A study on the changes in attractive force of magnetic attachments for overdenture

  • Leem, Han-Wool;Cho, In-Ho;Lee, Jong-Hyuk;Choi, Yu-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.9-15
    • /
    • 2016
  • PURPOSE. Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients. MATERIALS AND METHODS. Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet. RESULTS. Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly. CONCLUSION. Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.

Effects of type of magnet attachment and implant angulation in two implant overdenture models

  • Song, So-Yeon;Kang, Kyeong-Hwan;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.1
    • /
    • pp.33-37
    • /
    • 2020
  • PURPOSE. The purpose of this study is to evaluate the effects of type of magnet attachment and implant angulation in two implant overdenture models. MATERIALS AND METHODS. Magnet attachments used in this study were flat and dome types (MGT5515, MGT5520D, Dentium Co., Seoul, Korea). Two implants with keepers were inserted in the resin blocks at a distance of 24 mm. For the first model, the implants were parallel to the vertical and perpendicular to the horizontal; for the second model, both were angulated 5 degrees to the mesial; for the third model, both were angulated 10 degrees toward the mesial. The retentive force was measured in both vertical and lateral directions. Statistical analyses were performed using SPSS software version 22.0 (α=.05). RESULTS. The flat type magnet attachment showed the highest lateral retentive force in the 20° divergent group (P<.05) and the dome type magnet attachment showed the highest lateral retentive force in the parallel group (P<.05). The vertical and lateral retentive force of the dome type magnet attachment was greater than that of the flat type magnet attachment in every direction (P<.05). CONCLUSION. Within the limitations of this study, the dome shape magnet attachment can resist vertical and lateral retentive force more superiorly than the flat type magnet attachment, regardless of angle, in the mandibular two implant model.

A STUDY ON THE PHYSICAL PROPERTIES AND BIOLOGICAL CHARACTERISTICS OF DENTAL MAGNETIC ATTACHMENTS (치과용 자석부착장치의 물리적, 생물학적 특성에 관한 연구)

  • Lim, Yong-Sik;Kim, Yung-Soo;Kim, Chang-Whe;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.1-22
    • /
    • 1999
  • In order to investigate various physical and biological properties of dental magnetic attachments studies on retentive characteristics, corrosion properties, cytotoxicity of different magnetic systems for dental applications were done. For the study of retentive characteristics changes of retentive force by increasing air gap, wear properties of various attachment systems and loss of magnetic force by heat treatment were measured. Forte study of corrosion property of magnet covering metal electrochemical corrosion was done in artificial saliva and 0.9% NaCl solution between $-1,000mV_{SCE}\;and\;+1,000mV_{SCE}$. Anodic polarization curves are obtained about 6 types of samples and 2 types of solution. Corroded surfaces were examined with metallurgical microscope, scanning electron microscope and surface profilometer. For the study of cytotoxicity of magnetic attachment and its field cell growth and agar overlay test were done. The results of this study were as follows. 1. In Magnetic attachments using closed circuit retentive force at zero air gap was greater than magnets using open circuit, but decrease of retentive force by increasing air gap was also greater than open systems. 2. After 40,000 cycles of wear test all mechanical attachment resulted in varing degree of retention loss but in magnetic attachments no loss of retentive force was observed. 3. The magnetic attachment using Neodymium magnet showed early loss of retentive force about $200^{\circ}C$ but attachment using Samarium magnet showed some resistance to heat treatment and complete retention loss was observed about $500^{\circ}C$. The keeper was not influenced by heat treatment in retention. 4. In electrochemical corrosion test Dyna magnetic attachment covering metal showed the highiest corrosion resistance and Shiner magnet covering metal showed the least corrosion resistance and examination of corroded surface with metallurgical microscope, scanning electron micro-scope and surface profilometer also showed same results with anodic polarization corves. 5. The result of cell culture tests on the magnet covered with metal showed least recognizable cytotoxicity.

  • PDF

THE ELECTROCHEMICAL STUDY ON CORROSION RESISTANCE OF VARIOUS DENIAL MAGNETIC ATTACHMENTS (수종 치과용 자석유지장치의 부식저항성에 대한 전기화학적 연구)

  • Sohn Byoung-Sup;Chang Ik-Tae;Heo Seong-Joo;Keak Jai-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.4
    • /
    • pp.336-350
    • /
    • 2001
  • The purpose of this study was to investigate corrosion tendency and to compare corrosion resistance of three dental magnetic attachments and its keeper alloy by coercive, electrochemical method. By using petentiodynamic polarization technique, magnetic elements and its keeper alloy of Magfit EX600 system(MF, MFK), Dyna ES regular system(DN, DNK) and Shiner SR magnet system(SR, SRK) were corroded electrochemically in 0.9% NaCl electrolytic solution. Open-circuit potential and anodic polarization curve was measured with Potentiostat(model 273 EG&E) and polarization curve was created by current density per square area following scanning of increased series of voltage in the rate of 1.0mV per second. Before and after electrochemical corrosion, the surface roughness test was done. Thereafter the change of mean surface roughness value(Ra) and mean peak value(Rt) of surface roughness was compared one another. In order to observe the corroded surface of each specimen, metallurgical light microscopic(${\times}37.5$) and scanning electron microscopic view(SEM ${\times}100$) was taken and compared one another. Conclusion is followings. 1. All of six covering metal of dental magnetic attachments and its keeper alloy were corroded in various degree after electrochemical corrosion. 2. The corrosion resistance of which used in this experiment is the following in high order; DNK, MFK, DN, MF, SRK and SR. 3. Especially Shiner magnet system and its keeper alloy were more severely corroded after electrochemical corrosion and the change of Ra Rt value were more increased than others. 4 Metallurgical and scanning electron microscopic view showed the pitting corrosion tendency of all experimental alloy but DNK and SR. 5. Covering metal of magnet was more corroded than its keeper alloy.

  • PDF

Attachment systems for mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Lee, Jeong-Yol;Shin, Sang-Wan;Bryant, S. Ross
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.197-203
    • /
    • 2012
  • PURPOSE. The aim of this systematic review was to address treatment outcome according to attachment systems for mandibular implant overdentures in terms of implant survival rate, prosthetic maintenance and complications, and patient satisfaction. MATERIALS AND METHODS. A systematic literature search was conducted using PubMed and hand searching of relevant journals considering inclusion and exclusion criteria. Clinical trial studies on mandibular implant overdentures until August, 2010 were selected if more than one type of overdenture attachment was reported. Twenty four studies from 1098 studies were finally included and the data on implant survival rate, prosthetic maintenance and complications, patient satisfaction were analyzed relative to attachment systems. RESULTS. Four studies presented implant survival rates (95.8 - 97.5% for bar, 96.2 - 100% for ball, 91.7% for magnet) according to attachment system. Ten other studies presented an implant survival rate ranging from 93.3% to 100% without respect to the attachment groups. Common prosthetic maintenance and complications were replacement of an assay for magnet attachments, and activation of a matrix or clip for ball or bar attachments. Prosthetic maintenance and complications most commonly occurred in the magnet groups. Conflicting findings were found on the rate of prosthetic maintenance and complications comparing ball and bar attachments. Most studies showed no significant differences in patient satisfaction depending upon attachment systems. CONCLUSION. The implant survival rate of mandibular overdentures seemed to be high regardless attachment systems. The prosthetic maintenance and complications may be influenced by attachment systems. However patient satisfaction may be independent of the attachment system.

Effects of overdenture attachment systems with different working principles on stress transmission: A three-dimensional finite element study

  • Turker, Nurullah;Buyukkaplan, Ulviye Sebnem
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.351-360
    • /
    • 2020
  • PURPOSE. The aim of the present study was to compare the stress distributions on the dental implants, abutments, and bone caused by different overdenture attachment types under functional chewing forces. MATERIALS AND METHODS. The 3D finite element models of the mandible, dental implants, attachment types, and prostheses were prepared. In accordance with a conventional dental implant supported overdenture design, the dental implants were positioned at the bone level in the canine teeth region bilaterally. A total of eight models using eight different attachment systems were used in this study. All the models were loaded to simulate chewing forces generated during the centric relationship (450 N), lateral movement (400 N), protrusive movement (400 N), and also in the presence of a food mass unilaterally (200 N). Stress outputs were obtained as the maximum principal stress and the equivalent von-Mises stress. RESULTS. In all attachment types, higher stress values were observed in the abutments, dental implants, and bone in the magnet attachments in different loading conditions. The highest stress values were observed among the magnet systems in the components of the Titanmagnetics model in all loading conditions (stresses were 15.4, 17.7, and 33.1 MPa on abutment, dental implant, and bone, respectively). The lowest stress value was observed in the models of Zest and O-Ring attachments. CONCLUSION. The results of the present study implied that attachment types permitting rotation and tolerating various angles created lower stresses on the bone, dental implants, and abutments.

MAGNETIC OVERDENTURE

  • Hwang, Jung-Won;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.5
    • /
    • pp.748-757
    • /
    • 1998
  • The stability and retention of mandibular complete denture have been a continuing problem for dentists and patients. Magnets have been investigated or used in clinical dentistry as retentive aids. The obvious advantages are that these attachments do not need spacial equipments or require frequent adjustment of replacement with use, and they likely transmit less lateral forces to the abutment. This articles discusses the scientific background and clinical application of high potency magnetic alloys in overdenture

  • PDF

REHABILITATION OF A PATIENT WITH A POST RADIOTHERAPY TRISMUS WITH AN OBTURATOR AND A MAXILLARY DENTURE USING MAGNET ATTACHMENTS

  • Bae, Hanna-Eun-Kyong;Jeon, Jeong-Ho;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.586-590
    • /
    • 2008
  • Construction of an obturator for rehabilitation of a patient who underwent a maxillectomy is vital. Routinely a constructed obturator includes denture portion. A patient who may present anatomical limitations due to surgical or radiotherapy complications often challenges the clinician. Purpose: This clinical report describes a patient with severe trismus after surgical resection and radiotherapy treatment of a tumor in the upper left maxilla. Conclusion: This report describes the concepts of using a rotational path insertion for an obturator and a separately constructed maxillary denture. The stability and retention of the obturator were obtained from anatomical features. Where as these were achieved through magnetic attachments and the remaining edentulous ridge to ensure esthetic and function of the prosthesis.

Magnet retained intraoral-extra oral combination prosthesis: a case report

  • Banerjee, Saurav;Kumar, Surender;Bera, Amit;Gupta, Tapas;Banerjee, Ardhendu
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.235-238
    • /
    • 2012
  • Facial prosthesis is generally considered over surgical reconstruction to restore function and appearance in patients with facial defects that resulted from cancer resection. Retention of the prosthesis is challenging due to its size and weight. Retention can be achieved by using medical grade adhesives, resilient attachments, clips and osseointegrated implants. It can also be connected to obturator by magnets. This clinical report highlights the rehabilitation of a lateral midfacial defect with a two piece prosthesis that included an extra oral facial prosthesis and an intraoral obturator with the use of magnets.

NOVEL TREATMENT MODALITY OF IMPLANT-RETAINED OVERDENTURE FOR IMMEDIATE FUNCTION IN COMPLETELY EDENTULOUS PATIENTS (무치악 환자에서 하악 임플랜트 지지 피개의치에 의한 즉시 하중 부담에 관한 연구)

  • Kim, Jang-Wook;Kim, Hyeong-Seob;Baik, Jin;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.34-47
    • /
    • 2007
  • Statement of problem: Conventional mandibular complete denture lacks in support and stability for edentulous patients to use. Purpose: To enhance support and stability of mandibular complete denture, 2 implants were inserted on the inter-mental foramina space of edentulous patients. With 2 magnetic attachments on the inner side of the overdenture, we gave immediate loads and evaluated the stability of the implants, the responses of the supporting tissues, and the satisfaction of the patients. Material & methods: 6 edentulous patients (5 male, 1 female) each recieved 2 SLA implants in the inter-mental foramina region and implants were immediately loaded with overdenture with magnet attachments. To evaluate the implants stability and the peri-implant tissues, clinical exams, RFA tests and radiographic exams were preformed at the 1 week, 2wks, 6wks, 12wks, and 24wks. post- surgery. Results: The mean surgery time was $45.7{\pm}7.7mins$., while the denture delivery time was $45.5{\pm}12.6mins$. Only 2 of 14 implants were failed. Survived implants that remained were clincally and radiographically stable. Mean ISQ values were relatively stable, showing $69.71{\pm}5.55$, $69.00{\pm}9.48$, $67.92{\pm}7.86$, $67.92{\pm}9.58$, $70.08{\pm}7.61$, $71.92{\pm}6.43$ at the 1 wk, 2 wks, 6 wks, 12 wks, 24 wks. follow up check. Crestal bone changes were $-1.18mm{\pm}0.68mm$, $-1.35{\pm}0.69mm$, $-1.47{\pm}0.68mm$ at the 6wks, 12wks, 24wks. follow up check. Bleeding on probing(BOP index) was not significant. Conclusion: Mandibular ovedentures with 2 magnetic attachments over two interforaminal implants on edentulous patients for immediate function is a recommendable novel treatment for edentulous patients which shows stability on the implants and supporting tissue.