• Title/Summary/Keyword: Magnetic resonance (MR)

Search Result 1,190, Processing Time 0.027 seconds

CONTRAST-ENHANCED MR ANGIOGRAPHY : PRINCIPLES, IMPLEMENTATION, AND APPLICATIONS

  • Riederer, Stephen J.
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.117-122
    • /
    • 2002
  • Contrast-enhanced MR angiography has become a widely used method useful for clinical diagnosis. Early studies identified a number of technical issues, and many of these have been addressed with various MRI physics innovations over the last several years. The quality of the results is high enough that CE MRA is replacing conventional x-ray angiography methods at many institutions. Ongoing research is expected to provide further improvements in performance, most notably in additional reductions in examination time, in time-resolved 3D imaging, and in improved imaging of the peripheral vasculature with extended fields of view.

  • PDF

Collison Tumor of Adenocarcinoma and Diffuse Large B-Cell Lymphoma in the Rectum: a Case Report and Literature Review

  • Kim, See Hyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.4
    • /
    • pp.374-380
    • /
    • 2019
  • Collision tumor is a synchronous neoplasm wherein two histologically distinct tumors co-exist within the same anastomosis site. Collision tumor can occur in any organ, but the incidence is markedly rare. Additionally, preoperative diagnosis can be challenging to the radiologist. Herein, we report an age 60 male with collision tumor of rectal adenocarcinoma and diffuse large B-cell lymphoma, presented as a semi-annular wall thickening and bulky exophytic mass on MR imaging.

MR Spectroscopy and Diffusion Weighted Imaging Findings of Primary Non-Hodgkin Lymphoma of the Breast: Two Case Reports (유방에 발생한 일차성 비호지킨림프종의 자기공명 분광법 및 확산강조 영상: 2예)

  • Nam, Sang Yu;Yoo, Eun Young;Choi, Hye-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.176-181
    • /
    • 2014
  • Primary non-Hodgkin lymphoma (NHL) of the breast is a very rare disease, and the mammographic and ultrasonographic findings of breast lymphoma are variable. There are several reports of magnetic resonance (MR) imaging findings in patients with breast lymphomas; however, few reports have described the findings observed on MR spectroscopy or the features of diffusion weighted (DW) imaging. The authors report the findings of classical MR imaging, MR spectroscopy and DW imaging of a 48-year-old woman and a 40-year-old woman with primary non-Hodgkin's lymphoma of breasts. Mammography and breast ultrasonography revealed a mass with circumscribed margin. The mass showed strong enhancement after contrast injection on MR imaging. DW imaging showed reduced diffusion and high-amplitude choline (Cho) peak at 3.22 ppm was detected by single voxel MR spectroscopy which was consistent with malignancy.

Segmentation and Visualization of Head MR Image Based on Structural Approach (구조적인 기법을 이용한 머리 MR 단층 영상의 조직 분류 및 가시화)

  • 권오봉;김민기
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.283-290
    • /
    • 1999
  • Because MR(Magnetic Resonance) slice images have much information of functions about body organs, it is very effeclive for diagnoses lo analyze and visualize MR slice images. A visuahzation process is composed of medical image acquisition, preprocessmg, segmentation, inlerpolation, rendering. Segmentation and interpolation among thenl ,1re currenl hot topics because of MR slice image imperfections. This paper proposes a method for segmentalion, mlerpolation respectively and addresses 3 D-visualizmg of a head. We segmented head tissues uomg otructural knowledge of head studied by clinical experiments sequentially. We improved the dynamic elastic inlerpolation to Utilize in concave conlour. We compared the proposed segmentation method and the interpolation method with other methods.

  • PDF

Magnetic resonance imaging and spectroscopic analysis in 5 cases of Pelizaeus-Merzbacher disease: metabolic abnormalities as diagnostic tools

  • Lee, Eun;Yum, Mi-Sun;Choi, Hae-Won;Yoo, Han-Wook;You, Su Jeong;Lee, Eun-Hye;Ko, Tae-Sung
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.10
    • /
    • pp.397-402
    • /
    • 2012
  • Pelizaeus-Merzbacher disease (PMD) is a rare, X-linked recessive disorder characterized by dysmyelination in the central nervous system. PMD results from deletion, mutation, or duplication of the proteolipid protein gene (PLP1) located at Xq22, leading to the failure of axon myelination by oligodendrocytes in the central nervous system. PMD may be suspected when there are clinical manifestations such as nystagmus, developmental delays, and spasticity, and genetic analysis can confirm the diagnosis. Further diagnostic manifestations of the disease include a lack of myelination on brain magnetic resonance (MR) imaging and aberrant N-acetyl aspartate (NAA) and choline concentrations that reflect axonal and myelination abnormalities on phroton MR spectroscopy. We report 5 cases of PMD (in 1 girl and 4 boys). PLP1 duplication was detected in 2 patients. Brain MR analyses and MR spectroscopy were performed for all the patients. The brain MR images showed white matter abnormalities typical of PMD, and the MR spectroscopic images showed diverse patterns of NAA, creatinine, and choline concentrations. We propose that MR spectroscopic analysis of metabolic alterations can aid the PMD diagnosis and can contribute to a better understanding of the pathogenesis of the disease.

Reconsidering the "MR Unsafe" breast tissue expander with magnetic infusion port: A case report and literature review

  • Dibbs, Rami;Culo, Bozena;Tandon, Ravi;Hilaire, Hugo St.;Shellock, Frank G.;Lau, Frank H.
    • Archives of Plastic Surgery
    • /
    • v.46 no.4
    • /
    • pp.375-380
    • /
    • 2019
  • Breast tissue expanders (TEs) with magnetic infusion ports are labeled "MR Unsafe." Therefore, patients with these implants are typically prevented from undergoing magnetic resonance imaging (MRI). We report a patient with a total submuscular breast TE who inadvertently underwent an MRI exam. She subsequently developed expander exposure, requiring explantation and autologous reconstruction. The safety profile of TEs with magnetic ports and the use of MRI in patients with these implants is surprisingly controversial. Therefore, we present our case report, a systematic literature review, and propose procedural guidelines to help ensure the safety of patients with TEs with magnetic ports that need to undergo MRI exams.

The Utility Evaluation of Reconstructed 3-D Images by Maximum Intensity Projection in Magnetic Resonance Mammography and Cholangiopancreatography

  • Cho, Jae-Hwan;Lee, Hae-Kag;Park, Cheol-Soo;Kim, Ham-Gyum;Baek, Jong-Geun;Kim, Eng-Chan
    • Journal of Magnetics
    • /
    • v.19 no.4
    • /
    • pp.365-371
    • /
    • 2014
  • The aim of this study was to evaluate the utility of 3-D images by comparing and analyzing reconstructed 3-D images from fast spin echo images of MRI cholangiopancreatography (MRCP) images using maximum intensity projection (MIP) with the subtraction images derived from dynamic tests of magnetic resonance mammography. The study targeted 20 patients histologically diagnosed with pancreaticobiliary duct disease and 20 patients showing pancreaticobiliary duct diseases, where dynamic breast MR (magnetic resonance) images, fast spin echo imaged of pancreaticobiliary duct, and 3-D reconstitution images using a 1.5T MR scanner and 3.0T MR scanner were taken. As a result of the study, the signal-to-noise ratio in the subtracted breast image before and after administering the contrast agent and in the reconstructed 3-D breast image showed a high ratio in the reconstructed image of lesional tissue, relevant tissue, and fat tissue. However, no statistically meaningful differences were found in the contrast-to-noise ratio of the two images. In the case of the MRCP image, no differences were found in the ratios of the fast spin echo image and reconstructed 3-D image.

Carotid Intraplaque Hemorrhage is Associated with Acute Cerebral Ischemic Events and Progression of Stenosis on Magnetic Resonance Imaging

  • Ryu, Hye Ji;Jeon, Se Jeong;Choi, See Sung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.4
    • /
    • pp.242-251
    • /
    • 2017
  • Purpose: To investigate the association of carotid intraplaque hemorrhage (IPH) with acute cerebral ischemic events and progression of stenosis using magnetic resonance (MR) imaging. Materials and Methods: From April 2014 to December 2016, 53 patients underwent carotid plaque MR imaging, including magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequence. A total of 66 carotid arteries in 53 patients had carotid stenosis, and they were included in this study. Carotid arteries were classified according to the presence of IPH, the age of hemorrhage, and degree of stenosis. We assessed ipsilateral cerebrovascular event rates and progression of stenosis between the IPH and no-IPH groups. Results: Of the 61 carotid arteries assessed, 34 (56%) had IPH, and 27 (44%) had no IPH. Acute cerebral ischemic events were more frequent in the IPH group (47% vs. 22%, P = 0.045), especially in the < 30%-stenosis group (100% vs. 0%, P = 0.028). However, there was no significant difference in the incidence of ischemic events according to the age of hemorrhage (50% vs. 44%, P = 0.492). Among the 61 carotid arteries, 20 carotid arteries had previously undergone carotid artery imaging and were evaluated for plaque progression. The trend for progression of stenosis favored the IPH group versus the no-IPH group, with a marginal P-value ($20%{\pm}12.7$ vs. $9.6%{\pm}5.7$, P = 0.063). Conclusion: IPH was associated with an increased incidence of acute ischemic events, especially in the mild-stenosis group and it was also associated with progression of stenosis. Evaluation of the carotid IPH by carotid plaque MR could improve discrimination of carotid plaques that cause ischemic events and progression of stenosis.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

Brain Magnetic Resonance Image Segmentation Using Adaptive Region Clustering and Fuzzy Rules (적응 영역 군집화 기법과 퍼지 규칙을 이용한 자기공명 뇌 영상의 분할)

  • 김성환;이배호
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.525-528
    • /
    • 1999
  • Abstract - In this paper, a segmentation method for brain Magnetic Resonance(MR) image using region clustering technique with statistical distribution of gradient image and fuzzy rules is described. The brain MRI consists of gray matter and white matter, cerebrospinal fluid. But due to noise, overlap, vagueness, and various parameters, segmentation of MR image is a very difficult task. We use gradient information rather than intensity directly from the MR images and find appropriate thresholds for region classification using gradient approximation, rayleigh distribution function, region clustering, and merging techniques. And then, we propose the adaptive fuzzy rules in order to extract anatomical structures and diseases from brain MR image data. The experimental results shows that the proposed segmentation algorithm given better performance than traditional segmentation techniques.

  • PDF