• Title/Summary/Keyword: Magnetic film

Search Result 1,019, Processing Time 0.024 seconds

Extrapleural Pneumonectomy for the Anterior Mediastinal Liposarcoma with Invasion of Pleura and Lung -1 case report - (흉막 및 폐를 침범한 전종격동 지방육종에서의 흉막외 폐전적출술 - 1예 보고 -)

  • 박천수;김영태;성숙환;김주현
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.286-291
    • /
    • 2004
  • Mediastinum is a very rare primary site of liposarcoma. In general, wide surgical excision with adequate resection margin is the treatment of choice for lipesarcoma. We experienced a case of liposarcoma in a 24 year-old male who complained of dyspnea and chest discomfort. Symptoms had been developed a month before admission, and the intensity had been gradually increased. He visited another general hospital, and there he received left closed thoracostomy because hemothorax was suspected. Afterwards, he was transferred to our hospital without a specific diagnosis, on review of outside chest computed tomography film, mass shadow was detected in the mediastinum. For the further evaluation, we checked the chest sonography and chest magnetic resonance imaging. MRI showed 10 cm sized mass contacted with pulmonary artery trunk and left main pulmonary artery. The radiologist strongly suggested sarcoma. On the 4th day after admission, we performed emergent exploratory left thoracotomy for hematoma evacuation because mediastinal shifting progressed and heart rate was increased. Biopsy confirmed that the evacuated materials were extraskeletal myxoid chondresarcoma, so we performed extrapleural left pneumonectomy including diaphragm and a part of the pericardium. The final pathologic diagnosis was myxoid/round cell liposarcoma. He was discharged without complication and systemic chemotherapy was scheduled to begin 2 month later. During chemotherapy, local recurrence and peritoneal metastasis developed, and he died 10 month after the surgical excision. We report this case with reviewal of literature.

Statistical Study of the Ferguson's Angle, Lumbar Gravity Line and Lumbar Lordotic Angle in HIVD Patients. (요추간판탈출증 환자의 요천각, 요추중력중심선 및 요추전만각의 통계적 관찰)

  • Koh, Dong-Hyun;Hong, Soon-Sung;Lee, Jin-Ho;Jung, Sung-Yub;Shin, Joon-Shik
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.2 no.2
    • /
    • pp.17-32
    • /
    • 2007
  • Objectives : The lumbosacral joint is unstable area from an anatomical viewpoint, while it is also a very mobile area in ordinary life, so that clinically major causes of low back pain originate in this joint. The purpose of this study is to assess the difference of the Ferguson's angles, Lumbar gravity lines, Lumbar lordotic angles among Herniated of Intervertebral Disc(HIVD) patients. Methods : We analyzed the lateral view of lumbar spine checked at erect position on 88 patients who had been diagnosed as HIVD by Magnetic Resonance Imaging(MRI). We investigated the Ferguson's angle, Lumbar gravity line, Lumbar lordotic angle on X-ray film. Results and Conclusions : In the acute lumbago group the Ferguson's angle had a tendency to decrease, while in the chronic group it had a tendency to increase. In the acute lumbago group the Lumbar gravity line fell in front of the normal range(sacrum), while in the chronic group it fell behind the normal range(sacrum). In the acute lumbago group the Lumbar lordotic angle usually decreased, while in the chronic group it increased. The Ferguson's angle and the Lumbar gravity line, the Ferguson's angle and the Lumbar lordotic angle, the Lumbar gravity line and Lumbar lordotic angle each had a positive realtionship. The Ferguson's angle, the Lumbar gravity line and the Lumbar lordotic angle was less influenced by the level of HIVD and was more influenced by how long the patient had the pain. The correlationship between each factor was less in the chronic lumbago group than the acute group. In the chronic lumbago group the instability of the lumbosacral joint increased, while in the acute group the compression of the weight on the sacrum increased.

  • PDF

Employing Magnetic Resonance Imaging(MRI) in the Estimation of the Biomechanical Body Segment Parameters of Korean Adults (MRI에 의한 한국인 신체분절의 생체역학적 모수치 산출)

  • Joo, Young-Hwa
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.233-249
    • /
    • 2002
  • The purpose of this study was to employing MRI in the estimation of the biomechanical body segment parameters of Korean adults. for this purpose MRI study on 19 Korean living subjects were used to measurement. All the parameters that was concerned were inertial characteristics of human body mass of each segment, center of mass of them and the length of radius of gyration of them. The cross sectional images and saggital images of every 1cm interval were got using the 0.5 Tesla MRI from the top of head to the bottom of foot, whole body. And then, by tracing the images of the film and scanning them, got the area which the several tissues occupied in the image of slice. By summing the area of slice of each segment which were calculating and by multipling the density of the tissues, got the mass of segment and other inertial characteristics. The ratios of radius of gyration in both transverse axis and longitudinal axis though the segmental mass and segment length are as follow: male A : head($0.229\pm0.0029$), neck($0.256\pm0.0095$), thorax($0.374\pm0.0059$) abdomen($0.245\pm0.0020$), pelvis($0.368\pm0.0106$), thigh($0.288\pm0.0030$) shank($0.280\pm0.0043$), foot($0.277\pm0.0195$), upperarm($0.311\pm0.0074$) forearm($0.286\pm0.0051$), hand($0.253\pm0.0095$) female A : head($0.214\pm0.0032$), neck($0.254\pm0.0112$), thorax($0.295\pm0.0061$) abdomen($0.289\pm0.0021$), pelvis($0.329\pm0.0108$), thigh($0.288\pm0.0036$) shank($0.280\pm0.0047$), foot($0.243\pm0.0206$), upperarm($0.279\pm0.0083$) forearm($0.286\pm0.0048$), hand($0.229\pm0.0097$) male B : head($0.532\pm0.0006$), neck($0.533\pm0.0006$), thorax($0.658\pm0.0008$) abdomen($1.350\pm0.0022$), pelvis($0.875\pm0.0002$), thigh($0.213\pm0.0001$) shank($0.160\pm0.0001$), foot($0.152\pm0.0002$), upperarm($0.136\pm0.0002$) forearm($0.202\pm0.0002$), hand($0.273\pm0.0006$) female B : head($0.198\pm0.0002$), neck($0.335\pm0.0011$), thorax($0.238\pm0.0001$) abdomen($0.888\pm0.0001$), pelvis($1.318\pm0.0117$), thigh($0.095\pm0.0001$) shank($0.075\pm0.0001$), foot($0.181\pm0.0006$), upperarm($0.0.062\pm0.0001$) forearm($0.083\pm0.0001$), hand($0.105\pm0.0007$).

Development of Android-Based Photogrammetric Unmanned Aerial Vehicle System (안드로이드 기반 무인항공 사진측량 시스템 개발)

  • Park, Jinwoo;Shin, Dongyoon;Choi, Chuluong;Jeong, Hohyun
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.3
    • /
    • pp.215-226
    • /
    • 2015
  • Normally, aero photography using UAV uses about 430 MHz bandwidth radio frequency (RF) modem and navigates and remotely controls through the connection between UAV and ground control system. When using the exhausting method, it has communication range of 1-2 km with frequent cross line and since wireless communication sends information using radio wave as a carrier, it has 10 mW of signal strength limitation which gave restraints on life my distance communication. The purpose of research is to use communication technologies such as long-term evolution (LTE) of smart camera, Bluetooth, Wi-Fi and other communication modules and cameras that can transfer data to design and develop automatic shooting system that acquires images to UAV at the necessary locations. We conclude that the android based UAV filming and communication module system can not only film images with just one smart camera but also connects UAV system and ground control system together and also able to obtain real-time 3D location information and 3D position information using UAV system, GPS, a gyroscope, an accelerometer, and magnetic measuring sensor which will allow us to use real-time position of the UAV and correction work through aerial triangulation.

Comparison of Geometrical Factors of Dielectric Resonators Prepared for the Surface Resistance of Superconductor Films: Field Analysis vs. Computer Simulation (초전도체 박막의 표면저항 측정용 유전체 공진기에 대한 Geometrical factor의 비교 : 전자기장 해석 대 시뮬레이션)

  • Yang, Woo-Il;Jung, Ho-Sang;Kim, Myung-Su;Cho, Man-Soon;Choo, Kee-Nam;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • v.13 no.2
    • /
    • pp.97-104
    • /
    • 2011
  • In the dielectric resonator method, which has been widely used for measuring the microwave surface resistance of superconductors, accuracies in the geometrical factors (G-factors) affect the uncertainty in the measured surface resistance. We compare the G-factors of short-ended sapphire resonator as obtained by using field analysis with those by using computer simulations: The former is obtained by using the analytic expressions for the electric and the magnetic field components inside the resonator, and the latter by using computer software. The G-factors as obtained by using the latter appear to be closer to those obtained by using the former as the resonator space is divided into larger number of sub-space, i.e., a tighter mesh, with a difference of ~8 % observed for a mesh of 14400 sub-spaces reduced to ~2 % for 114996 sub-spaces. Variations in the relative uncertainty in the surface resistance of typical $YBa_2Cu_3O_{7-\delta}$ superconductor films with those in the G-factors are studied, which provides an upper limit of the relative uncertainty in the G-factors required for realizing the target uncertainty in the surface resistance. These results could be useful in estimating the optimum number of meshes for obtaining the G-factors through computer simulations.

High Frequency Properties of Fe93.5Si6.5 Magnetic Powder/Epoxy Composite Film (Fe93.5Si6.5 자성분말/에폭시 복합재 필름의 고주파 특성)

  • Hong, Seon-Min;Kim, Cheol-Gi
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.5
    • /
    • pp.195-199
    • /
    • 2008
  • Composites of $Fe_{93.5}Si_{6.5}$ powder and epoxy were prepared using a thermal curing process. Scanning electron microscope (SEM), vibrating sample magnetometer (VSM) and network analyzer were used to analyze the structure, electromagnetic properties and microwave absorption of the composites. Results show that the saturation magnetization depends on the fraction of the $Fe_{93.5}Si_{6.5}$ powder in the composite, which affects initial permeability. It is believed that the eddy current loss is a dominant factor over 1 GHz and that the resonance frequency of the composite decreases with increasing fractions of $Fe_{93.5}Si_{6.5}$ powder. Finally, reflection loss was calculated from the permeability and permittivity of these composites. Composite with 50 wt.% $Fe_{93.5}Si_{6.5}$ powder fractions and 5 mm thickness showed reflection loss below -20 dB from 3.66 GHz to 4.16 GHz. Therefore, it is believed that thin Fe-Si/epoxy composites may be a good candidate for microwave absorption application.

Evaluation of Cerebral Cortices Associated with Sexual Arousal in Healthy Male Using BOLD-based Functional MRI

  • Kim, Hyung-Joong;Seo, Jeong-Jin;Kang, Heoung-Keun;Jeong, Gwang-Woo;Park, Jin-Gyoon;Jeong, Yong-Yeon;Chung, Tae-Woong;Woong Yoon;Park, Kwang-Sung
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.137-137
    • /
    • 2001
  • Purpose: The purpose of this study was to identify cerebral cortices related with sexual arousal fro visual sexual stimulation in healthy males using BOLD-based functional MR imaging Method: Sixteen male volunteers with sexually potent(mean age:24) were examined for thi study. Functional MRI was performed on a 1.5T MR scanner(GE Signa Horizon) with birdcage-type head coil. In this study, blood oxygenation level dependent(BOLD) technique was utilized to create fMR image reflecting local brain activities. The BOLD-based fMRI d were obtained from 7 oblique planes using gradient-echo EPI with $90^{\circ}$flip angle, 50ms TE 6000ms TR, $26cm{\times}26$ cm FOV, $128{\times}128$ matrix, and 10mm slice thickness. The sexual stimulation paradigm consisted of two alternating periods of rest and activati and it began with a 1 minute rest, followed by a 2 minute stimulation by a documentary a erotic video film. Brain activation maps were generated by cross-correlation of imag acquired during rest and activation periods. The index of activation was used to compare t number of pixels activated by each task in each volunteer, where the significance of th differences was evaluated by using Students t-test.

  • PDF

Characteristics of the Flux-lock Type Superconducting Fault Current Limiter According to the Iron Core Conditions (자속구속형 초전도 전류제한기의 철심조건에 따른 특성)

  • Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Cho, Guem-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.7
    • /
    • pp.38-45
    • /
    • 2006
  • The superconducting fault current limiters(SFCLs) provide the effect such as enhancement in power system reliability due to limiting the fault current within a few miliseconds. Among various SFCLs we have developed a flux-lock type SFCL and exploited a special design to effectively reduce the fault current according to properly adjustable magnetic field after the short-circuit test. This SFCL consists of two copper coils wound in parallel on the same iron core and a component using the YBCO thin film connected in series to the secondary copper coil. Meanwhile, operating characteristics can be controlled by adjusting the inductances and the winding directions of the coils. To analyze the operational characteristics, we compared closed-loop with open-loop iron core. When the applied voltage was 200[Vrms] in the additive polarity winding, the peak values of the line current the increased up to 30.71[A] in the closed-loop and 32.01[A] in the open-loop iron core, respectively. On the other hand, in the voltages generated at current limiting elements were 220.14[V] in the closed-loop and 142.73[V] in the opal-loop iron core during first-half cycle after fault instant under the same conditions. We confirmed that the open-loop iron core had lower power burden than in the closed-loop iron core. Consequently, we found that the structure of iron core enabled the flux-lock type SFCL at power system to have the flexibility.

Structural and Magnetic Properties of Fe Doped CuO (Fe 첨가된 CuO의 구조적, 자기적 특성)

  • Park, Young-Ran;Kim, Kwang-Joo;Park, Jae-Yun;Ahn, Geun-Young;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.1
    • /
    • pp.34-39
    • /
    • 2006
  • Pure and Fe-doped CuO thin-film and powder samples were prepared using a sol-gel method. Undoped CuO films exhibited monoclinic structure and p-type electrical conductivity $(\~10^{-2}\;{\Omega^{-1}\;cm^{-1}$ due to copper deficiency. On the other hand, CuO: Fe films were found to be insulating and Li doping on the films led to a restoration of p-type conductivity and a ferromagnetic hysteresis behaviour at room temperature. The observed properties far the CuO : Fe, Li films can be explained in terms of hole creation by substitution of $Li^+$ for $Cu^{2+}$ sites and mediation of long-range interactions between $Fe^{3+}$ ions by the $Li^+$-induced defect states. CuO: Fe powders exhibited a ferromagnetism at room temperature with its strength being dependent on post-annealing temperature. Mossbauer measurements on the CuO: Fe films and powders revealed that the octahedral $Cu^{2+}$ sites are mostly substituted by $Fe^{3+}$ ions.

Magnetoresistance Properties in Synthetic CoFe/Ru/CoFe/FeMn Spin Valves with Different Pinned Layer Thicknesses (합성형 반강자성체인 CoFe/Ru/CoFe/FeMn에서 고정층의 두께 차이에 따른 스핀 밸브 구호의 자기저항 특성)

  • 김광윤
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.5
    • /
    • pp.211-216
    • /
    • 2001
  • Top synthetic spin valves wi th structure Ta/NiFe/CoFe/Cu/CoFe(Pl)/Ru/CoFe(P2)/FeMn/Ta on Si (100) substrate with SiO$_2$ of 1500 were prepared by dc magnetron sputtering system. We have changed only the thickness of the free layer and the thickness difference (Pl-P2) in the two ferromagnetic layers separated by Ru, and investigated the effect of magnetic film thickness on the GMR properties and the interlayer coupling field in a spin valve with a synthetic antiferromagnet. As thickness difference of pinned layer was decreased from +25 to -25 , MR ratio was decreased gradually. However, there was a dip zone indicating a big change of MR ratio around Pl = P2, which can be due to the large canting of pinned layers. The modified Neel model was suggested for the top synthetic spin valve to explain the interlayer coupling field according to the thickness change of ferromagnetic layers. The interlayer coupling field was decreased due to the magnetostatic coupling (orange peel coupling) as suggested by model. However, the interlayer coupling field was not explained at the dip zone by the modified Neel model. The deviation of modified Neel model at the dip zone could be due to the largely canting of the pinned layers as well, which depends on different thickness in synthetic antiferromagnetic structure.

  • PDF