• Title/Summary/Keyword: M&S system

Search Result 10,213, Processing Time 0.04 seconds

Effect of Nutrient Solution Strength on Growth of Phalaenopsis in an Ebb and Flow System (Ebb and Flow 시스템을 이용한 호접란 수경재배시 생장에 미치는 배양액 농도의 영향)

  • An, Dong-Choon;Park, Seon-Hye;Been, Chul-Gu;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.16 no.3
    • /
    • pp.199-204
    • /
    • 2007
  • This experiment was conducted to investigate the effect of nutrient solution strength on the growth of miniature multiflora P. amabilis and P. Taisuco Red Jewel at two growth stages during four months cultivation in an ebb and flow system. Early stage plants gained the biggest leaf length and width when nutrient solution strength was EC 0.5 or $1.0dS{\cdot}m^{-1}$ in P. amabilis, and EC $1.5dS{\cdot}m^{-1}$ in P. Taisuco Red Jewel. Root length and weight were the greatest when nutrient solution strength was EC $0.5dS{\cdot}m^{-1}$ in both cultivars and this trend was also found in middle stage plants. Fresh and dry weights of leaves increased as nutrient solution strength was elevated and were the greatest when nutrient solution strength was EC $1.5dS{\cdot}m^{-1}$ in P. amabilis. On the contrary elevation of nutrient solution strength decreased fresh weight of roots, being the greatest when nutrient solution strength was EC $0.5dS{\cdot}m^{-1}$. This trend was also found in P. Taisuco Red Jewel and P. amabilis at middle growth stage. The T/R ratio and chlorophyll content increased with nutrient solution strength and were the greatest regardless of cultivar and growth stage when nutrient strength was EC $1.5dS{\cdot}m^{-1}$.

Analysis of Relationship Between Injection Dose and Exposure Dose in PET/CT Scan: Initial Study (PET/CT에서 방사성 의약품 주입량이 방사선 피폭에 미치는 영향분석: 초기연구)

  • Park, Hoon-Hee;Lyu, Kwang-Yeul
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.351-357
    • /
    • 2011
  • The $^{18}F$-FDG is one of the widely used isotopes for PET/CT scans. Dose amount injected to the patient depends on the characteristics of PET/CT systems. Obviously, the technologists who contact with patients would be exposed as well. In this study, we evaluated the exposed dose of the technologist who works on the PET/CT scanner. The exposed dose were measured every month with the TLDs from 6 technologists. Each technologist is shift-worker who manages 3 different PET/CT systems(Scanner 1(S1): 0.15 mCi/kg, Scanner 2(S2): 0.17 mCi/kg, Scanner 3(S3): 0.12 mCi/kg). The average exposed doses of technologists for each PET/CT system were measured as 0.76 mSv for S1, 0.93 mSv for S2 and 0.47 mSv for S3. The maximum dose was 1.12 mSv and minimum was 0.42 mSv. The results showed that there was a correlation between exposed dose and PET/CT system(p<0.005). Less injected dose for patient occurs less exposed dose for technologist. Various studies for the low dose PET/CT system are required for not only the patient but also the technologist.

A Markovian queue with two serial servers and its application to the double tollbooth system (M/M/2 직렬-서어버 모형의 분석 및 응용)

  • 양원석;채경철
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.22 no.2
    • /
    • pp.1-12
    • /
    • 1997
  • We consider an M/M/2 queue with two servers placed in series. System performance measures that we present in closed expressions are the first and the second moments for the system size, the queue walting time and the sojourn time. We also present an algorithm for computing the queue waiting time distribution function based on the randomization method. As an application, we analyze the double tollbooth system and compare its performance with the conventional single tollbooth system's.

  • PDF

A Study on the V&V Process of M&S for the Test and Evaluation (시험평가용 M&S에 대한 V&V 프로세스 연구)

  • Park, Ju-Hye
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.397-404
    • /
    • 2019
  • When developing a weapon system, a T&E(Test and Evaluation) can be performed using M&S for the test items that cannot be evaluated in the real world. In this case, the VV&A activities are required to prove the credibility of M&S for the T&E. Recently, the use of M&S has been increasing as the R&D trends of weapon systems are becoming more advanced. Therefore, the VV&A activities are also increasing. The VV&A activities aim to verify, validate, and accredit that the simulation can represent a real system and ensure credibility regarding its purpose and intention of use. VV&A activities are divided into V&V and Accreditation. When performing VV&A in the ADD (Agency for Defense Development), the V&V activities are performed by a separate department of the ADD and the accreditation activities are performed in the DTAQ (Defense Agency for Technology and Quality). This paper proposes a V&V process for a T&E of M&S that has been performed in ADD. The process is used to verify and validate the documents and data generated during the development process according to the accreditation criteria, and provides objective data that can be used to judge whether the accreditation decision and acceptance criteria are met.

A Research on the SILS System for Design and Analysis of Non-Communication Electronic Warfare Weapons based on the Engineering M&S Technique (공학급 M&S 기반 비통신 전자전무기체계 설계 분석 지원을 위한 SILS 시스템 연구)

  • Shin, Dongcho;Shin, Wookheon;Kim, Taehyun;Lee, Chiho;Jeong, Unseob
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.272-280
    • /
    • 2021
  • We research and develop a SW-based virtual testing product that can be commonly used in the design/development of non-communication EW systems before the production of physical test products. Through this study, we have developed M&S technology to improve the accuracy of EW weapon system analysis/design and to verify and predict the performance of EW equipment, and to develop proven engineering module models and model base systems. It proposes a technology to build an EW M&S framework that can flexibly link/integrate various engineering/engage-level EW heterogeneous M&S systems.

A Novel Nonmechanical Finger Rehabilitation System Based on Magnetic Force Control

  • Baek, In-Chul;Kim, Min Su;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.155-161
    • /
    • 2017
  • This paper presents a new nonmechanical rehabilitation system driven by magnetic force. Typically, finger rehabilitation mechanisms are complex mechanical systems. The proposed method allows wireless operation, a simple configuration, and easy installation on the hand for active actuation by magnetic force. The system consists of a driving coil, driving magnets (M1), and auxiliary magnets (M2 and M3), respectively, at the finger, palm, and the center of coil. The magnets and the driving coil produce three magnetic forces for an active motions of the finger. During active actuations, magnetic attractive forces between M1 and M2 or between M1 and M3 enhance the flexion/extension motions. The proposed system simply improves the extension motion of the finger using a magnetic system. In this system, the maximum force and angular variation of the extension motion were 0.438 N and $49^{\circ}$, respectively. We analyzed the magnetic interaction in the system and verified finger's active actuation.

FOLIATIONS ASSOCIATED WITH PFAFFIAN SYSTEMS

  • Han, Chong-Kyu
    • Bulletin of the Korean Mathematical Society
    • /
    • v.46 no.5
    • /
    • pp.931-940
    • /
    • 2009
  • Given a system of smooth 1-forms $\theta$ = ($\theta^1$,...,$\theta^s$) on a smooth manifold $M^m$, we give a necessary and sufficient condition for M to be foliated by integral manifolds of dimension n, n $\leq$ p := m - s, and construct an integrable supersystem ($\theta,\eta$) by finding additional 1-forms $\eta$ = ($\eta^1$,...,$\eta^{p-n}$). We also give a necessary and sufficient condition for M to be foliated by reduced submanifolds of dimension n, n $\geq$ p, and construct an integrable subsystem ($d\rho^1$,...,$d\rho^{m-n}$) by finding a system of first integrals $\rho=(\rho^1$,...,$\rho^{m-n})$. The special case n = p is the Frobenius theorem on involutivity.

A Study on Inequality Rate of Lubrication for Motor-driven Cylinder Lubricator by the Electronically Controlled Quill System Equipped with an Accumulating Distributor in a Large Two-stroke Diesel Engine (대형 2행정 디젤기관용 축압분배기 부착 전자제어식 퀼 시스템 모터구동 실린더 주유기의 주유 불균일률에 관한 연구)

  • Bae, Myung-Whan;Jung, Hwa;Bae, Chang-Hwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.3
    • /
    • pp.26-36
    • /
    • 2012
  • Minimizing the cylinder wear and the consumption rate of cylinder oil in a large two-stroke diesel engine is of great economic importance. A motor-driven cylinder lubricator for Sulzer RT-flex large two-stroke diesel engines developed by authors is in need of mounting a quill system to lubricate cylinder parts for a smooth operation. In order to apply the common-rail lubricating system to the developed cylinder lubricator as the second research stage, the mechanical quill system with a progressively quantitative distributor (M.D.S.) is improved in the electronically controlled quill system with an accumulating distributor (E.D.S.). In this study, the effects of lubricator motor speed, plunger stroke and cylinder back pressure on oil feed rate and inequality rate are experimentally investigated by applying E.D.S. to the developed cylinder lubricator. It is found that the oil feed rate of E.D.S. is higher than that of M.D.S. because of the increase of delivery speed and volume by changing the role of accumulator in the same experimental condition. It can be also shown that, in E.D.S., the inequality rate is decreased a little or hardly unchanged as the cylinder back pressure and plunger stroke is elevated, while the inequality rate increased in M.D.S.. The inequality rates of E.D.S. and M.D.S. are lowered as the lubricator motor speed is increased.