• Title/Summary/Keyword: M2M device

Search Result 2,303, Processing Time 0.029 seconds

A Basic Study on Particle Distribution Characteristics of Rotary Mist Spraying Device (회전형 미세입자 분무장치의 입자 분포 특성에 관한 기초 연구)

  • Ryou, Young Sun;Jang, Jae Kyung;Kim, Hyung Kweon;Kim, Young Hwa;Lee, Tae Suk;Oh, Sung Sik;Jin, Byung Ok;Oh, Gyoung Min;Kang, Tae Kyoung
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.454-460
    • /
    • 2019
  • The purpose of this study is to analyze the distribution characteristics of mist spray particle size by devising a rotary mist spraying device to develop the evaporative salt water desalination system. The rotary mist spraying device was consisted of a BLDC sirocco fan, a spinning fan, a fan fixed shaft and a salt water supply device etc. In this study we analyzed the characteristics of spray particle size and distribution according to the variation of sirocco fan surface roughness(Ra, ${\mu}m$), revolutions(rpm) and salt water flow rate(mL/min). When sirocco fan surface roughness(Ra) was in the range of $0.27{\sim}7.65{\mu}m$, the spray particle size was $0.117{\sim}1.360{\mu}m$. And then more than 90% of spray particles were found to be less than $0.50{\mu}m$. When sirocco fan surface roughness(Ra) was in the range of $12.70{\sim}22.84{\mu}m$, the spray particle size was $2.51{\sim}184.79{\mu}m$ and more than 98% of spray particles were found to be less than $13.59{\mu}m$. To analyze the effect of fan rotation speed on the size and distribution of spray particles, when surface roughness Ra was fixed $0.27{\mu}m$ and fan rotation speed and salt water flow rate was respectively changed at 3,800~5,600 rpm and 2.77~8.28 mL/min, spray particle size was $0.314{\sim}0.541{\mu}m$. And when salt water flow rate was 9.74 mL/min and fan rotation speed was 3,800~5,200 rpm, spray particle size was in the range of $29.29{\sim}341.46{\mu}m$ and in case of 5,600 rpm more than 98.23% of spray particles were in the range of $2.51{\sim}13.59{\mu}m$.

Effects of Various Laser Wavelengths and Power Densities on the Ocular Damage in Pigmented Rats

  • Chung, Phil-Sang;Shin, Jang-In;Chang, Moo-Hwan;Chang, So-Young;Kang, Jung-Wook;Hwang, Hee-Jun;Ahn, Jin-Chul
    • Biomedical Science Letters
    • /
    • v.14 no.3
    • /
    • pp.173-178
    • /
    • 2008
  • With the widespread use of laser in medical and industrial settings, the incidence of laser injury to the ocular continues to grow among workers involved in handling lasers. The aim of this study is to compare ocular damages after irradiation with various laser wavelengths and power density. Ocular of pigmented rats was irradiated with $CO_2$ laser, 1064 nm Nd:YAG laser, and 532 nm diode laser. We observed damage of cornea, lens, and retina using slit lamp microscope and funduscopy. H&E staining of histopathology were applied to study the specimens. The higher exposure ($200mW/cm^2$, 10 sec) with $CO_2$ laser resulted in severe damage at the cornea. For the 1064 nm Nd:YAG laser, the higher exposure than $10mW/cm^2$ (10 sec) resulted in damage at the cornea and lens. Further, with the 532 nm diode laser, retinal lesions were induced when $10mW/cm^2$ (0.25 sec) was delivered to the eye. Theses results suggest that the ocular damages are different from various laser wavelength and power density.

  • PDF

Planar-type Sensor for Measuring the Time-varying Electric Fields (시변전장 측정용 평판형 센서)

  • Lee, Bok-Hee;Kil, Gyung-Suk
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.15-20
    • /
    • 1995
  • This paper deals with the planar-type sensor which can measure the time-varying electric fields. To make an electric field measurement system having a wide bandwidth, a planar-type sensor is proposed. The theoretical principle and design rule of the measuring device are introduced, and also the calibration and application investigations are carried out. From the calibration experiments, the frequency bandwidth of the electric field measurement device ranges from 160 [Hz] to 25 [MHz] and the sensitivity of the sensor is 1.2 [mV/V/m]. As the application experiments, the electric fields caused by the impulse and oscillating transient voltage in high voltage laboratory are measured by the proposed device, and the results are excellent.

  • PDF

High-Performance Optical Gating in Junction Device based on Vanadium Dioxide Thin Film Grown by Sol-Gel Method

  • Lee, Yong-Wook;Kim, Eung-Soo;Shin, Bo-Sung;Lee, Sang-Mae
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.784-788
    • /
    • 2012
  • In this paper, a high-performance optical gating in a junction device based on a vanadium dioxide dioxide ($VO_2$) thin film grown by a sol-gel method was experimentally demonstrated by directly illuminating the $VO_2$ film of the device with an infrared light at ~1554.6 nm. The threshold voltage of the fabricated device could be tuned by ~76.8 % at an illumination power of ~39.8 mW resulting in a tuning efficiency of ~1.930 %/mW, which was ~4.9 times as large as that obtained in the previous device fabricated using the $VO_2$ thin film deposited by a pulsed laser deposition method. The rising and falling times of the optical gating operation were measured as ~50 ms and ~200 ms, respectively, which were ~20 times as rapid as those obtained in the previous device.

Portable Amperometric Glucose Detection based on NiS/CuS Nanorods Integrated with a Smartphone Device

  • Heyu Zhao;Kaige Qu;Haoyong Yin;Ling Wang;Yifan Zheng;Shumin Zhao;Shengji Wu
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.252-261
    • /
    • 2023
  • Glucose detection is particularly important for clinical diagnosis and personal prevention and control. Herein, the smartphone-based amperometric glucose sensors were constructed using the NiS/CuS nanorods (NRs) as sensing electrodes. The NiS/CuS NRs were prepared through a facile hydrothermal process accompanied by the subsequent vulcanization treatment. The morphological and structural properties of NiS/CuS NRs were characterized with SEM, EDS, XRD, and XPS. Electrochemical measurements including cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy display that NiS/CuS NRs can act as highly efficient electrocatalyst for glucose detection. The NiS/CuS NRs electrodes present a wide detection range of 1-8000 µM for glucose sensing with the sensitivity of 956.38 µA·mM-1·cm-2. The detection limit was 0.35 µM (S/N=3). When employed in smartphone-based glucose sensing device, they also display a high sensitivity of 738.09 µA·mM-1·cm-2 and low detection limit of 1.67 µM. Moreover, the smartphone-based glucose sensing device also presents favorable feasibility in determination of glucose in serum samples with the recoveries ranging between 99.5 and 105.8%. The results may provide a promising viewpoint to design other new portable glucose sensors.

A Study on Smart Soil Resistance Measuring Device for Safety Characterized Ground Design in Converged Information Technology (ICT 융합 환경에서의 안전 특성화 접지 설계를 위한 스마트 대지 저항 측정 기술에 관한 연구)

  • Kim, Hong-Yong;Shin, Seung-Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.203-209
    • /
    • 2019
  • In this work, a new land-specific resistance measuring device (GM) and a measuring probe (Grounding Rod) are connected to the WENNER quadrant as power-line communication (PLC). In groups of two (P1,P2) probes, five to ten probes are installed in series on the ground at intervals of 1m, 2m, 4m, 8m, and 16m, respectively. If the PLC signal from the GMD is detected by the receiver of the Probe 1 (P1) for measurement, the minute voltage and current for measurement flow from the PSD (power supply) attached to the probe to the ground, and then, through the soil between P1 and P2, enters the Probe 1 (P2). The resistance value is then measured by the principle of voltage drop due to ground resistance. Measure the earth resistance every T seconds up to 1 trillion and store the measured data on the Arduino Server mounted on the main equipment. Stored measurement data can be derived from formulas by Ohm's Law and from inherent resistance (here,). Data obtained in real time will be linked to CDGES programs installed on Main PC, enabling data analysis and real-time monitoring of the ground environment on land. In addition, a three-dimensional display is possible with 3D graph support by identifying seasonal characteristics such as temperature and humidity of land (soils). The limitations of the study will require specific application measures of Test Bed for commercial access to a model that has been developed and operated experimentally.

Fine Gap Control System Design Using Pneumatics servo System

  • Kim, Dong-Hwan;Kim, Young-Jin;Jeong, Dae-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.111.2-111
    • /
    • 2001
  • The research focuses on controlling a gap to measure the surface defect in semi-conductor fabrication device. The measurement is available accompanying a near field image gap control. In this article, a pneumatic servo system is adopted for the near field gap control. The advantage of the pneumatic servo system is on the preventing the possibility of contacting the device to the wapper surface, fence arising fatal damage. Furthermore, the air from the pneumatic system blows the some particle on the wapper during controlling. The target gap is less than 20 $\mu$m and the gap should keep same amount while the device moves around the surface. The experiment by the pneumatic servo control system is done by employing a simple PID control, and the tracking performance is remarkably verified. The target gap is set from 10 $\mu$m to 100 $\mu$m ...

  • PDF

Improved Performance of White Phosphorescent Organic Light-Emitting Diodes through a Mixed-Host Structure

  • Lee, Jong-Hee;Lee, Jeong-Ik;Chu, Hye-Yong
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.642-646
    • /
    • 2009
  • Highly efficient white phosphorescent organic light-emitting diodes with a mixed-host structure are developed and the device characteristics are studied. The introduction of a hole-transport-type host (N, N'-dicarbazolyl-3-3-benzen (mCP)) into an electron-transport-type host (m-bis-(triphenylsilyl)benzene (UGH3)) as a mixed-host emissive layer effectively achieves higher current density and lower driving voltage. The peak external quantum and power efficiency with the mixed-host structure improve up to 18.9% and 40.9 lm/W, respectively. Moreover, this mixed-host structure device shows over 30% enhanced performance compared with a single-host structure device at a luminance of 10,000 $cd/m^2$ without any change in the electroluminescence spectra.

A Scheme of Standard M2M and FIPA based Agent Communication in M2M Environment (M2M(Machine to Machine) 모델 표준화 개요 및 M2M 환경에서의 FIPA 기반 Agent 간 통신에 대한 연구)

  • Kim D.H.;Song J.Y.;Lee S.W.;Lim S.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1887-1892
    • /
    • 2005
  • In the future, a machine-tool will be more improved in the form of a knowledge evolution based device. In order to develop the knowledge evolution based machine-tool, this paper proposes the structure of standard M2M(Machine To Machine) and the scheme of agent communication in environment. The communication agent such as dialogue agent has a role of interfacing with another machine for cooperation. To design of the communication agent module in M2M environment, FIPA(Foundation of Intelligent Physical Agent) and ping agent based on JADE(Java Agent Development Framework) or FIPA-OS(Open Source) are analyzed in this study. Through this, it is expected that the agent communication can be more efficiently designed and the knowledge evolution based machine-tool can be hereafter more easily implemented.

  • PDF