Generalized Lymphangiomatosis: A Case Report (전신성 림프관종증: 증례 보고)

  • Cha, Jang-Gyu;Park, Jai-Soung;Paik, Sang-Hyun;Kim, Hee-Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.190-194
    • /
    • 2009
  • Generalized lymphangiomatosis is a rare congenital malformation of the lymphatics. CT and MR scan have been used to evaluate lymphangiomas, which appear as large multicystic fluid-filled masses. CT and MR Imaging findings are often helpful in distinguishing lymphangiomas from various vascular disorders. We report the findings of CT, MRI and bone scan in a patient with generalized cystic lymphangiomatosis. Whole body 3.0-T MR scan using STIR sequence with a larger FOV could detect the additional lesions that were not seen at other imaging modalities. We believe that whole body 3.0 T MR imaging is a good modality to evaluate the extent of the disease and following up the patients with the generalized cystic lymphangiomatosis.

  • PDF

MR Contrast Agents and Molecular Imaging (MR조영제와 분자영상)

  • Moon, Woo-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.2
    • /
    • pp.205-208
    • /
    • 2004
  • The two major classes of magnetic resonance (MR) contrast agents are paramagnetic contrast agents, usually based on chelates of gadolinium generating T1 positive signal enhancement, and super-paramagnetic contrast agents that use mono- or polycrystalline iron oxide to generate strong T2 negative contrast in MR images. These paramagnetic or super-paramagnetic complexes are used to develop new contrast agents that can target the specific molecular marker of the cells or tan be activated to report on the physiological status or metabolic activity of biological systems. In molecular imaging science, MR imaging has emerged as a leading technique because it provides high-resolution three-dimension maps of the living subject. The future of molecular MR imaging is promising as advancements in hardware, contrast agents, and image acquisition methods coalesce to bring high resolution in vivo imaging to the biochemical sciences and to patient care.

Thromboembolic Events after Coil Embolization of Cerebral Aneurysms : Prospective Study with Diffusion-Weighted Magnetic Resonance Imaging Follow-up

  • Chung, Seok-Won;Baik, Seung-Kug;Kim, Yong-Sun;Park, Jae-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.6
    • /
    • pp.275-280
    • /
    • 2008
  • Objective : In order to assess the incidence of thromboembolic events and their clinical presentations, the present study prospectively examined routine brain magnetic resonance images (MRI) taken within 48 hours after a coil embolization of cerebral aneurysms. Methods : From January 2006 to January 2008, 163 cases of coil embolization of cerebral aneurysm were performed along with routine brain MRI, including diffusion-weighted magnetic resonance (DW-MR) imaging, within 48 hours after the embolization of the aneurysm to detect the silent thromboembolic events regardless of any neurological changes. If any neurological changes were observed, an immediate brain MRI follow-up was performed. High-signal-intensity lesions in the DW-MR images were considered as acute thromboembolic events and the number and locations of the lesions were also recorded. Results : Among the 163 coil embolization cases, 98(60.1%) showed high-signal intensities in the DW-MR imaging follow-up, 66 cases (67.0%) involved the eloquent area and only 6cases (6.0%) showed focal neurological symptoms correlated to the DW-MR findings. The incidence of DW-MR lesions was higher in older patients (${\geq}60$ yrs) when compared to younger patients (<60 yrs) (p=0.002, odd's ratio=1.043). The older patients also showed a higher incidence of abnormal DW-MR signals in aneurysm-unrelated lesions (p=0.0003, odd's ratio=5.078). Conclusion : The incidence of symptomatic thromboembolic attacks after coil embolization of the cerebral aneurysm was found to be lower than that reported in previous studies. While DW-MR imaging revealed a higher number of thromboembolic events, most of these were clinically silent and transient and showed favorable clinical outcomes. However, the incidence of DW-MR abnormalities was higher in older patients, along with unpredictable thromboembolic events on DW-MR images. Thus, in order to provide adequate and timely treatment and to minimize neurological sequelae, a routine DW-MR follow-up after coil embolization of cerebral aneurysms might be helpful, especially in older patients.

Hyperpolarization: Sensitivity Boost in Magnetic Resonance Spectroscopy and Imaging

  • Ko, Hyeji;Gong, Gyeonghyeon;Jeong, Gijin;Choi, Ikjang;Seo, Hyeonglim;Lee, Youngbok
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Hyperpolarization methods are the most emerging techniques in the field of magnetic resonance (MR) researches since they make a contribution to overcoming sensitivity limitation of MR spectroscopy and imaging, leading to new fields of researches, real-time in vivo metabolic/molecular imaging and MR analysis of chemical/biological reactions in non-equilibrium conditions. Make use of enormous signal enrichments, it becomes feasible to investigate various chemical and biochemical systems with low ${\gamma}$ nuclei in real-time. This review deals with the theoretical principals of common hyperpolarization methods and their experimental features. In addition, more detailed theories, mechanisms, and applications of dissolution dynamic nuclear polarization (D-DNP) are discussed.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

MR Spectroscopy and Diffusion Weighted Imaging Findings of Primary Non-Hodgkin Lymphoma of the Breast: Two Case Reports (유방에 발생한 일차성 비호지킨림프종의 자기공명 분광법 및 확산강조 영상: 2예)

  • Nam, Sang Yu;Yoo, Eun Young;Choi, Hye-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.176-181
    • /
    • 2014
  • Primary non-Hodgkin lymphoma (NHL) of the breast is a very rare disease, and the mammographic and ultrasonographic findings of breast lymphoma are variable. There are several reports of magnetic resonance (MR) imaging findings in patients with breast lymphomas; however, few reports have described the findings observed on MR spectroscopy or the features of diffusion weighted (DW) imaging. The authors report the findings of classical MR imaging, MR spectroscopy and DW imaging of a 48-year-old woman and a 40-year-old woman with primary non-Hodgkin's lymphoma of breasts. Mammography and breast ultrasonography revealed a mass with circumscribed margin. The mass showed strong enhancement after contrast injection on MR imaging. DW imaging showed reduced diffusion and high-amplitude choline (Cho) peak at 3.22 ppm was detected by single voxel MR spectroscopy which was consistent with malignancy.

T1-Based MR Temperature Monitoring with RF Field Change Correction at 7.0T

  • Kim, Jong-Min;Lee, Chulhyun;Hong, Seong-Dae;Kim, Jeong-Hee;Sun, Kyung;Oh, Chang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.218-228
    • /
    • 2018
  • Purpose: The objective of this study is to determine the effect of physical changes on MR temperature imaging at 7.0T and to examine proton-resonance-frequency related changes of MR phase images and T1 related changes of MR magnitude images, which are obtained for MR thermometry at various magnetic field strengths. Materials and Methods: An MR-compatible capacitive-coupled radio-frequency hyperthermia system was implemented for heating a phantom and swine muscle tissue, which can be used for both 7.0T and 3.0T MRI. To determine the effect of flip angle correction on T1-based MR thermometry, proton resonance frequency, apparent T1, actual flip angle, and T1 images were obtained. For this purpose, three types of imaging sequences are used, namely, T1-weighted fast field echo with variable flip angle method, dual repetition time method, and variable flip angle method with radio-frequency field nonuniformity correction. Results: Signal-to-noise ratio of the proton resonance frequency shift-based temperature images obtained at 7.0T was five-fold higher than that at 3.0T. The T1 value increases with increasing temperature at both 3.0T and 7.0T. However, temperature measurement using apparent T1-based MR thermometry results in bias and error because B1 varies with temperature. After correcting for the effect of B1 changes, our experimental results confirmed that the calculated T1 increases with increasing temperature both at 3.0T and 7.0T. Conclusion: This study suggests that the temperature-induced flip angle variations need to be considered for accurate temperature measurements in T1-based MR thermometry.

Microwave and RF Heating for Medical Application under Noninvasive Temperature Measurement Using Magnetic Resonance

  • Nikawa, Yoshio;Ishikawa, Akira
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.244-249
    • /
    • 2010
  • Recent development of magnetic resonance imaging (MRI) equipment enables interventional radiology (IVR) as diagnosis and treatment under MRI usage. In this paper, a new methodology for magnetic resonance (MR) scanner to apply not only diagnostic equipment but for treatment one is discussed. The temperature measuring procedure under MR is to measure phase shift of $T_1$, which is the longitudinal relaxation time of proton, for the position inside a sample material with the application of pulsed RF for heating inside the sample as artificial dielectrics. The result shows the possibility to apply MR as temperature measuring equipment and as a heating equipment for applying such as hyperthermia heating modality.

$^{19}F$ MR Imaging of 5-FU Metabolism in Mice

  • Chaejoon Cheong;Lee, Seung-C.;Jae-G. Seo;Kim, Sung W.;Lee, Chulhyun;Kim, Chul S.;Taegyun Yang
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.5 no.2
    • /
    • pp.110-117
    • /
    • 2001
  • $^{19}$ F imaging of mice was carried out. For $^{19}$ F imaging, 5-flouro-uracil (5-FU) was injected into a mouse and in vivo detection of the catabolism of 5-FU to a-fluoro-P-alanine (FBAL) was carried out. The chemical shift selective (CHESS) imaging technique was employed. The 19F spectra and images give temporal and spatial information of the metabolism for 5-FU in mice.

  • PDF

Magnetic Resonance Imaging Evaluation of the Prostate in Normal Dogs

  • Cho, Yu-Gyeong;Choi, Ho-jung;Lee, Ki-ja;Lee, Youngwon
    • Journal of Veterinary Clinics
    • /
    • v.37 no.6
    • /
    • pp.317-323
    • /
    • 2020
  • The aims of this study were to describe the appearance and size of the normal canine prostate using magnetic resonance (MR) imaging and to calculate the apparent diffusion coefficient (ADC) values. MR images were obtained from seven intact male beagle dogs using a 1.5 T MR unit. The sequences included pre- and post-contrast T1- and T2-weighted imaging with and without fat saturation. The signal intensity of the prostate was compared with the adjacent musculature, fat, and urine in the urinary bladder. We recorded the mean prostatic length, width, and height and the length of the sixth lumbar vertebral body (L6). In addition, the prostatic length (rL), width (rW), and height (rH) ratios to L6 were calculated. Diffusion-weighted images of the prostate were obtained and ADC values were calculated. The prostate was bilobed and oval-shaped, homogenous on T1-weighted images, and heterogeneous with radiating lines on T2-weighted images. Post-contrast T1-weighted sequences showed contrast enhancement of the central and radiating striations. The prostatic capsule was clearly identified on post-contrast T1-weighted images with fat saturation. The ADC values were 1.72-2.04 × 10-3mm2/sec (mean, 1.88 × 10-3mm2/sec). Knowledge of the normal appearance of the prostate on MR images is essential to assess prostatic diseases in dogs.