• 제목/요약/키워드: MR phase image

검색결과 61건 처리시간 0.034초

웨이블릿 부호화 자기공명영상 (Wavelet Encoded MR Imaging)

  • 김응규;이수종
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.343-346
    • /
    • 2005
  • In this study, a basic concept of wavelet encoding and its advantages over Fourier based phase encoding application. Wavelet encoding has been proposed as an alternative way to Fourier based phase encoding in magnetic resonance imaging. In wavelet encoding, the RF pulse is designed to generate wavelet-shaped excitation profile of spins. From the resulting echo signals, the wavelet transform coefficients of spin distribution are acquired and an original spin density is reconstructed from wavelet expansion. Wavelet encoding has several advantages over phase encoding. By minimizing redundancy of the data acquisition in a dynamic series of images, we can avoid some encoding steps without serious loss of quality in reconstructed image. This strategy may be regarded as data compression during imaging. Although there are some limitations in wavelet encoding, it is a promising scheme in a dynamic imaging.

  • PDF

다중 Echo를 이용한 Single Scan Inhomogeneity Field Mapping (Sine Scan Inhomogeneity Field Mapping using Multiple Echo)

  • 김치영;한수영;정관진;오창현;이윤;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.307-308
    • /
    • 1998
  • In this paper, we describe a field measurement technique using multiple gradient echo method. For this purpose, 3 differential phase map is used between two images obtained in a single scan. The phase map is further processed to unfold phase folding (2n $\pi$). The inhomogeneity map is used to correct image distortion along readout gradient direction. Some experimental results obtained at 1.0 Tesla whole body MR system are shown with the proposed technique.

  • PDF

대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성 (Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제2권1호
    • /
    • pp.96-103
    • /
    • 1998
  • 목적 : 고식적인 자기공명혈관조영술 (MR Angiography, MRA) 기법으로는 영상화가 어려웠던 대동맥궁의 주요 분지들의 평가에 있어서 새로운 MR기법인 조영증강 MRA의 임상적 유용성을 알아보고, 그 화질을 사용한 코일의 종류에 따라 비교해 보고자 한다. 대상 및 방법 : 뇌혈관 질환을 의심하여 고식적인 기법으로 뇌 및 경동맥 MRA를 시행한 29명에서 전향적으로 Gd-DAPA 15-20ml를 일시에 손으로 주입한 후 대동맥궁과 그의 주요 분지들에 대해 3시기의 고속 MRA를 시행하여 그 화질을 분석하였다. MRA는 1.0T MR기종에서 3D-FISP기법으로 얻었으며 총 영상 획득 시간은 40-60초였다. 영상 분석은 무명동맥, 양측 총경동맥, 양측 쇄골하동맥과 양측 척추 동맥들의 기시부로부터 전장에 걸쳐 화질을 주관적으로 3등급(good; 명백히 정상소견을 보이는 경우, fair; 약간 낮은 신호를 보이나 정상으로 진단하기에 비교적 만족할 만한 경우, poor; 협착이 모호하거나, 인공물이나 너무 낮은 신호로 혈관을 볼 수 없어 카테터 혈관조영술을 요하는 경우)으로 나누어 평가하였으며, 양측 총경동맥의 분기(bifurcation) 부위에서는 고식적인 기법의 영상과 그 화질을 비교평가하였다. 또한 세가지 사용한 코일의 종류(CP body array 12예, CP neck array 9예, head-and-neck 8예)에 따른 화질 차이를 정성적 및 정량적(신호대 잡음비)으로 분석하였다. 결과 : 대동맥궁 주요 분지들의 전반적인 화질은 55% (16/29)에서 'good', 34%(10/29)에서 'fair'로 평가되어 대부분 고식적인 카테터 혈과조영술이 피요치 않을 정도로 만족할 만한 화질을 보였다. 양측 총경 동맥분지 부위에서는 65%(17/26)에서 고식적인 3D-TOF기법과 같거나 나은 영상을 보였다. CP body array 코일을 사용한 경우가 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 정성적 및 정량적으로 유의하게 나은 영상을 보였다(p<0.05). 결론 : 고속 조영증강 MRA기법은 단시간내 (40-60초)에 대동맥구의 주요 분지들을 그 기시부위부터 두개골 저부에 이르기까지 대부분에서 잘 나타내주므로 선별검사로서 임상적으로 유용하리라 생각되며 CP body array 코일을 사용하였을 경우에 CP neck array 코일이나 head-and-neck 코일을 사용한 경우보다 좀더 나은 화질을 얻을 수 있으리라 생각된다.

  • PDF

일차성 간림프종: 자기공명영상과 병리소견의 연관 (Primary Hepatic Lymphoma: MR Imaging and Pathologic Correlation)

  • 김한나;신유리;나성은;정은선;오순남;최준일;정승은;이영준
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권2호
    • /
    • pp.151-155
    • /
    • 2010
  • 일차성 간림프종은 전체 림프절외장기를 침범하는 림프종의 1% 미만에서 나타나는 매우 드문 질환이다. 저자들은 수술로 확진된 일차성 간림프종의 자기공명영상과 병리 소견의 특징을 보고한다. 간세포 특이 조영제를 주입하여 얻은 역동적 조영증강 영상에서 점차적으로 조영증강되어 간내담관암과 유사하게 보였다. 그러나 20분 지연 후 얻은 간담관기 영상과 확산강조영상에서 서로 다른 신호강도를 보이는 세 층의 띠모양의 병변이 특징적으로 보였으며 이는 병리적으로 외층의 생존 종양, 중간층의 괴사된 종양, 및 종양에 둘러싸인 중앙부의 괴사된 간 실질과 일치되는 소견을 보였다.

위상영상 획득 시 T1 shortening effect를 이용한 혈관의 신호 증가에 관한 연구 (The increase of blood vessels using a signal during the image acquisition phase T1 shortening effect)

  • 이호범;최관우;손순룡;민정환;이종석;유병규
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4704-4710
    • /
    • 2015
  • 본 연구는 가돌리늄 조영제의 T1 shortening effect를 이용하여 말초동맥으로 갈수록 신호강도가 낮아지는 위상영상의 단점을 근본적으로 개선함으로써 진단에 유용한 영상을 획득하고자 하였다. 연구기간은 2014년 10월부터 동년 12월까지 시행하였으며, 심장질환자를 제외한 AVM 환자 30명을 대상으로 하였다. 연구방법은 T1 shortening effect에 따른 신호강도의 차이를 알아보기 위해 가돌리늄 조영제 주입 전 후 자화강조영상을 획득한 다음, 위상영상을 비교평가 하였다. 연구결과, 가돌리늄 조영제 주입 전, 후 뇌실질 내 말초동맥의 신호강도는 가돌리늄 조영제 주입 후가 주입 전에 비해 전두엽 19.45%, 측두엽 23.09%, 두정엽 18.82%, 후두엽 25.45%, 소뇌 20.93%로 증가 하였고 통계적으로 유의하였다. 그러므로 위상영상 획득 시 가돌리늄 조영제의 T1 shortening effect를 이용하면 위상영상의 단점을 보완할 수 있어 진단 및 치료에 유용한 영상을 획득할 수 있으리라 사료된다.

Evaluation and Prediction of Post-Hepatectomy Liver Failure Using Imaging Techniques: Value of Gadoxetic Acid-Enhanced Magnetic Resonance Imaging

  • Keitaro Sofue;Ryuji Shimada;Eisuke Ueshima;Shohei Komatsu;Takeru Yamaguchi;Shinji Yabe;Yoshiko Ueno;Masatoshi Hori;Takamichi Murakami
    • Korean Journal of Radiology
    • /
    • 제25권1호
    • /
    • pp.24-32
    • /
    • 2024
  • Despite improvements in operative techniques and perioperative care, post-hepatectomy liver failure (PHLF) remains the most serious cause of morbidity and mortality after surgery, and several risk factors have been identified to predict PHLF. Although volumetric assessment using imaging contributes to surgical simulation by estimating the function of future liver remnants in predicting PHLF, liver function is assumed to be homogeneous throughout the liver. The combination of volumetric and functional analyses may be more useful for an accurate evaluation of liver function and prediction of PHLF than only volumetric analysis. Gadoxetic acid is a hepatocyte-specific magnetic resonance (MR) contrast agent that is taken up by hepatocytes via the OATP1 transporter after intravenous administration. Gadoxetic acid-enhanced MR imaging (MRI) offers information regarding both global and regional functions, leading to a more precise evaluation even in cases with heterogeneous liver function. Various indices, including signal intensity-based methods and MR relaxometry, have been proposed for the estimation of liver function and prediction of PHLF using gadoxetic acid-enhanced MRI. Recent developments in MR techniques, including high-resolution hepatobiliary phase images using deep learning image reconstruction and whole-liver T1 map acquisition, have enabled a more detailed and accurate estimation of liver function in gadoxetic acid-enhanced MRI.

자기공명 Tailored-RF 경사자계반향영상법을 이용한 고양이 뇌에서의 First-Pass관찰 (First-Pass Observation using Tailored-RF Gradient Echo (TRFGE) MR Imaging in Cat Brain)

  • 문치웅;노용만
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.209-216
    • /
    • 1995
  • Recently, a new tailored RF gradient echo (TRFGE) sequence was reported. This technique not only enhances the magnetic susceptibility effect but also allows us to measure local changes in brain oxygenation. In this study, a phantom and cat brain experiments were performed on a 4.7 Tesla BIQSPEC (BRUKER) instrument with a 26 cm gradient system. We have demonstrated that the signal intensity (SI) of the TRFGE sequence varies according to the concentration of susceptibility contrast agent. Three capillary tubes with different concentrations of Gd-DTPA (0.01, 0.05, 0.1 mMOI/l) were placed at the middle of a cylindrical water phantom. Using both TRFGE and conventional gradient echo (CGE) sequences, phantom images of the slices which contain all three tubes were obtained. For the animal experiment, cats were anesthetized and ventilated using halotane (0.5%) and a $N_2O/ O_2$ mixture (2:1), and blood pressure and heart rate were monitored and kept normal. For the observation of tue first pass of Gd- DTPA, imaging was started at t = 0. At t = 8 ~ 12s, 0.2 mMol/Kg Gd-DTPA was manually injected in the femoral vein. The imaging parameters were TRITE = 25/10 msec, flip angle = $30^{\circ}$, FOV = 10cm, image matrix size = $128{\times}128$ with 64 phase encodings and the image data acquisition window was 10 msec. SI-time curves were then obtained from a series of 30 images which were collected at 2 sec intervals using both CGE and TRFGE pulse sequences before, during, and following the contrast injection.

  • PDF

토끼의 횡격막 파열 진단에 있어서 자기공명영상, 나선형전산화단층촬영 및 초음파의 가치 비교 (Comparative Evaluations of Magnetic Resonance Image, Spiral Computed Tomography and Ultrasound in the Diasnosis of Experimental Diaphragmatic Rupture in the Rabbit)

  • 김학희;정승은;이배영;최병길;신경섭
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.154-161
    • /
    • 1997
  • 목적: 횡격막 파열은 그 진단이 어렵고 지연되는 경우가 많으며, 진단이 늦어지면 유병율과 사망율이 높아지므로 조기진다는 매우 중요하다. 저자들은 최근 많이 이용되는 영상진단법인 나선형 CT와 자기공명영상, 그리고 초음파건사중 어떤 방법이 가장 예민하고 정확한 진단방법인지 동물실험 모델을 통하여 평가하고자 하였다. 대상 및 방법: 토끼에서 인위적으로 횡격막파열을 대, 중, 소로 만든 후 1일, 3일, 7일째 나선형 CT와 자기공명영상, 그리고 초음파검사를 동시에 시행하였다. 결과: 횡격막파열의 진단 민감도와 특이도는 초음파검사가 94.4%와 92.9%, 자기 공명영상이 54.0%와 85.75, 나선형 CT가 46.0%와 78.6%이었다. 횡격막 파열의 진단은 초음파검사, 자기공명영상, 나선형 CT순으로 정확하였으며 초음파 검사가 자기공명영상이나 나선형 CT보다 유의하게 우월하였고(P<0.05), 자기공명영상과 나선형 CT는 유의한 차이가 없었다. 초음파검사는 파열의 크기와 상관없이 횡격막파열의 구별이 용이하였고 자기공명영상과 나선형 CT는 파열의 크기가 클수록 횡격막파열의 구별이 용이하였으나 통계적으로 유의한 차이는 없었다(P>0.05). 수술후 1일에는 전예에서 늑막삼출액이나 혈흉을 동반하였다. 이때에는 초음파나 자기공명영상이 나선형 CT에 비해 우월하였다. 시간경과에 따랄 초음파검사와 자기공명영상은 진단율이 상대적으로 저하되었으나 통게적으로 유의한 차이는 없었다(P>0.05) 탈장을 동반한 경우에는 진단의 민감도가 자기공명영상, 나선형 CT, 초음파검사순으로 높았으며 초음파검사가 상대적으로 낮았다. 그러나 통계적으로 유의한 차이는 없었다(P>0.05). 결론: 초음파검사가 횡격막파열의 진단에 가장 유용한 것으로 밝혀졌으며, 이러한 결과는 앞으로 임상에 적용하여 검증되어야 할 필요가 있다고 생각된다.

  • PDF

The Method of Reducing Echo Time in 3D Time-of-flight Angiography

  • Park, Sung-Hong;Park, Jung-Il;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.367-369
    • /
    • 2002
  • We have designed ramp profile excitation pulse based on the Shinnar-Le Roux (SLR) algorithm. The algorithm provides many advantages to pulse designers. The first advantage is the freedom of deciding the amplitudes, frequencies, and ripple sizes of stopband, passband, and transition band of pulse profile. The second advantage is the freedom of deciding the pulse phase, more specifically, minimum phase, linear phase, maximum phase, and any phase between them. The minimum phase pulse is the best choice in the case of 3D TOF, because it minimizes the echo time, which implies the best image quality in the same MR examination condition. In addition, the half echo technique is slightly modified in our case. In general, using the half echo technique means that the acquired data size is half and the rest part can be filled with complex conjugate of acquired data. But in our case, the echo center is just shifted to left, which implies the reduction of echo time, and the acquired data size is the same as the one without using the half echo technique. In this case, the increase of right part of data leads to improvement of the resolution and the decrease of left part of data leads to decrease of signal to noise ratio. Since in the case of 3D TOF, the signal to noise ratio is sufficiently high and the resolution is more important than signal to noise ratio, the proposed method appears to be significantly affective and gives rise to the improved high resolution angiograms.

  • PDF

액주형 동축노즐 분무의 무화특성에 관한 실험적 연구 (An experimental study on the atomizing characteristics of liquid column type coaxial sprays)

  • 노병준;강신재;오제하
    • 오토저널
    • /
    • 제14권5호
    • /
    • pp.41-53
    • /
    • 1992
  • The main purpose of this study is to investigate the atomizing characteristics of a two phase spray by using a liquid column type coaxial nozzle. The experiments have been carried out to analyze the atomization behavior, the droplet size distributions, and the statistical properties of droplet size distributions. Immersion sampling method and the image processing technique were adapted for the measurements of particles, and the distributions of the droplet sizes were statistically analyzed. In the experiments, the mass ratio defined as Mr= $M_{\sigma}$/ $M_{1}$ has been changed from 1.0 to 3.4 and the measurements have been performed along the axis of the spray. As a result of this experimental study, the distributions of droplet size were satisfied with the Log-Normal distributions and arithmetic mean diameter and deviation of mass ratio. Droplet volume-surface mean diameter was denoted by a exponential function of mass-ratio and the exponent was denoted by linear relation according to the central axis from the nozzle. Dispersions, skewness factors and flatness factors had comparatively constant values regardless of mass ratio and location.

  • PDF