• Title/Summary/Keyword: MOST Model

Search Result 16,608, Processing Time 0.044 seconds

A rock physics simulator and its application for $CO_2$ sequestration process ($CO_2$ 격리 처리를 위한 암석물리학 모의실헝장치와 그 응용)

  • Li, Ruiping;Dodds, Kevin;Siggins, A.F.;Urosevic, Milovan
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.67-72
    • /
    • 2006
  • Injection of $CO_2$ into underground saline formations, due to their large storage capacity, is probably the most promising approach for the reduction of $CO_2$ emissions into the atmosphere. $CO_2$ storage must be carefully planned and monitored to ensure that the $CO_2$ is safely retained in the formation for periods of at least thousands of years. Seismic methods, particularly for offshore reservoirs, are the primary tool for monitoring the injection process and distribution of $CO_2$ in the reservoir over time provided that reservoir properties are favourable. Seismic methods are equally essential for the characterisation of a potential trap, determining the reservoir properties, and estimating its capacity. Hence, an assessment of the change in seismic response to $CO_2$ storage needs to be carried out at a very early stage. This must be revisited at later stages, to assess potential changes in seismic response arising from changes in fluid properties or mineral composition that may arise from chemical interactions between the host rock and the $CO_2$. Thus, carefully structured modelling of the seismic response changes caused by injection of $CO_2$ into a reservoir over time helps in the design of a long-term monitoring program. For that purpose we have developed a Graphical User Interface (GUI) driven rock physics simulator, designed to model both short and long-term 4D seismic responses to injected $CO_2$. The application incorporates $CO_2$ phase changes, local pressure and temperature changes. chemical reactions and mineral precipitation. By incorporating anisotropic Gassmann equations into the simulator, the seismic response of faults and fractures reactivated by $CO_2$ can also be predicted. We show field examples (potential $CO_2$ sequestration sites offshore and onshore) where we have tested our rock physics simulator. 4D seismic responses are modelled to help design the monitoring program.

Construction and characterization of heterozygous diploid Escherichia coli (2배체 대장균의 제조와 그 특성)

  • Jung, Hyeim;Lim, Dongbin
    • Korean Journal of Microbiology
    • /
    • v.52 no.4
    • /
    • pp.406-414
    • /
    • 2016
  • Among 6 leu codons, CUG is the most frequently used codon in E. coli. It is recognized by leu-tRNA(CAG) encoded by four genes scattered on two chromosomal loci (leuT and leuPQV ). In the process of constructing a strain with no functional leu-tRNA (CAG) gene on chromosome, we made two mutant strains separately, one on leuPQV locus (${\Delta}leuPQV$), and the other on leuT locus [$leuT^*$(GAG)], where the anticodon of leuT was changed from CAG to GAG, thereby altering its recognition codon from CUG to CUC. We attempted to combine these two mutations by transduction using $leuT^*$(GAG) strain as a donor and ${\Delta}leuPQV$ strain as a recipient. Large and small colonies appeared from this transduction. From PCR and DNA sequencing, large colony was confirmed to be the reciprocal recombinant as expected, but the small colonies contained both mutant $leuT^*$(GAG) and wild type leuT (CAG) genes in the cell. This heterozygous diploid strain did not show any unusual morphology under microscopic observation, but, interestingly, it showed a linear growth curve in rich medium with much slower growth rate than wild type cell. It always formed homogenous small colonies in the selection medium, but, when there was no selection, it readily segregated into $leuT^*$(GAG) and leuT (CAG). From these observations, we suggested that the strain with both $leuT^*$(GAG) and leuT (CAG) genes was not a partial diploid (merodiploid), but a full diploid cell having two different chromosomes. We proposed a model explaining how such a heterozygous diploid cell was formed and how and why its growth showed a linear growth curve.

Temperature Compensation of Optical FBG Sensors Embedded Tendon for Long-term Monitoring of Tension Force of Ground Anchor (광섬유 센서 내장형 텐던을 이용한 그라운드 앵커의 장기 장력모니터링을 위한 온도보상)

  • Sung, Hyun-Jong;Kim, Young-Sang;Kim, Jae-Min;Park, Gui-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.13-25
    • /
    • 2012
  • Ground anchor method is one of the most popular reinforcing technology for slope in Korea. For the health monitoring of slope which is reinforced by permanent anchor for a long period, monitoring of the tension force of ground anchor is very important. However, since electromechanical sensors such as strain gauge and V/W type load cell are also subject to long-term risk as well as suffering from noise during long distance transmission and immunity to electromagnetic interference (EMI), optical FBG sensors embedded tendon was developed to measure strain of 7-wire strand by embedding FBG sensor into the center king cable of 7-wire strand. This FBG sensors embedded tendon has been successfully applied to measuring the short-term anchor force. But to adopt this tendon to long-term monitoring, temperature compensation of the FBG sensors embedded tendon should be done. In this paper, we described how to compensate the effect in compliance with the change of underground temperature during long-term tension force monitoring of ground anchors by using optical fiber sensors (FBG: Fiber Bragg Grating). The model test was carried out to determine the temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon. The determined temperature sensitivity coefficient ${\beta}^{\prime}=2.0{\times}10^{-5}/^{\circ}C$ was verified by comparing the ground temperatures predicted from the proposed sensor using ${\beta}^{\prime}$ with ground temperatures measured from ground thermometer. Finally, temperature compensations were carried out based on ${\beta}^{\prime}$ value and ground temperature measurement from KMA for the tension force monitoring results of tension type and compression type anchors, which had been installed more than 1 year before at the test site. Temperature compensated tension forces are compared with those measured from conventional load cell during the same measuring time. Test results show that determined temperature sensitivity coefficient (${\beta}^{\prime}$) of FBG sensors embedded tendon is valid and proposed temperature compensation method is also appropriate from the fact that the temperature compensated tension forces are not dependent on the change of ground temperature and are consistent with the tension forces measured from the conventional load cell.

STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH (치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포)

  • Han, Sang-Un;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

Validation of Food Intake Frequency from Food Frequency Questionnaire for Use as a Covariate in a Model to Estimate Usual Food Intake (식품의 일상섭취량 추정을 위한 식품섭취빈도의 활용가능성 및 타당도 연구)

  • Lee, Ja Yoon;Kim, Dong Woo
    • Culinary science and hospitality research
    • /
    • v.23 no.2
    • /
    • pp.64-73
    • /
    • 2017
  • Although 24-hour recalls (24HR) capture detailed information on a person's food intake, this method suffers from difficulties in adequately measuring the usual intake of foods that are not consumed daily by most. Therefore, the purpose of this study is to investigate whether frequency of Food Frequency Questionnaire (FFQ) can be utilized in form of covariate when calculating usual intake of episodically-consumed foods and their distributions. Data used in this study was from the Korean National Healthy and Nutrition Examination Survey (KNHANES) 2012~2014 (3 years) and 10,945 subjects participated in this survey who performed both of 24HR and FFQ. In order to analyze the data, amount of intake in each food, which was reported in 24HR was recalculated according to 112 items in FFQ. We first assessed the relationship between FFQ frequency and the amount reported on 24HR. Second, we assessed the relationship between usual portion size of FFQ and the amount reported on 24HR. Our hypothesis was that people who reported high FFQ-reported frequency or FFQ-reported usual portion size would consume larger amounts of that food on 24HR than those with lower frequency or portion size of consumption of a food on the FFQ. For 59 of 112 individual foods (52.2%), there were statistically significant increasing relationships between FFQ frequency and consumption-day intake. Also, 102 of 112 individual foods (90.3%), there were statistically significant increasing relationships between FFQ usual portion size and consumption-day intake. For 10 of 13 food groups (grains, fruits, eggs, pulses, root and tuber crops, milk products, meat, beverage, alcoholic drink, vegetable, seaweeds and others), there were statistically significant increasing relationships between FFQ frequency and consumption-day intake. And there were statistically significant increasing relationships between FFQ usual portion size and consumption-day intake for all food groups. This study confirmed consistent correlation between reported FFQ frequency or usual portion size of food (group) consumption and consumption-day intake on 24HR. Therefore the frequency data may be utilized as important covariate when estimating usual intake of food or food groups.

A Theory Construction on the Care Experience for Spouses of Patients with Chronic Illness (만성질환자 배우자의 돌봄 경험에 대한 이론 구축)

  • Choi, Kyung-Sook;Eun, Young
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.1
    • /
    • pp.122-136
    • /
    • 2000
  • Chronic illness requiring attention and management during a long period of time puts great burden onto patients, their family and society. For patients with chronic illnesses, providing social support is the most important, and the fundamental support comes from their spouses. Amount and quality of support from spouses seems to differentiated according to the sex of patients. Female patients tend to believe that their spouses are not very supportive. Therefore, the researchers assessed the burden of husbands of female arthritis patients to discover the factors that result in greater burden. Also, they developed a theoretical model of husbands′ care for their wives through a qualitative research into husbands′ experience. Method 1: The study material was 650 female arthritis patients registered in an arthritis clinic. The questionnaire about the disease experience of female arthritis patients and the burden of husbands were sent. Returned questionnaires numbered 210(32.3%) and 27 were excluded because of inadequate answers. The remaining 183 questionnaires were analyzed. The mean age of the patients was 51 years and the mean age of spouses was 55 years. The mean marital period was 28 years. The average duration since diagnosis was 9.1 years. Education level was varied from primary school to graduate school, and average income/month was 1,517,300 won. Method 2: Initial questionnaire studies on the burden of husbands were performed. Among 183 responding husbands, 23 consented to participate for a qualitative research. Data was obtained by direct and telephone interviews. The mean age of participants was 58 years, and the educational level and socioeconomic status also varied. Result: 1. Husbands′ burden: The average burden was 57.68 with a range of 6-96. 2. Burden and general characteristics: The husband′s burden correlated with the age of the patients, numbers in the family, therapy methods, patient′s level of discomfort, patient′s disease severity, patient′s level of dependence and the husband′s understanding of the level of severity. 3. Linear correlation analysis on burden: The husbands′ burden is explained in 22.5% by husband′s recognition of level of severity and husbands′ age. 4. There were four patterns of the burden on husbands: both objectve burden and subjective burden were high(pattern I), both of objectve burden and subjective burden were low(pattern II), objective burden was high but subjective burden was low(pattern III), objective burden was low but subjective burden was high(pattern IV). The pattern was correlated with the family income, educational level of the patients and their husbands, therapy methods, patient′s level of discomfort, patient′s disease severity, patient′s level of dependence and husband′s understanding of level of severity. 5. The core category of the caring experience of the husbands with arthritis patients was "companionship". The causal factor was the patients′ experience due to symptoms : physical disfigurement, pain, immobility, limitation of house chores, and limitation of social activities. Contextural factors are husbands′ identification of housework and husbands′ concern about the disease. The mediating factors are economic problems, fear of aging, feeling of limitation and family support. The strategy for interaction is mind control and how to solve emotional stress. The "companionship" resulted from caring activities, participation of household activities, helping patients′ to coping with emotional experience. 6. Companionship is established through the process of entering intervention, and caring state of mind. Entering intervention is the phase of participation of therapy and involvement of houseworks. The caring phase consists of decision on therapy, providing therapy, providing direct care, and taking over the household role of wife. Through caring phase, the changing phase set a stage in which husbands consolidate the relationship with their wives, and are reminded of the meaning of marriage. As a result, in changing phase, husbands′ companionship is enhanced. In conclusion, nursing care of chronic illnesses should include a family member especially the spouse. All information on disease shoud be provided to patients and whole family member. Strong support should also be provided to overcome difficulties in taking over role of other sex. Then the quality of life of patients and families will be much improved.

  • PDF

A Study on the Evaluative Models and Indicators for Diagnosis of Urban Visual Landscape - Focusing on Seoul City - (도시경관 진단을 위한 평가모델 및 지표개발 연구 - 서울시를 중심으로 -)

  • Kim, Seung-Ju;Im, Seung-Bin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.78-86
    • /
    • 2009
  • Recently, there seems to besome problems in the urban visual landscape as a result of continuous economic growth and industrial development. At the same time, the public has begun to be aware of the importance of visual resources, and the necessity for visual landscape conservation and improvement. Therefore, the development of evaluative indicators for systematic visual landscape planning and design is urgent. The purpose ofthis study is to discover evaluative models and indicators for the diagnosis of urban visual landscapes. This study included the selection of 18 physical indicators(statistical data) by literature reviews, adoption of field and questionnaire surveys at 12 autonomous districts in Seoul and surrounding major mountain valleys and river streams(i.e. Mt. Nam and Han-River). The content of the questionnaire is scenic beauty. Moreover, the linear regression analysis between the scenic beauty mean scores and the physical indicator scores figure out the scenic beauty prediction model. As this study suggests, the most important indicators in urban visual landscapes are 'Greens', 'Park' and 'the number of apartment buildings(higher than 20 stories).' Based on the results, greens and parks should be priority elements to considerin urban landscape planning and design. Moreover, since the number of apartment buildings that are higher than 20 stories has a negative correlation with the scenic beauty score, it can be used as basic data for landscape planning. For the scenic beauty prediction models and evaluative indicators suggest a direction of urban management, each indicator becomes basic data for visual landscape planning and design. In following studies, if physical indicators and case studies are added, the scenic beauty prediction models and evaluative indicators could be more synthetic and systematic. Moreover, the development of physical indicators in three dimensions(3D)(i.e. results from visual district analysis, view surface analysis) could be expected to obtain more general and varied results.

Analysis of the Geological Structure of the Hwasan Caldera Using Potential Data (포텐셜 자료해석을 통한 화산칼데라 구조 해석)

  • Park, Gye-Soon;Yoo, Hee-Young;Yang, Jun-Mo;Lee, Heui-Soon;Kwon, Byung-Doo;Eom, Joo-Young;Kim, Dong-O;Park, Chan-Hong
    • Journal of the Korean earth science society
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • A geophysical mapping was performed for Hwasan caldera which is located in Euisung Sub-basin of the southeastern part of the Korean Peninsula. In order to overcome the limitation of the previous studies, remote sensing technic was used and dense potential data were obtained and analyzed. First, we analyzed geological lineament for target area using geological map, digital elevation model (DEM) data and satellite imagery. The results were greatly consistent with the previous studies, and showed that N-S and NW-SE direction are the most dominant one in target area. Second, based on the lineament analysis, highly dense gravity data were acquired in Euisung Sub-basin and an integrated interpretation considering air-born magnetic data was made to investigate the regional structure of the target area. The results of power spectrum analysis for the acquired potential data revealed that the subsurface of Euisung Sub-basin have two density discontinuities at about 1 km and 3-5 km depth. A 1 km depth discontinuity is thought as the depth of pyroclastic sedimentary rocks or igneous rocks which were intruded at the ring vent of Hwasan caldera, while a 3-5 km depth discontinuity seems to be associated with the depth of the basin basement. In addition, three-dimensional gravity inversion for the total area of Euisung Sub-basin was carried out, and the inversion results indicated two followings; 1) Cretaceous Palgongsan granite and Bulguksa intrusion rocks, which are located in southeastern part and northeastern part of Euisung Sub-basin, show two major low density anomalies, 2) pyroclastic rocks around Hwasan caldera also have lower density when compared with those of neighborhood regions and are extended to 1.5 km depth. However, a poor vertical resolution of potential survey makes it difficult to accurately delineate the detailed structure caldera which has a vertically developed characteristic in general. To overcome this limitation, integrated analysis was carried out using the magnetotelluric data on the corresponding area with potential data and we could obtain more reasonable geologic structure.

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

The study on the shear bond strength of resin and porcelain to Titanium (티타늄에 대한 레진과 도재의 결합 강도에 관한 연구)

  • Park, Ji-Man;Kim, Yeong-Soon;Jun, Sul-Gi;Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.46-52
    • /
    • 2009
  • Statement of problem: Recently, titanium has become popular as superstructure material in implant dentistry because titanium superstructure can be easily milled by means of computer-aided design and manufacture (CAD/CAM) technique. But retention form such as nail head or bead cannot be cut as a result of technical limitation of CAD/CAM milling and bond strength between titanium and porcelain is not as strong as that of conventional gold or metal alloy. Purpose: The objective of this study was to evaluate the shear bond strength of three different materials: heat curing resin, composite resin, porcelain which were bonded to grade II commercially pure Titanium (CP-Ti). Material and methods: Thirty seven CP-Ti discs with 9 mm diameter, 10 mm height were divided into three groups and were bonded with heat curing resin (Lucitone 199), indirect composite resin (Sinfony), and porcelain (Triceram) which were mounted in a former with 7 mm diameter and 1 mm height. Samples were thermocycled for 1000 cycles at between $5-55^{\circ}C$. Shear bond strength (MPa) was measured with Instron Universal Testing Machine with cross head speed of 1 mm/min. The failure pattern was observed at the fractured surface and divided into adhesive, cohesive, and combination failure. The data were analyzed by one-way ANOVA and Scheffe's multiple range test (${\alpha}=0.05$). Results: Lucitone 199 ($17.82{\pm}5.13\;MPa$) showed the highest shear bond strength, followed by Triceram ($12.97{\pm}2.11\;MPa$), and Sinfony ($6.00{\pm}1.31\;MPa$). Most of the failure patterns in Lucitone 199 and Sinfony group were adhesive failure, whereas those in Triceram group were combination failure. Conclusion: Heat curing resin formed the strongest bond to titanium which is used as a CAD/CAM milling block. But the bond strength is still low compared with the bond utilizing mechanical interlocking and there are many adhesive failures which suggest that more studies to enhance bond strength are needed.