• Title/Summary/Keyword: Maintenance energy

검색결과 1,399건 처리시간 0.031초

태양광 발전설비의 유지관리에 따른 발전량 변화 분석 (Variation Analysis of Power Generation according to Maintenance of Photovoltaic Equipment)

  • 박병훈;최종원;김재엽
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 추계 학술논문 발표대회
    • /
    • pp.79-80
    • /
    • 2015
  • With the government's support for new and renewable energy, photovoltaic equipment has rapidly been supplied. However, compared to supply rate, maintenance has not supported enough and relevant research has not much conducted. Therefore, the purpose of this study is to analyze maintenance effectiveness of photovoltaic equipment. What is the most important in maintenance effectiveness is a rise in power generation. It was estimated that if photovoltaic equipment for detached houses is maintained well, power generation increases by 4.0% at least, and by 6.5% on average. As a result, it was analyzed that it is necessary to maximize the effectiveness of the government's budget investment through well maintenance of photovoltaic equipment for detached houses.

  • PDF

Development of a Vision-based Position Estimation System for the Inspection and Maintenance Manipulator of Steam Generator Tubes a in Nuclear Power Plant

  • Jeong, Kyung-Min;Cho, Jae-Wan;Kim, Seung-Ho;Kim, Seung-Ho;Jung, Seung-Ho;Shin, Ho-Chul;Choi, Chang-Whan;Seo, Yong-Chil
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.772-777
    • /
    • 2003
  • A vision-based tool position estimation system for the inspection and maintenance manipulator working inside the steam generator bowl of nuclear power plants can help human operators ensure that the inspection probe or plug are inserted to the targeted tube. Some previous research proposed a simplified tube position verification system that counts the tubes passed through during the motion and displays only the position of the tool. In this paper, by using a general camera calibration approach, tool orientation is also estimated. In order to reduce the computation time and avoid the parameter bias problem in an ellipse fitting, a small number of edge points are collected around the large section of the ellipse boundary. Experiment results show that the camera calibration parameters, detected ellipses, and estimated tool position are appropriate.

  • PDF

태양열 온수기 실증연구를 통한 성능 평가 (Performance Evaluation of Solar Water Heating System Using Proof Test)

  • 김재열;곽이구;양동조;최철준;김홍건
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

토크백 시스템 무선통신 적용방안 연구 (A study on the application of TALK-BACK system in a radio communication environment)

  • 여용주;윤인영;남정인;최윤석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1294-1302
    • /
    • 2008
  • Talk-Back systems comprised of master-equipment at the control room and slave-equipment at turnouts refer to the intercommunication facilities that optimize mutual communication between maintenance staff on trackside and the control room to facilitate quickness and accuracy of train operation control and its maintenance within depot and on mainlines with turnouts for direction switching of the trains in operation. The weakness lies in additional maintenance costs of cables since the Talk-Back system installed on line 1 along with line 2-4 has a profound effect on the voice quality leading to the attenuation and crosstalk of the system due to the deterioration of cables and environmental factors. This paper discusses the Talk-Back system in a radio communication environment with the application of RF(Radio Frequency) communication system from the wire communication system by cables to ameliorate these problems, and deals with the energy saving environmentally friendly facilities in consideration of replacing power section at salve-equipment with solar batteries benefitting the system in light of energy consumption.

  • PDF

Daily Feed Intake, Energy Intake, Growth Rate and Measures of Dietary Energy Efficiency of Pigs from Four Sire Lines Fed Diets with High or Low Metabolizable and Net Energy Concentrations

  • Schinckel, A.P.;Einstein, M.E.;Jungst, S.;Matthews, J.O.;Booher, C.;Dreadin, T.;Fralick, C.;Wilson, E.;Boyd, R.D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제25권3호
    • /
    • pp.410-420
    • /
    • 2012
  • A trial was conducted to: i) evaluate the BW growth, energy intakes and energetic efficiency of pigs fed high and low density diets from 27 to 141 kg BW, ii) evaluate sire line and sex differences when fed both diets, and iii) to compare ME to NE as predictor of pig performance. The experiment had a replicated factorial arrangement of treatments including four sire lines, two sexes (2,192 barrows and 2,280 gilts), two dietary energy densities and a light or heavy target BW, 118 and 131.5 kg in replicates 1 to 6 and 127 and 140.6 kg in replicates 7 to 10. Pigs were allocated to a series of low energy (LE, 3.27 Mcal ME/kg) corn-soybean meal based diets with 16% wheat midds or high energy diets (HE, 3.53 to 3.55 Mcal ME/kg) with 4.5 to 4.95% choice white grease. All diets contained 6% DDGS. The HE and LE diets of each of the four phases were formulated to have equal lysine:Mcal ME ratios. Pigs were weighed and pen feed intake (11 or 12 pigs/pen) recorded at 28-d intervals. The barrow and gilt daily feed (DFI), ME (MEI) and NE (NEI) intake data were fitted to a Bridges function of BW. The BW data of each sex were fitted to a generalized Michaelis-Menten function of days of age. ME and NE required for maintenance (Mcal/d) were predicted using functions of BW (0.255 and 0.179 BW^0.60 respectively). Pigs fed LE diets had decreased ADG (915 vs. 945 g/d, p<0.001) than pigs fed HE diets. Overall, DFI was greater (p<0.001) for pigs fed the LE diets (2.62 vs. 2.45 kg/d). However, no diet differences were observed for MEI (8.76 vs. 8.78 Mcal/d, p = 0.49) or NEI (6.39 vs. 6.44 Mcal/d, p = 0.13), thereby indicating that the pigs compensated for the decreased energy content of the diet. Overall ADG:DFI (0.362 vs. 0.377) and ADG:Mcal MEI (0.109 vs. 0.113) was less (p<0.001) for pigs fed LE compared to HE diets. Pigs fed HE diets had 3.6% greater ADG:Mcal MEI above maintenance and only 1.3% greater ADG:Mcal NEI (0.152 versus 0.150), therefore NEI is a more accurate predictor of growth and G:F than MEI.Pigs fed HE diets had 3.4% greater ADG:Mcal MEI and 0.11% greater ADG:NEI above maintenance than pigs fed LE diets, again demonstrating that NEI is a better predictor of pig performance than MEI. Pigs fed LE diets had similar daily NEI and MEI but grew slower and less efficiently on both ME and NE basis than pigs fed HE diets. The data suggest that the midds NE value (2.132 Mcal/kg) was too high for this source or that maintenance was increased for pigs fed LE diets.

태양광 모듈 출력 보상을 위한 마이크로컨버터 시제품 동작 특성 분석 (Characteristics Analysis of Proto-type Microconverter for Power Output Compensation of Photovoltaic Modules)

  • 김지현;김주희;이정준;박종성;김창헌
    • Current Photovoltaic Research
    • /
    • 제10권4호
    • /
    • pp.133-137
    • /
    • 2022
  • The economic feasibility of a photovoltaic (PV) system is greatly influenced by the initial investment cost for system installation. Also, electricity generation by PV system is highly important. The profits competitiveness of PV system will be maximized through intelligent operation and maintenance (O&M). Here, we developed a microconverter which can maximize electricity generation from PV modules by tracking the maximum power point of PV modules, and help efficient O&M. Also, the microconverter mitigates current mismatch caused by shading, hence maximize power generation. The microconverters were installed PV modules and demonstrated through the field tests. Power outputs such as voltage, string current were measured with variuos weather environments and partial shadings. We found that PV modules with the microconvertors shows 12.05% higher power generation compared to the reference PV modules.

Bluetooth Low-Energy Current Sensor Compensated Using Piecewise Linear Model

  • Shin, Jung-Won
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.283-292
    • /
    • 2020
  • Current sensors that use a Hall element and Hall IC to measure the magnetic fields generated in steel silicon core gaps do not distinguish between direct and alternating currents. Thus, they are primarily used to measure direct current (DC) in industrial equipment. Although such sensors can measure the DC when installed in expensive equipment, ascertaining problems becomes difficult if the equipment is set up in an unexposed space. The control box is only opened during scheduled maintenance or when anomalies occur. Therefore, in this paper, a method is proposed for facilitating the safety management and maintenance of equipment when necessary, instead of waiting for anomalies or scheduled maintenance. A Bluetooth 4.0 low-energy current-sensor system based on near-field communication is used, which compensates for the nonlinearity of the current-sensor output signal using a piecewise linear model. The sensor is controlled using its generic attribute profile. Sensor nodes and cell phones used to check the signals obtained from the sensor at 50-A input currents showed an accuracy of ±1%, exhibiting linearity in all communications within the range of 0 to 50 A, with a stable output voltage for each communication segment.

USN 기술을 이용한 공기압축기 원격관리 시스템 설계 (A Design of Air Compressor Remote Control System Using USN Technology)

  • 황문영
    • 한국인공지능학회지
    • /
    • 제6권1호
    • /
    • pp.1-10
    • /
    • 2018
  • Compressed Air is an important energy source used in most factories nowadays. The automation trend using air compressor has been gradually increasing with the interest of the 4th industry in recent years. With the air compressor system, it is possible to construct the device at low cost and easily achieve automation and energy saving. In addition, With trend of FA, miniaturation and light weight manufacturing trend expand their use in the electronics, medical, and food sectors. Research method is to design the technology for the remote control of the following information as USN base. Development of flexible sensing module from real time observation module for fusion of IT technology in compressed air systems, design and manufacture of flexible sensing module, and realiability assessment. Design of real-time integrated management system for observation data of compressed air system - Ability to process observation data measured in real time into pre-processing and analysis data. This study expects unconventionally decreasing effect of energy cost that takes up 60~70% of air compressor layout and operation and maintenance management cost through USN(Ubiquitous Sensor Network) technology by using optimum operational condition from real time observation module. In addition, by preventing maintenance cost from malfunction of air compressor beforehand, maintenance cost is anticipated to cut back.