• Title/Summary/Keyword: MW

Search Result 2,514, Processing Time 0.03 seconds

The Effect of Strong Acid and Ionic Material Addition in the Microwave-assisted Solubilization of Waste Activated Sludge (Microwave를 이용한 폐활성슬러지의 가용화 반응에서 강산과 이온성 물질의 첨가가 미치는 영향)

  • Lee, Jeongmin;Lee, Jaeho;Lim, Jisung;Kim, Youngwoo;Byun, Imgyu;Park, Taejoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.1
    • /
    • pp.60-68
    • /
    • 2015
  • The study of waste activated sludge (WAS) solubilization has been increased for sludge volume reduction and enhancing the efficiency of anaerobic digestion. Microwave (MW)-assisted solubilization is an effective method for the solubilization of WAS because this method can lead to thermal, nonthermal effect and ionic conduction by dielectric heating. In this study, the solubilization of WAS by MW heating and conductive heating (CH) was compared and to enhance the MW-assisted solubilization of WAS at low MW output power, chemical agents were applied such as $H_2SO_4$ as the strong acid and $CaCl_2$, NaCl as the ionic materials. Compared to the COD solubilization of WAS by CH, that by MW heating was approximately 1.4, 6.2 times higher at $50^{\circ}C$, $100^{\circ}C$, respectively and the highest COD solubilization of WAS was 10.0% in this study of low MW output power condition. At the same MW output power and reaction time in chemically agents assisted experiments, the COD solubilization of WAS were increased up to 18.1% and 12.7% with the addition of $H_2SO_4$ and NaCl, however, that with the addition of $CaCl_2$ was 10.7%. This result might be due to the fact that the precipitation reaction occurred by calcium ion ($Ca^{2+}$) and phosphate ion (${PO_4}^{3-}$) produced in WAS after MW-assisted solubilization. In this study, $H_2SO_4$ turned out to be the optimal agent for the enhancement of MW efficiency, the addition of 0.2 M $H_2SO_4$ was the most effective condition for MW-assisted WAS solubilization.

Genetic and Phenotypic Parameter Estimates of Body Weight at Different Ages and Yearling Fleece Weight in Markhoz Goats

  • Rashidi, A.;Sheikahmadi, M.;Rostamzadeh, J.;Shrestha, J.N.B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.10
    • /
    • pp.1395-1403
    • /
    • 2008
  • The objective of the present study was to estimate genetic parameters for economic traits in Markhoz goats. Data collected from 1993 to 2006 by the Markhoz goat Performance Testing Station in Sanandaj, Iran, were analyzed. The traits recorded as body weight performance at birth (BW), weaning (WW), six month (6MW), nine month (9MW), yearling (YW) and yearling fleece weight (YFW) were investigated. Least square analyses were used for estimation of environmental effects. Genetic parameters were estimated with single and multi trait analysis using restricted maximum likelihood (REML) procedures, under animal models. By ignoring or including maternal additive genetic effects and maternal permanent environmental effects, five different models were fitted for each trait. The effects of sex, type of birth, age of dam and year of birth on the all body weights were significant (p<0.01), but had no effects on YFW except year of birth. Age of kids had significant influences on WW and 6MW (p<0.01). A log likelihood ratio test was carried out for choosing the most suitable model for each trait. Total heritability estimates for YFW and growth traits varied from 0.16 for YFW and WW to 0.41 for YW. For all traits, maternal heritability was lower than direct heritability, ranging from 0.06 for BW to 0.01 for 6MW and 9MW. The magnitude of $c^2$ was more substantial for BW than the others, and relative importance was reduced from 0.12 for BW to 0.04 for 9MW. The direct additive genetic correlations estimates were positive and varied from 0.21 between BW-YW to 0.96 between WW-6MW. Direct additive genetic correlations between YFW and body weight traits were positive and ranged from 0.14 between BW-YFW to 0.67 between 6MW-YFW. For all traits, the corresponding estimates for phenotypic correlation were positive and lower than genetic correlations. The maternal additive genetic correlations between various traits were varied and ranged from -0.19 between 9MW-YFW to 0.96 between 6MW-9MW. The estimates of the maternal permanent environmental correlations between various traits were positive and ranged from 0.33 between WW-YFW to 0.93 between WW-6MW. Also, the environmental correlations between various traits ranged from 0.01 between BW-YFW and WW-YFW to 0.70 between 9MW-YW. Estimates of genetic parameters for various traits in this study confirm that selection should be applied on WW for genetic improvement in Markhoz goats.

A Study on the Algorithm for Interconnection of PV System on Power Distribution System Considering Reliability (신뢰도를 고려한 태양광시스템의 배전계통 연계 알고리즘에 관한 연구)

  • Moon, Jong-Fil
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.4
    • /
    • pp.241-245
    • /
    • 2011
  • In this paper, when photovoltaic (PV) systems are connected to power distribution system, most effective capacity and connected-point of PV system are presented considering power distribution system reliability. The reliability model of PV system is presented considering the duration of sunshine. Also the model of time-varying load and reliability test system bus2 model are used. To simulate the effects of PV system, various cases are selected; (1) base case which is no connection of PV system to power distribution system when faults are occurred, (2) 3MW case which is 3[MW] connection of PV system (3) 4[MW] case, and (4) 20[MW] case which is 20[MW] connection of PV system to the bus of power distribution system. The capacity limit of connected PV system is settled to 14[MW] for all cases except case 4. The reliability for residential, general, industrial, and educational customer is evaluated.

Performance Test of 200-MW Pulse Transformer for 80-MW Klystron Load (80-MW 클라이스트론 부하용 200-MW 펄스 트랜스포머의 성능시험)

  • Jang, S.D.;Oh, J.S.;Son, Y.G.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2167-2169
    • /
    • 1999
  • A pulse transformer producing pulses with the peak power of 200-MW (400 kV 500 A at load side with $4.4{\mu}s$ flat-top) is required to drive the 80-MW pulsed klystron in the PLS linac. We have designed and manufactured the high power pulse transformer with 1 : 17 turn ratio. Its primary functions are to match the impedance of klystron tube to the modulators, and to provide step-up of the voltage. To obtain a fast rise time of the pulse voltage. Low leakage inductance and low distributed capacitance design is very important. In this paper, we discuss the equivalent circuit analysis of the pulse transformer, and present the full power performance test results of pulse transformer.

  • PDF

Effects of Hydrolysis Time on the Molecular Weight Distribution of Alginates Prepared from Sea Tangle Laminaria japonicus

  • Lim Yeong-Seon;You Byeong-Jin
    • Fisheries and Aquatic Sciences
    • /
    • v.8 no.3
    • /
    • pp.113-117
    • /
    • 2005
  • To prepare oligouronic acids from high-molecular-weight alginates, sea tangle Laminaria japonicus alginates were hydrolyzed at $80^{\circ}C$ for various hydrolysis times (HT). The effects of hydrolysis time on the distribution ratios (DR) of the molecular weights (MW) of the hydrolyzed alginates were in-vestigated. As HT increased, the DR of the alginates with MW>500 kDa decreased ex-ponentially, while those with MW=50-100 kDa or MW<50 kDa increased exponentially. For MW=300-500 kDa, DR increased exponentially until HT reached 60 min, and then decreased exponentially. Similarly, for MW=100-300 kDa, DR increased exponentially until HT reached 90 min, and then decreased.

Nutritional Value and Digestibility of Tenebrio molitor As a Feed Ingredient for Rockfish (Sebastes schlegeli) (조피볼락의 사료원으로 갈색거저리의 영양적 가치 및 소화율 평가)

  • JANG, Tae-Ho;JUNG, Sung-Mok;KIM, Esther;LEE, Yong-Seok;LEE, Sang-Min
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.3
    • /
    • pp.888-898
    • /
    • 2017
  • Tenebrio molitor larvae, also known as yellow mealworms (MW), are rich in protein and lipid and can serve as a potential alternative protein and energy source in commercial aquafeeds. Therefore, this study attempts to evaluate the effects of different drying methods on the nutritional value of MW meal. For this, live MW were cold-anaesthetized before being subjected to three different types of drying methods, including freeze-drying, oven-drying at $60^{\circ}C$ and air-drying at room temperature for three days, and compared for proximate composition and energy content. An in-vivo digestibility test was then conducted to evaluate the nutrient digestibility of MW meal in diets for rockfish, Sebastes schlegeli. A test diet was prepared by mixing the MW meal with a reference diet (Ref) in a 30:70 ratio with chromium oxide as an inert marker at the inclusion level of 0.5%. Rockfish with mean body weight of 150 g were stocked into a fecal collection system equipped with fiberglass tanks of 400 L capacity. Each group of fish was fed one of the experimental diets to apparent satiation for 4 weeks. The results of the proximate analysis showed that drying methods had no significant effect on crude protein, crude lipid, ash and energy contents of MW. Despite being a rich source of protein and lipid, MW meal was deficient in certain amino acids, particularly methionine, and highly unsaturated fatty acids, particularly 22:6n-3 (DHA) and 20:5n-3 (EPA). MW meal showed high digestibility values for protein (93%), lipid (97%) and energy (88%). These results may indicate that MW meal is a nutritious and acceptable feed ingredient, with comparable digestibility values to conventional animal and plant feedstuffs such as fish meal and soybean meal, in practical diet for rockfish at grower stage.

Construction of Plasmids for Overproduction of L-Phenylalanine (L-페닐알라닌 대량생산을 위한 재조합 플라스미드 구성)

  • Lee, Sae-Bae;Park, Chung;Won, Chan-Hee;Choi, Duk-Ho;Lim, Bun-San
    • Korean Journal of Microbiology
    • /
    • v.28 no.2
    • /
    • pp.169-173
    • /
    • 1990
  • For the overproduction of L-phenylalanine using Escherichia coli, the authors constructed various recombinant plasmids including pMW 10, pMW 11 and pMW 12. The $aroF{FR}$ and $pheA^{FR}$ genes for the production of L-phenylalanine were isolated from Escherichia coli MWEC 101-5 strains. The productivity and atability of Escherichia coli regulatory mutants containing recombinant plasmids were investigated to evaluate the efficiency of the $aroF^{FR}$ and $pheA^{FR}$ genes. The MWEC 101-5/pMW 11 strain produced 24.3g/l of L-phenylalanine while its stability was 73.8 percent. The specific activity of prephenate dehydratase in the MWEC 101-5/pMW 11 strain increased by 26-fold compared with that of Escherichia coli K-12.

  • PDF

Development and Demonstration of Trial-run Automation System of Energy Storage System for Frequency Regulation (주파수조정용 에너지저장장치 시운전 자동화 시스템의 개발과 실증)

  • Lim, Geon-Pyo;Choi, Yo-Han;Lee, Seung-Min;Park, Chan-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.110-116
    • /
    • 2017
  • System to automate the trial-run of energy storage system for frequency regulation was developed and demonstrated. Basic strategy was developed on the basis of trial-run procedure and verified in the computer simulation tool. The algorithm was developed and coded for 4MW trial-run automation system. 4MW trial-run automation system was connected to 4MW energy storage system for frequency regulation in Jocheon substation of Jeju city and demonstrated. 24MW trial-run automation system was developed on the basis of 4MW trial-run automation system and verified by operation system for 24MW energy storage system for frequency regulation. The operation system has own simulation model of energy storage system and power system. The verification was performed to improve the system in the view of user. 24MW trial-run automation system was demonstrated in 32MW Ul-san and 36MW Non-gong energy storage system. All tests of trial-run was done by manual and first they ware taken 1 week with no trial-run automation system. The manual trial-run tests were taken by maximum three times. Trial-run test by trial-run automation system was taken 2 days. The system helps reduce the trial-run test period and improve the accuracy of tests.

Preliminary Economic Analysis of 20 MW Super-Capacity Wind Turbine Generator in the East Sea of Korea (국내 동해지역 20 MW급 초대용량 풍력발전시스템 사전 경제성 분석)

  • Jun-Young Lee;Seo-Yoon Choi;Rae-Hyoung Yuck;Kwang-Tae Ha;Jae-ho Jeong
    • Journal of Wind Energy
    • /
    • v.13 no.4
    • /
    • pp.50-57
    • /
    • 2022
  • Renewable energy is emerging as a way for the government to carry out its 2030 carbon-neutral policy. In this regard, the demand for wind turbine generators for renewable energy is increasing. As a result of restrictions due to civil complaints, offshore wind power generators are actively being developed. At this time, offshore wind power generation has higher maintenance costs, material costs, and installation costs compared to onshore wind power generation. So, an economic evaluation that calculates imports and costs is an important task. The levelized cost of energy (LCOE) is an economic evaluation index used in the energy field. In this paper, based on AEP calculated by windpro, the LCOE calculated by the wind power cost estimation model published in the NREL Economic Analysis Report, installing one 15 MW unit and installing one 20 MW unit and seven units were reviewed and analyzed. As a result, AEP was calculated as 0.140($/Kwh) for the installation of a single 15 MW, 0.142($/Kwh) for the installation of a single 20 MW, and 0.119 ($/Kwh) for the installation of a 20 MW farm. Therefore, it was confirmed that the installation of the single 20 MW was more economical than the installation of the single 15 MW and the installation of the 20 MW farm was most economical.

Chest dimension in spontaneous pneumothorax (자연기흉 환자의 흉곽계측)

  • Kim, Jong-Won;Lee, Jong-Su
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.750-759
    • /
    • 1986
  • Spontaneous pneumothorax is usually seen in young adult male. And typically, the patient is a tall, thin, 20- to 30-year-old male. Usually the pneumothorax results from rupture of a pulmonary bleb. Author reviewed 66 cases of spontaneous pneumothorax experienced in the Dept. of Thoracic & Cardiovascular Surgery, Pusan National University Hospital, since Jan., 1980 to Aug., 1986. The clinical data were summarized as follows: 1. The age distribution of spontaneous pneumothorax: 17 to 34 years old and mean age was 25.3 years. 2. The sex distribution of spontaneous pneumothorax: 52 in men, 14 in women and the ratio was 3.7:1. 3. Chest dimension in male patients: Maximum posteroanterior distance [MPA], MPA/Maximum width [MW]: Significantly smaller than control group. Distance from second to tenth rib on left [L2-10], Distance from second rib on right to diaphragm [R2-D], R2-D/MW: Significantly larger than control group. 4. Chest dimension in female patients: MPA, MW: Significantly smaller than control group. Distance from second rib on left to diaphragm [L2-D], Distance from second to tenth rib on right [R2-10], R2-D, L2-10/MW, L2-D/MW, R2-10/MW, R2-D/MW: Significantly larger than control group.

  • PDF