Quantitative Analysis of Brain Metabolite Spectrum Depending on the Concentration of the Contrast Media in Phantom (팬텀 내 조영제 농도에 따른 뇌 대사물질 Spectrum의 정량분석)

  • Shin, WoonJae;Gang, EunBo;Chun, SongI
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 2015
  • Quantitative analysis of MR spectrum depending on mole concentration of the contrast media in cereberal metabolite phantom was performed. PRESS pulse sequence was used to obtain MR spectrum at 3.0T MRI system (Archieva, Philips Healthcare, Best, Netherland), and the phantom contains brain metabolites such as N-Acetyl Asparatate (NAA), Choline (Cho), Creatine (Cr) and Lactate (Lac). In this study, optimization of MRS PRESS pulse sequency depending on the concentration of contrast media (0, 0.1 and $0.3mmol/{\ell}$) was evaluated for various repetition time(TR; 1500, 1700 and 2000 ms). In control (cotrast-media-free) group, NAA and Cho signals were the highest at TR 2000 ms than at 1700 and 1500 ms. Cr had the highest peak signal at TR 1500 ms. When concentration of contrast media was $0.1mmol/{\ell}$, the metabolites were increased NAA 73%, Cho 249%, Cr 37% at TR 1700 ms compared with other TR, and also signal increased at $0.3mmol/{\ell}$, In $0.5mmol/{\ell}$ of contrast agent, cerebral metabolite peaks reduced, especially when TR 1500 ms and 2000 ms they decreased below those of control group. The ratio of metabolite peaks such as NAA/Cr and Cho/Cr decreased as the concentration of the contrast agent increased from 0.1 to $0.5mmol/{\ell}$. Authors found that the optimization of PRESS sequence for 0.3T MRS was as follows: low density of contrast agent ($0.1mmol/{\ell}$ and $0.3mmol/{\ell}$) made the highest signal intensity, while high density of contrast agent reveals the least reduction of signal intensity at 1700 ms. In conclusion, authors believe that it is helpful to reduce TR for acquiring maximum signal intensity.

THE ELECTROMAGNETIC CHARACTERISTICS OF THE POLAR IONOSPHERE DURING A MODERATELY DISTURBED PERIOD (지자기교란시 극전리층의 전자기적인 특성)

  • 안병호
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.216-233
    • /
    • 1995
  • The distributions of the ionospheric conductivities, electric potential, ionospheric currents, field-aligned currents, Joule heating rate, and particle energy input rate by auroral electrons along with the characteristics of auroral particle spectrum are examined during moderately disturbed period by using the computer code developed by Kamide et al. (1981) and the ionospheric conductivity model developed by Ahn et al. (1995). Since the ground magnetic disturbance data are obtained from a single meridian chain of magnetometers (Alaska meridian chain) for an extended period of time (March 9 - April 27, 1978), they are expected to present the average picture of the electrodynamics over the entire polar ionosphere. A number of global features noted in this study are as follows: (1) The electric potential distribution is characterized by the so-called two cell convection pattern with the positive potential cell in the morning sector extending into the evening sector. (2) The auroral electrojet system is well developed during this time period with the signatures of DP-1 and DP-2 current systems being clearly discernable. It is also noted that the electric field seems to play a more important role than the ionospheric conductivity the conductivity over the poleward half of the westward electrojet in the morning sector while the conductivity enhancement seems to be more important over its equatorward half. (3) The global field-aligned current distribution pattern is quite comparable with the statistical result obtained by Iijima and Potemra (1976). However, the current density of Region 1 is much higher than that of Region 2 current at pointed out by pervious studies (e.g.; Kamide 1988). (4) The Joule heating occurs over a couple of island-like areas, one along the poleward side of the westward electrojet region in the afternoon sector. (5) The maximum average energy of precipitating electrons is found to be in the morning sector (07∼08 MLT) while the maximum energy flux is registered in the postmidnight sector (02 MLT). Thus auroral brightening and enhancement of ionospheric conductivity during disturbed period seem to be more closely associated with enhancement of particle flux rather than hardening of particle energy.

  • PDF

A Study of Power Perception between Supplier and Retail Buyer of Agricultural Products (농산물공급자와 대형소매업체 바이어간의 상호 파워 인식에 대한 연구)

  • 서성무;이은정
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2003.02a
    • /
    • pp.123-166
    • /
    • 2003
  • Marketing channel is recognized as one of the society systems which have the character of functional organization. These organizations are related to each other for specialized and cooperative work. Channel members in distribution channel are striving to accomplish exchange through reciprocal action. Thus channel members exercise their power to take better position in exchange. There will be struggling between members about satisfaction and conflict during this power exercise. Now a days, buyers use more harsh power as large retail firms are increasing. This phenomenon is occurring in the distribution channel. However, there will be different phenomenon in case of agricultural products. Not like industrial product suppliers, agricultural product suppliers have various supply channels and many agricultural products are seasonal. It has also unstable amount supplies. There should be differentiated marketing in agricultural products. Relatively weaker powered suppliers have to strengthen comparative factors and also have to be technically specialized through assessed experience in order to establish strong product sales chain. Making a brand of agricultural product would be also a good idea to increase the product comparability. Channel members need to be recognized their specialized functions in order to make balanced distribution channel. There have to be conversion of concept of relation between suppliers and buyers from subordinate relationship to cooperative relationship.

  • PDF

Retrospective Evaluation of Discrepancies between Radiological and Pathological Size of Hepatocellular Carcinoma Masses

  • Tian, Fei;Wu, Jian-Xiong;Rong, Wei-Qi;Wang, Li-Ming;Wu, Fan;Yu, Wei-Bo;An, Song-Lin;Liu, Fa-Qiang;Feng, Li;Liu, Yun-He
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9487-9494
    • /
    • 2014
  • Background: The size of a hepatic neoplasm is critical for staging, prognosis and selection of appropriate treatment. Our study aimed to compare the radiological size of solid hepatocellular carcinoma (HCC) masses on magnetic resonance imaging (MRI) with the pathological size in a Chinese population, and to elucidate discrepancies. Materials and Methods: A total of 178 consecutive patients diagnosed with HCC who underwent curative hepatic resection after enhanced MRI between July 2010 and October 2013 were retrospectively identified and analyzed. Pathological data of the whole removed tumors wereassessed and differences between radiological and pathological tumor size were identified. All patients were restaged using a modified Tumor-Node-Metastasis (TNM) staging system postoperatively according to the maximum diameter alteration. The lesions were classified as hypo-staged, iso-staged or hyper-staged for qualitative assessment. In the quantitative analysis, the relative pre and postoperative tumor size contrast ratio ($%{\Delta}size$) was also computed according to size intervals. In addition, the relationship between radiological and pathological tumor diameter variation and histologic grade was analyzed. Results: Pathological examination showed 85 (47.8%) patients were overestimated, 82 (46.1%) patients underestimated, while accurate measurement by MRI was found in 11 (6.2%) patients. Among the total subjects, 14 (7.9%) patients were hypo-staged and 15 (8.4%) were hyper-staged post-operatively. Accuracy of MRI for calculation and characterized staging was related to the lesion size, ranging from 83.1% to 87.4% (<2cm to ${\geq}5cm$, p=0.328) and from 62.5% to 89.1% (cT1 to cT4, p=0.006), respectively. Overall, MRI misjudged pathological size by 6.0 mm (p=0.588 ), and the greatest difference was observed in tumors <2cm (3.6 mm, $%{\Delta}size=16.9%$, p=0.028). No statistically significant difference was observed for moderately differentiated HCC (5.5mm, p=0.781). However, for well differentiated and poorly differentiated cases, radiographic tumor maximum diameter was significantly larger than the pathological maximum diameter by 3.15 mm and underestimated by 4.51 mm, respectively (p=0.034 and 0.020). Conclusions: A preoperative HCC tumor size measurement using MRI can provide relatively acceptable accuracy but may give rise to discrepancy in tumors in a certain size range or histologic grade. In pathological well differentiated subjects, the pathological tumor size was significantly overestimated, but underestimated in poorly differentiated HCC. The difference between radiological and pathological tumor size was greatest for tumors <2 cm. For some HCC patients, the size difference may have implications for the decision of resection, transplantation, ablation, or arterially directed therapy, and should be considered in staging or selecting the appropriate treatment tactics.

Analysis of utilization and profit for CT and MRI after implementation of insurance coverage for CT (CT 보험급여 전후의 CT 및 MRI검사의 이용량과 수익성 변화)

  • Suh, Chong-Rock;Yu, Seung-Hum;Chun, Ki-Hong;Nam, Chung-Mo
    • Korea Journal of Hospital Management
    • /
    • v.2 no.1
    • /
    • pp.1-21
    • /
    • 1997
  • In order to analyze the shifts in the volume and profits of Computed Tomography(CT) and Magnetic Resonance Imaging(MRI) utilization for a year before and after the implementation of insurance coverage for CT, this study has been undertaken examining CT and MRI cost data from 'Y' University Hospital situated in Seoul, Korea. Following are the results of this study: 1. The medical insurance payment for CT, implemented on January 1, 1996, increased CT utilization from January 1996 to April 1996 due to low insurance premiums: however, from May 1996 the number of CT cases significantly decreased as a result of strengthened medical cost reviews and the new 'Detailed standards for approval of CT' announced near the end of April 1996 by the insurer. 2. Since the implementation of insurance coverage for CT, CT fee reduction rates for reimbursements by the insurer to the hospital were 50% and 40% for January and February, respectively, and 31% and 15% for March and April. A significant point in the lowering of the reduction rate was reached in May at 11%; furthermore, since June the reduction rate fell below the average reduction rate for reimbursements for all procedures. If the 'Detailed standards for approval of CT' had been announced before the implementation of insurance coverage for CT, CT utilization would not have been so high due to the need to meet those 'standards'. In addition, loss of hospital profits resulting from the reduction for reimbursements would not have occurred. 3. The shifts in MRI utilization showed that there was no particular change with the beginning of insurance coverage for CT, and the introduction of the 'Detailed standards for approval of CT' made MRI utilization increase because MRI is free of restrictions imposed by the insurer. 4. The relationship between CT utilization and MRI utilization showed that they were supplementary to each other before insurance coverage for CT, but that CT was substituted for MRI because of strengthened medical cost reviews after t~e beginning of insurance coverage for CT. 5. The shifts in volume by patient characteristics showed that the number of inappropriate case patients, according to the insurer's "Standards for approval", decreased more than the number of appropriate case patients after the introduction of insurance coverage for CT. Therefore, the health insurance fee schemes for CT have influenced patient care. 6. The shifts in profits from CT utilization showed a net profit decrease of 31.6%. In order to match the pre-coverage profit level, 5,471 more cases would need to be seen and productivity would need to be increased by 32.7%. This profit decrease resulted from a decrease of CT utilization and low reimbursements. With insurance coverage, net profits from CT were 24.4%, and a margin of safety ratio was 39.6%. Because of the net profits and margin of safety ratio, CT utilization fees for insured appropriate cases could not be considered inappropriate. 7. The shifts in profits from MRI utilization before and after the introduction of CT coverage showed that in order to match pre-CT coverage profit levels, 2,011 more cases would need to be seen and productivity would need to be increased by 9.2%. The reasons for needing to increase the number of cases and productivity result from cost burdens created by adding new MRI units. But with CT coverage already begun, MRI utilization increased. Combined with a minor increase in the MRI fee schedule, MRI utilization showed a net profit increase of 18.5%. Net profits of 62.8% and a 'margin of safety ratio' of 43.1% for MRI utilization showed that the hospital relied on this non-covered procedure for profits. 8. The shifts in profits from CT and MRI utilization showed the net profits from CT decreased by 2.33billion Won while the net profits from MRI increased by 815.7million Won. Overall, these two together showed a net profit decrease of 1.51billion Won. The shifts in utilization showed a functional substitutionary relationship, but the shifts in profits did not show a substitutionary relationship. From these results, We can conclude that if insurance is to be expanded to include previously uncovered procedures using expensive medical equipment, detailed standards should be prepared in advance. The decrease in profits from the shifts in coverage and changes in fees is a difficult burden that should be shared, not carried by the hospital alone. Also, a new or improved fee schedule system should include revised standards between items listed and the appropriateness of the fee schedule should constantly be ensured. This study focused on one university hospital in Seoul and is therefore limited in general applicability. But it is valuable for considering current issues and problems, such as the influence of CT coverage on hospital management. Future studies will hopefully expand the scope of the issues considered here.

  • PDF

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

X-linked Adrenoleukodystrophy in Childhood (X 염색체 연관 부신백질이영양증 환아들의 임상양상)

  • Yoo, Eun Jung;Kim, Eun Young;Kook, Hoon;Woo, Young Jong
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.5 no.1
    • /
    • pp.33-43
    • /
    • 2005
  • Purpose: X-linked adrenoleukodystrophy(ALD) is a rare disorder that shows a great deal of phenotypic variability. We subdivided chidhood X-linked ALD patients into several phenotypes by the age at onset, the sites of most severe clinical involvement and the rate of progression of neurologic symptoms. Methods: Thirteen patients who had been diagnosed as X-linked ALD and followed up for at least one year were enrolled from 1996 to 2003. Results: 1. Ten had childhood cerebral ALD, who showed first neurologic symptoms at 7.02 years and progressed rapidly: interval between first symptoms and vegetative state was 1.35 years, and interval from initial symptoms to death was 3.35 years. Treatment with Lorenzo's oil did not prevent neurologic progression. Two patients who underwent umbilical cord blood transplantation died. 2. Two had adolescent cerebral ALD. They had first symptoms at 11.5 years, and showed tendency to progress less rapidly than childhood cerebral form patients. 3. One "Addison only" patient who had adrenal insufficiency without nervous system involvement remained asymptomatic during Lorenzo's oil treatment. 4. All cerebral form patients except one showed the lesions in both parieto-ocipital white matter in brain magnetic resonance imaging. Conclusion: The cerebral ALD was the most common form in childhood and was asoociated with a serious prognosis.

  • PDF

Reaction Gas Composition Dependence on the Properties of SnO2 Films on PET Substrate by ECR-MOCVD (반응가스조성이 PET기판위에 ECR 화학증착법에 의해 제조된 SnO2 박막특성에 미치는 영향)

  • Kim, Yun-Seok;Lee, Joong-Kee
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.3
    • /
    • pp.139-145
    • /
    • 2005
  • [ $SnO_x$ ] films on the flexible substrate of PET film were prepared at ambient temperature under a $(CH_3)_4Sn(TMT: tetra-methyl tin)-H_2-O_2$ atmosphere in order to obtain transparent conductive polymer by using ECR-MOCVD(Electro Cyclotron Resonance Metal Organic Chemical Yfpor Deposition) system. The prepared $SnO_x$ thin films show generally over $90\%$ of optical transmittance at wavelength range of 380-780nm and about $1\times10^{-2\~3}ohm{\cdot}cm$ of electrical resistivity. In the present study, effects of $O_2/TMT\;and\;H_2/TMT$ mole ratio on the properties of $SnO_x$ films are investigated and the other process parameters such as microwave power, magnetic current power, substrate distance and working pressure are fixed. Based on our experimental results, the $SnO_x$ film composition ratio of Sn and O directly influences on the electrical and optical properties of the films prepared. The $SnO_x$ film with low electric resistivity and high transmittance could be obtained by controlling the process parameters such as $O_2/TMT\;and\;H_2/TMT$ mole ratio, which play an important role to change the composition ratio between Sn and O. An increase of $O_2/TMT$ mole ratio brought on the increases 0 content in the $SnO_x$ film. On the other hand, an increase of $H_2/TMT$ mole ratio lead to decreases the oxygen content in the film. The optimized composition ratio of oxygen : tin Is determined as 2.4: 1 at $O_2/TMT$ of 80 and $H_2/TMT$ of 40 mole ratio, respectively.

Effect of Lead Content on Atomic Structures of Pb-bearing Sodium Silicate Glasses: A View from 29Si NMR Spectroscopy (납 함량에 따른 비정질 Pb-Na 규산염의 원자 구조에 대한 고상 핵자기 공명 분광분석 연구)

  • Lee, Seoyoung;Lee, Sung Keun
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.3
    • /
    • pp.157-167
    • /
    • 2021
  • Lead (Pb) is one of the key trace elements, exhibiting a peculiar partitioning behavior into silicate melts in contact with minerals. Partitioning behaviors of Pb between silicate mineral and melt have been known to depend on melt composition and thus, the atomic structures of corresponding silicate liquids. Despite the importance, detailed structural studies of Pb-bearing silicate melts are still lacking due to experimental difficulties. Here, we explored the effect of lead content on the atomic structures, particularly the evolution of silicate networks in Pb-bearing sodium metasilicate ([(PbO)x(Na2O)1-x]·SiO2) glasses as a model system for trace metal bearing natural silicate melts, using 29Si solid-state nuclear magnetic resonance (NMR) spectroscopy. As the PbO content increases, the 29Si peak widths increase, and the maximum peak positions shift from -76.2, -77.8, -80.3, -81.5, -84.6, to -87.7 ppm with increasing PbO contents of 0, 0.25, 0.5, 0.67, 0.86, and 1, respectively. The 29Si MAS NMR spectra for the glasses were simulated with Gaussian functions for Qn species (SiO4 tetrahedra with n BOs) for providing quantitative resolution. The simulation results reveal the evolution of each Qn species with varying PbO content. Na-endmember Na2SiO3 glass consists of predominant Q2 species together with equal proportions of Q1 and Q3. As Pb replaces Na, the fraction of Q2 species tends to decrease, while those for Q1 and Q3 species increase indicating an increase in disproportionation among Qn species. Simulation results on the 29Si NMR spectrum showed increases in structural disorder and chemical disorder as evidenced by an increase in disproportionation factor with an increase in average cation field strengths of the network modifying cations. Changes in the topological and configurational disorder of the model silicate melt by Pb imply an intrinsic origin of macroscopic properties such as element partitioning behavior.

Non-invasive Brain Stimulation and its Legal Regulation - Devices using Techniques of TMS and tDCS - (비침습적 뇌자극기술과 법적 규제 - TMS와 tDCS기술을 이용한 기기를 중심으로 -)

  • Choi, Min-Young
    • The Korean Society of Law and Medicine
    • /
    • v.21 no.2
    • /
    • pp.209-244
    • /
    • 2020
  • TMS and tDCS are non-invasive devices that treat the diseases of patients or individual users, and manage or improve their health by applying stimulation to a brain through magnetism and electricity. The effect and safety of these devices have proved to be valid in several diseases, but research in this area is still much going on. Despite increasing cases of their application, legislations directly regulating TMS and tDCS are hard to find. Legal regulation regarding TMS and tDCS in the United States, Germany and Japan reveals that while TMS has been approved as a medical device with a moderate risk, tDCS has not yet earned approval as a medical device. However, the recent FDA guidance, European MDR changes, recalls in the US, and relevant legal provisions of Germany and Japan, as well as recommendations from expert groups all show signs of tDCS growing closer to getting approved as a medical device. Of course, safety and efficacy of tDCS can still be regulated as a general product instead of as a medical device. Considering multiple potential impacts on a human brain, however, the need for independent regulation is urgent. South Korea also lacks legal provisions explicitly regulating TMS and tDCS, but they fall into the category of the grade 3 medical devices according to the notifications of the Korean Ministry of Food and Drug Safety. And safety and efficacy of TMS are to be evaluated in compliance with the US FDA guidance. But no specific guidelines exist for tDCS yet. Given that tDCS devices are used in some hospitals in reality, and also at home by individual buyers, such a regulatory gap must quickly be addressed. In a longer term, legal system needs to be in place capable of independently regulating non-invasive brain stimulating devices.