• Title/Summary/Keyword: Magnetic moment

Search Result 327, Processing Time 0.025 seconds

Magnetic Properties of Carbon Chains Doped with 4d Transition Metals

  • Jang, Y.R.;Lee, J.I.
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.7-10
    • /
    • 2008
  • The structural and magnetic properties of functionalized carbon chains doped with 4d transition metals, such as Ru, Rh, and Pd, were investigated using the full-potential linearized augmented plane wave (FLAPW) method. The carbon nanowire doped with Ru exhibited a ferromagnetic ground state with a sizable magnetic moment, while those doped with Rh and Pd had nonmagnetic ground states. For the Ru-doped chain, the density of states at the Fermi level showed large spin polarization, which suggests that the doped nanowire could be used for spintronic applications.

A Practical Method to Correct the Saturation Effect in XMCD Spectra

  • Kim, J.Y.
    • Journal of Magnetics
    • /
    • v.13 no.3
    • /
    • pp.85-87
    • /
    • 2008
  • I report a simple method to correct the saturation effect in absorption spectra measured in total electron yield (TEY) mode. It does not require additional measurements of the X-ray penetration depth. In order to check the reliability of the method, X-ray magnetic circular dichroism (XMCD) spectra for polycrystalline Fe were measured at two different incident angles, and then processed with the method. The two resultant XMCD spectra were identical, and their sum rule analysis produced the ratios of orbital magnetic moment to spin magnetic moment, which were very close to the well-known value.

Analysis of the Driving Characteristics in the Magnetic Fluid Linear Pump by Operating Current (동작 전류에 의한 Magnetic fluid Linear Pump의 동특성 해석)

  • Seo, Kang;Park, Gwan-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.237-246
    • /
    • 2004
  • The advantages of the Magnetic Fluid Linear Pump(MFLP) is that this device could Pump the non-conductive. non-magnetic liquid such as Insulin or blood because of the segregation structure of the magnetic fluid and pumping liquid. In this device. the sequential currents are needed to Produce pumping forces so that Pumping Forces and Pumping speed mainly depend on the current Patterns. The excessive forces at Pumping moment could cause the medical shock, and weak forces at intermediate moment could cause the back flow or the pumping liquid. So the ripples of the pumping forces need to be reduced for the medical application. In this research, the driving characteristics in the MFLP by operating current is analysed. The change of magnetic fluid surface according to the driving currents could be obtained be magneto-hydrodynamic analysis so that Pumping fortes could be computed by integration of the surface moving to the pumping direction at each moment. The actual MFLP with 13mm diameter was made and tested for experiments. The effects of driving current and frequency on the pumping forces and pumping speed were analyzed and compared with experimental measurements.

Electronic Structure and Magnetism of Ni Monolyer Embedded Between Rh Layers (Ni 단층이 삽입된 Rh 박막의 전자구조와 자성)

  • Kim Sun-Hee;Jang Y.R.;Lee J.I.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.1
    • /
    • pp.7-11
    • /
    • 2005
  • A single slab in which one Ni(001) atom layer embedded between two of four Rh layers is considered to examine the oscillation of magnetic moment in each layer. The all electron total-energy full-potential linearized augmented plane wave(FLAPW) method was used to calculate the spin densities, magnetic moments, density of states(DOS), and the number of electrons within each muffin-tin(MT) sphere. The magnetic moment of the center layer Ni(C) in the system of 4Rh/Ni/4Rh is calculated to be 0.34${\mu}_B$, which is 40% have magnetic moment at the interface layers by strong band hybridization with Ni(C) when Ni(001) monolayers is inserted, and the magnetic moment shows a damped oscillation as we go from center Ni(C) layer to the surface Rh(S). From the calculated density of states, it is found that the Fermi level shifts inside the energy band of the Ni(C) in affection of Rh(001).

Analysis on Harmonics Characteristics of ELF Magnetic Fields Generated by Electric Appliances (가전기기 발생 극저주파 자계 고조파 특성 해석)

  • Min Suk-Won;Song Ki-Hyun;Yang Kwang-Ho;Ju Mun-No
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.31-37
    • /
    • 2005
  • With biological effects by ELF(Extremely Low Frequency) magnetic field generated from power system, the transient magnetic field from electric appliances is a major issue presently. In this paper, we measured magnetic field distributions around electric appliances in view of harmonics and analyzed them by the use of an equivalent magnetic dipole moment method. This method was applied to 19 types of appliances, and their equivalent magnetic dipole moments and harmonic components were determined. The results show that this method is applicable to many appliances and the higher frequency magnetic field may induce higher current inside living bodies.

Fluorine-Induced Local Magnetic Moment in Graphene: A hybrid DFT study

  • Kim, Hyeon-Jung;Jo, Jun-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.127.1-127.1
    • /
    • 2013
  • Recent experimental evidence that fluorinated graphene creates local magnetic moments around F adatoms has not been supported by semilocal density-functional theory (DFT) calculations where the adsorption of an F adatom induces no magnetic moment in graphene. Here, we show that such an incorrect prediction of the nonmagnetic ground state is due to the self-interaction error inherent in semilocal exchange-correlation functionals. The present hybrid DFT calculation for an F adatom on graphene predicts not only a spin-polarized ground state with a spin moment of ${\sim}1{\mu}_B$, but also a long-range spin polarization caused by the bipartite nature of the graphene lattice as well as the induced spin polarization of the graphene states. The results provide support for the experimental observations of local magnetic moments in fluorinated graphene.

  • PDF

Magnetic Properties of Cu-doped AlN Semiconductor (AlN 반도체와 Cu의 도핑 농도에 대한 자성)

  • Kang, Byung-Sub;Lee, Haeng-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.3
    • /
    • pp.1-4
    • /
    • 2010
  • First-principles calculations based on spin density functional theory are performed to study the spin-resolved electronic properties of AlN doped with a Cu concentration of 6.25%-18.75%. The ferromagnetic state is more energetically favorable state than the antiferromagnetic state or the nonmagnetic state. For $Al_{0.9375}Cu_{0.0625}N$, a global magnetic moment of 1.26 mB per supercell, with a localized magnetic moment of 0.75 $m_B$ per Cu atom is found. The magnetic moment is reduced due to an increase in the number of Cu atoms occupying adjacent cation lattice position. For $Al_{0.8125}Cu_{0.1875}N$, the magnetism of the supercell disappears by the interaction of the neighboring Cu atoms. The nonmagnetic to ferromagnetic phase transition is found to occur at this Cu concentration. The range of concentrations that are spin-polarized should be restricted within very narrow.

X-Ray Magnetic Circular Dichroism (X-선 자기 원형 이색성)

  • Kim, Jae-Young
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.5
    • /
    • pp.201-205
    • /
    • 2010
  • X-ray magnetic circular dichroism (XMCD) has been used as an important tool of magnetics due to its unique abilities to measure element-specific magnetic properties and to separate the orbital and the spin magnetic moments. These abilities allow researchers to access the microscopic origin of the magnetic properties of transition metal and rare earth compounds. In this report, I explain the principle of XMCD and the experimental set-up. Recent a few research examples using XMCD will be also introduced.

Electronic Structure and Magnetism of Fe Monolayer with Periodic Defects (주기적 결함을 가진 철 단층의 전자구조와 자성)

  • Landge, Kalpana K.;Bialek, Beata;Lee, Jae-Il
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.5
    • /
    • pp.161-164
    • /
    • 2009
  • The effect of periodic vacancies to the magnetism of the Fe monolayer was investigated by calculating the electronic structures using the full-potential linearized augmented plane wave method within the GGA approximation. We considered four types of vacancies, point defect, I type, + type, and H type which are consisted of one, three, five and seven vacant sites, respectively. We found that the Fe atoms nearest to the vacancy have the largest magnetic moment in each system, and the value of magnetic moment of the atom was increased as the number of vacancy site is increased. The value of the largest magnetic moment in the systems of point defect, I type, + type, and H type are 3.08, 3.09, 3.15, and 3.30 bohr magnetons, respectively.