the normal group. Conclusion: The average dimension of the anterior joint space was different between the two groups. CBCT could be considered a useful diagnostic imaging modality for TMD patients.

An experimental study on the reproducibility and the position of centric relation and Myocentric (중심위와 Myocentric의 재현성 및 상호위치에 관한 연구)

  • Lee, Jong-Yeab;Kim, Kwang-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.24 no.1
    • /
    • pp.45-54
    • /
    • 1986
  • The establishment and/or registration of an optimal or physiologic relationship between the maxillae and mandible has long been a subject of considerable interest and controversy in dentistry. Centric relation has been generally accepted as a repeatable starting point for restoring the mouth. Recently, it has been claimed that an electronic device (Myo-Monitor) will produce an accurate, reproducible occlusal registration at the vertical and horizontal occlusal position most compatible with the muscular of each patient. The objectives of this study was to compare Myo-Monitor centric to centric relation at the points of reproducibility and anteroposterior, superoinferior position. A Vericheck instrument was employed for examining difference in the position and reproducibility of mandible reproduced by the various check bite records. For this study, 8 dental students and dentists who had no missing teeth and no difficulties of mandibular movement were selected. The following three different positions of the mandible were registered (a) centric relation manipulated by means of chin-point technique with Lucia-jig, (b) centric relation manipulated by means of bilateral technique, (c) Myocentric manipulated by Myo-Monitor. From this experiment, the following results were obtained. 1. Bilateral manipulated centric relation was more reproducible than Myocentric in anteroposterior and superoinferior position , but more reproducible than centric relation manipulated by means of chin point technique with Lucia-jig in anteroposoterior position. Centric relation manipulated by means of chin Point technique with Lucia-jig was more reproducible than Myocentric in right anteroposterior and superoinferior position. 2. Centric relation by means of chin point technique with Lucia-jig was posterior($2.16{\pm}0.78mm$) and superior($0.41{\pm}0.16mm$) to centric occlusion. Bilateral manipulated centric relation was posterior($1.68{\pm}0.10mm$) and superior($1.02{\pm}0.45mm$) to centric occlusion. Myocentric was anterior($0.75{\pm}0.70mm$), inferior($0.59{\pm}0.44mm$) to centric occlusion.

  • PDF

A CASE REPORT OF THE FACIAL ASYMMETRY BY INFANTILE MAXILLOFACIAL SURGERY (유아기 악골 수술로 인해 유발된 안면 비대칭 환자에서의 BSSRO를 이용한 안모 교정의 치험례)

  • Choi, So-Young;Kim, Jin-Wook;Kwon, Tae-Geon;Lee, Sang-Han;Park, In-Suk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.584-588
    • /
    • 2008
  • Facial asymmetry is particularly associated with mandible among other facial bones and it could be either congenital or acquired. Congenital factors are related to Treacher Collin syndrome, Pierre Robin syndrome, hemifacial microsomia and other various syndromes. Acquired factors are such as damaged or diseased growing condyles, hormonal disorder, oral mal-habit, muscular force, tumor, infection and so on. Diagnosis and treatment of facial asymmetry are complicated due to differences in sizes and positions of mandibles. The aspects of facial asymmetry is various and complicated upon each individual. Depending on causes of the facial asymmetry, there also are morphological differences. For such reasons, precise anatomical analysis and diagnosis of the facial asymmetry are essential before any surgical procedure followed by the appropriate treatment plan. This case is regarding a 21-year old patient diagnosed as the facial asymmetry due to an infantile maxillofacial surgery. Employing various morphological evaluations, potential problems during the procedure are predicted beforehand. This case reports a favorable result of sagittal split ramus osteotomy performing the oblique vertical bone cutting in posterior-superior of the mandibular second molar.

Rehabilitation of mandibular edentulous patients with a few unilateral remaining teeth using implant-assisted removable partial denture: A case report (하악 편측 소수 잔존치 환자의 임플란트 보조 국소의치를 이용한 보철치료 증례)

  • Lee, Bhumgey David;Lee, Yong-Sang
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.42-48
    • /
    • 2019
  • In the case of a patient with a small number of unilateral remaining teeth in the mandible, a restoration with conventional removable partial denture cannot provide sufficient retention and resistance. A harmful stress from the poor stability of denture on remaining teeth occurs due to alveolar bone resorption in edentulous area. Although implant fixed prosthesis can provide multiple benefits over conventional removable partial denture, there are limitations come from anatomic structures and costs. In this case, an implant-assisted removable partial denture (IARPD) with a couple of implants placed in strategic positions can be a treatment modality. The objective of this article is to present a case report of two patients showed satisfactory clinical outcomes during three-year follow-up period describing the fabrication and advantages of removable partial denture assisted by teeth and implants (IARPD) for a patient with a small number of unilateral remaining teeth in mandible using Locator as an implant attachment.

Effects of a modified surgical protocol on the positional accuracy of dental implants placed using fully guided implant surgery in the partially edentulous posterior ridge with distal extension: a dentiform model study

  • Young Woo Song;Seung Ha Yoo;Ui-Won Jung
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2024
  • PURPOSE. The present experiment aimed to evaluate the placement accuracy of fully guided implant surgery using a mucosa-supported surgical guide when the protocol of osteotomy and installation was modified (MP) compared to when the protocol was sequentially and conventionally carried out (CP). MATERIALS AND METHODS. For 24 mandibular dentiform models, 12 dentists (6 experts and 6 beginners) performed fully guided implant placements two times at the right first and second molar sites using a mucosa-supported surgical guide, once by the CP (CP group) and at the other time by the MP (MP group). The presurgical and postsurgical stereolithographic images were superimposed, and the deviations between the virtually planned and actually placed implant positions and the procedure time were compared statistically (P < .05). RESULTS. The accuracies were similar in the CP and MP groups. In the CP group, the mean platform and apex deviations at the second molar site for the beginners were +0.75 mm and +1.14 mm, respectively, which were significantly larger than those for the experts (P < .05). In the MP group, only the mean vertical deviation at the second molar site for the beginners (+0.53 mm) was significantly larger than that for the experts (P < .05). The procedure time was significantly longer for the MP group (+94.0 sec) than for the CP group (P < .05). CONCLUSION. In fully guided implant surgery using a mucosa-supported guide, the MP may improve the placement accuracy when compared to the CP, especially at sites farther from the most-posterior natural tooth.

MICROTENSILE BOND STRENGTH ACCORDING TO DIFFERENT DENTIN WALL POSITIONS AND CURING LIGHTS IN CLASS I CAVITY OF PRIMARY MOLAR (유구치 I급 와동에서 와동벽 위치와 중합광원에 따른 Microtensile Bond Strength 비교 연구)

  • Lee, Hyeon-Heon;Jang, Chul-Ho;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.62-72
    • /
    • 2007
  • The purpose of present study was to determine whether different kinds of curing lights can alter microtensile bond strength(MTBS) of class I cavity pulpal and axial wall specimens in primary molar. Thirty clean mandibular 2nd primary molar's occlusal enamel were removed and class I cavity, size of $2{\times}4{\times}2mm$ was prepared. Dentin bonding agent was applied according to manufacturer's manual. Each group was cured with Halogen Curing Unit, Plasma Curing Unit and LED Curing Unit. Composite resin was bulk filled and photo cured with same curing unit. MTBS specimens which size is $0.7{\times}0.7{\times}4mm$ were prepared with low speed saw. Specimens were coded by their curing lights and wall positions (Halogen - Axial wall group, Halogen - Pulpal wall group, Plasma - Axial wall group, Plasma - Pulpal wall group, LED - Axial wall group, LED - Pulpal walt group). MTBS were tested at 1 mm/min cross Head speed by Universal Testing Machine. Fractured surface and bonding surface was observed with SEM. T-test between axial and pulpal specimens in each curing lights, one-way ANOVA among different curing light specimens in each wall positions were done. Weibull distribution analysis was done. The results were as follows : Mean MTBS of pulpal wall specimens were significantly greater than that of axial wall specimens at each curing units(p<.05). There was no significant difference in the MTBS among three curing units at axial wall and pulpal wall. In Weibull distribution, pulpal wall specimens were more homogeneous than axial wall specimens.

  • PDF