• Title/Summary/Keyword: M2M Device

Search Result 2,296, Processing Time 0.038 seconds

A Study on Characteristics of Current-Voltage Relation by sizes for Double Gate MOSFET (DGMOSFET의 크기에 따른 전류-전압특성변화에 관한 연구)

  • Jung, Hak-Kee;Na, Young-Il;Lee, Jae-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.884-886
    • /
    • 2005
  • In this paper, we have investigated characteristics of current-voltage for double gate MOSFET with main gate and side gate. Investigated current-voltage characteristics of channel length changed len호 of channel from 1${\mu}$m to 3${\mu}$m. Also, compare and analyzed characteristics of changed of operation temperature changing current that is dignity. gate voltage could know 2V that is superior than device characteristics of current voltage characteristic in 77K acts in room temperature when approved.

  • PDF

Suprahilar Control of Glissonean Pedicle in the Open Anatomic Liver Resections: A Single Centre Experience

  • Aleksandar Karamarkovic;Milos Bracanovic;Bojan Jovanovic;Sanja Tomanovic Vujadinovic
    • Journal of Digestive Cancer Research
    • /
    • v.4 no.2
    • /
    • pp.113-121
    • /
    • 2016
  • Background: We evaluated technique of hepatic resections using suprahilar-extrafascial dissection of Glissonean pedicle with vascular stapling device for pedicle transection with intent to minimize operative time and blood loss. Methods: We analyzed the clinical records of 326 patients who underwent anatomic liver resection by suprahilar-extrafascial pedicle isolation with vascular stapling division technique. Results: The minor liver resections were associated with significantly shorter surgery duration (105.1±21.1 vs. 225.6±75.6) and transection time (40.1±14.5 vs. 96.3±55.2) than major hepatectomies (p<0.0001 for all). The mean blood loss was 350.8±100.5 mL in minor resection and 485.4±250.2 mL in major resection (p=0.001). The mean blood transfusion requirement was 400.8±109.5 mL for minor resections and 550.9±100.0 mL for major hepatectomy (p=0.072). There was no significant difference in morbidity and mortality between groups (p=0.980; p=0.945). Major as well as minor liver resection were oncology superior with no significant difference in the 5-year overall survival rates. Conclusion: Suprahilar-extrafascial dissection of Glissonean pedicle represents an effective and safe technique of liver resection. Presented approach allows early and easy ischemic delineation of appropriate liver territory to be removed with selective inflow vascular control. It is not time consuming and it is very useful in re-resection, as well as oncological reasonable.

  • PDF

Electron Transport Layer(ETL) in the New Organics applied to evaluate the characteristics of OLED (유기물의 ETL적용에 따른 OLED의 특성평가)

  • Kim, Tae-Yong;Moon, Dae-Gyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04a
    • /
    • pp.37-38
    • /
    • 2008
  • In this paper, we have developed Organic light-emitting devices(OLEDs) using various thicknesses of new electron transport layer. The device structure of ITO/ 2-TNATA(15nm)/ DPVBi(40nm)/ New ETL(20nm,60nm,100nm)/ LiF(0.5nm)/Al(100nm) has been used. The operating voltage of the device was almost independent of the new ETL thickness, due to its high electron conducting property. For example, the operating voltages of the devices with 20nm and 60nm layers are almost 5V at a current density $200mA/cm^2$. The device with the new ETL shows the low turn-on of 2.5V.

  • PDF

The Development of 2-Dimensional Inspection Algorithm using Camera for BGA device (카메라를 이용한 BGA 소자의 2차원 결함검출 알고리즘 개발)

  • Kim, Kee-Soon;Kim, Joon-Seek;Joo, Hyo-Nam
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.437-442
    • /
    • 2005
  • In this paper, we proposed the 2-dimensional inspection algorithm for micro-BGA(Ball Grid Array) device using a vision system. The proposed method uses the subpixel algorithm for high precision. The proposed algorithm preferentially extracts the package area of device in the input image. After the extraction of package area, each ball areas are extracted by ball search window method. The parameters for inspection are calculated for the extracted ball area. In the simulation results, we have the average error within $17{\mu}m$.

  • PDF

Development of Click Chemistry in Polymerization and Applications of Click Polymer

  • Karim, Md. Anwarul
    • Rubber Technology
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Click chemistry had enjoyed a wealthy decade after it was introduced by K.B.Sharpless and his co-worker on 2001. Since there is no optimized method for synthesis of click polymer, therefore, this paper introduced three click reaction methods such as catalyst, non-catalyst and azide-end capping for fluorene-based functional click polymers. The obtained polymers have reasonable molecular weight with narrow PDI. The polymers are thermally stable and almost emitted blue light emission. The synthesized fluorene-based functional click polymers were characterized to compare the effect of click reaction methods on polymer electro-optical properties as well as device performance on quasi-solid-state dye sensitized solar cells (DSSCs) applications. The DSSCs with configuration of $SnO_2:F/TiO_2/N719$ dye/quasi-solid-state electrolyte/Pt devices were fabricated using these click polymers as a solid-state electrolyte components. Among the devices, the catalyzed click polymer composed device exhibited a high power conversion efficiency of 4.62% under AM 1.5G illumination ($100mW/cm^2$).These click polymers are promising materials in device application and $Cu^I$-catalyst 1, 3-dipolar cycloaddition click reaction is an efficient synthetic methodology.

  • PDF

INFLUENCE OF MICROHARDNESS AND FLUORIDE CONTENT OF TOOTH STRUCTURE BY FLUORIDE-CONTAINING RESTORATIVE MATERIALS (수복재에 함유된 불소가 치질의 미세경도와 불소 함유량에 미치는 영향)

  • Lee, Su-Jong;Cho, Young-Gon;Kim, Jong-Uk;Park, Byung-Cheul
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.1
    • /
    • pp.36-43
    • /
    • 2004
  • The purpose of this study was to compare the microhardness and the fluoride content of enamel and dentin around fluoride- or non fluoride-containing restorations. Forty extracted human teeth were used and prepared cervical cavities on proximal surface. Experimental teeth were divided into five groups . Group 1 : Prime & Bond NT and Z100, Group 2 Prime & Bond NT and F2000, Group 3 : Scotchbond Multi-purpose and Z100, Group 4 : Scothcbond Multi-purpose and F2000, Group 5 : Fuji II LC. The cavities were filled with dentin adhesives and restorative materials. After each tooth was bisected, one half was tested microharaness and the other half was analyzed the fluoride at the enamel and dentin by an EPMA-WDX device. The results were as follows; 1. There was no statistical difference among the microhardness of enamel surface in all group. 2. The microhardness at dentin of $100{\;}\mu\textrm{m}$ point in Group 2 and $20{\;}\mu\textrm{m}$ point in Grocup 4 was lower than that of normal dentin (p>0.05). 3. There was no statistical difference among the fluoride content of enamel surface in all group. 4. The fluoride content at the dentin of $30{\;}\mu\textrm{m}$ point in Group 2 and 5 were higher than those at $100{\;}\mu\textrm{m}{\;}and{\;}200{\;}\mu\textrm{m}$ point in Group 2 and normal dentin (p<0.05). 5. At the dentin of $30{\;}\mu\textrm{m}$ point, Group 2 showed higher fluoride content than Group 1 and 3, and Group 5 showed higher fluoride content than other groups.

Development of a Crawler Type Vehicle to Travel in Water Paddy Rice Field for Water-Dropwort Harvest

  • Jun, Hyeon-Jong;Kang, Tae-Gyoung;Choi, Yong;Choi, Il-Su;Choi, Duck-Kyu;Lee, Choung-Keun
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.240-247
    • /
    • 2013
  • Purpose: This study was conducted to develop a rubber-crawler type vehicle as a traveling device for harvesting water-dropwort cultivated in water contained paddy rice field in winter season. Methods: A commercial rubber-crawler type vehicle was used to investigate application of rubber crawler to the paddy rice field as preliminary test. As the result of the preliminary test, a both prototype traveling device with rubber crawlers for a water-dropwort harvest was designed with inclination of $45^{\circ}$ at the front-end and rear-end of crawler under the basic water depth of 0.6 m in the paddy rice field. The device was fabricated and attached to the experimental harvesting test devices on the front of the prototype vehicle. The size of the prototype crawler vehicle with a harvesting part is $2,800{\times}1,460{\times}1,040 $ (mm) ($L{\times}W{\times}H$) with weight of 9.21 kN (maximum). Sizes of the crawler of prototype vehicle are ground contact length of 900 mm, width of 180 mm, height of 1,070 mm and distance between center to center of crawlers of 720 mm. The side-overturn angle of the prototype was $26.4^{\circ}$. Results: Driving performance of the prototype vehicle in water contained paddy field were good at both forward and reverse (backward) directions as weights were applied. The drawbar pull and the maximum sinking depth of the prototype vehicle were 3.5 kN and 0.13 m respectively at water depth of 0.5 m, when the weight and bearing capacity of the prototype rubber crawler in the paddy field were 8.51 kN and 26.3 $kN/m^2$, respectively. Conclusions: Results of the driving test performance of the prototype crawler in paddy rice field at the water depth of 0.5 m were satisfactory. The prototype had enough drawbar pull and driving ability in the deep water contained paddy field.

Performance Analysis of Cellular Networks with D2D communication Based on Queuing Theory Model

  • Xin, Jianfang;Zhu, Qi;Liang, Guangjun;Zhang, Tiaojiao;Zhao, Su
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.6
    • /
    • pp.2450-2469
    • /
    • 2018
  • In this paper, we develop a spatiotemporal model to analysis of cellular user in underlay D2D communication by using stochastic geometry and queuing theory. Firstly, by exploring stochastic geometry to model the user locations, we derive the probability that the SINR of cellular user in a predefined interval, which constrains the corresponding transmission rate of cellular user. Secondly, in contrast to the previous studies with full traffic models, we employ queueing theory to evaluate the performance parameters of dynamic traffic model and formulate the cellular user transmission mechanism as a M/G/1 queuing model. In the derivation, Embedded Markov chain is introduced to depict the stationary distribution of cellular user queue status. Thirdly, the expressions of performance metrics in terms of mean queue length, mean throughput, mean delay and mean dropping probability are obtained, respectively. Simulation results show the validity and rationality of the theoretical analysis under different channel conditions.

White Electroluminescence from Bicarbazyl-containing Conjugated Polymers as Single-Emitting Component

  • Kang, In-Nam;Kim, Yang-Bae;Lim, Sung-Hwan;Chung, Min-Chul;Oh, Se-Young;Kim, Sung-Ryong;Lee, Ji-Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.1
    • /
    • pp.135-138
    • /
    • 2008
  • Two bicarbazyl-containing fluorene copolymers, PFEBCz (95/5) and PFEBCz (75/25), were synthesized for white light electroluminescence from a single emitting polymer. All synthesized polymers were soluble in common organic solvents such as chloroform and toluene. The weight-average molecular weights (Mw) of the PFEBCz (95/5) and PFEBCz (75/25) copolymers were found to be 11,000 and 5,700 with polydispersity indices 1.4 and 1.8. The EL spectrum of the PFEBCz (75/25) device showed bright white-light emission with CIE coordinates of (0.32, 0.34) at 1000 cd/m2, which is very close to that for pure white (0.33, 0.33). This white emission may have been due to strong excimer formation between the bicarbazyl and fluorene polymer backbone. The device exhibited a maximum brightness of 3400 cd/m2 with a maximum efficiency of 0.2 cd/A.

A Path Control Switch Chip for an Unidirectional Path Swithced Ring (단방향 경로 스위칭 링을 위한 경로 제어 스위치 소자)

  • 이상훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1245-1251
    • /
    • 1999
  • A 1.25Gb/s path control switch chip has been designed and implemented with COMPASS tool and 0.8${\mu}{\textrm}{m}$ CMOS gate-array of LG semiconductor. This device controls the path of digital singnals in SDH-based transmission system. The proposed switch chip is suitable for self-healing operations both in a linear network and an unidirectonal ring, The self-healing operation of the switch is effectively done by the configuration information stored in the resisters of the switch. The test device adapted to SDH-based transmission system, show immediate restoration and a 10-11~10-12 bit error raito. And 2.5Gb/s or more high throughput can be realized by combining rwo identical or more switches with the parallel architecture.

  • PDF