• Title/Summary/Keyword: Magnetic Field modulation

Search Result 36, Processing Time 0.022 seconds

Magneto-optical Measurements of Semiconductor Quantum Structures in Pulsed-magnetic Fields

  • Kim, Yongmin
    • Applied Science and Convergence Technology
    • /
    • v.23 no.1
    • /
    • pp.1-13
    • /
    • 2014
  • Semiconductor quantum structures are often characterized by their energy gaps which are modified by the quantum size effect. Energy levels in semiconductors can be realized by optical transitions within confined structures. Photoluminescence spectroscopy in magnetic fields at low temperatures has proved to be a powerful technique for investigating the electronic states of quantum semiconductor heterostructures and offers a complimentary tool to electrical transport studies. In this review, we examine comprehensive investigations of magneto-excitonic and Landau transitions in a large variety of undoped and doped quantum-well structures. Strong magnetic fields change the diamagnetic energy shift of free excitons from quadratic to linear in B in undoped single quantum well samples. Two-dimensional electron gas induced by modulation doping shows pronounce quantum oscillations in integer quantum Hall regime and discontinuous transition at ${\nu}=1$. Such discontinuous transition can be explained as the formation of spin waves or Skyrmions.

The Effect of the Guard Ring around the Emitter on the Sensitivity of the Highly Sensitive Separated Drift Field Magnetotransistor (에미터 주위의 guard ring이 분리된 전계를 갖는 고감도 자기 트랜지스터의 민감도에 미치는 영향)

  • Kang, Uk-Song;Lee, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1413-1415
    • /
    • 1994
  • A novel magnetotransistor using a separated drift field with the guard ring around the emitter has been designed and fabricated. The operating principle of the proposed magnetic field sensor is based on the emitter injection modulation. The $p^+$ guard ring around the n-type emitter confines drifted electrons in the emitter, hence the induced Hall voltage in the emitter is increased. The measured relative sensitivity of the separated drift magnetotransistor with the guard ring is about 100 times larger than that without the guard ring.

  • PDF

Study on the Implementation of the Digital Controller of High-Speed PWM Current Amplifier (디지털 제어 방식의 고속 PWM 전류 증폭기의 구현에 관한 연구)

  • Ko, Deog-Hwa;Baek, Kwang-Ryul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.2
    • /
    • pp.97-103
    • /
    • 2002
  • This paper deals with a PWM(Pulse Width Modulation) current amplifier using digital controller in order to generate a gradient magnetic field far the MRI(Magnetic Resonance Image) system. Because of tolerance of discrete devices, it is difficult to set accurate values of the control parameters and to make an analog-controlling circuit. However, using digital controller, it is possible to set exact control parameters and to adopt a modern control techniques. It is shown that the digital controller will highly enhance the output current response and it will improve the quality of the MRI.

A study on the PWM type High Speed Electromagnet (PWM 방식 고속 전자석에 관한 연구)

  • Song, Chang-Seop;Yang, Hae-Jeong;Song, Sung-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.6
    • /
    • pp.127-135
    • /
    • 1994
  • This paper is concerned about a high speed electromagnet of Pressure control solenoid valve. Solenoid valve is controlled by means of Pulse width modulation. The magnetostatic field problem on a solenoid is numerically solved by the 2-D axisymmetric finite element method. And permeance method is adopted for analysing the static and dynamic property of solenoid part theoretically. In addition, in this study, experiments on solenoid part were performed in order to measure the magnetic force and plunger displacement. The numerical results coincided with the experimental results. As a result, the magnetic force has the linear relation with displacement of plunger and the primary factors on the performance of PWM type high speed electromagnet are coil resistance, plunger mass, and the length of air gap between plunger and core.

  • PDF

c-axis Transport Properties of $SmFeAsO_{0.85}$ Single Crystals ($SmFeAsO_{0.85}$ 단결정의 c-축 전도 특성)

  • Park, Jae-Hyun;Doh, Yong-Joo;Lee, Hyun-Sook;Cho, B.K.;Lee, Hu-Jong
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.118-122
    • /
    • 2010
  • Electrical transport properties were measured on $SmFeAsO_{0.85}$ single crystals along the c-axis for various temperatures and magnetic fields. For the measurements a mesa structure was fabricated on the surface of the single crystals. Samples showed a metallic temperature dependence of resistance and current-voltage curves without hysteretic multiple branch splitting that is usually observed in tunneling Josephson junctions. In addition, in ab-planar magnetic fields, samples did not show the Fraunhofer-type field modulation of the critical current. All these features indicate that the c-axis transport characteristics of $SmFeAsO_{0.85}$ single crystals are explained by the anisotropic bulk superconductivity rather than Josephson tunneling.

A Study on the Current Sensor Using an Optical Modulator with BSO (BSO와 ZnSe를 광 변조기로 이용한 전류센서에 관한 연구)

  • 김요희;이대영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.9
    • /
    • pp.721-728
    • /
    • 1991
  • In this paper, a magneto-optic modulator has been designed by using single crystal BSO and polycrystal ZnSe as Faraday cells. And practical core-type optical current sensors using pure iron and permalloy have been prepared and experimented. In order to obtain efficient magnetic field detection, LED(NEC OD08358, 0.87 $\mu$m) was used as optical source, PIN-PD(OD-8454)as optical receiver and multi-mode optical fiber (100/140$\mu$m) as transmission line. The characteristics matrix of the optical element was calculated by Stokes parameter, and optic modulation characteristics equations were derived by Muller matrix. Electromagnetic analysis program (FLUX 2D, micro VAX 3600) by finite element method was used to find the magnetic flux density around the core. The measuring error of the output voltage to input current has been masured below 5% in the range of 50A to 1000A. As the temperature was changed from -20$^{\circ}C$ to 60$^{\circ}C$, the maximum measurement error of the optical output has been found to be 0.5% at 60$^{\circ}C$. These experimental results show good temperature and linearity characteristics. The SNR of the overall system was 47dB in case of 600A (250.2 Oe) conductor current and the system has good noise immunity.

  • PDF

Novel Interface-engineered Junction Technology for Digital Circuit Applications

  • Yoshida, J.;Katsuno, H.;Inoue, S.;Nagano, T.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.1-4
    • /
    • 2001
  • Interface-engineered junctions with $YbBa_2$$Cu_3$$O_{7}$ as the counter electrode were demonstrated. The junctions exhibited excellent Josephson characteristics with a Josephson critical current ($I_{c}$) ranging from 0.1 mA to 8 mA and a magnetic field modulation of the $I_{c}$ exceeding 80% at 4.2 K while maintaining complete c-axis orientation of the counter-electrode layer. The$ 1\sigma$ spreads in $I_{c}$ for junctions with an average $I_{c}$ of 1-2 mA were 5-8% for 16 junctions within a chip, and 9.3% for a 100-junction array. Our dI/dV measurements suggest that a theoretical approach taking into account both a highly transparent barrier and the proximity effect is required to fully understand the Junction characteristics.ristics.

  • PDF

A Review of Assistive Listening Device and Digital Wireless Technology for Hearing Instruments

  • Kim, Jin Sook;Kim, Chun Hyeok
    • Korean Journal of Audiology
    • /
    • v.18 no.3
    • /
    • pp.105-111
    • /
    • 2014
  • Assistive listening devices (ALDs) refer to various types of amplification equipment designed to improve the communication of individuals with hard of hearing to enhance the accessibility to speech signal when individual hearing instruments are not sufficient. There are many types of ALDs to overcome a triangle of speech to noise ratio (SNR) problems, noise, distance, and reverberation. ALDs vary in their internal electronic mechanisms ranging from simple hard-wire microphone-amplifier units to more sophisticated broadcasting systems. They usually use microphones to capture an audio source and broadcast it wirelessly over a frequency modulation (FM), infra-red, induction loop, or other transmission techniques. The seven types of ALDs are introduced including hardwire devices, FM sound system, infra-red sound system, induction loop system, telephone listening devices, television, and alert/alarm system. Further development of digital wireless technology in hearing instruments will make possible direct communication with ALDs without any accessories in the near future. There are two technology solutions for digital wireless hearing instruments improving SNR and convenience. One is near-field magnetic induction combined with Bluetooth radio frequency (RF) transmission or proprietary RF transmission and the other is proprietary RF transmission alone. Recently launched digital wireless hearing aid applying this new technology can communicate from the hearing instrument to personal computer, phones, Wi-Fi, alert systems, and ALDs via iPhone, iPad, and iPod. However, it comes with its own iOS application offering a range of features but there is no option for Android users as of this moment.

Optimize KNN Algorithm for Cerebrospinal Fluid Cell Diseases

  • Soobia Saeed;Afnizanfaizal Abdullah;NZ Jhanjhi
    • International Journal of Computer Science & Network Security
    • /
    • v.24 no.2
    • /
    • pp.43-52
    • /
    • 2024
  • Medical imaginings assume a important part in the analysis of tumors and cerebrospinal fluid (CSF) leak. Magnetic resonance imaging (MRI) is an image segmentation technology, which shows an angular sectional perspective of the body which provides convenience to medical specialists to examine the patients. The images generated by MRI are detailed, which enable medical specialists to identify affected areas to help them diagnose disease. MRI imaging is usually a basic part of diagnostic and treatment. In this research, we propose new techniques using the 4D-MRI image segmentation process to detect the brain tumor in the skull. We identify the issues related to the quality of cerebrum disease images or CSF leakage (discover fluid inside the brain). The aim of this research is to construct a framework that can identify cancer-damaged areas to be isolated from non-tumor. We use 4D image light field segmentation, which is followed by MATLAB modeling techniques, and measure the size of brain-damaged cells deep inside CSF. Data is usually collected from the support vector machine (SVM) tool using MATLAB's included K-Nearest Neighbor (KNN) algorithm. We propose a 4D light field tool (LFT) modulation method that can be used for the light editing field application. Depending on the input of the user, an objective evaluation of each ray is evaluated using the KNN to maintain the 4D frequency (redundancy). These light fields' approaches can help increase the efficiency of device segmentation and light field composite pipeline editing, as they minimize boundary artefacts.

Design of a CMOS RFID Transponder IC Using a New Damping Circuit (새로운 감폭회로를 사용한 CMOS RFID 트랜스폰더 IC 설계)

  • O, Won-Seok;Lee, Sang-Hun;Lee, Gang-Myeong;Park, Jong-Tae;Yu, Jong-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.211-219
    • /
    • 2001
  • This paper describes a read-only CMOS transponder IC for RFID applications. A full-wave rectifier implemented using NMOS transistors supplies the transponder with a dc supply voltage using the magnetic field generated from a reader. A 64-bit ROM has been designed for a data memory. Front-end impedance modulation and Manchester coding are used for transmitting the data from the transponder memory to the reader. A new damping circuit which has almost constant damping rate under the variations of the distance between the transponder and the reader has been employed for impedance modulation. The designed circuit has been fabricated using a 0.65${\mu}{\textrm}{m}$2-poly, 2-metal CMOS process. Die area is 0.9mm$\times$0.4mm. Measurement results show that it has a constant damping rate of around 20~25% and a data transmission rate of 3.9kbps at a 125KHz RF carrier. The power required for reading operation is about 100㎼. The measured reading distance is around 7cm.

  • PDF