• 제목/요약/키워드: Low level radiation

검색결과 432건 처리시간 0.024초

CHARACTERISTICS OF LOW LEVEL TEMPERATURE INVERSION IN TAIWAN

  • Liou Yuei-An;Yan Shiang-Kun
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.38-41
    • /
    • 2005
  • The observation data from MTP-5HE ofEPA are used to study the temperature inversion phenomenon in the lower boundary layer in Taipei, Taichung and Kaohsiung of Taiwan. Characteristics of temperature inversion at three cities are extracted using different classification methods. The characteristics of temperature inversion in Taichung and Kaohsiung show a similar trend but are different from that in Taipei. The numbers of the occurrence of temperature inversion in Taichung and Kaohsiung were much larger than that in Taipei. The main types of temperature inversion in Taiwan are radiation inversion and frontal inversion. Compared to frontal inversion, radiation inversion on average occurs at a lower altitude, lasts a longer period, has a deeper thickness, and reaches a higher temperature difference of inversion. Frontal inversion plays a significant role for the inversion event lasting over 12 hours.

  • PDF

An Accidental over Exposure in Mednif Tele-Cobalt Machine in Nepal

  • chaurasia, P.P.;Srivastava, R.P.;Prasiko, G.;Neupane, B.P.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.97-99
    • /
    • 2002
  • A radiation incident took place during treatment on MEDNIF Tele cobalt-60 therapy machine in B.P.KOIRALA MEMORIAL CANCER HOSPITAL in Bharatpur, Nepal. This Chinese made machine has activity of 6240 Curies of cobalt -60. This machine has fulfilled safety requirements. ICRP recommendations, safety rules are followed and practiced. The source was struck up during treatment and a technician was exposed to equivalent dose of 13.75 mSv. recorded by Personal film badge. Risks of workers are comparable to other safe industries. All exposures shall be kept as low as reasonably possible. The higher level of safety is achieved only when every one is dedicated to common goal. A lesson is learnt for future. Good practice is essential but not sufficient. A high demand for tele Cobalt therapy convinced management to replace Mednif machine with a new efficient Elite Tele Cobalt theratron Machine.

  • PDF

Monte Carlo simulations of chromium target under proton irradiation of 17.9, 22.3 MeV

  • Kara, A.;Yilmaz, A.;Yigit, M.
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3158-3163
    • /
    • 2021
  • Chromium material is commonly used for fusion plasma facing applications because of the low neutron activation property. The Monte Carlo method is one of the useful ways to investigate the ion-target interactions. In this study, Chromium target irradiated by protons was investigated using Monte Carlo based simulation tools. In this context, the calculations of radiation damage on Chromium material irradiated with protons at 17.9 and 22.3 MeV energies were carried out using GEANT4 and SRIM codes. Besides, the cross sections for proton interaction with Chromium target were calculated by the TALYS 1.9 code using CTM + FGM, BSFGM, and GSFM level densities. As a result, GEANT4, SRIM and TALYS 1.9 codes provide a suitable tool for the predictions of radiation damage and cross cross section with proton irradiation.

Radiation Exposure Reduction in APR1400

  • Bae, C.J.;Hwang, H.R.;Matteson, D.M.
    • Journal of Radiation Protection and Research
    • /
    • 제28권2호
    • /
    • pp.127-135
    • /
    • 2003
  • The primary contributors to the total occupational radiation exposure in operating nuclear power plants are operation and maintenance activities doting refueling outages. The Advanced Power Reactor 1400 (APR1400) includes a number of design improvements and plans to utilize advanced maintenance methods and robotics to minimize the annual collective dose. The major radiation exposure reduction features implemented in APR1400 are a permanent refueling pool seal, quick opening transfer tube blind flange, improved hydrogen peroxide injection at shutdown, improved permanent steam generator work platforms, and more effective temporary shielding. The estimated average annual occupational radiation exposure for APR1400 based on the reference plant experience and an engineering judgment is determined to be in the order of 0.4 man-Sv, which is well within the design goal of 1 man-Sv. The basis of this average annual occupational radiation exposure estimation is an eighteen (18) month fuel cycle with maintenance performed to steam generators and reactor coolant pumps during refueling outage. The outage duration is assumed to be 28 days. The outage work is to be performed on a 24 hour per day basis, seven (7) days a week with overlapping twelve (12) hour work shifts. The occupational radiation exposure for APR1400 is also determined by an alternate method which consists of estimating radiation exposures expected for the major activities during the refueling outage. The major outage activities that cause the majority of the total radiation exposure during refueling outage such as fuel handling, reactor coolant pump maintenance, steam generator inspection and maintenance, reactor vessel head area maintenance, decontamination, and ICI & instrumentation maintenance activities are evaluated at a task level. The calculated value using this method is in close agreement with the value of 0.4 man-Sv, that has been determined based on the experience aid engineering judgement. Therefore, with the As Low As Reasonably Achievable (ALARA) advanced design features incorporated in the design, APR1400 design is to meet its design goal with sufficient margin, that is, more than a factor of two (2), if operated on art eighteen (18) month fuel cycle.

서로 다른 매질을 갖는 격실사이의 음파전달해석 (An Analysis of the Sound Propagation between Rooms with Different Mediums)

  • 김현실;김재승;이성현;서윤호
    • 한국음향학회지
    • /
    • 제32권5호
    • /
    • pp.402-407
    • /
    • 2013
  • 본 논문은 인접한 두 격실의 매질이 다를 때 공통 벽을 통한 음파의 전파를 해석한 내용을 다루었다. 통계적 에너지해석법(statistical energy energy)을 사용하여 두 격실의 음향에너지와 벽의 진동에너지간의 에너지 평형을 고려하였으며 소음원실의 음압이 벽을 투과하는 성분 외에 벽의 구조소음으로 인한 음의 방사(radiation)가 수음원실의 음압에 미치는 영향을 검토하였다. 예제로 선박의 엔진실과 물탱크가 크기 $8.4{\times}4$ m인 강판을 사이에 두고 접한 경우를 해석하였다. 강판의 임계주파수(critical frequency)가 관심주파수대역보다 큰 경우 63 Hz이하의 저주파수대역을 제외하고 음파의 전달은 강판을 투과하는 성분에 의해 주로 결정되며 강판의 구조소음에 기인한 방사소음은 무시할 정도로 기여도가 작음을 확인하였다.

휴대용 검출기의 방사선 고감도 검출을 위한 SiPM 특성 분석 (Characteristics Analysis of SiPM for Detection of High Sensitivity of Portable Detectors)

  • 강병욱;유선국
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.897-902
    • /
    • 2023
  • 본 논문에서는 휴대용 X-ray 검출기의 방사선 고감도 검출에 대한 실현 가능 여부를 확인하기 위한 SiPM의 특성 분석을 목적으로 한다. 휴대용 X-ray 검출기는 환자의 위치에 빠르게 접근하여 실시간 이미지를 획득함으로써 의사들은 신속하게 진단을 수행할 수 있는 장점이 있지만 이러한 이동성은 선량 감지의 어려움을 동반한다. 기존 검출기에서는 SiPM을 X-ray Trigger를 판별하는 단순한 용도로 사용하고 있다. SiPM을 통한 X-ray의 고감도 검출 가능 여부를 확인하기 위해 7종의 SiPM Sensor를 비교 선정하고 특성 분석을 진행하였다. 최종 시험에 사용한 SiPM은 10 nGy 수준의 극저선량 조사 조건에서 Signal 구분이 가능하며, 관전압에 따라 Signal 상승곡선의 기울기가 변하는 것이 확인되었다. X-ray 선량에 따라 SiPM의 signal level 및 지속시간이 변화되는 특성을 이용한 고감도 측정이 가능할 것으로 보인다.

Delayed Diagnosis of Probable Radiation Induced Spinal Cord Vascular Disorders

  • Won, Young Il;Kim, Chi Heon;Chung, Chun Kee;Yun, Tae Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권3호
    • /
    • pp.215-218
    • /
    • 2015
  • Occasionally, unexpected neurological deficits occur after lumbar spinal surgery. We report a case of monoparesis after lumbar decompressive surgery. A 63-year-old man, who had undergone decompression of L4-5 for spinal stenosis 4 days previously in the other hospital, visted the emergency department with progressive weakness in the left leg and hypoesthesia below sensory level T7 on the right side. He had been cured of lung cancer with chemotherapy and radiation therapy 10 years previously, but detailed information of radiotherapy was not available. Whole spine magnetic resonance (MR) imaging showed fatty marrow change from T1 to T8, most likely due to previous irradiation. The T2-weighted MR image showed a high-signal T4-5 spinal cord lesion surrounded by a low signal rim, and the T1-weighted MR image showed focal high signal intensity with focal enhancement. The radiological diagnosis was vascular disorders with suspicious bleeding. Surgical removal was refused by the patient. With rehabilitation, the patient could walk independently without assistance 2 months later. Considering radiation induced change at thoracic vertebrae, vascular disorders may be induced by irradiation. If the spinal cord was previously irradiated, radiation induced vascular disorders needs to be considered.

Multi-Level Segmentation of Infrared Images with Region of Interest Extraction

  • Yeom, Seokwon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제16권4호
    • /
    • pp.246-253
    • /
    • 2016
  • Infrared (IR) imaging has been researched for various applications such as surveillance. IR radiation has the capability to detect thermal characteristics of objects under low-light conditions. However, automatic segmentation for finding the object of interest would be challenging since the IR detector often provides the low spatial and contrast resolution image without color and texture information. Another hindrance is that the image can be degraded by noise and clutters. This paper proposes multi-level segmentation for extracting regions of interest (ROIs) and objects of interest (OOIs) in the IR scene. Each level of the multi-level segmentation is composed of a k-means clustering algorithm, an expectation-maximization (EM) algorithm, and a decision process. The k-means clustering initializes the parameters of the Gaussian mixture model (GMM), and the EM algorithm estimates those parameters iteratively. During the multi-level segmentation, the area extracted at one level becomes the input to the next level segmentation. Thus, the segmentation is consecutively performed narrowing the area to be processed. The foreground objects are individually extracted from the final ROI windows. In the experiments, the effectiveness of the proposed method is demonstrated using several IR images, in which human subjects are captured at a long distance. The average probability of error is shown to be lower than that obtained from other conventional methods such as Gonzalez, Otsu, k-means, and EM methods.

Study on Dose Rate on the Surface of Cask Packed with Activated Cut-off Pieces from Decommissioned Nuclear Power Plant

  • Park, Kwang Soo;Kim, Hae Woong;Sohn, Hee Dong;Kim, Nam Kyun;Lee, Chung Kyu;Lee, Yun;Lee, Ji Hoon;Hwang, Young Hwan;Lee, Mi Hyun;Lee, Dong Kyu;Jung, Duk Woon
    • Journal of Radiation Protection and Research
    • /
    • 제45권4호
    • /
    • pp.178-186
    • /
    • 2020
  • Background: Reactor pressure vessel (RV) with internals (RVI) are activated structures by neutron irradiation and volume contaminated wastes. Thus, to develop safe and optimized disposal plan for them at a disposal site, it is important to perform exact activation calculation and evaluate the dose rate on the surface of casks which contain cut-off pieces. Materials and Methods: RV and RVI are subjected to neutron activation calculation via Monte Carlo methodology with MCNP6 and ORIGEN-S program-neutron flux, isotopic specific activity, and gamma spectrum calculation on each component of RV and RVI, and dose rate evaluation with MCNP6. Results and Discussion: Through neutron activation analysis, dose rate is evaluated for the casks containing cut-off pieces produced from decommissioned RV and RVI. For RV cut-off ones, the highest value of dose rate on the surface of cask is 6.97 × 10-1 mSv/hr and 2 m from it is 3.03 × 10-2 mSv/hr. For RVI cut-off ones, on the surface of it is 0.166 × 10-1 mSv/hr and 2 m from it is 1.04 × 10-1 mSv/hr. Dose rates for various RV and RVI cut-off pieces distributed lower than the limit except the one of 2 m from the cask surface of RVI. It needs to adjust contents in cask which carries highly radioactive components in order to decrease thickness of cask. Conclusion: Two types of casks are considered in this paper: box type for very-low-level waste (VLLW) as well as low-level waste (LLW) and cylinder type for intermediate-level waste (ILW). The results will contribute to the development of optimal loading plans for RV and RVI cut-off pieces during the decommissioning of nuclear power plant that can be used to prepare radioactive waste disposal plans for the different types of wastes-ILW, LLW, and VLLW.

Effects of Irradiation Temperature on the Sensory Quality Improvement of Gamma-irradiated Ganjang-gejang, Korean Traditional Marinated Raw Crab Portunus trituberculatus in Soybean Sauce

  • Park, Jae-Nam;Byun, Eui-Baek;Han, In-Jun;Song, Beom-Seok;Sohn, Hee-Sook;Park, Sang-Hyun;Byun, Eui-Hong;Yoon, Minchul;Sung, Nak-Yun
    • Fisheries and Aquatic Sciences
    • /
    • 제18권2호
    • /
    • pp.115-121
    • /
    • 2015
  • This study was conducted to confirm quality properties of sterilized Ganjang-gejang (marinated crab Portunus trituberculatus) with Korean soy sauce using by gamma irradiation and to improve quality of sterilized Ganjang-gejang. The Ganjang-gejang was irradiated at dose of 3, 6, 9, 12, and 15 kGy by gamma irradiation and there was evaluated in microbiological, physicochemical, and sensory properties. Total aerobic bacteria and fungi contents of non-irradiated samples were about 6 and 4 log CFU/g level, respectively. Gamma-irradiated samples at above 9 kGy did not contain aerobic bacteria or fungi at detection limit less than 2 log CFU/g, but sensory scores were significantly decreased depending on the irradiation dose. To improve the sensory qualities of gamma-irradiated Ganjang-gejang, the temperature was adjusted during sample irradiation. When samples were irradiated under freezing temperatures, especially on dry ice, the TBARS and the deterioration of sensory qualities of Ganjan-Gejang were reduced. Different odor patterns were observed among samples, as observed using electronic nose analysis system. The results of this study indicated that treatment with irradiation under low temperatures may help to preparing high-quality Ganjang-gejang.