• 제목/요약/키워드: MRI

검색결과 4,555건 처리시간 0.04초

Intraindividual Comparison of Hepatocellular Carcinoma Washout between MRIs with Hepatobiliary and Extracellular Contrast Agents

  • Yeun-Yoon Kim;Young Kon Kim;Ji Hye Min;Dong Ik Cha;Jong Man Kim;Gyu-Seong Choi;Soohyun Ahn
    • Korean Journal of Radiology
    • /
    • 제22권5호
    • /
    • pp.725-734
    • /
    • 2021
  • Objective: To intraindividually compare hepatocellular carcinoma (HCC) washout between MRIs using hepatobiliary agent (HBA) and extracellular agent (ECA). Materials and Methods: This study included 114 prospectively enrolled patients with chronic liver disease (mean age, 55 ± 9 years; 94 men) who underwent both HBA-MRI and ECA-MRI before surgical resection for HCC between November 2016 and May 2019. For 114 HCCs, the lesion-to-liver visual signal intensity ratio (SIR) using a 5-point scale (-2 to +2) was evaluated in each phase. Washout was defined as negative visual SIR with temporal reduction of visual SIR from the arterial phase. Illusional washout (IW) was defined as a visual SIR of 0 with an enhancing capsule. The frequency of washout and MRI sensitivity for HCC using LR-5 or its modifications were compared between HBA-MRI and ECA-MRI. Subgroup analysis was performed according to lesion size (< 20 mm or ≥ 20 mm). Results: The frequency of portal venous phase (PP) washout with HBA-MRI was comparable to that of delayed phase (DP) washout with ECA-MRI (77.2% [88/114] vs. 68.4% [78/114]; p = 0.134). The frequencies were also comparable when IW was allowed (79.8% [91/114] for HBA-MRI vs. 81.6% [93/114] for ECA-MRI; p = 0.845). The sensitivities for HCC of LR-5 (using PP or DP washout) were comparable between HBA-MRI and ECA-MRI (78.1% [89/114] vs. 73.7% [84/114]; p = 0.458). In HCCs < 20 mm, the sensitivity of LR-5 was higher on HBA-MRI than on ECA-MRI (70.8% [34/48] vs. 50.0% [24/48]; p = 0.034). The sensitivity was similar to each other if IW was added to LR-5 (72.9% [35/48] for HBA-MRI vs. 70.8% [34/48] for ECA-MRI; p > 0.999). Conclusion: Extracellular phase washout for HCC diagnosis was comparable between MRIs with both contrast agents, except for tumors < 20 mm. Adding IW could improve the sensitivity for HCC on ECA-MRI in tumors < 20 mm.

Factors Influencing the Background Parenchymal Enhancement in Follow-Up Breast MRI after Adjuvant Endocrine Therapy

  • Youk, Ji Hyun;Son, Eun Ju;Kim, Jeong-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권2호
    • /
    • pp.99-106
    • /
    • 2015
  • Purpose: To investigate factors influencing the evaluation of background parenchymal enhancement (BPE) at follow-up breast magnetic resonance imaging (MRI) after adjuvant endocrine therapy. Materials and Methods: One hundred twelve women with breast cancer and MRI of the contralateral unaffected breast before and after endocrine therapy were identified. Two readers in consensus performed blinded side-by-side comparison of BPE (minimal, mild, moderate, and marked) before and after therapy with categorical scales. Age, body mass index, menopausal status, treatment regimen (selective estrogen receptor modulator or aromatase inhibitor), chemotherapy, follow-up duration, BPE at baseline MRI, MRI field strength before and after therapy, and recurrence were analyzed for their influences on decreased BPE. Results: Younger age, premenopausal status, treatment with selective estrogen receptor modulator, MRI field strength, and moderate or marked baseline BPE were significantly associated with decreased BPE. In multivariate analysis, MRI field strength and baseline BPE showed a significant association. Conclusion: MRI field strength and baseline BPE before and after therapy .were associated with decreased BPE at post-therapy, follow-up MRI.

Compressed Sensing 기법을 이용한 Dynamic MR Imaging (Compressed Sensing Based Dynamic MR Imaging: A Short Survey)

  • 정홍;예종철
    • 대한전자공학회논문지SP
    • /
    • 제46권5호
    • /
    • pp.25-31
    • /
    • 2009
  • Compressed sensing은 기존의 Nyquist sampling 이론에 기반을 두었던 dynamic MRI에서의 시 공간 해상도의 제한을 획기적으로 향상시킴으로써, 최근 몇 년 사이, MR reconstruction 분야에서 가장 큰 이슈가 되고 있는 연구주제이다. Dynamic MRI 는 대부분 시간방향의 redundancy 가 매우 크므로, 쉽게 sparse 변환이 가능하다. 따라서 sparsity를 기본 조건으로 하는 compressed sensing은 거의 모든 dynamic MRI 에 대해 효과적으로 적용될 수 있다. 본 review 페이퍼에서는 최근 compressed sensing 에 기반을 두거나 영상의 sparsity를 이용하여 개발된 dynamic MR imaging algorithm 들을 간략히 소개하고, 비교 분석함으로써, compressed sensing과 같은 새로운 접근 방식의 dynamic MRI가 실제 임상에서 가져다 줄 발전 가능성을 제시한다.

MRI 소음의 특성을 이용한 공동 내부 목표점의 능동소음 제어 (Active Noise Control for Target Point Inside Bore Using Property of MRI Noise)

  • 이록행;박영진;박윤식
    • 한국소음진동공학회논문집
    • /
    • 제24권1호
    • /
    • pp.62-68
    • /
    • 2014
  • Recently, MRI(magnetic resonance imager) scanner is continually used for medical diagnosis and many biomedical researches. When it operates, however, intense noise is generated. The SPL(sound pressure level) of the noise approaches 130 dB especially in 3 T(Tesla) MRI. Meanwhile, more than 3 T MRI scanners have been developed to get higher-resolution images, so louder noise is expected in the future. The intense noise makes patients feel nervous and uncomfortable. Moreover, it could possibly cause hearing loss to patient in extreme cases. For this reason, some active noise control systems have been researched. One of them used feedback Filtered-X LMS(FXLMS) algorithm which is able to control only narrowband noises and possible to diverge in severe case. In this paper, we determine the property of MRI noise. Using the property, we applied a method of open-loop and adaptive control for reducing MRI noise at target point inside bore. We verified performance of the method with computer simulation and preliminary experiment. The results demonstrate that the method can effectively reduce MRI noise at target point.

Electromagnetic design study of a 7 T 320 mm high-temperature superconducting MRI magnet with multi-width technique incorporated

  • Jang, Won Seok;Kim, Geonyoung;Choi, Kibum;Park, Jeonghwan;Bang, Jeseok;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.30-34
    • /
    • 2021
  • Superconducting magnets have paved the way for opening new horizons in designing an electromagnet of a high field magnetic resonance imaging (MRI) device. In the first phase of the superconducting MRI magnet era, low-temperature superconductor (LTS) has played a key role in constructing the main magnet of an MRI device. The highest magnetic resonance (MR) field of 11.7 T was indeed reached using LTS, which is generated by the well-known Iseult project. However, as the limit of current carrying capacity and mechanical robustness under a high field environment is revealed, it is widely believed that commercial LTS wires would be challenging to manufacture a high field (>10 T) MRI magnet. As a result, high-temperature superconductor together with the conducting cooling approach has been spotlighted as a promising alternative to the conventional LTS. In 2020, the Korean government launched a national project to develop an HTS magnet for a high field MRI magnet as an extent of this interest. We have performed a design study of a 7 T 320 mm winding bore HTS MRI magnet, which may be the ultimate goal of this project. Thus, in this paper, design study results are provided. Electromagnetic design and analysis were performed considering the requirements of central magnetic field and spatial field uniformity.

Fast Real-Time Cardiac MRI: a Review of Current Techniques and Future Directions

  • Wang, Xiaoqing;Uecker, Martin;Feng, Li
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권4호
    • /
    • pp.252-265
    • /
    • 2021
  • Cardiac magnetic resonance imaging (MRI) serves as a clinical gold-standard non-invasive imaging technique for the assessment of global and regional cardiac function. Conventional cardiac MRI is limited by the long acquisition time, the need for ECG gating and/or long breathhold, and insufficient spatiotemporal resolution. Real-time cardiac cine MRI refers to high spatiotemporal cardiac imaging using data acquired continuously without synchronization or binning, and therefore of potential interest in overcoming the limitations of conventional cardiac MRI. Novel acquisition and reconstruction techniques must be employed to facilitate real-time cardiac MRI. The goal of this study is to discuss methods that have been developed for real-time cardiac MRI. In particular, we classified existing techniques into two categories based on the use of non-iterative and iterative reconstruction. In addition, we present several research trends in this direction, including deep learning-based image reconstruction and other advanced real-time cardiac MRI strategies that reconstruct images acquired from real-time free-breathing techniques.

fMRI 데이터를 이용한 알츠하이머 진행상태 분류 (Alzheimer progression classification using fMRI data)

  • 노주현;양희덕
    • 스마트미디어저널
    • /
    • 제13권4호
    • /
    • pp.86-93
    • /
    • 2024
  • 기능적 자기 공명영상(functional magnetic resonance imaging;fMRI)의 발전은 뇌 기능의 매핑, 휴식 상태에서 뇌 네트워크의 이해에 상당한 기여를 하였다. 본 논문은 알츠하이머의 진행상태를 분류하기 위해 CNN-LSTM 기반의 분류 모델을 제안한다. 첫 번째로 특징 추출 이전 fMRI 데이터에서 잡음을 제거하기 위해 4단계의 전처리를 수행한다. 두 번째, 전처리가 끝나면 U-Net 구조를 활용하여 공간적 특징을 추출한다. 세 번째, 추출된 공간적 특징은 LSTM을 활용하여 시간적 특징을 추출하여 최종적으로 분류하는 과정을 거친다. 실험은 데이터의 시간차원을 조절하여 진행하였다. 5-fold 교차 검증을 사용하여 평균 96.4%의 정확도를 달성하였고 이러한 결과는 제안된 방법이 fMRI 데이터를 분석하여 알츠하이머의 진행을 식별하는데 높은 잠재력을 가지고 있음을 보여준다.

유방암 환자의 수술 전 유방 MRI에서 우연히 발견된 유방 외 소견: 임상화보 (Incidental Extramammary Findings on Preoperative Breast MRI in Breast Cancer Patients: A Pictorial Essay)

  • 류진아;김신영
    • 대한영상의학회지
    • /
    • 제84권2호
    • /
    • pp.372-385
    • /
    • 2023
  • 유방암은 여성에서 가장 흔한 암이며, 많은 합병증을 발생시킨다고 알려져 있다. 오늘날 자기공명영상촬영(이하 MRI)은 유방암 수술 전 검사에서 필수적인 방법이다. 유방 MRI의 사용 빈도가 높아지면서 우연히 발견되는 유방 외 소견이 증가하고 있다. 이에 본 임상 화보에서는 유방 MRI 촬영에서 발견된 종격동, 폐, 상복부, 뼈 및 연조직 등의 다양한 유방 외 소견을 초음파(ultrasonography), 흉부 컴퓨터단층촬영(이하 CT), 간 MRI, 양전자방출단층촬영/컴퓨터단층촬영 스캔(PET/CT), 뼈 스캔(bone scan) 등과 비교하여 알아보고자 한다.

치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가 (CT and MRI image fusion reproducibility and dose assessment on Treatment planning system)

  • 안병혁;최재혁;황재웅;박지연;이두현
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.33-41
    • /
    • 2017
  • 목 적: 종양에는 최대한의 선량을 부여하고 주변의 정상조직에는 최소한의 선량이 조사되도록 부작용을 줄이는 목적으로 방사선 치료기술이 발전함에 따라 다양한 치료계획 및 치료 방법이 개발되고 있다. 방사선 치료 시 CT(Computed tomography)와 MRI(Magnetic resonance imaging)영상의 융합은 종양에 선량을 전달하는데 커다란 역할을 한다. 본 연구의 목적은 치료계획 시 자체 제작한 팬톰을 이용하여 CT와 MRI영상들의 융합을 통해 영상의 재현성 및 유용성을 평가하고 획득한 영상에서 타겟 선량을 비교, 분석해보고자 한다. 대상 및 방법: 자체 제작한 팬톰을 이용하여 CT 촬영을 하고, 자장의 세기가 다른 1.5T 와 3.0T의 MRI 촬영을 하여 영상을 획득한다. CT 촬영을 한 팬톰의 영상과 각기 다른 자장의 세기로 촬영한 팬톰의 MRI영상에서 팬톰 내에 존재하는 작은 홀의 크기 및 용적의 재현성을 비교하고, 임의의 타겟에서 선량 변화를 비교, 분석한다. 결 과: 13개의 작은 홀 직경은 CT 촬영에서 최대 31 mm, 최소 27.54 mm를 나타냈으며, 실제 제작한 것과 비교하여 평균 29.28 mm 1 % 이내로 측정되었다. 1.5T MRI 퓨전 영상에서는 최대 31.65 mm, 최소 24.3 mm를 나타냈으며, 평균 28.8 mm 1 % 이내로 측정되었다. 3.0T MRI 퓨전 영상에서는 최대 30.2 mm, 최소 27.92 mm를 나타냈으며, 평균 29.41 mm 1.3 % 이내로 측정되었다. 타겟의 조사된 선량변화는 CT에서 95.9-102.1 %, CT-1.5T MRI 퓨전영상에서 93.1-101.4 %, CT-3.0T MRI 퓨전영상에서는 96-102 %의 선량변화를 보였다. 결 론: CT 및 MRI는 영상획득 시 다른 알고리즘이 적용된다. 또한 인체의 장기는 각기 다른 밀도를 가지고 있으므로 영상 획득 시 이미지 왜곡이 발생할 수 있다. 이러한 부정확한 영상의 묘사는 타겟의 용적범위 및 선량에 영향을 주기 때문에 정확한 타겟의 용적과 위치는 불필요한 선량이 조사되는 것을 방지하며, 치료계획 시 오차를 방지할 수 있다. 즉 CT와 MRI 영상이 가지고 있는 영상 표출 알고리즘의 장점을 이용하여 치료계획에 적용해야 할 것이다.

  • PDF

F-18 FDG PET/MRI와 PET/CT 전신 영상에서 VOI를 이용한 정상부위의 $SUV_{LBM}$-최대치에 의한 영상평가 (Image Evaluation Via $SUV_{LBM}$ for Normal Regions of VOI by Using Whole Body Images Obtained from PET/MRI and PET/CT)

  • 박정규;김성규;조인호;공은정;박명환
    • 한국의학물리학회지:의학물리
    • /
    • 제24권1호
    • /
    • pp.68-75
    • /
    • 2013
  • 본 연구의 목적은 26명의 건강한 검진자들을 대상으로 PET/CT와 PET/MRI의 전신 영상에서 조기 정밀/ 진단 수준을 향상하고자 관심부피를 이용하여 정상부위의 $SUV_{LBM}$-최대치를 이용하여 PET/CT와 PET/MRI를 조영제 사용 유무와 관계없이 동시 평가할 수 있는 데이터를 구축하고자 하였다. 전신 F-18 FDG PET/CT와 전신 F-18 FDG PET/MRI의 정상부위의 VOI를 이용한 $SUV_{LBM}$-최대치평가는 PET/CT를 기준으로 PET/MRI의 영상은 매우 유의한 차이를 보였다(p<0.0001). 그러나 통계학적으로 높은 상관관계를 가진다(R>0.8). PET/MRI의 $SUV_{LBM}$ 평가 시 26.3% 감소하여 판단할 것과 조영제를 사용할 경우는 29.3% 감소하여 판단할 것으로 생각한다. PET/CT와 PET/MRI의 모든 영상의 판독에서는 $SUV_{LBM}$-최대치를 사용하는 것이 편리성과 효율성을 고려하여 임상의나 연구자들에게 많은 도움이 되리라 판단된다.