• 제목/요약/키워드: Low emission

검색결과 2,591건 처리시간 0.027초

CBD 공법을 이용하여 Cd2+ 원소 Alloying 시간을 조절한 Cu2Zn1-xCdxSn(SxSe1-x)4 박막 태양전지의 광전지 성능 향상 분석 (Analysis of Photovoltaic Performance Improvement of Cu2Zn1-xCdxSn(SxSe1-x)4 Thin Film Solar Cells by Controlling Cd2+ Element Alloying Time Using CBD Method)

  • 박상우;장수영;장준성;김진혁
    • 한국재료학회지
    • /
    • 제32권11호
    • /
    • pp.481-488
    • /
    • 2022
  • The Cu2ZnSn(SxSe1-x)4 (CZTSSe) absorbers are promising thin film solar cells (TFSCs) materials, to replace existing Cu(In,Ga)Se2 (CIGS) and CdTe photovoltaic technology. However, the best reported efficiency for a CZTSSe device, of 13.6 %, is still too low for commercial use. Recently, partially replacing the Zn2+ element with a Cd2+element has attracting attention as one of the promising strategies for improving the photovoltaic characteristics of the CZTSSe TFSCs. Cd2+ elements are known to improve the grain size of the CZTSSe absorber thin films and improve optoelectronic properties by suppressing potential defects, causing short-circuit current (Jsc) loss. In this study, the structural, compositional, and morphological characteristics of CZTSSe and CZCTSSe thin films were investigated using X-ray diffraction (XRD), X-ray fluorescence spectrometer (XRF), and Field-emission scanning electron microscopy (FE-SEM), respectively. The FE-SEM images revealed that the grain size improved with increasing Cd2+ alloying in the CZTSSe thin films. Moreover, there was a slight decrease in small grain distribution as well as voids near the CZTSSe/Mo interface after Cd2+ alloying. The solar cells prepared using the most promising CZTSSe absorber thin films with Cd2+ alloying (8 min. 30 sec.) exhibited a power conversion efficiency (PCE) of 9.33 %, Jsc of 34.0 mA/cm2, and fill factor (FF) of 62.7 %, respectively.

CORDEX-EA Phase 2 다중 지역기후모델을 이용한 한반도 미래 극한 기후 전망 (Future Projection of Extreme Climate over the Korean Peninsula Using Multi-RCM in CORDEX-EA Phase 2 Project)

  • 김도현;김진욱;변영화;김태준;김진원;김연희;안중배;차동현;민승기;장은철
    • 대기
    • /
    • 제31권5호
    • /
    • pp.607-623
    • /
    • 2021
  • This study presents projections of future extreme climate over the Korean Peninsula (KP), using bias-corrected data from multiple regional climate model (RCM) simulations in CORDEX-EA Phase 2 project. In order to confirm difference according to degree of greenhouse gas (GHG) emission, high GHG path of SSP5-8.5 and low GHG path of SSP1-2.6 scenario are used. Under SSP5-8.5 scenario, mean temperature and precipitation over KP are projected to increase by 6.38℃ and 20.56%, respectively, in 2081~2100 years compared to 1995~2014 years. Projected changes in extreme climate suggest that intensity indices of extreme temperatures would increase by 6.41℃ to 8.18℃ and precipitation by 24.75% to 33.74%, being bigger increase than their mean values. Both of frequency indices of the extreme climate and consecutive indices of extreme precipitation are also projected to increase. But the projected changes in extreme indices vary regionally. Under SSP1-2.6 scenario, the extreme climate indices would increase less than SSP5-8.5 scenario. In other words, temperature (precipitation) intensity indices would increase 2.63℃ to 3.12℃ (14.09% to 16.07%). And there is expected to be relationship between mean precipitation and warming, which mean precipitation would increase as warming with bigger relationship in northern KP (4.08% ℃-1) than southern KP (3.53% ℃-1) under SSP5-8.5 scenario. The projected relationship, however, is not significant for extreme precipitation. It seems because of complex characteristics of extreme precipitation from summer monsoon and typhoon over KP.

안면도 지역 온실기체 기원에 따른 CO/CO2 비율 변동성 분석 연구 (Analysis of CO/CO2 Ratio Variability According to the Origin of Greenhouse Gas at Anmyeon-do)

  • 김재민;이해영;김수민;정주용;김연희;이그림;최경배;이윤곤
    • 대기
    • /
    • 제31권5호
    • /
    • pp.625-635
    • /
    • 2021
  • South Korea established the 2050 Carbon Neutral Plan in response to the climate crisis, and to achieve this policy, it is very important to monitor domestic carbon emissions and atmospheric carbon concentration. Both CO2 and CO are emitted from fossil fuel combustion processes, but the relative ratios depend on the combustion efficiency and the strength of local emission regulations. In this study, the relationship between CO2 and CO was analyzed using ground observation data for the period of 2018~2020 at Anmyeon-do site and the CO/CO2 ratio according to regional origin during high CO2 cases was investigated based on the footprint simulated from Stochastic Time-Inverted Lagrangian Transport (STILT) model. CO2 and CO showed a positive correlation with correlation coefficient of 0.66 (p < 0.01), and averaged footprints during high CO2 cases confirmed that air particles mainly originated from eastern and north-eastern China, and inland of Korean Peninsula. In addition, it was revealed that among the cases of high CO2 concentration, when the CO/CO2 ratio is high, the industrial area of eastern China is greatly affected, and when the ratio is low, the contribution of the domestic region is relatively high. The ratio of CO2 and CO in this study is significant in that it can be used as a useful factor in determining the possibility of domestic and foreign origins of climate pollutants.

4,4'-Methylenedianiline의 환경매체별 위해성평가 (Ecological Risk Assessment of 4,4'-Methylenedianiline)

  • 김현수;이대엽;우경숙;유시은;이인혜;지경희;서정관;조훈제
    • 한국환경보건학회지
    • /
    • 제49권6호
    • /
    • pp.334-343
    • /
    • 2023
  • Background: South Korea's Act on Registration and Evaluation, etc. of Chemicals (known as K-REACH) was established to protect public health and the environment from hazardous chemicals. 4,4'-Methylenedianiline (MDA), which is used as a major intermediate in industrial polymer production and as a vulcanizing agent in South Korea, is classified as a toxic substance under the K-REACH act. Although MDA poses potential ecological risks due to industrial emissions and hazards to aquatic ecosystems, no ecological risk assessment has been conducted. Objectives: The aim of this study is to assess the ecological risk of MDA by identifying the actual exposure status based on the K-REACH act. Methods: Various toxicity data were collected to establish predicted no effect concentrations (PNECs) for water, sediment, and soil. Using the SimpleBox Korea v2.0 model with domestic release statistical data and EU emission factors, predicted environmental concentrations (PECs) were derived for ten sites, each referring to an MDA-using company. Hazard quotient (HQ) was calculated by ratio of the PECs and PNECs to characterize the ecological risk posed by MDA. To validate the results of modeling-based assessment, concentration of MDA was measured using in-site freshwater samples (two to three samples per site). Results: PNECs for water, sediment, and soil were 0.000525 mg/L, 4.36 mg/kg dw, and 0.1 mg/kg dw, respectively. HQ for surface water and sediment at several company sites exceeded 1 due to modeling data showing markedly high PEC in each environmental compartment. However, in the results of validation using in-site surface water samples, MDA was not detected. Conclusions: Through an ecological risk assessment conducted in accordance with the K-REACH act, the risk level of MDA emitted into the environmental compartments in South Korea was found to be low.

한국 ETS시장, 에너지시장 및 주식시장 간의 동태적 상관관계에 관한 연구 (A Study on the Dynamic Correlation between the Korean ETS Market, Energy Market and Stock Market)

  • 양국동;이은화
    • 무역학회지
    • /
    • 제48권4호
    • /
    • pp.189-208
    • /
    • 2023
  • 본 논문은 한국 ETS시장, 에너지시장 및 주식시장 간의 동태적 조건부 상관관계를 분석하였다. 본 논문은 2015년 2월 2일부터 2021년 12월 30일까지의 한국 탄소배출권 거래가격, WTI원유 선물가격, 코스피지수의 일별 자료를 이용하여 실증분석하였다. 우선, GARCH 모형을 사용하여 세 시장의 변동성에 대해 분석한 후, 이변량 DCC-GARCH 모형을 사용하여 세 시장 간의 동태적 조건부 상관관계를 연구하였다. 연구결과는 다음과 같다. 첫째, 한국의 ETS시장이 주식시장보다 투자 수익률과 투자 위험도가 높은 것으로 나타났다. 둘째, 한국 ETS시장의 수익률 변동성이 외부 충격의 영향을 가장 많이 받고, 시장 자체의 변동성 정보로부터 받는 영향이 가장 작은 것으로 나타났다. 셋째, 한국 ETS시장이 WTI원유 선물시장보다 주식시장과의 상관관계의 지속성이 더 강한 것으로 나타났다. 본 논문은 한국 ETS시장, 에너지시장 및 주식시장 간의 상관관계를 분석하여 한국 ETS시장의 금융화 수준이 상당히 낮은 것을 확인하였다.

Optimal flammability and thermal buckling resistance of eco-friendly abaca fiber/ polypropylene/egg shell powder/halloysite nanotubes composites

  • Saeed Kamarian;Reza Barbaz-Isfahani;Thanh Mai Nguyen Tran;Jung-Il Song
    • Advances in nano research
    • /
    • 제16권2호
    • /
    • pp.127-140
    • /
    • 2024
  • Upon direct/indirect exposure to flame or heat, composite structures may burn or thermally buckle. This issue becomes more important in the natural fiber-based composite structures with higher flammability and lower mechanical properties. The main goal of the present study was to obtain an optimal eco-friendly composite system with low flammability and high thermal buckling resistance. The studied composite consisted of polypropylene (PP) and short abaca fiber (AF) with eggshell powder (ESP) and halloysite clay nanotubes (HNTs) additives. An optimal base composite, consisting of 30 wt.% AF and 70 wt.% PP, abbreviated as OAP, was initially introduced based on burning rate (BR) and the Young's modulus determined by horizontal burning test (HBT) and tensile test, respectively. The effects of adding ESP to the base composite were then investigated with the same experimental tests. The results indicated that though the BR significantly decreased with the increase of ESP content up to 6 wt.%, it had a very destructive influence on the stiffness of the composite. To compensate for the damaging effect of ESP, small amount of HNT was used. The performance of OAP composite with 6 wt.% ESP and 3 wt.% HNT (OAPEH) was explored by conducting HBT, cone calorimeter test (CCT) and tensile test. The experimental results indicated a 9~23 % reduction in almost all flammability parameters such as heat release rate (HRR), total heat released (THR), maximum average rate of heat emission (MARHE), total smoke released (TSR), total smoke production (TSP), and mass loss (ML) during combustion. Furthermore, the combination of 6 wt.% ESP and 3 wt.% HNT reduced the stiffness of OAP to an insignificant amount by maximum 3%. Moreover, the char residue analysis revealed the distinct differences in the formation of char between AF/PP and AF/PP/ESP/HNT composites. Afterward, dilatometry test was carried out to examine the coefficient of thermal expansion (CTE) of OAP and OAPEH samples. The obtained results showed that the CTE of OAPEH composite was about 18% less than that of OAP. Finally, a theoretical model was used based on first-order shear deformation theory (FSDT) to predict the critical bucking temperatures of the OAP and OAPEH composite plates. It was shown that in the absence of mechanical load, the critical buckling temperatures of OAPEH composite plates were higher than those of OAP composites, such that the difference between the buckling temperatures increased with the increase of thickness. On the contrary, the positive effect of CTE reduction on the buckling temperature decreased by raising the axial compressive mechanical load on the composite plates which can be assigned to the reduction of stiffness after the incorporation of ESP. The results of present study generally stated that a suitable combination of AF, PP, ESP, and HNT can result in a relatively optimal and environmentally friendly composite with proper flame and thermal buckling resistance with no significant decline in the stiffness.

서해안 태안 어은리 갯벌의 연속관측 메탄(CH4) 플럭스 특성 평가 (Evaluation of CH4 Flux for Continuous Observation from Intertidal Flat Sediments in the Eoeun-ri, Taean-gun on the Mid-western Coast of Korea)

  • 이준호;노경찬;우한준;강정원;정갑식;장석
    • 자원환경지질
    • /
    • 제48권2호
    • /
    • pp.147-160
    • /
    • 2015
  • 2014년 8월 31일~9월 1일 충남 태안 어은리 갯벌 퇴적물의 동일한 실험 장소에서 닫힌 챔버를 이용하여 챔버내 가스들(메탄($CH_4$), 이산화탄소($CO_2$) 및 산소($O_2$))의 갯벌 표면 노출시 일조량이 있는 조석주기의 저조 시점을 기준으로 각 기체의 플럭스량을 파악하기 위해 총 6회 실험하였다. 챔버 내에서 채취된 대기 샘플 중 메탄의 농도는 6시간 이내에 지구온실가스 측정용 EG model GS-23 가스크로마토그래피로 분석하였으며 그 외 가스종은 Multi Gas Monitor를 이용하여 실시간 측정하였다. 각 가스 종들의 배출원(source (+)) 또는 흡수원(sink (-))의 플럭스 계산값은 단순 선형 회귀분석을 이용하여 시간에 따른 각 기체의 농도변화인 1차 함수 기울기 값을 수식에 대입하여 계산하였다. 또한 주변 환경 특성을 참고하기 위해 퇴적물 함수율, 온도, 총유기탄소, 챔버내 온도 및 퇴적물 퇴적상도 측정하였다. 첫째날, 총 3회 플럭스 측정이 진행되는 5시간 20분 동안 이산화탄소는 $-137.00{\sim}-81.73mg/m^2/hr$ 흡수원, 산소는 $-0.03{\sim}0.00mg/m^2/hr$ 흡수원 그리고 둘째날, 이산화탄소는 -20.43~-2.11 mg/m2/hr 흡수원, 산소는 $-0.18{\sim}-0.14mg/m^2/hr$ 흡수원으로 모두 동일하였다. 메탄의 경우 양일간 조석주기의 저조 시점이 되기 전에는 첫째날 $-0.02mg/m^2/hr$ 흡수원(SPSS 통계분석을 이용한 Pearson 상관계수는 뚜렷한 음의 선형관계인-0.555(n=5, p=0.332)) 및 둘째날 $-0.15mg/m^2/hr$ 흡수원(상관계수는 강한 음의 선형관계인 -0.915(n=5, p=0.030))으로 작용하였다. 그리고 저조시점 이후로 메탄은 첫째날 최소 $+0.00mg/m^2/hr$ 배출원(상관계수는 거의 무시될 수 있는 선형관계인 +0.713(n=5, p=0.176)) 및 둘째날 최대 $+0.03mg/m^2/hr$ 배출원(상관계수는 약한 양의 선형관계인 +0.194(n=5, p=0.754))이 된다는 플럭스 양상은 양일간 모두 같았다. 그러나 $CH_4$ 플럭스 값은 일자 및 시간별로 모두 다르게 분석되었다. 이러한 결과는 같은 시간, 동일지역 퇴적물 일지라도 $CH_4$ 플럭스 변화율은 갯벌 근처 해수의 표층 조석주기 특성 이해를 통한 가스 방출 상관관계 및 물리화학적 퇴적물 환경과 같은 주변 변수에 따라 영향을 받음 수 있음을 보여준다.

저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰 (Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration)

  • 김일수;김호신;류형기;강영직;박수영;김승찬;이귀원
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.32-36
    • /
    • 2016
  • 핵의학검사에서 $^{131}I$은 갑상선암 및 질환의 진단, 치료등 핵의학 검사에서 많이 사용되고 있다. $^{131}I$${\gamma}$선과 ${\beta}^-$선을 방출하여 검사와 치료를 할 수 있고, 높은 집적율과 신장을 통한 빠른 배설이 용이 하지만, $^{131}I$(364 keV)은 $^{99m}Tc$(140 keV)보다 고에너지이기 때문에 작업을 수행 시 조작 및 투여 과정에서 $^{99m}Tc$보다 술자의 피폭을 줄이기 위해 외부피폭 방어의 3요소인 거리, 시간, 차폐 중에 차폐에 주안점을 두어 $^{131}I$ 조작 시 차 폐체 착용 전과 후의 피폭선량의 차이를 비교하고자 한다. Apron(보통 Pb 0.5 mm) 착용 시 $^{99m}Tc$은 90%이상이 차폐가 되지만, $^{131}I$은 고에너지이기 때문에 차폐효과가 비교적 낮고, 고용량의 경우 산란선(2차) 및 제동방사선의 영향으로 오히려 더 피폭을 받을 수 있다. 하지만 저용량(74 MBq) 고에너지의 경우 이에 대한 특별한 보고나 Guide Line이 마련되어 있지 않아, $^{131}I$ 조작 시 Apron 착용 유무에 따른 술자의 피폭선량을 정량적으로 분석하고자 한다. 본원 핵의학과에서 2014년 6월부터 2014년 12월까지 7개월 동안 갑상선암 치료 및 진단을 위한 저용량$^{131}I$을 투여하기 위해 방문한 갑상선암 환자를 대상으로 준비과정부터 투여 시까지 연구기간 동안 갑상선, 가슴, 고환 3곳에 Apron 안쪽과 바깥쪽 각각 1개씩 총 6개의 TLD를 부착한 뒤 $^{131}I$검사 과정부터 투여 시 까지의 방사선 피폭선량을 측정하였다. 총 작업시간은 설명시간 3분, 분배시간 1분, 투여시간 1분으로 각각 1인당 5분이내로 설정하였다. TLD 위치설정은 일반적으로 피폭선량을 측정하는 가슴과 방사선 감수성이 높은 갑상선 및 고환으로 설정하였다. 준비과정은 $^{131}I$$2m{\ell}$ 주사기를 이용해 74MBq을 분배한 뒤 생리식염수와 희석해 $2m{\ell}$의 용량을 만들어 분배한다. $^{131}I$을 분배 후 환자에게 투여 시 컵에 물을 $100m{\ell}$ 담고 분배한 $^{131}I$을 희석하여 환자 1 m 정도 거리를 두고, 경구투여 한다. 그리고 경구투여 한 $2m{\ell}$ 주사기와 컵을 폐기하는 과정을 Apron과 TLD를 착용한 상태에서 시행하였다. Apron과 TLD는 방사선 피폭이 미치지 않는 보관실에 따로 보관하였고, 서울방사선 서비스에 의뢰하여 피폭선량을 측정하였다. 연구기간 동안 저용량 $^{131}I$ 검사 시 갑상선, 가슴, 고환 부위에 Apron 안과 밖d[착용한 TLD의 매월 누적선량을 인원수로 나눈 결과를 가지고, SPSS Version. 12.0K를 이용해 Wilcoxon Signed Rank Test를 사용하여 통계를 시행하였다. 그 결과 갑상선(p = 0.345), 가슴(p = 0.686), 고환(p = 0.715)은 모두 p > 0.05으로 유의한 차이가 없음을 알 수 있었다. 그리고 연구기간 동안의 총 누적선량의 변화를 백분율로 환산하였을 때, 갑상선 -23.5%, 가슴 -8.3%, 고환 19.0%로 나타났다. Wilcoxon Signed Rank Test를 사용한 결과 통계적으로 유의한 차이가 없는 것으로 나타났다(p > 0.05). 또한 7개월간의 누적선량으로 차폐율을 계산 했을 때 에는 Apron 안쪽과 바깥쪽의 피폭선량의 변화가 불규칙적으로 나타나는 결과를 보였다. 이 결과는 백분율로 표현 시 변화폭이 커보이지만, 누적 피폭선량이 소수점 이하이므로 큰 변화라고 보기 어렵다. 그러므로 고에너지 저용량 $^{131}I$ 투여 시 Apron을 착용유무와 상관없이 일정한 거리를 두고 최대한 빠른 시간 내에 투여를 종료하는 것이 피폭선량을 줄이는 데 도움이 될 것이다. 본 연구는 $^{131}I$ 투여시간을 1인당 각 5분 이내로 투여 할 수 있도록 제한하고, 거리를 1 m로 일정하게 하여 작업 할 수 있도록 하였으나 통계 시 N수가 적어서 비모수적인 방법으로 통계를 시행함으로써 정확한 결과를 얻기에 부족한 부분이 있었다. 또한 저용량 $^{131}I$ 투여 시 각 1인당 피폭선량을 직독식 선량으로 측정하지 못하고, TLD를 이용한 누적선량으로 측정한 결과 값이므로 전자선량계 및 포켓선량계를 이용한 측정이 이루어진다면 더 효과적인 결과를 얻을 수 있을 것으로 사료된다.

  • PDF

ICP-AES를 이용한 토양 시료 중 비소 분석 방법 개선 (Improvement of analytical methods for arsenic in soil using ICP-AES)

  • 이홍길;김지인;김록영;고형욱;김태승;윤정기
    • 분석과학
    • /
    • 제28권6호
    • /
    • pp.409-416
    • /
    • 2015
  • ICP-AES는 넓은 검량범위 및 다성분 동시분석이라는 장점이 있어 많은 연구소에서 사용되지만 비소의 경우 토양 중에 존재하는 성분들이 함께 방출되어 스펙트럼 간섭이 일어나 농도가 과대/과소평가 될 수 있다. 본 연구에서는 표준 인증 물질(CRMs)과 현장 토양시료를 국내 토양오염 공정시험기준에 의거하여 HG-AAS 및 ICP-AES로 분석하여 발생하는 문제점을 살펴보았다. HG-AAS 분석결과는 모든 CRM에 대해 90.8~106.3%의 정확도를 보인 반면, ICP-AES는 비소의 농도가 낮으며 철 및 알루미늄의 농도가 높은 CRM에서 정확도를 만족하지 못했으며 CRM030의 경우 193.696 nm에서 정확도가 39% 미만으로 나타났다. 비소의 측정파장에서 발생하는 간섭영향을 살펴본 결과, 193.696 nm 부근에서 50 mg/L 철 및 알루미늄에 의해 각각 유의한 수준의 partial overlap, sloping background가 발생하였으나 188.980 nm에서는 간섭이 미미하거나 없는 것으로 확인되었다. 현장시료를 ICP-AES로 측정한 결과 각각 188.980 nm, 193.696 nm에서 저농도/고농도 비소가 HG-AAS로 측정한 결과와 가장 유사한 것으로 나타났다. 따라서, ICP-AES를 분석장비로 사용할 경우 시료 매질, 분석 조건 등에 따라 간섭영향이 달라질 수 있으므로 분석자는 비소의 농도에 따라 적절한 파장을 선택하는 것이 중요하다. 또한 ICP-AES 분석에서 간섭 영향이 확인되는 경우에는 HG-AAS와 교차분석 등의 방법을 고려해야 한다. ICP-AES 분석의 대안으로 검토한 HG-ICP-AES는 HG로 간섭을 줄여 검출한계가 향상되었으며 HG-AAS에 비해 넓은 검량범위를 나타내 적절한 분석방법으로 평가되었다.

저온 성장 AlN 층이 삽입된 Al0.55Ga0.45N/AlN/GaN 이종접합 구조의 구조적 특성 및 이차원 전자가스의 광학적 특성 (Structural properties and optical studies of two-dimensional electron gas in Al0.55Ga0.45/GaN heterostructures with low-temperature AlN interlayer)

  • 곽호상;이규승;김희진;윤의준;조용훈
    • 한국진공학회지
    • /
    • 제17권1호
    • /
    • pp.34-39
    • /
    • 2008
  • 저온에서 성장된 AlN (LT-AlN)층이 삽입된 $Al_xGa_{1-x}N/LT$-AlN/GaN 이종접합 구조를 금속유기 화학기상 증착법 (metal-organic chemical vapor deposition)을 사용하여 사파이어 기판 위에 제작하였다. Rutherford backscattering spectroscopy 실험을 통하여 $Al_xGa_{1-x}N$층의 Al의 조성비 x가 55% 임을 확인하였고, X-선 역격자 공간 mapping을 통하여 층간 변형력을 조사하였다. LT-AlN층의 삽입 여하에 따른 $Al_{0.55}Ga_{0.45}N$ 층의 깨짐 현상을 광학현미경과 주사전자현미경을 통하여 조사하였는데, LT-AlN 층이 삽입된 시료의 경우에 깨짐 현상이 현저히 줄어든 $Al_{0.55}Ga_{0.45}N$ 층을 얻을 수 있었다. 뿐만 아니라 LT-AlN 층이 삽입된 $Al_{0.55}Ga_{0.45}N$/LT-AlN/GaN 이종접합 구조에 대하여 이차원 전자가스 (two-dimensional electron gas, 2DEG) 관련된 photoluminescence (PL) 신호를 관찰하였다. 이 시료에 대하여 온도 변화에 따른 PL 실험을 수행하여 100 K 근방까지 2DEG 관련된 PL 신호를 관찰하였다. 여기광 세기에 따른 PL 실험을 통하여 ~3.411 eV에서 나타난 2DEG PL 신호와 함께 ${\sim}3.437eV$에서도 PL 신호가 관측되었는데, 이는 AlGaN/LT-AlN/GaN 계면에 형성된 2DEG 버금띠와 Fermi 에너지 준위에서의 재결합 특성으로 각각 해석되었다.