• Title/Summary/Keyword: Low-contrast Image

Search Result 449, Processing Time 0.028 seconds

Clinical Evaluation for System Performance of Image Intensifiers (상강화기의 임상평가)

  • Kim, Chang-Seon;Charles R. Wilson
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.143-154
    • /
    • 1998
  • The image intensifier is the key component which determines the imaging characteristics in a fluoroscopic imaging system. A system performance program for clinical evaluation of two image intensifiers, that is simple, non-invasive and time effective, was described. Tests were grouped into three headings: x-ray generator, image quality, and collimation. For the x-ray generator, the kVp accuracy and the automatic exposure control operation were compared. Low- and high-contrast resolution measurements, and mesh pattern study belong to the image quality tests and those tests were performed for the video monitor and photospot images. For the collimation, usable field diameter and image distortion of image intensifiers were measured and quantified. The procedures and the results are hoped to be used for the clinical evaluation of system performance and/or acceptance tests for image intensifiers.

  • PDF

A Study on the construction of Low-Frequency Acoustic Microscope and Its Application (저주파대 음향 현미경의 구성과 그 응용에 관한 연구)

  • Ko, Dae-Sik;Moon, Geon;Jun, Kye-Suk;Whang, Keum-Chan
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.5
    • /
    • pp.580-585
    • /
    • 1988
  • In this paper, a low frequency acoustic microscope system has been built for the purpose of detecting subsurface defects in materials. The lateral resolution of acoustic microscope is studied and analyzed in order to evaluate that system performance. And a NDE technique is demonstrated by using this system. In the focused and defocused mode of operation, the acoustic microscope system showed in experiment that its lateral resolution was about 0.5 mm at a frequency of operation of 3MHz on a fused-quartz sample with seeded circular cracks ranged in size from 0.2 mm to 1.0 mm in diameter wihtin 1 mm of the surface. It also showed the acoustic image of 100 won coin with fine contrast.

  • PDF

Hepatic Lymphoma Representing Iso-Signal Intensity on Hepatobiliary Phase, in Gd-EOB-DTPA-Enhanced MRI: Case Report

  • Ahn, Tae-Ran;Kim, Yeo-Eun;Park, Chul-Hi;Jung, Eun-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.200-204
    • /
    • 2015
  • Image findings of hepatic lymphoma have been reported as variable, ranging from single or multiple small nodules to diffuse infiltrative patterns. On MRI, most hepatic lymphomas show T1 low signal intensity, T2 high signal intensity. Dynamic imaging reveals a hypointense appearance in the arterial phase, followed by delayed enhancement in the portal venous and transitional phase. In the hepatobiliary phase using a hepatocyte-specific contrast agent (which have recently aided in increasing the access to the focal liver lesions), hepatic lymphoma is known to exhibit low signal intensity. We report a case of hepatic lymphoma, which shows iso-signal intensity on hepatobiliary phase, using gadoxetic acid (Gd-EOB-DTPA).

X-Ray Spectrum Modulation for Mammography (X-선 스펙트럼 변조 기술 연구)

  • Kim, Gwang-Hyeon;Kim, Gyeong-Rak;O, Chang-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.600-603
    • /
    • 2003
  • Energy spectrum modulation of X-ray source in digital mammography has been studied. In this study, we calculated various filtered spectra using the scattering data. Primary spectra were generated by Molybdenum (Mo) and Tungsten (W) targets. The materials of added filters are Molybdenum and Rhodium (Rh) for 40 kVp Mo. primary spectrum, the amounts of photons over whole energy ranges are attenuated to 0.43 with 0.03 mm Mo filter and 0.38 with 0.06 mm Mo filter while the photons of energy ranged from 17 keV to 20 keV. The photons of low energy ranged below 17 keV are considerably attenuated. This effect brings out reducing the scattered radiation and dose to the patient, and enhancing subject contrast in the image. The results show that filtered spectra are not seriously affected by X-ray tube loadability. Because the energy range from 17 keV to 20 keV is directly transmitted although low and high energies are mainly filtered.

  • PDF

Three-Dimensional Photon Counting Imaging with Enhanced Visual Quality

  • Lee, Jaehoon;Lee, Min-Chul;Cho, Myungjin
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.3
    • /
    • pp.180-187
    • /
    • 2021
  • In this paper, we present a computational volumetric reconstruction method for three-dimensional (3D) photon counting imaging with enhanced visual quality when low-resolution elemental images are used under photon-starved conditions. In conventional photon counting imaging with low-resolution elemental images, it may be difficult to estimate the 3D scene correctly because of a lack of scene information. In addition, the reconstructed 3D images may be blurred because volumetric computational reconstruction has an averaging effect. In contrast, with our method, the pixels of the elemental image rearrangement technique and a Bayesian approach are used as the reconstruction and estimation methods, respectively. Therefore, our method can enhance the visual quality and estimation accuracy of the reconstructed 3D images because it does not have an averaging effect and uses prior information about the 3D scene. To validate our technique, we performed optical experiments and demonstrated the reconstruction results.

The Effects of Perception of Body Shape, Self-esteem, Body Cathexis, and Body Image on Fashion Leadership by Korean and Japanese Female College Students (한국과 일본여대생의 체형인식과 자아존중감, 신체만족도 및 신체이미지가 유행선도력에 미치는 영향)

  • Jeong, Su-Jin;Sato, Mariko;Chu, Mi-Seon
    • Fashion & Textile Research Journal
    • /
    • v.15 no.5
    • /
    • pp.713-721
    • /
    • 2013
  • This study compares the perceived body image of female college students in Korea and Japan as well as explains the difference in the level of self-esteem, body cathexis, body image and fashion leadership based on nationality and body. The sense of fashion leadership affected by these factors was also analyzed. A high ratio of Korean and Japanese female students perceived themselves as obese compared to actual body physique. It was shown that body was highly distorted. They showed a comparatively low level of satisfaction with appearance in contrast to their high interest in their appearance and weight. Thin bodied individuals showed a high level of self-esteem and body cathexis; however, persons with an obese body showed a low level of body cathexis. They showed high interest in appearance regardless of body physique; however, they remain unsatisfied with their appearance. Individuals with an obese body and a standard somatotype showed a high concern with weight. A high fashion opinion leadership was reciprocal to a high interest in appearance and satisfaction with appearance. Korean female students showed an indirect positive effect on fashion opinion leadership through body cathexis, self-esteem, interest in appearance, and satisfaction with appearance. A thin body showed a positive effect on fashion opinion leadership and an obese body had a negative effect. Fashion innovativeness was directly influenced persons with a high degree of self-esteem and interest in appearance. Japanese female students were directly affected by fashion innovativeness; however, Korean female students were indirectly affected by fashion innovativeness through self-esteem and interest in appearance.

Evaluation of ROC Curve in High Kilovoltage Technique Using Simulated Nodules on Chest (고관전압 흉부촬영의 가상결절을 이용한 ROC평가)

  • Ahn, Jin-Shin;Chang, Myung-Mi;Chung, Kyung-Mo;Cheung, Hwan;Lim, Jung-Ki;Kim, Jong-Hyo
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.25-30
    • /
    • 1992
  • With transmitted dose through chest which has the problem of wide variations in absorption, simple film/screen combination method makes it diffucult to image lung field, mediastinum and retrocardiac areas. In order to overcome this, it is very common to use the high kilovoltage technique in diminishing the differences between high and low contrast. We have been adopting this method at department of diagnostic radiology, Seoul National University Hospital. To compare the image of it with that of low kilovoltage technique, we did radiographic tests using beans on the skin. We marked off into three anatomical categories such as lungs, mediastinum and near diaphragm, then attached a bean on a marked area at random. In order to compare with high and low, we took a radiography of high($120{\sim}140\;kVp$) and low($70{\sim}90\;kVp$) kilovoltage tehchniques, respectively at the same time. We have done experiments 320 cases. We evaluated the results of test in response to sensitivity(true positive) and specificity(true negative). In evaluating, we gave them points from 1 to 5 according to true or false. With given points by a radiologist having much experiences, we could acquire the percentage of sensitivity and specificity. The percentage made us to get the schematic table of ROC curve of those two methods. Consequently, high kilovoltage technique appeared 18% better than low kilovoltage technique for detecting beans with our apparatus.

  • PDF

Anisotropic Total Variation Denoising Technique for Low-Dose Cone-Beam Computed Tomography Imaging

  • Lee, Ho;Yoon, Jeongmin;Lee, Eungman
    • Progress in Medical Physics
    • /
    • v.29 no.4
    • /
    • pp.150-156
    • /
    • 2018
  • This study aims to develop an improved Feldkamp-Davis-Kress (FDK) reconstruction algorithm using anisotropic total variation (ATV) minimization to enhance the image quality of low-dose cone-beam computed tomography (CBCT). The algorithm first applies a filter that integrates the Shepp-Logan filter into a cosine window function on all projections for impulse noise removal. A total variation objective function with anisotropic penalty is then minimized to enhance the difference between the real structure and noise using the steepest gradient descent optimization with adaptive step sizes. The preserving parameter to adjust the separation between the noise-free and noisy areas is determined by calculating the cumulative distribution function of the gradient magnitude of the filtered image obtained by the application of the filtering operation on each projection. With these minimized ATV projections, voxel-driven backprojection is finally performed to generate the reconstructed images. The performance of the proposed algorithm was evaluated with the catphan503 phantom dataset acquired with the use of a low-dose protocol. Qualitative and quantitative analyses showed that the proposed ATV minimization provides enhanced CBCT reconstruction images compared with those generated by the conventional FDK algorithm, with a higher contrast-to-noise ratio (CNR), lower root-mean-square-error, and higher correlation. The proposed algorithm not only leads to a potential imaging dose reduction in repeated CBCT scans via lower mA levels, but also elicits high CNR values by removing noisy corrupted areas and by avoiding the heavy penalization of striking features.

Recognition of Car License Plate Using Geometric Information from Portable Device Image (휴대단말기 영상에서의 기하학적 정보를 이용한 차량 번호판 인식)

  • Yeom, Hee-Jung;Eun, Sung-Jong;WhangBo, Taeg-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.10
    • /
    • pp.1-8
    • /
    • 2010
  • Recently, the character image processing technology using portable device camera image at home and abroad are actively conducted, but Practical use are lower rate because of accuracy and time-consuming process problems. In this paper, we propose the license plate recognition method based on geometric information from portable device camera image. In the extracted license plate region we recognize characters using the chain code and the Thickness information through the cumulative projected edge after performing the pre-processing work considering the angle difference, the contrast enhancement and the low resolution from portable device camera image. The proposed algorithm is effective and accurate recognition by light and reducing the processing time. And, the results from the character recognition success rate was 95%. In the future, we will research about license plate recognition algorithm using long distance image or added motion blur image.

Area based image matching with MOC-NA imagery (MOC-NA 영상의 영역기준 영상정합)

  • Youn, Jun-Hee;Park, Choung-Hwan
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.4
    • /
    • pp.463-469
    • /
    • 2010
  • Since MOLA(Mars Orbiter Laser Altimeter) data, which provides altimetry data for Mars, does not cover the whole Mars area, image matching with MOC imagery should be implemented for the generation of DEM. However, automatic image matching is difficult because of insufficient features and low contrast. In this paper, we present the area based semi-automatic image matching algorithm with MOC-NA(Mars Orbiter Camera ? Narrow Angle) imagery. To accomplish this, seed points describing conjugate points are manually added for the stereo imagery, and interesting points are automatically produced by using such seed points. Produced interesting points being used as initial conjugate points, area based image matching is implemented. For the points which fail to match, the locations of initial conjugate points are recalculated by using matched six points and image matching process is re-implemented. The quality assessment by reversing the role of target and search image shows 97.5 % of points were laid within one pixel absolute difference.