• Title/Summary/Keyword: MIBK

Search Result 67, Processing Time 0.03 seconds

Delignification of Lignocellulosic Biomass with High-Boiling Point Solvent and Acidic Catalyst (고비점 용제와 산 촉매에 의한 목질 바이오매스의 탈리그닌)

  • Kim, Kang-Jae;Jung, Jin-Dong;Jung, Soo-Eun;Hong, Sung-Bum;Eom, Tae-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.48 no.1
    • /
    • pp.119-126
    • /
    • 2016
  • In this study, we separated the lignin from the wood by using the high boiling point solvent for developing more environmental friendly pulping method. High boiling point solvents as Ethers, glycols and ketones were used to remove the lignin in the pine wood meals. The Yield and lignin content of residual wood meals was reduced according to the input of the catalyst. Me-C, E-Ca, TEG and MIBK had the best delignification rate of 9 kinds of high-boiling point solvents. At the hydrolysis ratio of the selected solvents, The TEG was highest remain ratio of carbohydrates and the E-Ca was lowest remain ratio of lignin. And the Me-C was most excellent lignin hydrolysis ratio at the low catalyst. The selectivity of delignification of Me-C, E-Ca, TEG and MIBK solvents were 49.6, 49.9, 53.8 and 53.1%, respectively, and its values were similar to those of the commercial Kraft Pulp.

A study on electron beam lithography for 0.1$\mu\textrm{M}$ T-gate formation at P(MMA/MAA)/PMMA structure (PMMA/P(MMA/MAA) 구조에서 0.1$\mu\textrm{M}$ T-gate 형성을 위한 전자빔 리소그래피 공정에 관한 연구)

  • Choe, Sang-Su;Lee, Jin-Hui;Yu, Hyeong-Jun;Lee, Sang-Yun
    • Korean Journal of Materials Research
    • /
    • v.5 no.1
    • /
    • pp.96-103
    • /
    • 1995
  • This art~cle reports on the formation of T - Gate with O.1$\mu$m foot and 0.4$\mu$m head width at PMMA/P( MMA/MAA) resist structure using a 30KV electron beam lithography system. From the result of Monte Carlo simulation on PMMA/P( MMA/MAA)/GaAs, we obtain the dissipation energy ratio of forwardscattered electron and backscattered electron within 0.1$\mu$m scattering radius is 19.5 : 1 0.1$\mu$m T - gate has been formed with 30KV gaussian electron beam at a 440$\mu C/\textrm{cm}^2$ dosage. The gamma value of PMMA and P(MMA/MAA) at MIBK : IPA=l : 1 developer was 2.3. The overlay accuracy(3$\sigma$) from mix-andmatch of optical stepper and Ekeam lithography system for fabricating HEMT device is accomplished below 0.1$\mu$m.

  • PDF

Reactive Extraction of Organic Acid with Amine Extractant, I. (A Study on the Effects of Extractant and Solvent on the Degree of Extraction in Reactive Extraction of Organic Acid) (아민 추출제에 의한 유기산의 반응추출(I) (유기산의 반응추출시 추출도에 미치는 추출제 및 용매의 영향에 관한 연구))

  • Ryu, Oon-Hyung;Lee, Han-Seob;Yoo, Chul-Hwi;Kim, Yong-Yeul;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.203-213
    • /
    • 1996
  • In physical and reactive extraction system using equilibrium extraction equipment, the effects of extractants, concentration of extractant, and solvent on the degree of extraction were investigated. The organic acids used were acrylic acid and metacrylic acid. Extractants were n-octylamine(OA), di-n-octylamine(DOA), tri-n-octylamine(TOA) and tri-octylmetyl ammonium chloride(TOMAC ; Aliquat 336). We found that the degree of extraction for reactive extraction was 2~9 times than that for physical extraction and that effect of extractants on the degree of extraction of organic acid was the order of OA

  • PDF

A Study on Reactive Extraction of Citric Acid in Citric-acetic-lactic Acid System (구연산-초산-유산계에서 구연산의 반응추출에 관한 연구)

  • Lee, Han-Seob;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.5 no.1
    • /
    • pp.90-98
    • /
    • 1994
  • For elucidation of various parameters' effects on the reactive extraction of citric acids, citric-acetic-lactic acid system with various carriers, diluents, and modifiers were investigated. Carries used were secondary amines, tertiary amines, and solvation extract. Dileunts were n-butylacetate, methoisobutylketon(MIBK), kerosine, and xylene. Modifiers were TBP and isodecanol. The effects of temperature and pH in aquous phase were studied, and equilibrium constants for the reactive extraction were obtained. The re-extraction was performed by alkali solutions such as NaOH, $Na_2CO_3$, and $K_2HPO_4$. Based on the experiment Di-isotridecylamine(secondary amine ) gave higher degree of extraction and more selective than other extractants tested for the extraction of citric acid. N-butylacetate and TBP showed heigher performance for a diluent and modifier, repetitively. The degree of extraction was getting better with decreasing the pH in the aquous phase and the temperature of extraction system. The degree of re-extraction was getting higher with decreasing basicity in the stripping phase and the system temperature, and with increasing the concentration of alkali solution.

  • PDF

Studies on Solvent Sublation of Trace Heavy Metals by Continuous Flow System as Ternary Complexes of 1,10-Phenanthroline and Thiocyanate Ion

  • Kim, Young-Sang;Choi, Yoon-Seok;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1775-1780
    • /
    • 2003
  • A continuous flow system has been developed to determine trace Cu(II), Mn(II), Ni(II) and Zn(II) in a large volume of water samples by a solvent sublation technique. The mixed solution of 1,10-phenanthroline(phen) and thiocyanate ion was used as ligands for the formation of their ternary complexes. The continuous system was constructed in this laboratory with a peristaltic pump, a mini shaker, three mixing bottles and a flotation cell by connecting each part with a polyethylene tube. The flotation conditions such as the flow rate of sample solution and the injection rates of ligand, buffer and surfactant solutions have been investigated to obtain the best sublation efficiencies. Each solution flowed into the flotation cell through each polyethylene tube by the peristaltic pumps. The ternary complexes were floated and extracted into MIBK in a flotation cell of 2 L by bubbling a nitrogen gas. The absorbances of extracted analytes in MIBK were directly measured by graphite furnace-AAS. The concentrations of 1,10-phenanthroline and thiocyanate ion were $2.6\;{\times}\;10^{-3}$ M and $2.3\;{\times}\;10^{-2}$ M in the mixed solution, respectively. The pH of sample solution was adjusted to 5.0 with a buffer solution and 1%(m/v) sodium lauryl sulphate solution was added as a surfactant to support the effective flotation of the complexes. The $N_2$ gas was bubbled at 30 mL/min for 90 minutes for 20 L of sample. Reproducible results of less than 10% RSD and recoveries of 80-120% could be obtained in real samples.

Determination of Zinc and Lead in Water Samples by Solvent Sublation Using Ion Pairing of Metal-Naphthoate Complexes and Tetra-n-butylammonium Ion

  • Kim, Yeong Sang;Choe, Yun Seok;Lee, Won;Lee, Yong Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.821-826
    • /
    • 2001
  • Solvent sublation has been studied for the separation and determination of trace Zn(Ⅱ) and Pb(Ⅱ) in water samples. A synergy producing method was utilized to improve the efficiency of extraction in the sublation using an ion-pair of metal-naphth oate {M-(Nph)3- } complexes and tetra-n-butylammonium (TBA+ ) ion. After the M-(Nph)3- complexes were formed by adding 1-naphthoic acid to the sample solution, tetra-n-butylammonium bromide was added in the solution to form the ion-pair. And sodium lauryl sulfate (SLS) was added to make the ion-pair hydrophobic. The ion-pairs of the metal complexes were floated and extracted into methylisobutyl ketone (MIBK) from the aqueous solution by bubbling with nitrogen gas in a flotation cell. Metal ions in MIBK solution were measured by graphite furnace-AAS. Experimental conditions were optimized as follow so. After the pH of a 1.0 L water sample was adjusted to 5.0, 6.0 mL of 0.1 M 1-HNph and 10 mL of 0.03 M TBA-bromide were added to the sample to form ion-pairs, and 2.0 mL of 0.2%(w/v) SLS was added to make the ion-pairs hydrophobic. The solution was bubbled with 30 mL/min N2 gas for 5 minutes in a flotation cell. Linear calibration curves were obtained for the determination of Zn(Ⅱ) and Pb(Ⅱ) in several water samples. Reproducible results of showing a relative standard deviation of < 10% and recoveries of 80-100% could be obtained.

Development of pervaporation simulator (투과증발 시스템 모사기 개발)

  • 장재화;유제강;안승호;이규현
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1996.10a
    • /
    • pp.88-89
    • /
    • 1996
  • 투과증발 시스템은 막 분리 기술의 일종으로 액체 혼합물 중의 한 성분에 대해 친화적인 비다공성 막을 사용하여 그 성분을 선택적으로 투과시켜 혼합물을 분리하는 기술이다. 투과증발 시스템에서는 Feed가 비교적 높은 온도에서 액상 형태로 막의 Feed side에 공급되어 막을 투과한 물질(Permeate)은 Permeate side에서 기화된 후 냉각기로부터 공급되는 Cold brine에 의하여 응축되며, 이는 투과증발막 투과 구동력이 각 성분의 증기압 차이기 때문에 이를 크게 유지하기 위함이다. 현재 투과증발 시스템이 상업적으로 적용되고 있는 공정은 유기물 탈수 공정으로, 이 공정에서는 물에 대한 용해도 및 투과 속도가 우수한 친수성 막을 이용하여 유기물과 물의 혼합물로부터 물을 제거하여 유기물을 농축하며, 대표적인 유기물은 에탄올, Isopropyl alcohol(IPA), 아세톤, MIBK, Ethyl acetate, THF 등의 중성 유기물이다.

  • PDF

Submicron Patterning in Electron Beam Lithography using Trilayer Resist (삼층감광막구조를 이용한 미세패턴의 전자빔 묘화)

  • 배용철;서태원;전국진
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.10
    • /
    • pp.101-107
    • /
    • 1994
  • The PMMA/Ge/AZ trilayer resist decreased proximity effect of backscattering electrons and corrected pattern distoration in order to from deep submicron patterns. In the experiment, the prosiemity effect is decreased by 11% and 30% for the case of 0.9$\mu$m and 1.7$\mu$m AZ, respectively, in trilayer resist compared to monolyer resist. also, the EID of 240$\AA$ Ge film is smaller than that of 500$\AA$ film by 365. 0.1$\mu$m line/space was formed in the 2000$\AA$ PMMA layer with the condition of dose 330${\mu}C/cm^{2}$ and of 150sec of develop time in MIBK : IPA (1:3) developer.

  • PDF

Studies on Solvent Extraction Using Salphen for Separative Determination of Trace Fe(II) and Fe(III) in Water Samples

  • Kim, Eun-Jook;Kim, Young-Sang;Choi, Jong-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.99-103
    • /
    • 2008
  • Solvent extraction using salphen as a ligand has been investigated for the selective separation and determination of trace Fe(II) and Fe(III). A salphen ligand was synthesized, and solvent extraction variables, such as solution pH, the concentration of salphen, the type of organic solvent, auxiliary agents, oxidants and the effect of interference were optimized. Salphen is stable at pH 3-4, and Fe(III)-salphen complexes can be selectively extracted into an MIBK(4-methyl-2-pentanone) phase from an aqueous solution within this pH range. For the determination of the total amount of iron in 100 mL of aqueous solution, Fe(II) ions were completely oxidized using 0.05 mL of 3.5% H2O2 without side reactions. To evaluate its applicability, the proposed method was applied to determine trace Fe(II) and Fe(III) in several kinds of water samples. Reproducible results were obtained with RSD of less than 3.0%, and the recoveries for this reliability were obtained with 91-112%.

Fabrication of $0.25 \mu\textrm{m}$ P-HEMT for X-band Low Noise Amplifier (X-밴드 저잡음 증폭기용 $0.25 \mu\textrm{m}$ T-형 게이트 P-HEMT 제작)

  • 이강승;정윤하
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.17-20
    • /
    • 2000
  • We have enhanced the yield of 0.25 ${\mu}{\textrm}{m}$ T-gate $Al_{0.25}$G $a_{0.75}$As/I $n_{0.2}$G $a_{0.8}$As P-HEMT using three-layer E-beam lithography process and selective etching process. The three-layer resist structure (PMMA/copolymer/ PMMA=2000 $\AA$/3000 $\AA$/2000 $\AA$) and three developers (Benzene:IPA=1:1,Methanol:IPA =1:1,MIBK:IPA=1:3) were used for fabrication of a wide-head T-gate by the conventional double E-beam exposure technology. Also 1 wt% citric acid: $H_2O$$_2$:N $H_{4}$OH(200m1:4ml:2.2ml) solution were used for uniform gate recess. The etching selectivity of GaAs over $Al_{0.25}$G $a_{0.75}$As is measured to be 80. So these P-HEMT processes can be used in X-band MMIC LNA fabrication.ion.ion.ion.

  • PDF