• Title/Summary/Keyword: Low dose rate

Search Result 579, Processing Time 0.028 seconds

RADIATION SHIELDING EVALUATION OF IP-2 PACKAGES FOR LOW- AND INTERMEDIATE-LEVEL RADIOACTIVE WASTE

  • Kim, Min-Chul;Choi, Jong-Rak;Chung, Sung-Hwan;Ko, Jae-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.40 no.6
    • /
    • pp.511-516
    • /
    • 2008
  • Korea Hydro & Nuclear Power Co., Ltd. (KHNP) developed new IP-2 packages to transport low- and intermediate-level radioactive waste (LILW) steel drums from nuclear power plants to a disposal facility in accordance with IAEA and Korean transport regulations of radioactive material. Radiation shielding evaluation of the packages was carried out to demonstrate compliance with the regulatory requirements for IP-2 packages of radioactive material. Dose rate limits of LILW drums contained in the packages were determined.

Determination of optimum gamma ray range for radiation mutagenesis and hormesis in quinoa (Chenopodium quinoa Willd.)

  • Park, Chan Young;Song, Seon Hwa;Sin, Jong Mu;Lee, Hyeon Young;Kim, Jin Baek;Shim, Sang In
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.240-240
    • /
    • 2017
  • Quinoa (Chenopodium quinoa Willd.) is one of the ancient crops cultivated in the Andes region at an altitude of 3,500-4000m in Chile and Bolivia from 5000 BC. It contains a large amount of protein, minerals and vitamins in comparison with other crops. The cultivation area has been increasing worldwide because of its excellent resistance to various abiotic stress such as salinity, drought and low temperature. ${\gamma}$-Ray radiation of high dose is often used as a tool to induce mutations in plant breeding, but it has a deleterious effect on organisms. However, the radiation may have a positive stimulatory effect of 'hormesis' in the low dose range. This experiment was carried out to investigate the optimum dose range for creating the quinoa genetic resources and to investigate the hormesis effect at low dose on the quinoa. This experiment was performed for 120 days from November, 2016 to February, 2017 in the greenhouse of Gyeongsang National University. ${\gamma}$-Ray radiation was irradiated to seeds at 0 Gy, 50 Gy, 100 Gy, 200 Gy, 300 Gy, 400 Gy, 600 Gy, 800 Gy and 1000 Gy for 8 hours. (50 Gy) using the low level radiation facility ($Co^{60}$) of Cooperative Research Institute of Radiation Research Institute, KAERI. Fifty seeds were placed on each petri dish lined with wet filter paper and germination rate was measured at a time interval of 2 hours for 40 hrs. The length of the root length was measured one week after germination. Each treatment was carried out in 3 replicates. The growth of seedlings were investigated for 10 days after transplanting of 30 day-old seedlings. The plant height, NDVI, SPAD, Fv/Fm, and panicle weight were measured. The germination rate was highest at 50Gy and 0Gy and the rate of seeds treated with 400Gy or higher rate decreased to 25% of the seeds treated with 50Gy. The emergence rate of seedling in pot experiment was higher at the dose of 200 Gy, 300 Gy and 400 Gy than at 0 and 50Gy. However, the rate was lower at strong radiation higher than 600Gy at which $1^{st}$ leaf was not expanded fully and dead due to extreme overgrowth at 44 days after treatment (DAT). The highest value of panicle weight was observed at 50Gy (6.15g) and 100Gy (5.57g). On the other hand, the weight at high irradiated dose of 300Gy and 400Gy was decreased by about 55% compared to low dose (50 Gy). NDVI measurement also showed the highest value at 50 Gy as the growth progressed. SPAD was the highest at 400 Gy and showed positive correlation with irradiation dose except 0 Gy. Fv/Fm was high at 50 Gy up to 30 DAT and no difference between treatments was observed except for 400 Gy from 44 DAT. The plant height was the highest in 50Gy during the growing period and was higher in the order of 50Dy, 100Gy, 0Gy, 200Gy, 300Gy and 400Gy in 88 DAT. In this experiment, the optimal radiation dose for hormesis was 50Gy and 100Gy, and the optimal radiation dose for mutagenesis seems to be 400 Gy.

  • PDF

Effect of Low Dose γ Radiation on the Dormancy Breaking and Growth of in vitro Microtubers of Potato (Solanum tuberosum L.) Stored at Low Temperature (저선량 방사선이 저온 저장한 감자 기내 소괴경의 휴면타파와 생육에 미치는 효과)

  • Kim, Jae-Sung;Kim, Dong-Hee;Back, Myung-Hwa;Jeon, Jae-Heung;Lee, Young-Bok
    • Horticultural Science & Technology
    • /
    • v.19 no.4
    • /
    • pp.515-520
    • /
    • 2001
  • To observe the stimulating effect of low dose ${\gamma}$ radiation on the dormancy breaking and growth, microtubers of two potato cultivars (Solanum tuberosum L. cv. Dejima and cv. Superior) were irradiated at the dose of 0.5-30 Gy. Though it varied with cultivars and storage duration, sprouting rate, plant growth and tuber yield were promoted by 2-8 Gy irradiation in microtuber of 'Dejima' stored at low temperature. On the other hand, in microtuber of 'Superior', sprouting rate was promoted by 2 and 4 Gy irradiation, and the growth and tuber yield by 4 Gy irradiation. These results suggest that low dose of ${\gamma}$ radiation could have stimulating effects on the dormancy breaking of microtuber and potato growth.

  • PDF

Effects of low dose gamma irradiation on the germination and physiological activity of old red pepper ( Capsicum annuum L.) seed (묵은 고추종자의 발아와 생리활성에 미치는 저선량 방사선조사 효과)

  • Kim, Jae-Sung;Back, Myung-Hwa;Lee, Hae-Youn;Lee, Young-Keun
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.409-415
    • /
    • 2001
  • To observe the stimulating effects of low dose gamma radiation on the germination and physiological activity of germinating seeds of old red pepper (Capsicum annuum L. cv Jokwang and cv. Hongkwang), seeds were irradiated at the dose of $2{\sim}50 Gy$. The germination rate of irradiation group was higher than that of the control. Especially it was highest at the early stage of induction. The germination rate at 7 days after sowing in Jokwang and Hongkwang cultivar was high as 74% and 11% at 4 Gy and 8 Gy irradiation group, respectively. The seedling height of Jokwang cultivar was noticeably high at 4 Gy irradiation group and that of Hongkwang cultivar at 8 Gy irradiation group. The protein contents of seedlings from seeds irradiated with low dose gamma radiation of Jokwang cultivar increased at the late stage of induction and that of Hongkwang cultivar at the early stage of induction. Catalase and peroxidase activities of seedlings from seeds irradiated with low dose gamma radiation of Jokwang cultivar increased at 4 Gy irradiation group and that of Hongkwang cultivar at 8 Gy irradiation group.

  • PDF

Nutritional strategy of early amino acid administration in very low birth weight infants

  • Lee, Byong Sop
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.3
    • /
    • pp.77-83
    • /
    • 2015
  • Relative to a fetus of the same gestational age, very low birth weight (VLBW) infants are more likely to be underfed and to undergo growth restriction during their early hospital stay. The current trend towards "early and aggressive" nutritional strategies in VLBW infants aims to overcome the early nutritional deficiency and thereby boost postnatal catch-up growth, simultaneously improving long-term neurodevelopmental outcomes. Although the minimum starting amino acid (AA) dose to prevent negative nitrogen balance is well established, the upper limit and the rate of increase of early AA doses are controversial. Most randomized controlled trials show that early and high-dose (target, 3.5 to 4.9 g/kg/day) AA regimens, with or without high nonprotein calories, do not improve long-term growth and neurodevelopment. High-dose AA supplementation may lead to early metabolic disturbances and excessive or disproportionate plasma AA levels, particularly in infants of very low gestational age. Further large studies are needed to clarify the optimal strategy for early administration of parenteral AA doses in VLBW infants.

Analysis of Trends in Dose through Evaluation of Spatial Dose Rate and Surface Contamination in Radiation-Controlled Area and Personal Exposed Dose of Radiation Worker at the Korea Institute of Radiological and Medical Sciences (KIRAMS)

  • Lee, Bu Hyung;Kim, Sung Ho;Kwon, Soo Il;Kim, Jae Seok;Kim, Gi-sub;Park, Min Seok;Park, Seungwoo;Jung, Haijo
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.146-155
    • /
    • 2016
  • As the probability of exposure to radiation increases due to an increase in the use of radioisotopes and radiation generators, the importance of a radiation safety management field is being highlighted. We intend to help radiation workers with exposure management by identifying the degree of radiation exposure and contamination to determine an efficient method of radiation safety management. The personal exposure doses of the radiation workers at the Korea Institute of Radiological & Medical Sciences measured every quarter during a five-year period from Jan. 1, 2011 till Dec. 31, 2015 were analyzed using a TLD (thermoluminescence dosimeter). The spatial dose rates of radiation-controlled areas were measured using a portable radioscope, and the level of surface contamination was measured at weekly intervals using a piece of smear paper and a low background alpha/beta counter. Though the averages of the depth doses and the surface doses in 2012 increased from those in 2011 by about 14%, the averages were shown to have decreased every year after that. The exposure dose of 27 mSv in 2012 increased from that in 2011 in radiopharmaceutical laboratories and, in the case of the spatial dose rate, the rate of decrease in 2012 was shown to be similar to the annual trend of the whole institute. In the case of the surface contamination level, as the remaining radiation-controlled area with the exception of the I-131 treatment ward showed a low value less than $1.0kBq/m^2$, the annual trend of the I-131 treatment ward was shown to be similar to that of the entire institute. In conclusion, continuous attention should be paid to dose monitoring of the radiation-controlled areas where unsealed sources are handled and the workers therein.

Optimum Dose Combination of External Radiation and High Dose Rate ICR in FIGO IB Uterine Cervical Cancer (병기 IB 자궁경부암의 방사선치료에서 외부방사선치료와 고선량율 강내치료의 최적선량 배합)

  • Lee Sang Wook;Suh Chang Ok;Chung Eun Ji;Kim Woo Cheol;Chang Sei Kyung;Keum Ki Chang;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.201-209
    • /
    • 1996
  • Purpose : To assess the efficacy of high dose rate - intracavitary radio-therapy (HDR-ICR) in the radiotherapy of FIGO stage IB squamous cell carcinoma of uterine cervix and to determine the optimum dose combination scheme of external radiotherapy and ICR to achieve acceptable local control without severe complication. Materials and Methods : One hundred and sixty two patients with FIGO stage Ib squamous cell carcinoma of uterine cervix who received definitive radiotherapy between May 1979 and December 1990 were retrospectively analyzed. All the patients received external radiotherapy combined with HDR-ICR. External dose of 40-46 Gy in 4.5-5 weeks was given to whole pelvis(median 45 Gy) and ICR dose of 30-39 Gy in 10-13 times was given to the point A. Midline shielding was done after 20-45 Gy of external radiotherapy(median 40 Gy) Summation of external dose Plus ICR dose to the point A range were 64.20-95.00 Gy. and mean was 83.94 Gy. We analyzed the local control rate, survival rate, and late complication rate. Rusults : Initial complete response rate was $99.4\%$ for all patients. Overall 5-year survival rate was $91.1\%$ and 5-year disease free survival rate was $90.9\%$. Local failure rate was $4.9\%$ and distant failure rate was $4.3\%$. Tumor size was the only significant prognostic factor. When tumor size greater than 3cm, 5-rear survival rate was $92.6\%$ and less than 3cm, that was $79.6\%$. Late complication rate was $23.5\%$ with $18.5\%$ of rectal complication and $4.9\%$ of bladder complication. Mean rectal dose summation of external midline dose plus ICR rectal point dose was lower in the patients without rectal complication(74.88 Gr) than those with rectal complication (78.87 Gy). Complication rate was increased with low rate of improvement of survival rate when summation of external midline dose plus point A or point R dose by ICR was greater than 70-75 Gy. Conclusion : The definitive radiation therapy using high dose rate ICR in FIGO stage IB uterine cervical cancer is effective treatment modality with good local control and survival rate without severe complication.

  • PDF

Use of Cylindrical Chambers as Substitutes for Parallel-Plate Chambers in Low-Energy Electron Dosimetry

  • Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Cho, Jin Dong;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.29 no.1
    • /
    • pp.16-22
    • /
    • 2018
  • Current dosimetry protocols recommend the use of parallel-plate chambers in electron dosimetry because the electron fluence perturbation can be effectively minimized. However, substitutable methods to calibrate and measure the electron output and energy with the widely used cylindrical chamber should be developed in case a parallel-plate chamber is unavailable. In this study, we measured the correction factors and absolute dose-to-water of electrons with energies of 4, 6, 9, 12, 16, and 20 MeV using Farmer-type and Roos chambers by varying the dose rates according to the AAPM TG-51 protocol. The ion recombination factor and absolute dose were found to be varied across the chamber types, energy, and dose rate, and these phenomena were remarkable at a low energy (4 MeV), which was in good agreement with literature. While the ion recombination factor showed a difference across chamber types of less than 0.4%, the absolute dose differences between them were largest at 4 MeV at approximately 1.5%. We therefore found that the absolute dose with respect to the dose rate was strongly influenced by ion-collection efficiency. Although more rigorous validation with other types of chambers and protocols should be performed, the outcome of the study shows the feasibility of replacing the parallel-plate chamber with the cylindrical chamber in electron dosimetry.