• Title/Summary/Keyword: ME test

Search Result 469, Processing Time 0.03 seconds

A Semantic Video Object Tracking Algorithm Using Contour Refinement (윤곽선 재조정을 통한 의미 있는 객체 추적 알고리즘)

  • Lim, Jung-Eun;Yi, Jae-Youn;Ra, Jong-Beom
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.6
    • /
    • pp.1-8
    • /
    • 2000
  • This paper describes an algorithm for semantic video object tracking using semi automatic method. In the semi automatic method, a user specifies an object of interest at the first frame and then the specified object is to be tracked in the remaining frames. The proposed algorithm consists of three steps: object boundary projection, uncertain area extraction, and boundary refinement. The object boundary is projected from the previous frame to the current frame using the motion estimation. And uncertain areas are extracted via two modules: Me error-test and color similarity test. Then, from extracted uncertain areas, the exact object boundary is obtained by boundary refinement. The simulation results show that the proposed video object extraction method provides efficient tracking results for various video sequences compared to the previous methods.

  • PDF

Isolation of Anti-oxidant from Domestic Crataegus pinnatifida Bunge Leaves (국산 산사나무 잎으로부터 항산화 활성성분의 분리)

  • Kang, In-Ho;Cha, Ja-Hyun;Han, Jeong-Hun;Lee, Seong-Wan;Kim, Hon-Jin;Kwon, Suck-Hyung;Ham, In-Hye;Hwang, Bo-Sik;Whang, Wan-Kyunn
    • Korean Journal of Pharmacognosy
    • /
    • v.36 no.2 s.141
    • /
    • pp.121-128
    • /
    • 2005
  • In order to find the antioxidative compounds, fractionation of the MeOH extract of the leaves of Crataegus pinnatifida guided by DPPH scavenging test furnished seven phenolic compounds, $quercetin-3-O-{\alpha}-L-rhamnopyranosyl(1{\rightarrow}6)-{\beta}-D-glucopyranoside$ (1), myricetin-3-O-rhamnose (2), $quercetin-3-O-{\alpha}-L-rhamnopyranosyl-(1{\rightarrow}6)-{\beta}-D-galctopyranoside$ (3), $quercetin-3-O-{\beta}-D-galactopyranoside$ (4), quercetin (5), $apigenin-8-C-{\beta}-L-rhamnopyranosyl-(1{\rightarrow}6)-{\beta}-D-glucopyranoside$ (2'-O-rhamnosylvitexin) (6) and (-)-epicatechin (7). All of isolated compounds showed the significant antioxidative effect on DPPH free radical scavenging test and TBARS assay.

Synthesis and Properties of High Voltage Silicone Rubber by Platinum-based Flame Retardant

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.283-292
    • /
    • 2006
  • So that high-strength and electrical properties apply by excellent high voltage insulator electricity material, ATH content and platinum-based flame retardant that influence in flame retardant and tracking characteristic among composite of silicone rubber studied mechanical strength and influence getting to electrical properties. Composition of ${\alpha}$, ${\omega}-vinyl$ poly (dimethyl-methylphenyl) siloxane(VPMPS) of a polymer quantity made doing mole of D4, $D3^{Me,Ph}$ and VMS by 1000:15:0.2 mole ratio and uses basic catalyst tetramethylammonium silanolate(TMAS) and do opening equilibrium polymerization to be used to main polymer for high voltage insulation insulator. Control ATH content and content of platinum-based flame retardant and made high voltage insulation silicone rubber. Measured mechanical strength of making silicone rubber using UTM, and tracking characteristic according to standard of IEC 60587, flame retardant test studied effect that flame retardant characteristic gets in tracking characteristic, measuring according to UL94V method of test.

A Study on Health Behaviors, Health Status and Anxiety about Aging for the Elderly - Focused on the Elderly in Senior Center- (경로당 이용노인의 노화에 대한 불안감, 지각된 건강상태와 건강증진 행위실천)

  • Shin, Yoo-Sun;Kim, Eun-Ha
    • Research in Community and Public Health Nursing
    • /
    • v.20 no.2
    • /
    • pp.179-188
    • /
    • 2009
  • This study is conducted to survey and examine the relationships among anxiety about aging, perceived health status and health promoting behaviors in the elderly, and to provide basic data for health promoting interventions that would improve their successful aging. Me1hods: Data in this study was collected from 333 elderly participants living in Susan. Descriptive statistics, t-test or ANOVA with Scheffe's test, Pearson's correlation coefficients and stepwise multiple regression were used for data analysis. Results: The major findings of this study were as follows. 1) The mean score of anxiety about aging was 2.67 $\pm$ 0.30, perceived health status 2.46 $\pm$ 0.37, and health promoting behavior 2.77 $\pm$ 0.21.2) There was a positive correlation between health promoting behavior and perceived health status (r = 267, P= .000). There was a negative correlation between anxiety about aging and health promoting behavior (r = -.163, P=.003). 3) Health-promoting behavior was significantly associated with perceived health and anxiety about aging, which explained 20.9% of variance in health-promoting behavior. Conclusion: In order to promote perceived health status and to decrease anxiety about aging in the elderly, it is necessary to develop supporting interventions to decrease anxiety about aging

  • PDF

Corrosion Behaviors of Neutron-Irradiated Reactor Pressure Vessel Steels with Various Nickel and Chromium Contents (Ni과 Cr 함량이 다른 원자로 압력용기용 강의 중성자 조사 후 내식성 평가)

  • Choi, Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.52 no.6
    • /
    • pp.293-297
    • /
    • 2019
  • Quasi-nano-hardness and corrosion behaviors of neutron-irradiated reactor pressure vessel (RPV) steels such as 15Ch2MFA (Ni<0.4, 2.520 n/㎠ (En>1.0 MeV) for 32 days. Quasi-nano-hardnesses of the 15Ch2MFA and 15Cr2NHFA steels were 183.8 and 179.8 Hv, respectively. Their corrosion rates and corrosion potentials were 2.4×10-4Acm-2, -515.9 mVSHE and 6.8×10-4 Acm-2, -523.6 mVSHE in NACE standard TM0284-96 solution at room temperature, respectively. 15Ch2MFA steel showed better quasi-nano-hardness and corrosion resistance than 15Cr2NHFA steel in this test condition.

DESIGN AND FABRICATION OF THE BEAM POSITION MONITOR FOR THE PEFP LINAC

  • Kwon, Hyeok-Jung;Kim, Han-Sung;Seol, Kyung-Tae;Ryu, Jin-Yeong;Jang, Ji-Ho;Cho, Yong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.523-528
    • /
    • 2013
  • The beam position monitor (BPM) is an essential component for the PEFP 100-MeV linac's commissioning. A prototype stripline-type linac BPM was designedfor this purpose. The electrode aperture is 20 mm in diameter, and the electrode is 25 mm long, so it can be installed between Drift Tube Linac (DTL)101 and DTL102, which is the shortest distance. One end of the electrode is connected to the Sub Miniature Type A (SMA) feed through for signal measurement, and the other end is terminated as a short. The signal amplitude of the fundamental component was calculated and compared with that of the second harmonic component. The designed BPM was fabricated and a low-power RF test was conducted. In this paper, the design, fabrication and low power test of the BPM for the PEFP linac are presented.

The Effects of Basic Life Support Education on CPR Knowledge and Attitude of Undergraduates (기본 심폐소생술 교육이 대학생의 심폐소생술에 대한 지식과 태도에 미치는 효과)

  • Yoon, Me-Ok
    • Journal of the Korean Society of School Health
    • /
    • v.24 no.1
    • /
    • pp.1-11
    • /
    • 2011
  • Purpose: This study is a non-equivalent control group pre-post design, which attempted to observe the effects of Basic Life Support Education on undergraduate students' CPR Knowledge and Attitude. Methods: The subjects were 96 undergraduates in Jeonbuk. They were divided into two groups: an experimental group of 46 students and a control group of 50 students. The BLS education was given by three BLS instructors certified by the American Heart Association using a DVD. Data were collected from October 20 to November 15, 2010 and analyzed, using the ${\chi}^2$ test, t-test, and ANCOVA. Results: There were significant differences between the experimental group and the control group in the levels of CPR Knowledge and Attitude. The 1st hypothesis, that the CPR knowledge scores for the experimental group would be higher than those of the control group, was supported (F=157.58, p=.000). The 2nd hypothesis, that the CPR attitude scores for the experimental group would be higher than those of the control group, was supported (F=23.78, p=.000). Conclusion: This study showed that BLS education had a positive influence on undergraduate students' knowledge and attitudes toward CPR. We expect that BLS education will contribute to spreading knowledge of CPR and reducing mortality among heart attack victims, and we can see from this study how CPR training in combination with theory and clinical practice develops knowledge and practical ability.

Development of a DDA+PGA-combined non-destructive active interrogation system in "Active-N"

  • Kazuyoshi Furutaka;Akira Ohzu;Yosuke Toh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4002-4018
    • /
    • 2023
  • An integrated neutron interrogation system has been developed for non-destructive assay of highly-radioactive special nuclear materials, to accumulate knowledge of the method through developing and using it. The system combines a differential die-away (DDA) measurement system for the quantification of nuclear materials and a prompt gamma-ray analysis (PGA) system for the detection of neutron poisons which disturb the DDA measurements; a common D-T neutron generator is used. A special care has been taken for the selection of materials to reduce the background gamma rays produced by the interrogation neutrons. A series of measurements were performed to test the basic performance of the system. The results show that the DDA system can quantify plutonium of as small as 20 mg and it is not affected by intense neutron background up to 1.57 × 107 s-1 and gamma ray of 4.43 × 1010 s-1. The gamma-ray background counting rate at the PGA detector was reduced down to 3.9 × 103 s-1 even with the use of the D-T neutron generator. The test measurements show that the PGA system is capable of detecting 0.783 g of boron and about 86.8 g of gadolinium in 30 min.

Effects of pine Bark Spent Liquor Prepared by Alkaline Sulfite-Anthraquinone Cooking as a Pellet Binder on Pellet Durability and Performance of Broiler Chicks or Laying Hens (소나무 수피 알칼리성 아황산염-안트라퀴논 증해폐액이 사료결착제로서 펠렛 내구성과 가금의 생산성에 미치는 영향)

  • K. S. Ryu;H. L. Li;S. P. Mun;H. J. Song
    • Korean Journal of Poultry Science
    • /
    • v.28 no.2
    • /
    • pp.91-98
    • /
    • 2001
  • Three experiments were conducted to investigate the Pine Bark Spent Liquor (PBSL) inclusion, prepared by alkaline sulfite-anthraquinone cooking, on Pellet durability index (PDI) of practical diets and performance of broiler chicks and laying hens. Fourteen treatments with four replications were assigned for PDI test in Experiment 1. Control, 10% Wheat(W10), 20% Wheat(W20), 0.25, 0.50, 1.00, 2.00 and 3.00% PBSL, 0.1, 0.2% commercial pellet binder A(CPB A) or B(CPB B), W10 plus 0.1% CPB A or B were used for PDI test. PDI was measured by PDI tester (Oriental Motors, Japan). The control diet was based on corn and soybean meal with no wheat or pellet binders inclusion. The PDI of the PBSL or other commercial pellet binder treatments were significantly higher than control groups(P<0.05). It was shown 95.9, 95.9, 95.8, and 95.7 in W10, 0.5% PBSL, 0.2% CPB A or B treatments, respectively. Thus, those treatments were applied to Experiments 2 and 3. In experiment 2, 200 male broiler chicks (Cobb$\times$Cobb) were allocated to the control, W10, PBSL 0.5%, 0.2% CPB A and B with four replications. Starter diets contained 3,169, 3,149 kcal/kg ME and 21% CP, and finisher diets were fed at the level of 3,192, 3,172 kcal/kg ME and 19W% CP. Weight gain, feed intake, feed conversion ratio (FCR) were weekly measured for 5 wk and the number of intestinal anaerobes were examined at the end of experiment. The weight gain of chicks fed PBSL was not significantly greater than control groups, but was significant different compared to that of W10 or 0.2% CPB A treatments (P<0.05). FCR of chicks treated with PBSL or other pellet binders tended to improve compared to that of control.

  • PDF

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF