• Title/Summary/Keyword: M2M Device

Search Result 2,296, Processing Time 0.027 seconds

Analysis of the characteristics of inertial sensors to detect position changes in a large space (넓은 공간에서 위치 변화를 감지하기위한 관성 센서의 특성 분석)

  • Hong, Jong-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.770-776
    • /
    • 2021
  • Positioning systems have been actively researched and developed over the past few years and have been used in many applications. This paper presents a method to determine a location in a large space using a sensor system consisting of an accelerometer and a single-axis gyroscope. In particular, to consider usability, a sensor device was loosely worn on the waist so that the experimental data could be used in practical applications. Based on the experimental results of circular tracks with radiuses of 1m and 3m, in this paper, an algorithm using the threshold of rotation angle was proposed and applied to the experimental results. A tracking experiment was performed on the grid-pattern track model. For raw sensor data, the average deviation between the final tracking point and the target point was approximately 15.2 m, which could be reduced to approximately 4.0 m using an algorithm applying the rotation angle threshold.

A 15 nm Ultra-thin Body SOI CMOS Device with Double Raised Source/Drain for 90 nm Analog Applications

  • Park, Chang-Hyun;Oh, Myung-Hwan;Kang, Hee-Sung;Kang, Ho-Kyu
    • ETRI Journal
    • /
    • v.26 no.6
    • /
    • pp.575-582
    • /
    • 2004
  • Fully-depleted silicon-on-insulator (FD-SOI) devices with a 15 nm SOI layer thickness and 60 nm gate lengths for analog applications have been investigated. The Si selective epitaxial growth (SEG) process was well optimized. Both the single- raised (SR) and double-raised (DR) source/drain (S/D) processes have been studied to reduce parasitic series resistance and improve device performance. For the DR S/D process, the saturation currents of both NMOS and PMOS are improved by 8 and 18%, respectively, compared with the SR S/D process. The self-heating effect is evaluated for both body contact and body floating SOI devices. The body contact transistor shows a reduced self-heating ratio, compared with the body floating transistor. The static noise margin of an SOI device with a $1.1\;{\mu}m^2$ 6T-SRAM cell is 190 mV, and the ring oscillator speed is improved by 25 % compared with bulk devices. The DR S/D process shows a higher open loop voltage gain than the SR S/D process. A 15 nm ultra-thin body (UTB) SOI device with a DR S/D process shows the same level of noise characteristics at both the body contact and body floating transistors. Also, we observed that noise characteristics of a 15 nm UTB SOI device are comparable to those of bulk Si devices.

  • PDF

A Study of Temperature Changes in the Dental Tissues Irradiated by $10.6{\mu}m$ Laser Beam ($CO_2$ 레이저 광의 조사조건에 따른 치아의 치수강내 온도상승에 관한 연구)

  • Ko, D. S.;Bak, Y. H.;Shin, S. H.;Eom, H. S.;Kim, U.;Lee, C. Y.
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.210-216
    • /
    • 1990
  • This study was performed to obtain fundamental data on temperature increases in the dental tissues irradiated by IO.opm laser radiation. For this purpose a experimental facility was established. which was composed of a CO2 laser. a shutter unit and a temperature sensing device. The temperature changes in the pulp chamber of extracted molars. during and after the laser irradiation. were measured as function of laser power. the time of irradration and the thickness of the sample. An empirical formula for the maximum temperature increases, $\DeltaT_m$ was derived from the measured data as follows; $\DeltaT_m=\alphaP\Delta\tauexp(-\betad)$$ where P. $\Delta\tau$ and d are the laser power(W). irradiation time{sec) and the thickness(mm) between pulp chamber and occlusal surface. respectively. Also a theoretical calculation model based on simplified assumptions were established and the results from the calculation were compared with the measured temperature data. A fairly good agreement was obtained.obtained.

  • PDF

Does the maxillary anterior ratio in Korean adults follow the Golden Proportion?

  • Jin, Ming-Xu;Hong, Min-Ho;Lee, Kee-Joon;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.125-130
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of changes in the horizontal plane angle on the mesiodistal width ratios of the maxillary anterior teeth during the acquisition of frontal view photographs, derive these ratios for Korean adults on the basis of the data obtained, and analyze them using the Golden Proportion as a reference. MATERIALS AND METHODS. In experiment I, 30 plaster casts were mounted on an articulator and positioned on the angle-measuring device with a center setting of $0^{\circ}$. The device was rotated to $10^{\circ}$ in $1^{\circ}$ increments in a counterclockwise direction. At each angle, photographs were obtained and analyzed. Experiment II was based on 60 patients who visited the Department of Prosthodontics at Kyungpook National University Dental Hospital from February 2012 to February 2015. The patients were divided into three groups [Male (M), Female (F), Total (M + F)]. Frontal views were obtained for all groups and analyzed. RESULTS. From $1^{\circ}$ to $10^{\circ}$, the relative mesiodistal width ratios for the maxillary anterior teeth showed no significant differences from those at $0^{\circ}$. In all three groups, the relative width ratio of the maxillary central incisor was smaller than that specified in the Golden Proportion; the opposite was true for the canine. CONCLUSION. Our results suggest that the mesiodistal width ratios of the maxillary anterior teeth do not follow the Golden Proportion in Korean adults, and that a change in the horizontal plane angle from $1^{\circ}$ to $10^{\circ}$ during frontal photography does not affect these ratios.

Effect of Stabilizers on Performance of Electroluminescence Display Device (안정화제가 무기 전계발광 디스플레이 소자 성능에 미치는 영향)

  • Shin, DongHyuk;Lim, JongChoo
    • Korean Chemical Engineering Research
    • /
    • v.45 no.4
    • /
    • pp.356-363
    • /
    • 2007
  • The stability of paste solutions for electroluminescence display(ELD) device was found to be greatly affected by kind and dosage of a stabilizer used. The stabilizer Disperbyk-180 showed the best stability performance against phosphor paste solutions among the stabilizers used during this study. The phosphor paste solutions remained stable over 90 days with a wide range of added amounts of Disperbyk-180. Based on the above results, screen printing test was performed. The addition of Disperbyk-180 into phosphor and dielectric paste solutions produced improved qualities such as no phase separation, no bubble generation and no significant viscosity change during printing process. Especially for the phosphor paste solution, both uniformity and brightness were significantly improved and the excellent adhesion onto the ITO film was found. The ELD device fabricated using the above same paste solutions showed brightness of $57.6cd/m^2$ at 100V and 400 Hz. The half lifetime of ELD device was measured as 1,250 hours and almost the same value observed with imported commercial paste solutions.

Characteristics of Algae Occurrence on Environmental Changes (환경변화에 따른 조류 발생 변화)

  • Noh, Seongyu;Shin, Yuna;Choi, Heelak;Lee, Jaeyoon;Lee, Jaean;Rhew, Doughee
    • Journal of Environmental Impact Assessment
    • /
    • v.24 no.3
    • /
    • pp.278-286
    • /
    • 2015
  • Pilot scale system was designed to identify the growth and movement of algae, depending on environmental changes(retention time, nutrient concentration, etc) in Gangjeong-Goryeong Weir of the Nakdong River. Considering the stability of algal culture and easy observation of algal growth, pilot scale system was made of transparent acrylic material(3 sets of flexible cylindrical water tanks with 1 m diameter and 4 m height). Auxiliary equipments include light intercepter, water inflow device for different water depth and storage of reclaimed water. The retention time was 2 days(before construction of weir; treatment 1), 8 days(after construction of weir, 2013; treatment 2) and 30 days(2014; treatment 3). According to the water temperature of treatment 1 were similar by depth, treatment 3 showed a difference between the surface(0 m) and bottom(4 m) more than $3^{\circ}C$. DO, pH showed relatively high in the surface than the bottom. Nutrients showed eutrophic condition in all experiments. The Chlrophyll-a concentration of the treatment 1 showed a relatively lower value than the Chlrophyll-a concentration of the treatment 2 and 3. Therefore, the retention time was considered to influence the growth of phytoplankton.

International Color Consortium Device Profiles (국제 컬러 컨소시엄(ICC)의 디바이스 프로파일)

  • Kim, J.S.;Cho, M.S.
    • Electronics and Telecommunications Trends
    • /
    • v.18 no.2 s.80
    • /
    • pp.25-36
    • /
    • 2003
  • 컴퓨터 입출력 장치를 통해 다루어지는 디지털 영상의 컬러 매칭을 위하여 행해지는 영상의 컬러 정보 변환 표준으로 사용되는 ICC 디바이스 프로파일 표준 규격에 대하여 알아보고, 한국전자통신연구원에서 개발한 ICC 디바이스 프로파일을 이용한 컬러운영시스템 및 프로파일 편집기에 대하여 알아본다.

TWO-STEP THERMOCHEMICAL CYCLES FOR HYDROGEN PRODUCTION WITH DISH TYPE SOLAR THERMAL SYSTEM (접시형 태양열 집광 시스템을 이용한 열화학 사이클의 수소생산)

  • Kwon, Hae-Sung;Oh, Sang-June;Seo, Tae-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.169-176
    • /
    • 2011
  • The two-step water splitting thermochemical cycle is composed of the T-R (Thermal Reduction)and W-D (Water Decomposition)steps. The mechanism of this cycle is oxidation-reduction, which produces hydrogen. The reaction temperature necessary for this thermochemical cycle can be achieved by a dish-type solar thermal collector (Inha University, Korea). The purpose of this study is to validate a water splitting device in the field. The device is studied and fabricated by Kodama et al (2010, 2011). The validation results show that the foam device, when loaded with $NiFe_2O_4/m-ZrO_2$powder, was successfully achieved hydrogen production with 9 (10 with a Xe-light solar simulator, 2009, Kodama et al.) repeated cycles under field conditions. Two foam device used in this study were tested for validation before an experiment was performed. The lab scale ferrite-conversion rate was in the range of 24~76%. Two foam devices were designed to for structural stability in this study. In the results of the experiments, the hydrogen percentage of the weight of each foam device was 7.194 and $9.954{\mu}mol\;g^{-1}$ onaverage, and the conversion rates 4.49~29.97 and 2.55~58.83%, respectively.

  • PDF

Technology trend of optoelectronic device (광전소자의 기술동향)

  • 라용춘;조장연;박대희
    • Electrical & Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.549-556
    • /
    • 1994
  • 광전변화소자(Photo electric conversion device)는 광전효과-내부 광전효과(광도전 및 광기전력) 및 외부광전효과(광전자방출)을 이용하여 광을 전기신호로 변화시키는 소자를 광전자소자라 하며, 광전자 및 양자전자공학의 발전과 함께 많은 개발이 되고 있다. 이 광전변환소자는 주로서 고체박막의 재료를 이용하며, 소자의 소형화, 고성능화, 고신뢰성등의 요구와 함께 광전기술연구가 활발하게 진행되고 있다. 현재 광전소자의 광의 파장은 가시부만이 아니고, X선으로 부터 적외선까지에 걸쳐 있다. 이 파장에 대응하여 각종의 단결정이 필요하고, 소자의 설계가 요구된다. 이들의 응용은 소자의 광의 발진, 증폭, 검출의 소자만이 아니고 변조, 편향, 기록, 전달로등 다종다양의 기능을 갖는 소자가 요구되고 있다. 이들의 Optoelectronic Device의 연구가 활발하게 진행되어 새로운 광전소자의 제품이 개발되고 있어, 이에 대한 소개를 하고져 한다.

  • PDF