• 제목/요약/키워드: Magnetic resonance images

검색결과 1,124건 처리시간 0.027초

Magnetic resonance images of ameloblastoma

  • Kim Jae-Duk;Kim Jin-Soo
    • Imaging Science in Dentistry
    • /
    • 제35권4호
    • /
    • pp.207-213
    • /
    • 2005
  • Purpose: To classify and describe the characteristic features of MRI of some ameloblastoma variants. Materials and Methods: The MR images, CT images, and panoramic radiographs in 5 cases were retrospectively examined as follows. First, the contents of ameloblastomas were devided into two portions of either solid or cystic components on the basis of MR signal intensities. The signal intensity within the solid or cystic portions was classified as homogeneous or heterogeneous. Next, the characteristic internal feature of the lesion on T1W1 or T2WI was described. The signal intensities were classified into low, intermediate, slightly high, high, and strong high signal intensity. Results: Unicystic lesion showed homogeneous high signal intensity (SI) on T2W2 and the rim enhancement of the surrounding area including the mural nodule and the thick wall except the central portion on Gd- T1W1. Solid type revealed heterogeneous and high SI area with strong high SI area on T2W2. On Gd- T1W1, the area corresponding to the low signal spot on T1W1 and the strong high signal spot on T2W1 showed low SI. Hybrid type showed slightly enhanced capsular structures and low SI for the round bony septa and the areas connecting the mixed and cystic lesions on T2Wl and Gd-T1W1. Conclusion: MRI could easily assess the relationship between the mixed and cystic findings in ameloblastoma.

  • PDF

Giant lipoma of the tongue: A case report and review of the literature

  • Yoon, Yeong-Ah;Kwon, Young-Eun;Choi, So-Young;Choi, Karp-Shik;An, Chang-Hyeon;An, Seo-Young
    • Imaging Science in Dentistry
    • /
    • 제52권1호
    • /
    • pp.117-121
    • /
    • 2022
  • This report presents the case of a 49-year-old man who presented with giant masses that had recently grown on the bilateral sides of the tongue. A clinical examination revealed rubbery yellowish lesions protruding from the tongue. A panoramic radiograph showed an enlarged soft tissue shadow of the tongue. Computed tomography showed well-defined circumscribed mass exhibiting a homogeneous low density on the bilateral sides of the tongue. On magnetic resonance images, the masses showed a high signal intensity on T1-weighted images and iso-signal intensity with partially hyperintense margin on fat-suppressed T2-weighted images. Surgical excision was performed, and a histopathologic examination confirmed the diagnosis of lipoma. The patient recovered well with no sign of recurrence. A giant lipoma is defined as a lipoma larger than 5 cm in diameter. A literature review of giant lipomas of the tongue is also presented herein.

정형보철용 금속을 이용한 자기공명영상왜곡의 정량적 평가 (Quantitative evaluation of MRI distortion using orthopedic prosthetic metal)

  • 김형균
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.57-62
    • /
    • 2013
  • 자기공명영상은 많은 장점에도 불구하고 체내에 정형보철이 있는 경우 자화율 차이로 영상왜곡이 발생한다. 스테인리스와 티타늄 시험편을 $65{\times}15{\times}2mm$로 동일하게 제작하여 phantom과 돼지고기에 부착 한 후 자기공명영상과의 관계를 알아보았다. phantom 영상을 통해 영상왜곡의 길이와 돼지 뼈를 통한 신호강도의 변화, 피하조직의 지방억제 정도를 정량적으로 평가 하였다. 스테인리스는 티타늄에 비해 길이 방향으로 4.4배, 높이 방향으로 2.8배 영상왜곡이 크며, 신호강도는 58.5%로 상대적으로 낮았다. 피하조직 지방억제는 Normal의 56.2%에 비해 스테인리스는 16.04%, 티타늄은 54.53%로 나타났다. 실험 결과 자기공명영상의 영상학적 진단가치는 스테인리스 보다 티타늄 금속이 부착 된 경우 더 우수한 것을 알 수 있었다.

치아 임플란트와 보철에서 발생하는 자기공명영상의 인공물 감소방안 연구 (A Study on the Artifact Reduction Method of Magnetic Resonance Imaging in Dental Implants and Prostheses)

  • 신운재
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.1025-1033
    • /
    • 2019
  • 뇌 질환과 두경부 검사에서 전산화단층촬영의 선속 경화현상이 없는 자기공명영상이 조직의 높은 대조도와 우수한 분해능의 영상을 획득하는 검사 방법으로 인식되고 있지만 구강 내 금속 이식물이 있는 경우는 자화율 인공물(magnetic susceptibility artifact)이 발생되어 영상 진단에 장해 요소가 된다. 따라서 본 연구는 자기공명영상에서 치아 임플란트와 보철에 의한 인공물 감소 방안을 강구하고자 한다. 자기공명영상에서 임플란트에 의한 인공물 발생은 GE 기법에서 TE가 짧을수록 신호 크기가 증가하였고, 물의 온도 변화에서는 일관성이 없게 나타났다. SE 기법에서도 공기보다 물의 신호 크기가 전반적으로 높았지만, 신호대 잡음비는 공기와 온도에 의한 차이가 없었다. EPI 기법에서는 공기보다 물이 있을 때 정량적, 정성적으로 인공물이 적게 발생한 영상을 얻을 수 있었고, 특히 물 온도 20°와 30°에서 신호 대 잡음비가 가장 높게 측정되었다. 결론적으로 EPI 기법에서 물 온도 20°와 30°의 물주머니를 이용하여 뇌 확산강조영상을 획득하면 임플란트와 보철물에 의한 자화율인공물이 감소되어 보다 진단적 가치가 있는 영상을 획득할 수 있을 것으로 사료된다.

Chemical Shift Artifact Correction in MREIT

  • Minhas, Atul S.;Kim, Young-Tae;Jeong, Woo-Chul;Kim, Hyung-Joong;Lee, Soo-Yeol;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.461-468
    • /
    • 2009
  • Magnetic resonance electrical impedance tomography (MREIT) enables us to perform high-resolution conductivity imaging of an electrically conducting object. Injecting low-frequency current through a pair of surface electrodes, we measure an induced magnetic flux density using an MRI scanner and this requires a sophisticated MR phase imaging method. Applying a conductivity image reconstruction algorithm to measured magnetic flux density data subject to multiple injection currents, we can produce multi-slice cross-sectional conductivity images. When there exists a local region of fat, the well-known chemical shift phenomenon produces misalignments of pixels in MR images. This may result in artifacts in magnetic flux density image and consequently in conductivity image. In this paper, we investigate chemical shift artifact correction in MREIT based on the well-known three-point Dixon technique. The major difference is in the fact that we must focus on the phase image in MREIT. Using three Dixon data sets, we explain how to calculate a magnetic flux density image without chemical shift artifact. We test the correction method through imaging experiments of a cheese phantom and postmortem canine head. Experimental results clearly show that the method effectively eliminates artifacts related with the chemical shift phenomenon in a reconstructed conductivity image.

MREIT of Postmortem Swine Legs using Carbon-hydrogel Electrodes

  • Minhas, Atul S.;Jeong, Woo-Chul;Kim, Young-Tae;Kim, Hyung-Joong;Lee, Tae-Hwi;Woo, Eung-Je
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.436-442
    • /
    • 2008
  • Magnetic resonance electrical impedance tomography(MREIT) has been suggested to produce cross-sectional conductivity images of an electrically conducting object such as the human body. In most previous studies, recessed electrodes have been used to inject imaging currents into the object. An MRI scanner was used to capture induced magnetic flux density data inside the object and a conductivity image reconstruction algorithm was applied to the data. This paper reports the performance of a thin and flexible carbon-hydrogel electrode that replaces the bulky and rigid recessed electrode in previous studies. The new carbon-hydrogel electrode produces a negligible amount of artifacts in MR and conductivity images and significantly simplifies the experimental procedure. We can fabricate the electrode in different shapes and sizes. Adding a layer of conductive adhesive, we can easily attach the electrode on an irregular surface with an excellent contact. Using a pair of carbon-hydrogel electrodes with a large contact area, we may inject an imaging current with increased amplitude primarily due to a reduced average current density underneath the electrodes. Before we apply the new electrode to a human subject, we evaluated its performance by conducting MREIT imaging experiments of five swine legs. Reconstructed conductivity images of the swine legs show a good contrast among different muscles and bones. We suggest a future study of human experiments using the carbon-hydrogel electrode following the guideline proposed in this paper.

2 단계 결정트리 학습을 이용한 뇌 자기공명영상 분류 (Classification of Brain Magnetic Resonance Images using 2 Level Decision Tree Learning)

  • 김형일;김용욱
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제34권1호
    • /
    • pp.18-29
    • /
    • 2007
  • 본 논문에서는 뇌 자기공명영상을 분류하기 위하여 결정트리 알고리즘을 2 단계로 적용하는 영상 분류 시스템을 제안한다. 영상으로부터 얻을 수 있는 정보에는 두 종류가 있다. 하나는 크기, 색상, 질감, 윤곽선 등 영상으로부터 직접 얻을 수 있는 하위레벨 특징들이고, 다른 하나는 특정 객체의 존재 유무, 여러 부위 사이의 공간적 관계 등 분할된 영상들에 대한 해석을 통해서 얻을 수 있는 상위레벨 특징들이다. 의미에 따라 영상을 분류하기 위해서는 상위레벨 특징들을 기반으로 학습 및 분류가 수행되어야 한다. 제안하는 시스템에서는 결정트리 학습을 각각의 레벨에 개별적으로 적용하며, 하위레벨 분류 결과를 이용하여 상위레벨의 특징을 추출한다. 종양이 있는 뇌 자기공명영상 집합에 대하여 분류 실험을 수행하였으며, 몇 가지 실험 결과를 통해 제안된 시스템의 효과를 확인하였다.

탄성파를 적용한 다중 위상 MR Elastography로부터의 점탄성 정수의 측정 (Measurement of Viscoelastic Constants from Multiple Phase MR Elastography Fitting Elastic Wave)

  • 정남채
    • 융합신호처리학회논문지
    • /
    • 제13권3호
    • /
    • pp.119-129
    • /
    • 2012
  • 의료분야에서 조직의 경화는 진단 또는 질환의 진행상황의 파악에 이용되는 중요한 정보의 한 가지이며, 객관적인 진단을 위해서는 경화의 정량적 계측법이 중요하다. 경화의 지표인 점탄성 정수를 비침습적으로 계측하는 방법으로 MRE(Magnetic Resonance Elastography) 법이 제안되고 있다. MRE 법에서는 전파파(propagating wave)의 국소 파장과 국소 감쇠율로부터 점탄성 정수를 구하는데 MRE 화상은 S/N 비가 낮아지므로, 잡음의 영향을 감소시키기 위하여 다중 위상 MRE 화상을 이용한 방법이 검토되고 있다. 본 연구에서는 다중 위상 MRE 화상에 함수를 적용하여 점탄성 정수를 측정하는 방법을 제안한다. 제안 방법은 다중 위상 MRE 화상에 점탄성파를 적용시키지만, 점탄성 정수의 공간방향으로의 변화율이나 화상에 포함된 잡음에 따라 측정값의 공간분해능을 임의적으로 설정할 수 있다는 장점이 있다. 시뮬레이션 화상을 이용한 실험과 silicone-gel phantom을 이용한 실험에 의하여 제안된 방법의 유효성을 확인하였다.

부비동 및 비강에 발생한 신경내분비암종의 영상소견: 자기공명영상을 중심으로 2예 보고 (MR Imaging Findings of Sinonasal Neuroendocrine Carcinoma: Two Case Reports)

  • 김정은;김루시아;임명관;박선원
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.127-132
    • /
    • 2007
  • 비강 및 부비동에 발생하는 신경내분비암종(neuroendocrine carcinoma)은 매우 드물고, 자기공명영상 소견에 대한 보고가 거의 없다. 이에 본 저자들은 비출혈을 주소로 내원한 62세 남자와 74세 남자에서 발생한 신경내분비암종의 2 증례에 대하여 전산화단층촬영과 자기공명영상의 소견을 중심으로 보고하고자 한다. 2예 모두 전산화단층촬영에서 비강과 부비동내에 비교적 크고 경계가 불분명한 종괴가 있었으며, 인접한 골 파괴를 동반하였다. 자기공명영상에서 종괴는 T1강조영상에서 등신호 강도를 보였고, T2강조영상에서는 등신호와 고신호가 섞여있는 양상을 보였으며, 조영 증강시 불균질한 조영 증강을 보였고 내부에는 괴사가 포함되어 있었다. 자기공명영상에서도 종괴에 인접한 골 파괴가 관찰되었다. 2예에서 모두 인접한 접형동내에 T1강조영상에서 고신호 강도를 보이는 점액낭 혹은 종양주변 낭성 부위가 관찰되었다. 2예 모두 전산화단층촬영과 자기공명영상에서 일반적인 비강과 부비동에 발생하는 악성 종양의 비특이적인 소견을 보였으나 종양 주변 낭성 부위의 의미에 대해서는 보다 많은 연구가 필요할 것으로 보인다.

  • PDF

Efficient Experimental Design for Measuring Magnetic Susceptibility of Arbitrarily Shaped Materials by MRI

  • Hwang, Seon-ha;Lee, Seung-Kyun
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권3호
    • /
    • pp.141-149
    • /
    • 2018
  • Purpose: The purpose of this study is to develop a simple method to measure magnetic susceptibility of arbitrarily shaped materials through MR imaging and numerical modeling. Materials and Methods: Our 3D printed phantom consists of a lower compartment filled with a gel (gel part) and an upper compartment for placing a susceptibility object (object part). The $B_0$ maps of the gel with and without the object were reconstructed from phase images obtained in a 3T MRI scanner. Then, their difference was compared with a numerically modeled $B_0$ map based on the geometry of the object, obtained by a separate MRI scan of the object possibly immersed in an MR-visible liquid. The susceptibility of the object was determined by a least-squares fit. Results: A total of 18 solid and liquid samples were tested, with measured susceptibility values in the range of -12.6 to 28.28 ppm. To confirm accuracy of the method, independently obtained reference values were compared with measured susceptibility when possible. The comparison revealed that our method can determine susceptibility within approximately 5%, likely limited by the object shape modeling error. Conclusion: The proposed gel-phantom-based susceptibility measurement may be used to effectively measure magnetic susceptibility of MR-compatible samples with an arbitrary shape, and can enable development of various MR engineering parts as well as test biological tissue specimens.