• Title/Summary/Keyword: Lumbar Strength

Search Result 161, Processing Time 0.025 seconds

Follow-up Results of Z-plate Fixation in the Thoracolumbar Burst Fracture (흉요추 방출성 압박골절의 Z-plate를 이용한 고정술후 추적검사 결과)

  • Shim, Byeoung-Su;Kim, Keun-Su;Lee, Jung-Chung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.6
    • /
    • pp.763-771
    • /
    • 2000
  • Objectives : Thoracolumbar burst fractures(TBLF) result in not only compressive deformity of vertebral body but also spinal cord compression by bony fragments. Many thoracolumbar burst fractures demand both anterior decompression and intervertebral fusion. Most of spinal surgeons use anterior instrumentation for anteior intervertebral bony fusion. The use of Z-plate has been increased recently, however there has been only a few reports regarding its clinical long-term strength. We studied nineteen patients with TBLF to find out the long-term stability of Z-plate. Methods : We have operated 19 patients from March 1996 to August 1998. They were treated with anterior decompression through either a transthoracic, retroperitoneal extrapleural or retroperitoneal approach. Retropulsed bony fragments were removed completely by corpectomy. Iliac bone graft was used for interbody fusion in all of the cases. They were evaluated by plain X-ray films including flexion and extention lateral films. Cobbs angle was used to evaluate kyphotic and lateral wedging deformity. Results : Burst fractured sites were T11 in two, three T12, nine L1, and five L2. Mean follow-up duration was fifteen months. Preoperative average kyphotic angle was 23.7 degree. Immediate postoperative kyphotic angle was 10.2 degree. Follow-up resluts of average kyphotic angles revealed 14 degrees. Four patients(21%), including two spinal 3-column injury, showed increasement of kyphotic angle more than 5 degree or breakage of intrumentation. Two patients showed the difference of kyphotic angle more than 3 degree. Five patients(26%) revealed lateral wedging deformity more than 3 degrees. Postoperative complications were two meralgia parestheticas, one pulmonary atelectasis and two donor site infections. Four of the eight patients, who initially showed incomplete spinal cord deficits, were nerologically improved by Frankel's grade. Conclusion : Z-plate fixation and iliac bone graft after anterior decompression in thoracolumbar burst fractures is a safe and easy method. Immediate postoperative results revealed excellent correction of posttraumatic kyphosis, but long-term follow-up evalution showed insufficient strength. Therefore we believe that use of Z-plate should be carefully decided, especially in the case of large lumbar fracture or 3-column injury.

  • PDF

A Survey on the Prevalence of Musculoskeletal Symptom according to Work Task (작업유형별 근골격계 증상 호소율에 관한 조사연구)

  • Oh, Hae-Ju;Lee, Duk-Hee;Park, In-Guen;Jang, She-Han
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.2 s.46
    • /
    • pp.230-241
    • /
    • 1994
  • Though people occupationally exposed to machineries and automation in the industrialized society desire work involving decreased strength, due to the continuous and repetitive activities, a new industrial stress is present. Studies on prevalence of musculoskeletal disease and their related risk factors have evolved. In this study in relation to work tasks, we investigated the differences in musculoskeletal symptoms occurring In each body region. The results of the survey were as follows. 1. When comparing age, level of education, work duration, job satisfaction and leisure time activities according to work task, age in control group was $38.83{\pm}5.5$, in comparison to the other 2 groups was smaller(p<0.05), and level of education in control group was higher (p<0.05). Work duration in the cutting department was $8.04{\pm}4.99$ years longer than the other 2 groups (p<0.05), but there was no difference in the job satisfaction and leisure time activities. 2. The mean of symptom scores of each work task was 1.54 in the cutting department, 1.57 in the press department and 1.59 in the control group, and there was no significant differnce in the 3 groups. The mean of symptom scores for upper extremities in the control group was low but no statistically significant diffrence was shown. 3. When comparing the mean of symptom score according to work task in the each body region, in the shoulder region, the symptom score in the press department which desired strength was higher than the other 2 groups but no significant difference was shown. In the wrist region the cutting department scored 1.01 and in comparison to the other 2 groups was significantly increased (p<0.05). 4. The results of the univariate regression analysis on the major individual risk factors associated with musculoskeletal symptom relating work showed that previous symptom complaints in the same body region was significant risk factor(p<0.001) in the whole body Besides wrist, hip, and knee, psychological problem was shown to be a significant factor(p<0.05). And the body regions which work task was significant risk factor were wrist and neck region (p<0.05). 5. The results of the multiple regression analysis involving significant factors of each body region from the univariate regression analysis showed that previous symptom complaint in whole body region(p<0.001) and psychological problem in the shoulder, elbow and lumbar region (p<0.05) were significant factors, and work task was significant factor in the wrist (p<0.05).

  • PDF

Comparison of Kinematics and Myoelectrical Activity during Deadlift, with and without Variable Banded Resistance, in Healthy, Trained Athletes

  • Everett B. Lohman;Mansoor Alameri;Fulden Cakir;Chih Chieh Chia;Maxine Shih;Owee Mulay;Kezia Marceline;Simran Jaisinghani;Gurinder Bains;Michael DeLeon;Noha Daher
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.53-70
    • /
    • 2024
  • Background: The conventional deadlift is a popular exercise for enhancing trunk, core, and lower extremity strength. However, its use in sports medicine is constrained by concerns of lumbar injuries, despite evidence supporting its safety and rehabilitative benefits. To optimize muscle activation using resistive bands in variable resistance therapy, we explored their feasibility in the deadlift. Design: Comparative experimental design Methods: Surface electromyography recorded muscle activity in the trunk and lower extremities during lifting, with normalization to the isometric Floor Lift using Maximal Voluntary Contraction. Kinematics were measured using inclinometer sensors to track hip and trunk sagittal plane angles. To prevent fatigue, each subject only used one of the three pairs of bands employed in the study. Results: Our study involved 45 healthy subjects (mean age: 30.4 ± 6.3 years) with similar baseline characteristics, except for years of lifting and strength-to-years-of-lifting ratio. Various resistance band groups exhibited significantly higher muscle activity than conventional deadlifts during different phases. The minimal resistance band group had notably higher muscle activity in the trunk, core, and lower extremity muscles, particularly in the end phase. The moderate resistance band group showed increased muscle activity in the mid-and end-phases. The maximum resistance band group demonstrated greater muscle activity in specific muscles during the early phase and overall higher activity in all trunk and lower extremity muscles in the mid and end phases of the deadlift (p<0.05). Conclusion: Our findings provide valuable insights into muscle activation with various resistance bands during deadlift exercise in clinical and gym settings. There appears to be a dose-response relationship between increased resistance bandwidth, external load, myoelectric activation, and range.

Comparative Analysis Between MBT Shoes(Functional walking shoes) and General Sporting Shoes for the Muscle Activity and Energy Consumption (보행용 MBT신발과 일반 신발 보행 시 에너지 소비량과 근 활성도의 비교 분석)

  • Yoon, Bum-Chul;Kang, Se-Yong;Kim, Yae-Jung;Yu, Min-Ho;Lee, Mi-Jung;Kim, Nan-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.13 no.3
    • /
    • pp.65-75
    • /
    • 2006
  • This study was to find out whether MBT shoes were more effective than general sporting shoes on the kinematic physiology. We comparatively analyzed energy consumption, heart rates, rating of perceived exertion, lactic acid density in blood and muscle activity with EMG. The subjects were 10 regular students of K Univ.(5 male and 5 female). They wore the general sporting shoes for stage 1(group 1), the MBT walking shoes for stage 2(group2) under the same conditions. There was one week interval between stages. 1. There was no significant difference in the energy consumption and the heart rates between two groups. Group 1 showed a higher energy consumption and heart rates than Group 2 under the speed of 4.0 mph. On the other hand, Group 2 showed higher ones over the speed of 4.0 mph. 2. There was no significant difference in the rating of perceived exertion and lactic acid density in blood between two groups. But Group 2 showed a lower fatigue strength than Group 1. 3. Group 2 showed a higher muscle activity with EMG than group 1, especially at the speed of 2.0, 2.5, 3.0, 3.5 mph in quadratus lumborum muscle and at 4.0mph in tibialis anterior muscle. In conclusion, we are less tired in MBT shoes than in general sporting shoes. Also, we can dorsiflex better in the ankle joint, straighten the lumbar region well and walk erect in MBT shoes. Specially, when it walks slowly, it is favorable in an erection walk and when it walks quickly, we have advantage of obesity management.

  • PDF

Genome-Wide Association Study of Bone Mineral Density in Korean Men

  • Bae, Ye Seul;Im, Sun-Wha;Kang, Mi So;Kim, Jin Hee;Lee, Soon Hang;Cho, Be Long;Park, Jin Ho;Nam, You-Seon;Son, Ho-Young;Yang, San Deok;Sung, Joohon;Oh, Kwang Ho;Yun, Jae Moon;Kim, Jong Il
    • Genomics & Informatics
    • /
    • v.14 no.2
    • /
    • pp.62-68
    • /
    • 2016
  • Osteoporosis is a medical condition of global concern, with increasing incidence in both sexes. Bone mineral density (BMD), a highly heritable trait, has been proven a useful diagnostic factor in predicting fracture. Because medical information is lacking about male osteoporotic genetics, we conducted a genome-wide association study of BMD in Korean men. With 1,176 participants, we analyzed 4,414,664 single nucleotide polymorphisms (SNPs) after genomic imputation, and identified five SNPs and three loci correlated with bone density and strength. Multivariate linear regression models were applied to adjust for age and body mass index interference. Rs17124500 ($p=6.42{\times}10^{-7}$), rs34594869 ($p=6.53{\times}10^{-7}$) and rs17124504 ($p=6.53{\times}10^{-7}$) in 14q31.3 and rs140155614 ($p=8.64{\times}10^{-7}$) in 15q25.1 were significantly associated with lumbar spine BMD (LS-BMD), while rs111822233 ($p=6.35{\times}10^{-7}$) was linked with the femur total BMD (FT-BMD). Additionally, we analyzed the relationship between BMD and five genes previously identified in Korean men. Rs61382873 (p = 0.0009) in LRP5, rs9567003 (p = 0.0033) in TNFSF11 and rs9935828 (p = 0.0248) in FOXL1 were observed for LS-BMD. Furthermore, rs33997547 (p = 0.0057) in ZBTB and rs1664496 (p = 0.0012) in MEF2C were found to influence FT-BMD and rs61769193 (p = 0.0114) in ZBTB to influence femur neck BMD. We identified five SNPs and three genomic regions, associated with BMD. The significance of our results lies in the discovery of new loci, while also affirming a previously significant locus, as potential osteoporotic factors in the Korean male population.

A Finite Element Simulation of Cancellous Bone Remodeling Based on Volumetric Strain (스폰지 뼈의 Remodeling 예측을 위한 체적 변형률을 이용한 유한요소 알고리즘)

  • Kim, Young;Vanderby, Ray
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.373-384
    • /
    • 2000
  • The goal of this paper is to develop a computational method to predict cancellous bone density distributions based upon continuum levels of volumetric strain. Volumetric strain is defined as the summation of normal strains, excluding shear strains, within an elastic range of loadings. Volumetric strain at a particular location in a cancellous structure changes with changes of the boundary conditions (prescribed displacements, tractions, and pressure). This change in the volumetric strain is postulated to predict the adaptive change in the bone apparent density. This bone remodeling theory based on volumetric strain is then used with the finite element method to compute the apparent density distribution for cancellous bone in both lumbar spine and proximal femur using an iterative algorithm, considering the dead zone of strain stimuli. The apparent density distribution of cancellous bone predicted by this method has the same pattern as experimental data reported in the literature (Wolff 1892, Keller et al. 1989, Cody et al. 1992). The resulting bone apparent density distributions predict Young's modulus and strength distributions throughout cancellous bone in agreement with the literature (Keller et al. 1989, Carter and Hayes 1977). The method was convergent and sensitive to changes in boundary conditions. Therefore, the computational algorithm of the present study appears to be a useful approach to predict the apparent density distribution of cancellous bone (i.e. a numerical approximation for Wolff's Law)

  • PDF

The Effect of Resistance Exercise with Vibration Stimulation on Balance and Gait of Experienced Back Pain Adults (진동자극 저항운동이 허리통증 경험자의 균형과 보행에 미치는 영향)

  • Ko, Min-Gyun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.6
    • /
    • pp.221-230
    • /
    • 2020
  • The purpose of this study was to investigate the effect of resistance exercise with vibration stimulation methods on static balance and gait parameters in experienced back pain adults. This study was Three group pretest-posttest design. A total of 30 experienced back pain adults voluntarily participated in the study. Subjects were randomly assigned to the resistance exercise with 8 Hz vibration stimulation(n=10), resistance exercise with 30 Hz vibration stimulation(n=10), and lumbar stabilization exercise groups(n=10). The static balance and the gait parameters, as such stance phase, swing phase, stride length and cadence, were measured using balance measuring equipment and gait analysis treadmill at before and after 6 week. Intervention of each group were performed, three times a week for 6 weeks, and 30 minutes a day. The effect of intervention on static balance, stance phase, swing phase, stride length and cadence were significantly differences after 6 weeks in each group(p<.05). In the comparison of the effects between the groups, static balance and stance phase were significantly difference after 6 weeks(p<.05), but in the swing phase, stride length and cadence, there were no significant differences. As a result, it is considered that resistance exercise with vibration stimulation improved leg muscle strength by a mechanism causing muscle contraction, and the strengthened leg muscle enhanced had a positive effect on balance ability. And improved balance ability was considered a more positive effect on walking ability by allowing the body to stably control posture while moving.

Effects of 12-week Combined Exercise Program on Short Physical Performance Battery, Bone Mineral Density and Parathyroid Hormone in the Elderly Women (12주간 복합운동이 여성 노인의 신체수행능력, 골밀도 및 부갑상선호르몬에 미치는 영향)

  • Kim, Jung-Sook;Kim, Ji-Hyeon;Ha, Soo-Min;Hynn, Su-Jin;Yoon, Byeong-Kon;Kim, Do-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.519-531
    • /
    • 2018
  • The purpose of this study was to investigate the effects of combined exercise program on short physical performance battery, bone mineral density and parathyroid hormone levels in elderly women. This study subjects were 22 elderly female volunteers, aged 65-75 years and they divided into the combined exercise group(n=11) and the "no exercise" control group(n=11). The combined exercise included the line dance program performed twice per week for 60 minutes and the resistance exercise program performed once per week during 12 weeks. Exercise intensity was progressively increased from RPE "fairly light" to "slightly hard" (from 11 to 14). The findings of this study were as follows; Short physical performance battery(Balance test, gait speed, and rising from a chair five times) and bone mineral density (lumbar spine L2~L4 bone densities, and the T-score) were significantly increased after 12 weeks in the exercise group compared to the baseline. The PTH level was significantly decreased in the exercise group compared to the baseline. In conclusion, regular and continuous physical activity was effective for improving short physical performance and had a positive effect on bone mineral density and parathyroid hormone. With aging, women have decreased muscle strength and bone density and therefore, it is strongly recommended that women need to carry out continuous physical activity to prevent disease and ensure a healthy retirement.

Anti-climacterium Effects of Gagamguibiondam-tang in Ovariectomized Rats (난소적출로 유발된 랫트 갱년기 장애에 대한 가감귀비온담탕의 생리활성 효과 평가)

  • Han, Sang-Gyeom;Kim, Dong-Chul
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.30 no.4
    • /
    • pp.18-44
    • /
    • 2017
  • Purpose: The object of this study was to observe the anti-climacterium activity of Gagamguibiondam-tang (GGOT) on ovariectomized (OVX) rats, a well-documented rodent models resembles with women postmenopausal climacterium symptoms, as including cardiovascular diseases, obesity, hyperlipidemia, osteoporosis, organ steatosis and mental disorders. Methods: In this study, anti-climacteric effects were evaluated separated into three categories; 1) anti-obese, 2) anti-uterine atrophy and 3) anti-osteoporotic effects. Five groups were used (8 rats in each group); sham control, OVX control, GGOT 500, 250 and 125 mg/kg administered groups. Twenty-eight days after bilateral OVX surgery, GGOT were orally administered, once a day for 84 days, and then the changes on the body weight and gain during experimental periods, serum estradiol levels, abdominal fat pad and uterus weights with histopathology of abdominal fat pads (total thickness and mean adipocyte diameters) and uterus (total, epithelial and mucosal thickness, percentages of uterine gland regions) for anti-obese and estrogenic effects. In addition, femur, tibia and fourth or fifth lumbar vertebrae (L4 or L5) wet, dry and ash weights, mineral density (BMD), bone strength (failure load), serum osteocalcin and bone specific alkaline phosphatase (bALP) contents, histological and histomorphometrical analyses - bone mass and structure with bone resorption, were monitored for anti-osteoporosis activity. Results: As a result of OVX, noticeable increases of body weight and gains, food and water consumption, weights of abdominal fat pad deposited in dorsal abdominal cavity, serum osteocalcin levels were demonstrated in this experiment with decrease of uterus, femur, tibia and L5 weights, serum bALP and estradiol levels. In addition, marked hypertrophic changes of adipocytes located in deposited abdominal fat pads, uterine disused atrophic changes, decreases of bone mass and structures of femur, tibia and L4 were also observed in OVX control rats with dramatic increases of bone resorption markers, the Ocn and OS/BS at histopathological and histomorphometrical analysis in this study as compared with sham-operated control rats, suggesting the estrogen-deficient climacterium symptoms - obese and osteoporosis were induced by OVX, respectively. However, these estrogen-deficient climacterium symptoms induced by bilateral OVX in rats were significantly inhibited by 84 days of continuous oral treatment of GGOT 500, 250 and 125 mg/kg, respectively. Especially, GGOT 500, 250 and 125 mg/kg showed clear dose-dependent inhibitory activities on the OVX-induced climacterium signs. Conclusion: The results suggest that oral administration of GGOT 500, 250 and 125 mg/kg has clear dose-dependent favorable anti-climacterium effects - estrogenic, anti-obese and anti-osteoporotic activities in OVX rats in this experiment.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF