• 제목/요약/키워드: Low load

검색결과 3,882건 처리시간 0.032초

COMBUSTION STABILITY OF DIESEL-FUELED HCCI

  • Shi, L.;Deng, K.;Cui, Y.
    • International Journal of Automotive Technology
    • /
    • 제8권4호
    • /
    • pp.395-402
    • /
    • 2007
  • Homogeneous Charge Compression Ignition (HCCI) shows great potential for low $NO_x$ emission but is hampered by the problem of no direct method to control the combustion process. Therefore, HCCI combustion becomes unstable easily, especially at lower and higher engine load. This paper presents a method to achieve diesel-fueled HCCI combustion, which involves directly injecting diesel fuel into the cylinder before the piston arrives at top dead center in the exhaust stroke and adjusting the valve overlap duration to trap more high temperature residual gas in the cylinder. The combustion stability of diesel-fueled HCCI combustion and the effects of engine load, speed, and valve overlap on it are the main points of investigation. The results show that: diesel-fueled HCCI combustion has two-stage heat release rate (low temperature and high temperature heat release) and very low $NO_x$ emission, combustion stability of the HCCI engine is worse at lower load because of misfire and at higher load because of knock, the increase in engine speed aids combustion stability at lower load because the heat loss is reduced, and increasing negative valve overlap can increase in-cylinder temperature which aids combustion stability at lower load but harms it at higher load.

저압 모의선로에 소형발전원 연계시 특성 (Connected Characteristics for Small Generation Source of Low Voltage Model Grids)

  • 이상우;강진규;이동하;박태준
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.45-53
    • /
    • 2013
  • In this paper, we analyze the typical phase voltage and line current waveform characteristics of the distribution system with 3 phase small synchronous generation source in case with load and non-load group, in order to investigate the power quality for end load connected of generation source. As demonstrated by our experimental results, the distortion and power quality of phase voltage and line current waveform were relatively good for low voltage 3 phase model grids connected of 3 phase small synchronous generation source in case with non-load group. However, distortion and power quality of voltage and current waveform was poor for low voltage 3 phase model grids connected to 3 phase small synchronous generation source in the load group with some phase voltage and frequency difference. From the above results, we conclude that the phase voltage and frequency of 3 phase generation source must be identical to that of distribution system source to maximize the power quality. Also, special attention is required in case of having load group or non-load group to 3 phase generation source.

Heating and Cooling Load of Building according to Atrium Layout

  • Jeong, Nam-Young;Lee, Ji-Young;Chae, Young Tae
    • KIEAE Journal
    • /
    • 제16권1호
    • /
    • pp.29-36
    • /
    • 2016
  • Purpose: The purpose of this study is to present basic data which would be applied on the early stage of the architectural design. And that determines the introduction of the atrium by comparing and analysing the environmental performance of atrium building. Method: The building forms are classified into low storied building, middle storied building and high storied building. This study compares and analyses energy performance of the standard building without atrium and the atrium building which has one-side, two-side, three-side, four-side, and linear atrium by measuring of annual heating and cooling load with EnergyPlus. Result: As a result of the analysis of the relative annual heating and cooling load by building type, it is shown that the fluctuation of cooling load in low storied building is large because heat storage in atrium affects building, and the fluctuation of heating load in high storied building is large owing to the effect of external wall area of atrium which makes heat loss. Especially, it indicated the largest annual heating and cooling load in four-side atrium of low storied building, and in one-side atrium of high storied building.

변압기 효율 적정화를 위한 변압기 부하율 조사 및 추정 (Investigation and Estimation of Transformer Load Factor for Rationalization of Transformer's Efficiency)

  • 김종민;김영석;길형준;송길목
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.96-101
    • /
    • 2016
  • In this paper, We investigate the number of 795 transformer in the private electrical facilities and analyze the annual load factor. The results show that the annual load factor of transformer is 20.16% in manufacturing industry, education services(school) is 9.59%, retail and wholesale services is 19.68%, resort and leisure industry is 10.93%, office building is 13.10%, and apartment houses is 14.69%. Education services, resort and leisure industry are being operated with a very low annual load factor. The relatively small capacity of less than 500kVA transformer also been analyzed that is being operated with a low load factor. Therefore, In order to minimize the power loss of the transformer, it is advisable to complement the Transformer Efficiency Management system to be designed the efficiency is good transformer when the load is low. Analysis results will be used as the basis for the provision of transformer efficiency management system and be used High-efficiency transformers promotion system.

요통을 가진 대상자에 있어 전방으로 굴곡된 자세 및 갑작스런 부하가 균형 수행력에 미치는 영향 (The Effects of Balance Performance to Forward Bending Posture and Sudden Load in Subjects with Low Back Pain)

  • 채윤원;이해정;박지원
    • The Journal of Korean Physical Therapy
    • /
    • 제17권3호
    • /
    • pp.413-420
    • /
    • 2005
  • The purpose of this study was to determine differences of balance performance to upright standing, forward bending posture, and sudden load during forward bending posture in subjects with and without a history of low back pain. A study was conducted on 8 subjects with low back pain and 13 healthy subjects. Dynamic Balance System was used to measure the postural sway index, left-right sway index, and anterior-posterior sway index on balance performance. There were no differences between subject groups on balance performance during upright standing. Balance performance was increased in forward bending posture and decreased in sudden load during forward bending posture in subjects with low back pain. These results suggest that subjects with low back pain demonstrated increased activity and decreased reaction times of trunk muscles.

  • PDF

Low Frequency Current Ripple Mitigation of Two Stage Three-Phase PEMFC Generation Systems

  • Deng, Huiwen;Li, Qi;Liu, Zhixiang;Li, Lun;Chen, Weirong
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2243-2257
    • /
    • 2016
  • This paper presents a two stage three-phase proton exchange membrane fuel cell (PEMFC) generation system. When the system is connected to a three-phase load, it is very sensitive to the characteristics and type of the load. Especially unbalanced three-phase loads, which result in a pulsating power that is twice the output frequency at the inverter output, and cause the dc-link to generate low frequency ripples. This penetrates to the fuel cell side through the front-end dc-dc converter, which makes the fuel cell work in an unsafe condition and degrades its lifespan. In this paper, the generation and propagation mechanism of low frequency ripple is analyzed and its impact on fuel cells is presented based on the PEMFC output characteristics model. Then a novel method to evaluate low frequency current ripple control capability is investigated. Moreover, a control scheme with bandpass filter inserted into the current feed-forward path, and ripple duty ratio compensation based on current mode control with notch filter is also proposed to achieve low frequency ripple suppression and dynamic characteristics improvement during load transients. Finally, different control methods are verified and compared by simulation and experimental results.

A High Current Efficiency CMOS LDO Regulator with Low Power Consumption and Small Output Voltage Variation

  • Rikan, Behnam Samadpoor;Abbasizadeh, Hamed;Kang, Ji-Hun;Lee, Kang-Yoon
    • 전기전자학회논문지
    • /
    • 제18권1호
    • /
    • pp.37-44
    • /
    • 2014
  • In this paper we present an LDO based on an error amplifier. The designed error amplifier has a gain of 89.93dB at low frequencies. This amplifier's Bandwidth is 50.8MHz and its phase margin is $59.2^{\circ}C$. Also we proposed a BGR. This BGR has a low output variation with temperature and its PSRR at 1 KHz is -71.5dB. For a temperature variation from $-40^{\circ}C$ to $125^{\circ}C$ we have just 9.4mV variation in 3.3V LDO output. Also it is stable for a wide range of output load currents [0-200mA] and a $1{\mu}F$ output capacitor and its line regulation and especially load regulation is very small comparing other papers. The PSRR of proposed LDO is -61.16dB at 1 KHz. Also we designed it for several output voltages by using a ladder of resistors, transmission gates and a decoder. Low power consumption is the other superiority of this LDO which is just 1.55mW in full load. The circuit was designed in $0.35{\mu}m$ CMOS process.

불평형 전압으로 운전시 비선형 부하에 나타나는 현상 (The Phenomena Giving Rise of Nonlinear Load Operated by Unbalance Voltage)

  • 김종겸;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권6호
    • /
    • pp.285-291
    • /
    • 2002
  • In general, utility voltage is maintained at a relatively low level of Phase unbalance since a low level of unbalance can cause a significant power supply ripple and heating effects on the power system equipment. Voltage unbalance more commonly emerges in individual customer loads due to phase load unbalanced, especially where single phase power loads are used. Under unbalanced input voltages large lower order harmonics appears at the input and output ports of Power conversion devices. As the application of adjustable -speed drives (ASDs) and their integration with complex industrial processes increase, so does the need to understand how ASDs perform during voltage This paper describes a real load test to investigate the performance of 3-HP adjustable speed drives by an unbalanced voltage at the low-voltage system.

지지조건을 고려한 낮은 포물선 아치의 동적 임계하중의 해석 (An Analysis of Dynamic Critical Loads for Low Parabolic Arches with Different End Conditions)

  • 박승범
    • 한국농공학회지
    • /
    • 제28권2호
    • /
    • pp.87-92
    • /
    • 1986
  • The differential equation, which can determine the dynamic critical loads for low parabcoic arches, is derived in this study. The dynamic critical loads of the parabolic arches subjected to a concentrated step load are nummerically analyzed for the changes of load positions. In cases of arches with different end conditions (both hinged, fixed hinged, both fixed), the effect of end conditions and that of the rises are investigated in detail. The summary of the results are the following: 1)The snapthrough does not occur when the rise of arch is very low, and the bifurcation appears clearly as the rise of arch increases. 2)The regions in which the dynamic critical loads are not defined for the both ends fixed are broader than that for the both ends hinged. 3)For all case, the load positions of minimum dynamic critical loads exsit at the near position from the end hinged. Thus, the results obtained in present study show that the magnitude of dynamic critical loads, the load positions of minimum dynamic critical loads and the regions in which the dynamic critical loads are not defined depend on end conditions of arches.

  • PDF

An Analysis on Building Shading Plan for a City Hall considering Energy Saving

  • Kim, Jin Lee;No, Sang Tae
    • KIEAE Journal
    • /
    • 제16권2호
    • /
    • pp.5-10
    • /
    • 2016
  • Purpose: Recently, many public office buildings which were built by curtain wall increased rapidly, but the results of the investigation of the government, these buildings have been found that the heating and cooling thermal load is high, and showed low energy efficiency. Method: To evaluate the effects by applying outdoor louver and indoor blind, which can control solar radiation in order to reduce the heating and cooling load of public office building which was built by glass curtain wall. The heating and cooling load was calculated via Energyplus, building and outdoor louver, indoor blind were modeled by Google sketchup connected to Energyplus. Result: The results of this study were as follows; the case of applying various outdoor louver, the heating and cooling load all decreased as compared to the case without applying outdoor louver, the case of applying indoor blind, the heating and cooling load decreased as compared to the case without applying indoor blind, but indoor blind showed low energy performance comparing outdoor louver.