• Title/Summary/Keyword: MVA

Search Result 331, Processing Time 0.037 seconds

Triterpenoid Ginsenoside Biosynthesis in Panax ginseng C. A. Meyer (인삼에서의 트리터페노이드 진세노사이드의 생합성)

  • Kim, Yu-Jin;Lee, Ok-Ran;Yang, Deok-Chun
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.20-20
    • /
    • 2012
  • Isoprenoids represent the most diverse group of metabolites, which are functionally and structurally identified in plant organism to date. Ginsenosides, glycosylated triterpenes, are considered to be the major pharmaceutically active ingredient of ginseng. Its backbones, categorized as protopanaxadiol (PPD), protopanaxatriol (PPT), and oleanane saponin, are synthesized via the isoprenoid pathway by cyclization of 2,3-oxidosqualene mediated with dammarenediol synthase or beta-amyrin synthase. The rate-limiting 3-hydroxy-3-methylglutaryl coenzyme A reductase (HMGR), which is the first committed step enzyme catalyzes the cytoplasmic mevalonate (MVA) pathway for isoprenoid biosynthesis. DXP reductoisomerese (DXR), yields 2-C-methyl-D-erythritol 4-phosphate (MEP), is partly involved in isoprenoid biosynthesis via plastid. Squalene synthase and squalene epoxidase are involved right before the cyclization step. The triterpene backbone then undergoes various modifications, such as oxidation, substitution, and glycosylation. Here we will discuss general biosynthesis pathway for the production of ginsenoside and its modification based on their subcellular biological functions.

  • PDF

Design and Fabrication of 1 MVA Single Phase HTS Transformer for Power Distribution with Natural Convection Cooling System

  • Kim, W. S.;Kim, S. H.;Park, K. D.;H. G. Joo;G. W. Hong;J. H. Han;Park, J. H.;H. S. Son;S. Y. Hahn
    • Progress in Superconductivity
    • /
    • v.5 no.2
    • /
    • pp.149-152
    • /
    • 2004
  • The design and the fabrication of a 1 MVA single-phase HTS transformer are presented in this paper, The rated voltages are 22.9 ㎸ for primary and 6.6 ㎸ for secondary, and the rated currents are 44 A and 152 A respectively. The transformer has HTS double pancake type windings. This type of winding has many advantages such as ease of fabrication and maintenance, good distribution of surge voltage and insulation of windings. Single HTS wire was used for primary winding and four HTS parallel wires were used for secondary winding. These windings are arranged reciprocally with the shell type iron core. An FRP cryostat with room temperature bore was fabricated to isolate the iron core from the coolant. The winding will be cooled down to 65 K with sub-cooled liquid nitrogen using a GM-cryocooler. The sub-cooled liquid nitrogen has advantages of good insulation because of no bubbles as well as increased current capacity of HTS wire.

  • PDF

The study on the DC Ic measurement and AC loss in the 22.9kV, 50MVA HTS power cable (22.9kV/50MVA급 고온초전도 전력케이블의 DC Ic 측정 및 교류손실에 관한 연구)

  • Choi, Suk-Jin;Lee, Sang-Jin;Sim, Ki-Deok;Cho, Jeon-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.808-809
    • /
    • 2008
  • 22.9kV 50MVA HTS power cable has been developed and tested by Korea Electrotechnology Research Institute and LS Cable Company and it was supported by a grant from Center for Applied Superconductivity Technology of the 21st Century Frontier R&D Program. In this paper, DC Ic of 100m HTS cable which is installed at Kochang testing station was measured and analyzed. A measurement technique of DC Ic used by resistance and inductance removal method is established. The HTS power cable is composed of 2 layers for transmission and 1 layer for shield. For the analysis of AC losses in an HTS power cable, 2-dimensional numerical calculation was carried out to define the magnetic field distribution. We calculated the magnetization losses in the HTS core of that cable from these fields. These calculated results are in accordance with those of experiment.

  • PDF

Project Summary of Three Gorges' 840MVA Hydro-generator with Close-Loop-Self-Circulating Evaporative Cooling System

  • Yuan, Jiayi;Meng, Dawei;Gu, Guobiao;Song, Fuchuan;Zhang, Tianpeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.1
    • /
    • pp.48-53
    • /
    • 2014
  • In December 2011 and July 2012, two sets of 840MVA hydro-generator of Three Gorges on Yangtze River with Close-loop-self-circulating evaporative cooling (CLSCEC) system were put into commercial operation. In this paper, we make engineering summary of these two generators with CLSCEC system. We also make a comparison between the internal water cooling (IWC) hydro-generator and the CLSCEC hydro-generator used in Three Gorges power plant in fields of their operating characteristics, working performances, technical features, working safety and reliability. In addition, engineering structures, type tests' results and systematic emulating calculation of CLSCEC schemes are analyzed.

A Study on the High Performance PWM Technique for a Propulsion System of Railway (철도차량용 추진제어장치의 고능률 PWM기법에 관한 연구)

  • Min, Byoung-Gwon;Seo, Kwang-Duk;Won, Chung-Yuen
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.186-192
    • /
    • 1998
  • This paper presents a high performance low switching PWM technique or the propulsion system of railway such as subway and high speed train. In order to achieve the continuous voltage control to six-step and s low harmonics with low switching frequency under 500Hz, the synchronous technique is combined with a space vector overmodulation and implemented by using DSP. Improved performance and a validation of proposed method are showed by the digital simulation and the experimental results using a 1.65MVA IGBT VVVF inverter and inertia load equivalent to 160 tons railway cars.

  • PDF

The Application and Verification of the 2MVA Battery Energy Storage System(BESS) with Wind-turbine in Micro-grid of Gapado, Jeju (가파도 마이크로그리드에서의 풍력발전 연계를 위한 2MVA급 배터리 에너지 저장시스템(BESS) 적용 및 실증)

  • Kim, Seung-Mo;Oh, Seung-Jin;Lee, Jong-Hak;Kim, Tae-Hyeong;Kwon, Byung-Ki;Ahn, Jae-Min;Jin, Kyung-Min;Choi, Chang-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.303-311
    • /
    • 2014
  • This paper shows the test result of 2MVA BESS(Battery Energy Storage System) with wind-turbine in micro-grid of the Gapado. To implement of micro-grid with BESS, characteristics of generator and customer load in grid are considered. Also, to operate of 2-parallel PCU(Power Conversion Unit) in BESS, the droop control is adopted with operating mode of grid independent. Performances of BESS with wind-turbine were verified by analysis of power quality such as voltage harmonics, ratio of voltage and frequency regulation, and by measurement of waveform such as output voltage and current.

Characteristics of Multiply Laminated HTS tapes for the Windings of Large Power Superconducting Transformers (대용량 초전도 변압기 권선용 다중선재의 특성)

  • Kim, W.S.;Lee, S.;Hwang, Y.I.;Chang, T.;Lee, H.G.;Hong, G.W.;Choi, K.D.;Hahn, S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1216-1218
    • /
    • 2005
  • A high temperature superconducting power transformer gets its advantages over the conventional ones when the rated capacity of the HTS transformer becomes 30 MVA or more. The standard capacity of the recent 154 kV/ 22.9 kV power transformer is 3 phase 60 MVA in Korea which means that the rated current of the secondary becomes more than 1,500 amps. Considering the current capacities of the HTS wires being developed recently, it is inevitable to use the HTS wires in parallel in order to be applied to the power transformer. But nonuniform distribution of currents and large AC losses are major problems in parallel HTS windings setting aside the difficulties of making parallel windings. To solve these problems, several kinds of multiply laminated HTS wires were fabricated and tested for the application of these multiple wire to an HTS power transformer. Test results were compared with that of each other and the best were selected for the application to an HTS power transformer.

  • PDF

The Effects of Intellectual Capital and Financial Leverage on Evaluating Market Performance

  • OBEIDAT, Samer;AL-TAMIMI, Khaled;HAJJAT, Emad
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.3
    • /
    • pp.201-208
    • /
    • 2021
  • This study aimed to identify the key factors that affect the financial market performance (Price-Earnings Model) through a sample of 35 public shareholding industrial companies on the Amman Stock Exchange for the period 2010-2019, using statistical models and methods, such as the Simple Linear Regression Model, Correlation Coefficient, and dispersion board. The study results showed the nonexistence of a statistically significant effect between the intellectual capital and market value added (MVA) and market performance. Results also showed a statistically significant positive effect between financial leverage (FL) and the market performance, where the interpreted variation reached 64%. It showed from the analysis results that the relationship between (MVA) and market performance (P/E) agrees with the study hypotheses, while the result related to (FL) disagrees with the study hypotheses. The study recommends that public shareholding industrial companies should focus more on intellectual capital and show its value in the annual financial statements and reports, and those companies that have high profitability and the chance to hold gains and profits should rely less on debt and more on retained earnings, due to the high risk of debt and in line with the present unstable circumstances in Jordan, especially in light of the global Covid-19 crisis.

Characteristics of a 190 kVA Superconducting Fault current Limiting Element (190 kVA급 초전도한류소자의 특성)

  • Ma, Y.H.;Li, Z.Y.;Park, K.B.;Oh, I.S.;Ryu, K.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.37-42
    • /
    • 2007
  • We are developing a 22.9 kV/25 MVA superconducting fault current limiting(SFCL) system for a power distribution network. A Bi-2212 bulk SFCL element, which has the merits of large current capacity and high allowable electric field during fault of the power network, was selected as a candidate for our SFCL system. In this work, we experimentally investigated important characteristics of the 190 kVA Bi-2212 SFCL element in its application to the power grid e.g. DC voltage-current characteristic, AC loss, current limiting characteristic during fault, and so on. Some experimental data related to thermal and electromagnetic behaviors were also compared with the calculated ones based on numerical method. The results show that the total AC loss at rated current of the 22.9 kV/25 MVA SFCL system, consisting of one hundred thirty five 190 kVA SFCL elements, becomes likely 763 W, which is excessively large for commercialization. Numerically calculated temperature of the SFCL element in some sections is in good agreement with the measured one during fault. Local temperature distribution in the190 kVA SFCL element is greatly influenced by non-uniform critical current along the Bi-2212 bulk SFCL element, even if its non-uniformity becomes a few percentages.

Determination of a Substation and Installation Site for applying Superconducting Cable/FCL to Real Power Grid (초전도케이블/한류기 실계통 적용 변전소 및 설치위치 선정 기술검토)

  • Yang, B.M.;Won, Y.J.;Kim, B.H.;Kang, J.W.;Yoon, J.Y.;Lee, S.R.;Moon, Y.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.55-59
    • /
    • 2009
  • In attempts to closely study the effect of high efficiency, friendly environment HTS(High Temperature Superconducting) cable and SFCL(Superconducting Fault Current Limiters) on power system, several projects were carried out around the world. Promising results have been achieved in terms of cable capacity and reliability. commercial HTS cable and SFCL, however, must not only be only be feasible, but meet practical requirements as well. To facilitate the transition of HTS cable technology from the Lab. to the Real Grid, a New project for applying 22.9kV HTS cables and SFCL to the commercial Power Grid supported by Government has just started in KEPCO. Target of this project is to operate two 22.9kV, 50MVA, 150MVA HTS cables and two 22.9kV 630A, 3000A SFCL in a KEPCO Grid in order to demonstrate its reliability and stable operation. This paper will present the technology for selecting appropriate site and its plan for installation & operating of 22.9kV HTS cables & SFCL in KEPCO Grid.