• Title/Summary/Keyword: MDCT images

Search Result 54, Processing Time 0.022 seconds

Robust Pelvic Coordinate System Determination for Pose Changes in Multidetector-row Computed Tomography Images

  • Kobashi, Syoji;Fujimoto, Satoshi;Nishiyama, Takayuki;Kanzaki, Noriyuki;Fujishiro, Takaaki;Shibanuma, Nao;Kuramoto, Kei;Kurosaka, Masahiro;Hata, Yutaka
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • For developing navigation system of total hip arthroplasty (THA) and evaluating hip joint kinematics, 3-D pose position of the femur and acetabulum in the pelvic coordinate system has been quantified. The pelvic coordinate system is determined by manually indicating pelvic landmarks in multidetector-row computed tomography (MDCT) images. It includes intra- and inter-observer variability, and may result in a variability of THA operation or diagnosis. To reduce the variability of pelvic coordinate system determination, this paper proposes an automated method in MDCT images. The proposed method determines pelvic coordinate system automatically by detecting pelvic landmarks on anterior pelvic plane (APP) from MDCT images. The method calibrates pelvic pose by using silhouette images to suppress the affect of pelvic pose change. As a result of comparing with manual determination, the proposed method determined the coordinate system with a mean displacement of $2.6\;{\pm}\;1.6$ mm and a mean angle error of $0.78\;{\pm}\;0.34$ deg on 5 THA subjects. For changes of pelvic pose position within 10 deg, standard deviation of displacement was 3.7 mm, and of pose was 1.28 deg. We confirmed the proposed method was robust for pelvic pose changes.

MDCT Angiography of the Subclavian Artery Thrombosis of the 3D Findings (쇄골하동맥 혈전증에서의 MDCT 혈관조영술의 3D 영상)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.813-819
    • /
    • 2018
  • To demonstrate the 3D usefulness of MDCT, a 73-year-old male patient with subclavian thrombosis was obtained 3D images of maximum intensity projection (MIP), volume rendering, and multiplanar reformation (MPR) to clearly detect and locate the subclavian artery. The data will be provided to the patient for diagnosis and treatment. The scan data were acquired as 3D CT images MIP, volume rendering, curved MPR, and virtual endoscopy images. In the 3D program, the ascending aorta was measured as 364.28 HU, the left carotid artery was 413.77 HU, and the left subclavian artery was 15.72 HU. MIP coronal image shows the closure of the subclavian artery in the left side. Three-dimensional volume images were obtained with 100% permeability and 87-1265 HU. The coronal curved MPR and sagittal curved MPR images show the closure of the subclavian artery due to thrombus using 3D image processing. In the case of subclavian arterial occlusion due to thrombosis, the patient is scanned with MDCT and 3D image processing can be used to confirm occlusion of subclavian artery.

Intra- and interobserver agreement of computed tomography in assessment of the mandibular condyle

  • Cho, Bong-Hae;Jung, Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.191-195
    • /
    • 2007
  • Purpose: To study the intra- and interobserver agreement of multidetector row computed tomography (MDCT) in interpretation of degenerative changes of the mandibular condyle. Materials and Methods: Five observers independently evaluated one hundred temporomandibular joint MDCT images for signs of osteophytes, erosion, sclerosis and flattening. The intra- and interobserver agreements were calculated by using Kappa statistics. Results: The intraobserver agreement was substantial for erosion (k=0.75), flattening (k=0.74) and sclerosis (k=0.72) and almost perfect for osteophytes (k=0.84). The interobserver agreement was fair for flattening (k=0.39), moderate for erosion (k=0.58) and sclerosis (k=0.48) and substantial for osteophytes (k=0.75). Conclusion: This study shows that we can expect good agreement for the presence of osteophytes, but not for flattening in the interpretation of MDCT images of the condyle.

  • PDF

Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning (3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가)

  • Chung, Gi-Chung;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

Detection of Lung Nodule on Temporal Subtraction Images Based on Artificial Neural Network

  • Tokisa, Takumi;Miyake, Noriaki;Maeda, Shinya;Kim, Hyoung-Seop;Tan, Joo Kooi;Ishikawa, Seiji;Murakami, Seiichi;Aoki, Takatoshi
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.12 no.2
    • /
    • pp.137-142
    • /
    • 2012
  • The temporal subtraction technique as one of computer aided diagnosis has been introduced in medical fields to enhance the interval changes such as formation of new lesions and changes in existing abnormalities on deference image. With the temporal subtraction technique radiologists can easily detect lung nodules on visual screening. Until now, two-dimensional temporal subtraction imaging technique has been introduced for the clinical test. We have developed new temporal subtraction method to remove the subtraction artifacts which is caused by mis-registration on temporal subtraction images of lungs on MDCT images. In this paper, we propose a new computer aided diagnosis scheme for automatic enhancing the lung nodules from the temporal subtraction of thoracic MDCT images. At first, the candidates regions included nodules are detected by the multiple threshold technique in terms of the pixel value on the temporal subtraction images. Then, a rule-base method and artificial neural networks is utilized to remove the false positives of nodule candidates which is obtained temporal subtraction images. We have applied our detection of lung nodules to 30 thoracic MDCT image sets including lung nodules. With the detection method, satisfactory experimental results are obtained. Some experimental results are shown with discussion.

Utility of Lateral Circumflex Femoral Artery Perforator's 3D Image with MD-CT (MD-CT로 얻은 가쪽넙다리휘돌이 관통동맥 3D 영상의 유용성)

  • Park, Soo Ho;Shim, Jeong Su;Lee, Sang Kon;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.379-384
    • /
    • 2008
  • Purpose: Currently, using perforator artery flaps especially anterolateral thigh flaps are widely used for reconstruction of extremities, head and neck. Obtaining a precise anatomical picture prior to operation will translate to a more accurate, efficient and safe procedure. Authors used 3D-image work up via 64-slice MDCT to make a more precise preoperative plan. Methods: A total of 10 patients underwent soft tissue reconstruction with anterolateral thigh flap from December 2006 to December 2007. The 64-Channel MDCT (LightSpeed VCT, GE, USA) was used and 3D images were reconstructed. Findings from MDCT were applied to the preoperative planning and confirmed with intraoperative findings. Results: The average number of perforator arteries from lateral circumflex femoral artery was 2. The average lengths of vascular pedicle from the origin of lateral circumflex femoral artery to the first and second perforator artery were 11.0 cm and 20.0 cm, respectively. The average diameter of the pedicle artery was 2.2 mm. The locations of the perforator arteries were mapped and localized on the body surface based on the MDCT result. These were confirmed through direct visualization intraoperatively. Conclusion: MDCT has an advantage of obtaining accurate images of the general anatomy and even fine structures like perforator arteries. By using this state-of-the-art diagnostic imaging technique, it is now possible to make an operative plan safely and easily.

Radiation Dose Reducing Effect during the AEC System in the Chest and Abdomen of the MDCT Scanning (흉부 및 복부에서 AEC 적용에 따른 MDCT의 선량 감소 효과)

  • Lee, Jong-Seok;Kweon, Dae-Cheol;You, Beong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.3
    • /
    • pp.225-231
    • /
    • 2009
  • The purpose of the current study was to compare radiation dose of 64MDCT performed with automatic exposure control (AEC) with manual selection fixed tube current. We evaluated the CT scans of phantom of the chest and abdomen using the fixed tube current and AEC technique. Objective image noise shown as the standard deviation of CT value in Hounsfield units was measured on the obtained images. Compared with fixed tube current, AEC resulted in reduction of the chest and abdomen in the CTDIvol (35.2%, 5.9%) and DLP (49.3%, 3.2%). Compared with manually selected fixed tube current, AEC resulted in reduced radiation dose at MDCT study of chest and abdomen.

Detection for Contrast Media Extravasation using Bolus Tracking Systems of CT (CT Bolus Tracking System을 이용한 조영제의 혈관외유출 검출)

  • Kweon, Dae-Cheol;Lee, Yong-Gu
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.137-142
    • /
    • 2016
  • When injecting intravenously of CT inspection, the effusion of the contrast meium can induce the tissue damage with the blood vessel outside. We detect extravasation which is generated in the course where we inject the contrast medium into the blood vessel. And we use the bolus tracking system for the detection of that. By using MPR and VR images, moreover we detected the extravasation in order to prevent the tissue damage. In order to detect the effusion of the contrast medium, we used 16-MDCT and 64-MDCT. Three dimensional images about the outflow of the blood vessel can provide the treatment information which is important in the patient treatment. Moreover we applied the image processing technique in order to improve sharpness between contrast media and organization. And sharpness and contrast was improved.

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

  • Shokri, Abbas;Eskandarloo, Amir;Noruzi-Gangachin, Maruf;Khajeh, Samira
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.58-67
    • /
    • 2015
  • Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.

The Effective Image Diagnosis Using Curved MPR from MDCT (MDCT에서 Curved MPR을 이용한 효과적인 영상진단)

  • Song, Jong-Nam;Jang, Yeong-Ill
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.139-143
    • /
    • 2010
  • Two-dimensional(2D) images like Multi Planar Reconstruction(MPR) Image or Maximum Intensity Projection(MIP) were used for the purpose of diagnosis, but MPR image's quality were limited due to its superior limit of Z-axis ability to produce permitted radiation exposure virtuous in the permitted time limit from the existing Spiral CT. However, in company with the development of the Multi Detector Computed Tomography(MDCT), we were able to get the Data with the equal amount of Voxel, also get varied reconstructions as in the aspect of our needs. This present study propose a reconstruction technique which is to extract a field using Region of interest(ROI) segmentation method for improvement of the quality of the medical image and after that reconstruct the concerned part using the four-directed symmetry method of the oval, than using the reconstructed data, reorganize the image by using the Curved MPR method. If current proposed method is used, it is highly effective because of its ability to accurately display the disease concerned part, which will reduce the decoding time and also effectively provide information based on the accuracy of the decode.

  • PDF