• 제목/요약/키워드: Machine equipment

검색결과 867건 처리시간 0.028초

A Study on Development of Machine-readable Platform for S-100 ECDIS

  • CHOI, HyunSoo;KANG, DongWoo;OH, SeWoong;KIM, YunJee
    • 한국항해항만학회지
    • /
    • 제45권2호
    • /
    • pp.61-68
    • /
    • 2021
  • Logistics movement using ships has been used for many centuries, but maritime accidents are still difficult to predict and they occur on a large scale. The International Maritime Organization (IMO) made it mandatory to install Electronic Chart Display and Information System (ECDIS) for safe seas, but S-57 standards applied to equipment were not updated over 30 years. In addition, it is difficult to keep the equipment up-to-date and revise standards as ships move around the world. In consideration of the limitations of S-57, the IHO developed the new standard as S-100 rather than an update of the S-57. In this study, the previously developed S-100 tool and S/W were configured as one platform and applied to the S-100 ECDIS. The platform conducts as the S-100 cycle and ecosystem from the creation of standards to release and practical use in ships. The hydrographic information standard is machine-readable as defined in S-100, and it has been validated that the latest standard can be applied using the Plug and Play (PnP) function without software system updates. It is expected that international organization such as the International Hydrographic Office (IHO) and the International Association of Marine Aids to Navigation and Lighthouse Authorities (IALA) shall develop and release standards and mariners can easily apply the latest standards to equipment through the machine-readable platform.

건설장비 개발과정에서 신뢰성성장관리 적용방법에 대한 연구 (Application of Reliability Growth Management for Construction Equipment Development Process)

  • 소영국;전영록;류병진
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제13권3호
    • /
    • pp.175-190
    • /
    • 2013
  • This study considers reliability growth management as the excellent method for construction equipment development with the effect on decreasing COPQ(Cost of Poor Quality Cost) of new products. MIL-HDBK-189A(1981) and RADC-TR-84-20(1984) standards provide a general concept of reliability growth management including to reliability growth test, models and FRACAS(Failure Reporting and Corrective Action System). There is no study how to apply reliability growth management to construction equipment(or machine) development. This paper propose the method to apply it to construction equipment development process from the reliability target setting for developing products to launching them at market. It is expecially showing how to set target reliability for new developing equipment and the development risk to reach the reliability target in detail.

워블메커니즘을 이용한 인버젼 기구의 개발 (Development of Inversion Machine Using Wabble Mechanism)

  • 김형준
    • 디자인학연구
    • /
    • 제19권6호
    • /
    • pp.5-8
    • /
    • 2006
  • 본 논문은 '거꾸리'라고도 불리는 스트레칭 운동에 이용되는 인버젼 기구의 사용성을 워블메카니즘을 이용하여 효과적으로 개선시킨 가정용 인버젼 기구의 디자인 개발에 관한 것이다. 근래 현대인의 삶에서 건강이 생활의 중심으로 대두되면서 운동을 즐기는 사람들이 늘어났고, 전신 스트레칭이 과다한 업무나 운동의 부작용으로 인한 디스크의 압박 해소에 효과적임이 일반인에게 널리 알려지면서 인버젼 기구의 사용자가 증가하게 되었다. 그러나 기존의 수동 인버젼 기구는 사용자가 테이블의 회전을 위해 무게 중심을 일일이 조정해야 하는 번거로움과 미숙련자들에게는 사용 미숙으로 인해 테이블이 갑자기 회전하는 안전사고 위험 등의 단점이 있었다. 이에 본 연구는 작고 단순한 구조로 큰 감속비를 내며 역전이 방지되는 워블메카니즘을 테이블의 회전 장치와 발목을 고정하는 장치에 도입함으로써 수동 조작 방식에서 자동 방식으로의 개선을 가능하게 하였다. 그 결과, 다양한 신체 조건의 사용자들에게 편리성과 안전성을 높여 주었고, 동력전달 장치 구조의 단순화를 통한 디자인 외부 요소의 단순성을 구현하였다. 이에 가정에서 사용자의 사용이 편리하고 설치 및 보관이 용이한 접이식 가정용 인버젼 기구를 개발하였다.

  • PDF

3차원 입체정위 유방생검술의 정확도 및 정밀도 평가 (Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy)

  • 이미화
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권3호
    • /
    • pp.213-220
    • /
    • 2015
  • 본 연구는 3차원 입체정위 유방생검술의 정확도를 알아보고, 심부침생검을 이용하여 Stereotactic biopsy과 Sonoguided biopsy의 정확도와 정밀도를 평가하고자 한다. Stereotactic QC phantom을 이용하여 실제 5개의 target 위치로 3D sterotactic machine의 정확도를 측정하고, CT장비로 Scan하여 실측을 구해 X, Y, Z의 길이의 정밀도를 비교한다. 유방조직과 유사하게 제작한 Agar power phantom을 이용하여 5개의 각기 다른 needle tip Target을 통해 3D sterotactic machine과 2D ultrasound machine의 정확도를 비교하고, Z축을 장비별로 실측하여 정밀도와 신뢰도를 비교하며, 6개의 모조병소 Target을 심어놓은 Medical application phantom으로 표적하여 육안검사와 Specimen검사를 통해 정확도를 확인하였다. Stereotactic QC phantom으로 측정한 3D sterotactic machine의 정확도는 100%였으며, CT와 비교한 정밀도는 X, Y, Z축이 모두 p>0.05로 나타났다. Agar powder phantom으로 측정한 두 장비의 정확도는 100%의 정확도를 보였으며, CT와 두 장비 사이에는 p > 0.05로 차이가 없었다. 그러나 2명의 방사선사가 측정한 신뢰도분석에서 3D sterotactic machine은 ICC가 0.954였고, 2D ultrasound machine은 0.785로 2D ultrasound machine이 술자에 따라 차이가 있었다. Medical application phantom의 실험에서 3D sterotactic machine은 Sliced boneless ham을, 2D ultrasound machine은 small chalk powder group를 찾을 수 없었다. Phantom을 이용한 3차원 입체정위 유방생검술의 정확성은 우수하게 나타났고, 인체조직과 비슷한 Agar powder phantom과 유방 조직과 비슷한 Medical application phantom을 이용하여 Stereotactic biopsy과 Sonoguided biopsy의 정확도와 정밀도 모두 우수하게 나타났다. 또한 Medical application phantom의 심부침생검의 정확성 평가에서 각 검사에 따라 생검 표본이 병소의 형태에 따라 상이하게 채취되었고, 3차원 입체정위 유방생검술의 재현성이 유방 초음파검사보다 술자의 영향없이 우수하였다.

Tipless 방식에 의한 디스플레이 고진공 배기 밀봉장치 개발에관한 공정개발연구 (The manufacturing Process Improvement usung Display of high VacuumExhausted Sealing Equipment by Tipless Manner)

  • 김수용;박승곤;정원채
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.817-820
    • /
    • 2001
  • This machine is a high-vacuum exhaust sealing device which makes the inside of PDP element in high vacuum state, blows inactive gases into it and finally seals it. This machine consists of vacuuming parts, heating parts and exhausting parts. Applying the energy saving technology, this machine improves the temperature uniformity of vacuuming and heating parts.

  • PDF

고진공배기 시스템 장치개발에 관한연구 (The manufacturing Improvement of high VacuumExhausted Sealing Equipment)

  • 김수용;이오걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1795-1797
    • /
    • 2001
  • This machine is a high-vacuum exhaust sealing device which makes the inside of PDP element in high vacuum state, blows inactive gases into it and finally seals it. This machine consists of vacuuming parts, heating parts and exhausting parts. Applying the energy saving technology, this machine improves the temperature uniformity of vacuuming and heating parts.

  • PDF

Simplified Machine Diagnosis Techniques Using ARMA Model of Absolute Deterioration Factor with Weight

  • Takeyasu, Kazuhiro;Ishii, Yasuo
    • Industrial Engineering and Management Systems
    • /
    • 제8권4호
    • /
    • pp.247-256
    • /
    • 2009
  • In mass production industries such as steel making that have large equipment, sudden stops of production process due to machine failure can cause severe problems. To prevent such situations, machine diagnosis techniques play important roles. Many methods have been developed focusing on this subject. In this paper, we propose a method for the early detection of the failure on rotating machine, which is the most common theme in the machine failure detection field. A simplified method of calculating autocorrelation function is introduced and is utilized for ARMA model identification. Furthermore, an absolute deterioration factor such as Bicoherence is introduced. Machine diagnosis can be executed by this simplified calculation method of system parameter distance with weight. Proposed method proved to be a practical index for machine diagnosis by numerical examples.

콘크리트 층진 베드를 적용한 초정밀 무심 연삭기의 구조 해석 (Structural Characteristic Analysis of a High-Precision Centerless Grinding Machine with Concrete-Filled Bed)

  • 김석일;조재완
    • 한국정밀공학회지
    • /
    • 제22권2호
    • /
    • pp.172-179
    • /
    • 2005
  • A high-precision centerless grinding machine has been recognized as a core equipment performing the finish outer-diameter grinding process of ferrules which are widely used as fiber optic connectors. In this study, in order to realize the high-precision centerless grinding machine, the structural characteristic analysis and evaluation are carried out on the virtual prototype consisted of the steel bed, hydrostatic GW and RW spindle systems, hydrostatic RW feed mechanism, RW swivel mechanism, and on-machine GW and RW dressers. The loop stiffnesses of centerless grinding machine are estimated based on the relative deformations between GW and RW caused by the grinding forces. And the simulated results illustrate that the concrete-filled bed has the considerable effect on the improvement of the structural stiffness of centerless grinding machine.

Methods to Reduce Greenhouse Gas for University Buildings to Make a Low-Carbon Green Campus - With Case Study on the 'E' University -

  • Song, Su Min;Peom, Sung Woo;Park, Hyo Soon;Song, Kyoo Dong
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.37-46
    • /
    • 2014
  • University buildings are energy-guzzling facility that consume more than 10,000TOE within a campus annually. Even the consumption is on an upswing trend. Behind such high consumption are there cheap power rates for education facility, lack of high-efficiency equipment and ever-increasing use of various information equipment. Being keenly aware that greenhouse gas emission increases due to such rise of energy consumption, the present study carried out a case study. In the case study, the study chose the buildings of E university from top 10 universities that consume energy most in Seoul and examined the current status of their energy consumption and greenhouse gas emission. And then it set the reduction target of greenhouse gas by year. Putting aside a middle and long-termed strategy for later endeavor, it first established the 1st year's implementation plan (2014) for energy saving and greenhouse gas reduction with limited budget and according to greenhouse gas reduction target. The plan is specified as follows. Targets for energy saving are mainly divided into two sectors: machine equipment and electric equipment. 7 ideas were proposed. Three ideas to improve machine equipment are to replace with high-efficiency boilers and chillers and to adjust the position of the cooling tower. By doing so, it was estimated that energy could be saved by 176.34TOE in total and greenhouse gas could be reduced by 370.771t$CO_2$-eq. Four ideas to improve electric equipment include the replacement with LED lights, LED emergency lights and high-efficiency motors and the installation of motion sensors. It was calculated that such replacement could conserve 1,076.08TOE (electric energy) and reduce 2,181.420t$CO_2$-eq (greenhouse gas).