• Title/Summary/Keyword: MINI

Search Result 2,096, Processing Time 0.033 seconds

대형최적화모델의 소형 COMPUTER 적용을 위한 효율적인 IN-CORE STORAGE ALLOCATION

  • 안규호
    • Korean Management Science Review
    • /
    • v.2
    • /
    • pp.48-52
    • /
    • 1985
  • 최근 Mini 및 Micro Computer 산업의 급속한 발전은 상대적으로 저렴한 가격의 Computer System 보급이 가능하게 되어 Mini 및 Micro computer의 확산은 증가하는 추세에 있다. 또한 일반적으로 Mathematical Programming 기법으로 접근하는 real-world 최적화 모델은 결정 변수나 제약 조건의 수로 볼때 대형화하고 있다.(중략)

  • PDF

Effect of dual pitch mini-implant design and diameter of an orthodontic mini-implant on the insertion and removal torque (교정용 미니임플랜트의 이중 피치와 직경의 차이가 삽입 및 제거 토크에 미치는 영향 평가)

  • Kim, Jong-Wan;Cho, Il-Sik;Lee, Shin-Jae;Kim, Tae-Woo;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.36 no.4
    • /
    • pp.275-283
    • /
    • 2006
  • Objective: Small orthodontic mini-implants are useful as anchorage. However they have some weaknesses such as loosening. This study was carried out to analyze the mechanical effects of the dual pitch and diameter on the insertion and removal torque of mini-implants. Methods: The threads of mini-implants were mono and dual pitch. The diameters of mini-implants were 1.4 mm and 1.6 mm. Four groups were tested (mono 1.4 mm, mono 1.6 mm, dual 1.4 mm and dual 1.6 mm). All were inserted and removed on polyurethane foam with the torques being measured. Results: The maximum torque of the dual pitch groups was higher than the mono pitch groups during removal but lower during insertion. The maximum torque of the 1.6 mm diameter groups was higher than the 1.4 mm diameter groups during insertion and removal. The dual pitch 1.4 mm group showed the lowest insertion torque but had similar or superior levels of removal torque to that of the mono pitch 1.6 mm group. Conclusions: The dual pitch especially showed a continuous high removal torque after the peak. Despite the small diameter, the dual pitch might improve the initial mechanical stability.

A Survey on the Consumer Packaging Preferences for Mini Pot Flower Plants on Domestic Market in Korea (소형 분화류의 포장재 및 포장용기에 대한 소비자의 기호도 조사)

  • Lee, Sun Yup;Woo, Hyun Jeong;Lee, Youn Suk
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.1
    • /
    • pp.47-53
    • /
    • 2017
  • In this study we surveyed the preferences of consumer packaging for mini pot flower plants to improve the flower market application in Korea. The surveys were consisted of the consumers residing in Seoul metropolitan (221), Gyeonsang (70), Jeonla (29), Chungceong (19), Gangwon (7), other provinces (3). A total of 349 eligible respondents (male 173, female 176) were surveyed with a self-administered questionnaire asking on the general characteristics for residents, packaging material, packaging design, type of flower pot, degree of transparency, convenience, consumer's demand for packaging development, a significant point when purchasing the flower pot product. The collected date was analyzed using a chi-square (${\chi}^2$) statistical test in SPSS program. Most residents prefer for mini pot flower plants packed with packaging characteristics of plastic material (56.4%), packaging design of separated type (76.2%), angled type (62.5%), and transparency (48.6%). The other question results showed that major consumer's demand for mini pot flower plants is maintaining the freshness quality and stability structure for them. Transparency of packaging can also affect directly the preferences for purchasing the mini pot flower plants. The packaging structure with a proper shape design may protect the fresh mini pot flower plants from shock or any other damage during distribution. The results of this study help to provide consumer's demand for packaging development and to give the greatest advantages in terms of production and marketability of mini pot flower plants.

Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants (교점용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교)

  • Yun, Soon-Dong;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.95-104
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the effect of length and shape of cutting flute on mechanical properties of orthodontic mini-implants. Methods: Three types of mini-implants with different flute patterns (Type A with 2.6 mm long flute, Type B with 3.9 mm long and straight flute, Type C with 3.9 mm long and helical flute) were inserted into the biomechanical test blocks (Sawbones Inc., USA) with 2 mm and 4 mm cortical bone thicknesses to test insertion and removal torque. Results: In 4 mm cortical bone thickness, Type C mini-implants showed highest maximum insertion torque, then Type A and Type B in order. Type C also showed shortest total insertion time and highest maximum removal torque, but Type A and B didn't showed statistically significant difference in insertion time and removal torque. In 2 mm cortical bone thickness, there were no significant difference in total insertion time and maximum removal torque in three types of mini-implants, but maximum insertion torque of Type A was higher than two other Types of mini-implants. Conclusions: Consideration about length and shape of cutting flute of mini-implant is also required when the placement site has thick cortical bone.

Influence of surface treatment on the insertion pattern of self-drilling orthodontic mini-implants (표면처리가 교정용 미니 임플랜트의 식립수직력과 토크에 미치는 영향)

  • Kim, Sang-Cheol;Kim, Ho-Young;Lee, Sang-Jae;Kim, Cheol-Moon
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.268-279
    • /
    • 2011
  • Objective: The purpose of this study was to compare self-drilling orthodontic mini-implants of different surfaces, namely, machined (untreated), etched (acid-etched), RBM (treated with resorbable blasting media) and hybrid (RBM + machined), with respect to the following criteria: physical appearance of the surface, measurement of surface roughness, and insertion pattern. Methods: Self-drilling orthodontic mini-implants (Osstem implant, Seoul, Korea) with the abovementioned surfaces were obtained. Surface roughness was measured by using a scanning electron microscope and surface-roughness-testing machine, and torque patterns and vertical loadings were measured during continuous insertion of mini-implants into artificial bone (polyurethane foam) by using a torque tester of the driving-motor type (speed, 12 rpm). Results: The mini-implants with the RBM, hybrid, and acid-etched surfaces had slightly increased maximum insertion torque at the final stage ($p$ < 0.05). Implants with the RBM surface had the highest vertical load for insertion ($p$ < 0.05). Testing for surface roughness revealed that the implants with the RBM and hybrid surfaces had higher Ra values than the others ($p$ < 0.05). Scanning electron microscopy showed that the implants with the RBM surface had the roughest surface. Conclusions: Surface-treated, self-drilling orthodontic mini-implants may be clinically acceptable, if controlled appropriately.

Delayed Lacrimal Stent Implantation Using Mini Monoka$^{(R)}$ in Canalicular Laceration (누소관 열상환자에서 Mini Monoka$^{(R)}$를 이용한 지연된 스텐트 삽입술)

  • Hwang, Jae-Ha;Kim, Hong-Min;Kim, Ji-Hoon;Kim, Kwang-Seog;Lee, Sam-Yong
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.32-37
    • /
    • 2011
  • Purpose: Canalicular laceration is relatively common due to its exposed, vulnerable location in case of facial trauma. Conjunctivodacryocystorhinostomy has been the standard treatment for canalicular obstruction secondary to unrepaired canalicular laceration. In spite of a high rate of relieving tear-duct obstruction, this method is noted to be associated with low rate of patient satisfaction and a number of complications. The goal of this study is to report the good results of delayed lacrimal stent implantation with Mini Monoka$^{(R)}$ for patients whose canaliculi were not repaired by initial surgery. Methods: From May of 2005 to February of 2007, four patients who underwent delayed lacrimal stent implantation using Mini Monoka$^{(R)}$ in canalicular laceration were retrospectively reviewed. First, the previous scar incision was made over the lower lid and we identified the cut end of proximal lacerated canaliculus. The Mini Monoka$^{(R)}$ was passed through the punctum to the cut end of the proximal lacerated canaliculus. We identified the cut end of the distal lacerated canaliculus, whose cut end has rolled white edges after careful excision of the scarred lid tissue. We then passed Mini Monoka$^{(R)}$ through the lacerated inferior canaliculus. Using an operating microscope, we placed three interrupted sutures of 8-0 Ethilon to join the canalicular ends. Silicone stent was left in place for 6 months. The mean age of the patients was 48.5 years (range, 35 to 59 years). The time interval from initial trauma to delayed lacrimal stent implantation was between 3 and 31 days. Follow-up periods ranged from 12 and 20 months. Results: The results of reconstruction were classified into normal, fair and poor. Patent lacrimal drainage systems were achieved in three of the four cases. In one case, epiphora was encountered. No cases of stent displacement, conjunctivitis or granuloma formation were encountered. Conclusion: Even though canalicular reconstruction was delayed for a long time, attempting canalicular reconstruction would be acceptable before considering secondary operations like dacryocystorhinostomy and conjunctivodacryocystorhinostomy.

  • PDF

Reduction of pesticide residues in/on mini-tomato by washing at the different harvest days after pesticide spray (약제 살포 후 경과일수별 세척에 의한 방울토마토의 잔류농약경감)

  • Kwon, Hye-Young;Kim, Jin-Bae;Lee, Hee-Dong;Ihm, Yang-Bin;Kyung, Kee-Sung;Kwon, Oh-Kyung;Choi, Dal-Soon;Choi, Ju-Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.4
    • /
    • pp.306-312
    • /
    • 2006
  • The objective of this study was to compare the reduction of residues in/on mini-tomato by washing methods and to evaluate the relation of reduction rates in different pesticides. Mini-tomato was sprayed with three commercial pesticides, oxadixyl, thiophanate-methyl and chlorothalonil, and harvested for washing test as 0, 5 and 7 days elapsed. The reduction rates of oxadixyl in/on mini-tomato were 61, 11 and 4%, those of thiophanate-methyl were 89, 89 and 79%, and in case of chlorothlaonil, reduction rates were 84, 84 and 88%, respectively When mini-tomato at 0 day and 5 days after spray was washed by 0.02% of $Sur-ten^{(R)}$ solution, its pesticide residues were reduced by 81 and 55% on oxadixyl, 95 and 91% on thiophanate-methyl, and 97 and 98% on chlorothlaonil. When three wettable powdered pesticides with the same recipe were sprayed, their reduction rates in/on mini-tomato by washing with water at 0, 5 and 7 days were 76, 66 and 43% on oxadixyl, 91, 83 and 82% on thiophanate-methyl, and 65, 68 and 82% on chlorothlaonil, suggesting that the washing effect may be dependent on the amounts of active ingredients and inert types of the pesticides used.

Factors Associated with the Stability of Two-part Mini-implants for Intermaxillary Fixation

  • Kim, Seong-Hun;Seo, Woon-Kyung;Lee, Won;Kim, In-Soo;Chung, Kyu-Rhim;Kook, Yoon-Ah
    • Journal of Korean Dental Science
    • /
    • v.2 no.2
    • /
    • pp.24-30
    • /
    • 2009
  • Two component orthodontic C-implants have been introduced as intermaxillary fixation (IMF) screws in cases of periodontal problems with bone loss, severely damaged teeth, or short roots. This retrospective research sought to investigate the complications and risk factors associated with the failure of two-part C-implants for IMF cases and to show the possible indications compared to one-component mini-implants. The study sample consisted of 46 randomly selected patients who had a total of 203 implants. Pearson chi-square tests of independence were used to test for associations among categorical variables. At least 19 of the total 203 implants failed (9.3%). There was no significant difference in implant failure due to gender, oral hygiene, and placement, although a significant difference due to soft tissue characteristics and root contact was observed. The two-component design of the mini-implant is reliable for difficult IMF cases. Note, however, that the factors influencing implant failure were found to be age, root damage, and condition of soft tissues.

  • PDF