• Title/Summary/Keyword: Luminous Efficacy

Search Result 127, Processing Time 0.025 seconds

A Study of the Discharge Characteristics of PDP having Auxiliary Electrodes with High Xe% Working Gas

  • Jang, Jin-Ho;Lee, Don-Kyu;Ok, Jung-Woo;Kim, Deok-Won;Kim, Dong-Hyun;Lee, Hae-June;Lee, Ho-Jun;Par, Chung-Hoo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1189-1192
    • /
    • 2007
  • We propose new driving schemes, asymmetry and long gap mode, of PDP having auxiliary electrode between scan and common electrode. For the asymmetric modes, the auxiliary electrode located nearly center of the primary electrodes is connected to the scan of common electrode during all periods of reset, address and sustain. For the long gap mode, it is electrically disconnected or maintained at dc voltage of Vs/2 during sustain period except the first several sustain pulses. The proposed structure and driving method can provide higher luminous efficacy by minimizing consumption energy. The effectiveness of the new driving schemes has been investigated for various Xe partial pressure conditions.

  • PDF

Daylighting Performance Nomographs for Toplit Atrium (아트리움의 자연채광 성능 예측용 노모그래프)

  • Kim, Jeong-Tai;Chung, Yu-Gun
    • KIEAE Journal
    • /
    • v.3 no.2
    • /
    • pp.45-50
    • /
    • 2003
  • Today, there are increasing evidences that daylight is essential for health, well-being and productivity. One of the strong contributions, which atria can make to advantages in building, is in allowing the use of daylight. This research is to develop nomographs and to evaluate the daylight performances of toplit atria with louvers. For this purpose, the evaluation models of toplit atria with well indexes of 0.5, 1.0 or 2.0 have been selected through the field surveys of atrium buildings in Seoul area. Also, weather data for solar irradiance and luminous efficacy were gathered from the recently conducted previous researches. The computer simulations were performed under clear sky conditions, using the ADELINE program, and various daylight performances were analyzed by the daylight illumination ratio. Analyzing the simulation results, solar altitude, solar azimuth, and louver angle and louver reflectance were found to be important factors affecting the daylight performance of toplit atria. Using these variables, regression equations have been formulated, and the nomographs, which may predict the daylight performances of toplit atria with louvers, were developed. The developed nomographs were validated through comparing the results of nomograph predictions to the results of scale-model experiments.

cactus Fence electrode structure in AC PDP to improve luminous efficacy (AC PDP의 효율 향상을 위한 cactus Fence 전극구조)

  • Jung, Sun-Gil;Nam, Hyung-Woo;Kim, Dong-Hyun;Park, Cha-Su;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1311-1312
    • /
    • 2008
  • 차세대 대형 FPD(Flat Panel Display)로 각광받는 PDP(Plasma Display Panel)는 cost, 소비전력, 효율 등의 문제점이 있다. 본 연구에서는 저가격화를 실현하기 위하여 종래 사용되었던 투명전극인 ITO(Indium-Tin Oxide)전극 대신 금속(Ag) 전극만을 사용하여 공정을 간소화한 Fence 전극구조를 제안하였다. 그리고 소비전력의 감소와 효율의 향상을 위해 격벽쪽의 전극을 제거하여 방전경로상의 저항을 증가시켜 방전전류를 감소시키는 동시에 하전입자의 격벽손실을 줄이는 4-inch Test Panel을 제작하여 전기광학적 특성 실험을 하였다. 제안한 구조의 돌기길이를 변화시켜 방전개시전압, 휘도, 소비전력, 효율 등을 측정, 비교하여 power가 14%감소하여 효율을 11% 향상 시킬 수 있었다.

  • PDF

Ultra accelerated molecular dynamics study on electronic structure and luminous efficacy of PDP protecting layer

  • Takaba, Hiromitsu;Serizawa, Kazumi;Suzuki, Ai;Tsuboi, Hideyuki;Hatakeyama, Nozomu;Endou, Akira;Kubo, Momoji;Kajiyama, Hiroshi;Miyamoto, Akira
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.169-172
    • /
    • 2009
  • We developed ultra-accelerated quantum chemical molecular dynamics and characterization simulators for study and design of plasma display panel (PDP) related materials. By use of these simulators, realistic structure of PDP materials is drawn on the computer. Furthermore, based on the structures, various properties such as secondary electron emission coefficient are successfully evaluated. In this report, we will discuss the theoretical secondary electron emission coefficient for several protecting layer materials and the effect of surface structure on the properties based on the result of atomistic simulations.

  • PDF

Improving current and luminous efficacy of red phosphorescent Organic Light Emitting Diodes (OLEDs) by introducing graded-layer device designs enabled by Organic Vapor Phase Deposition (OVPD)

  • Schwambera, Markus;Keiper, Dietmar;Meyer, Nico;Heuken, Michael;Lindla, Florian;Bosing, Manuel;Zimmermann, Christoph;Jessen, Frank;Kalisch, Holger;Jansen, Rolf H.;Gemmern, Philipp Van;Bertram, Dietrich
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1140-1143
    • /
    • 2009
  • Organic Vapor Phase Deposition (OVPD) equipment enables the accurate and simultaneous control of deposition rates of multiple materials as well as their homogenous mixing in the gas phase. Graded or even cross-faded layers by varying carrier gas flow are options to improve OLED performances. As example, we will show how the efficacies of standard red phosphorescent OLEDs with sharp interfaces can be increased from 18.8 cd/A and 14.1 lm/W (1,000 cd/$m^2$) to 36.5 cd/A (+94 %, 18 % EQE) and 33.7 lm/W (+139 %) by the introduction of cross-fading, which is a controlled composition variation in the organic film.

  • PDF

The Performance of generated Heating Energy from Interior Lighting Fixtures (실내조명의 발열량 예측에 관한 실험 연구)

  • Choi, Jong-seon;Lim, Hong-Soo;Kim, Kyung-Ah;Lee, Keum-hwan;Koo, Jae-Oh;Kim, Gon
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.27-32
    • /
    • 2010
  • Approximately 20 percentage of energy consumptions in buildings is consumed as lighting energy. Thus, most of the corporations of lighting fixture have launched low energy products. However, many researchers focused on the only luminous efficacy for energy conservation and used the evaluating tool of study. This can not gauge the precise cooling load related on generated heat of artificial lighting. In order to assess an effect of the temperature variation of lighting resources, the main purpose of this study is to predict the generated heating energy from lighting by measuring the thermal variation in scale model to reduce external noise. Also this paper used MX100 data logger to record at an interval of 1 minute for 60 minutes for the temperature of interior lightings such as incandescent lamp, fluorescent light, halogen lamp and LED lamp. As a result, LED lamp generated the lowest heat. On the other hand, incandescent lamp did the highest.

Optimization of Phosphor Contents and Heat-treatment Temperature in White LED Package with Glass Remote Phosphor Structure (Glass Remote Phosphor 구조를 갖는 백색 LED 패키지의 형광체 함량과 열처리 온도 최적화)

  • Jeong, Hee-Suk;Hong, Seok-Gi;Ryeom, Jeongduk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.30-38
    • /
    • 2016
  • In this research, a 6W white LED package with a Glass Remote Phosphor was developed to improve the life of an LED package. The Glass Remote Phosphor was fabricated by the Phosphor in Glass (PiG) method, wherein phosphor YAG:Ce was mixed with glass frit and then heat treated. A paste with 75wt.% of a phosphor substance and 25wt.% glass frit was coated on a glass substrate two times using the screen-printing technique and heat-treated at $800^{\circ}C$ ; this structure gave a luminous efficacy of 136.1lm/W, color rendering index of 74Ra, and color temperature of 5,342K, thus satisfying the requirements as a light source for lighting. Moreover, an IES LM-80 accelerated life test was conducted on the same LED package for 6,000h in order to estimate the L70 lifetime based on IES TM-21. The results showed guaranteed lifetimes of 213,000h at $55^{\circ}C$, 245,000h at $85^{\circ}C$, and 209,000h at $95^{\circ}C$.

Surface Control of Planarization Layer on Embossed Glass for Light Extraction in OLEDs

  • Cho, Doo-Hee;Shin, Jin-Wook;Moon, Jaehyun;Park, Seung Koo;Joo, Chul Woong;Cho, Nam Sung;Huh, Jin Woo;Han, Jun-Han;Lee, Jonghee;Chu, Hye Yong;Lee, Jeong-Ik
    • ETRI Journal
    • /
    • v.36 no.5
    • /
    • pp.847-855
    • /
    • 2014
  • We developed a highly refractive index planarization layer showing a very smooth surface for organic light-emitting diode (OLED) light extraction, and we successfully prepared a highly efficient white OLED device with an embossed nano-structure and highly refractive index planarization layers. White OLEDs act as an internal out-coupling layer. We used a spin-coating method and two types of $TiO_2$ solutions for a planarization of the embossed nano-structure on a glass substrate. The first $TiO_2$ solution was $TiO_2$ sol, which consists of $TiO_2$ colloidal particles in an acidic aqueous solution and several organic additives. The second solution was an organic and inorganic hybrid solution of $TiO_2$. The surface roughness ($R_a$) and refractive index of the $TiO_2$ planarization films on a flat glass were 0.4 nm and 2.0 at 550 nm, respectively. The J-V characteristics of the OLED including the embossed nano-structure and the $TiO_2$ planarization film were almost the same as those of an OLED with a flat glass, and the luminous efficacy of the aforementioned OLED was enhanced by 34% compared to that of an OLED with a flat glass.

An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp (초정압 방전램프(UCD)를 적용한 안전 조명 장치에 관한 연구)

  • Jeong, Poong-Gi;Kim, Young-Chul
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.63-80
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

  • PDF

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities (정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가)

  • Choi, Su-Hyun;Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.