• 제목/요약/키워드: Low Power Data Transmission

검색결과 337건 처리시간 0.024초

Pre-processing of load data of agricultural tractors during major field operations

  • Ryu, Myong-Jin;Kabir, Md. Shaha Nur;Choo, Youn-Kug;Chung, Sun-Ok;Kim, Yong-Joo;Ha, Jong-Kyou;Lee, Kyeong-Hwan
    • 농업과학연구
    • /
    • 제42권1호
    • /
    • pp.53-61
    • /
    • 2015
  • Development of highly efficient and energy-saving tractors has been one of the issues in agricultural machinery. For design of such tractors, measurement and analysis of load on major power transmission parts of the tractors are the most important pre-requisite tasks. Objective of this study was to perform pre-processing procedures before effective analysis of load data of agricultural tractors (30, 75, and 82 kW) during major field operations such as plow tillage, rotary tillage, baling, bale wrapping, and to select the suitable pre-processing method for the analysis. A load measurement systems, equipped in the tractors, were consisted of strain-gauge, encoder, hydraulic pressure, and radar speed sensors to measure torque and rotational speed levels of transmission input shaft, PTO shaft, and driving axle shafts, pressure of the hydraulic inlet line, and travel speed, respectively. The entire sensor data were collected at a 200-Hz rate. Plow tillage, rotary tillage, baling, wrapping, and loader operations were selected as major field operations of agricultural tractors. Same or different farm works and driving levels were set differently for each of the load measuring experiment. Before load data analysis, pre-processing procedures such as outlier removal, low-pass filtering, and data division were performed. Data beyond the scope of the measuring range of the sensors and the operating range of the power transmission parts were removed. Considering engine and PTO rotational speeds, frequency components greater than 90, 60, and 60 Hz cut off frequencies were low-pass filtered for plow tillage, rotary tillage, and baler operations, respectively. Measured load data were divided into five parts: driving, working, implement up, implement down, and turning. Results of the study would provide useful information for load characteristics of tractors on major field operations.

Development of an Equipment for Monitoring Current and Voltage on a Power Transmission Line

  • K. Kuwanami;E.Jishiuama;T Matsuda;I.Oota;H.Kuribayashi;N. Ueda;Ha, S.yata
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.233-236
    • /
    • 2000
  • A portable equipment that measures a current and voltage waveform of power transmission lines is pro-posed. In the equipment, the current and voltage, respectively, are detected by a loop coil and a capacitor clamped around the power lines. The detected data is transmitted by an FM wave to the receiver on the ground station. Since the receiver is isolated from the power lines, we do not require high potential insulators for the measurement of current and voltage. The proposed equipment is therefore, small-sized, light, and low in the cost of production. Experimental results presented here show that the equipment can monitor the current flowing in single wire over a ground plane and the potential of the wire.

  • PDF

저 전압 트리거형 ESD 보호소자를 탑재한 LVDS Driver 설계 (The Design of LVDS Driver with ESD protection device of low voltage triggering characteristics)

  • 육승범;김귀동;권종기;구용서
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.805-808
    • /
    • 2005
  • In this study, the design of advanced LVDS(Low Voltage Differential Signaling) I/O interface circuit with new structural low triggering ESD(Electro-Static Discharge) protection circuit was investigated. Due to the differential transmission technique and low power consumption at same time. maximum transmission data ratio of designed LVDS transmitter was simulated to 5Gbps, Also, the LIGCSCR(Latch-up Immune Gate Coupled SCR)was designed. It consists of PLVTSCR (P-type Low Voltage Trigger SCR), control NMOS and RC network. The triggering voltage was simulated to 3.6V. And the latch-up characteristics were improved. Finally, we performed the layout high speed I/O interlace circuit with the low triggered ESD protection device in one-chip.

  • PDF

Ultra low-power active wireless sensor for structural health monitoring

  • Zhou, Dao;Ha, Dong Sam;Inman, Daniel J.
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.675-687
    • /
    • 2010
  • Structural Health Monitoring (SHM) is the science and technology of monitoring and assessing the condition of aerospace, civil and mechanical infrastructures using a sensing system integrated into the structure. Impedance-based SHM measures impedance of a structure using a PZT (Lead Zirconate Titanate) patch. This paper presents a low-power wireless autonomous and active SHM node called Autonomous SHM Sensor 2 (ASN-2), which is based on the impedance method. In this study, we incorporated three methods to save power. First, entire data processing is performed on-board, which minimizes radio transmission time. Considering that the radio of a wireless sensor node consumes the highest power among all modules, reduction of the transmission time saves substantial power. Second, a rectangular pulse train is used to excite a PZT patch instead of a sinusoidal wave. This eliminates a digital-to-analog converter and reduces the memory space. Third, ASN-2 senses the phase of the response signal instead of the magnitude. Sensing the phase of the signal eliminates an analog-to-digital converter and Fast Fourier Transform operation, which not only saves power, but also enables us to use a low-end low-power processor. Our SHM sensor node ASN-2 is implemented using a TI MSP430 microcontroller evaluation board. A cluster of ASN-2 nodes forms a wireless network. Each node wakes up at a predetermined interval, such as once in four hours, performs an SHM operation, reports the result to the central node wirelessly, and returns to sleep. The power consumption of our ASN-2 is 0.15 mW during the inactive mode and 18 mW during the active mode. Each SHM operation takes about 13 seconds to consume 236 mJ. When our ASN-2 operates once in every four hours, it is estimated to run for about 2.5 years with two AAA-size batteries ignoring the internal battery leakage.

새로운 구조의 ESD 보호소자를 내장한 고속-저전압 LVDS Driver 설계 (Design of high speed-low voltage LVDS driver circuit with the novel ESD protection device)

  • 이재현;김귀동;권종기;구용서
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.731-734
    • /
    • 2005
  • In this study, the design of advanced LVDS(Low Voltage Differential Signaling) I/O interface circuit with new structural low triggering ESD (Electro-Static Discharge) protection circuit was investigated. Due to the differential transmission technique and low power consumption at the same time. Maximum transmission data ratio of designed LVDS transmitter was simulated to 5Gbps. And Zener Triggered SCR devices to protect the ESD phenomenon were designed. This structure reduces the trigger voltage by making the zener junction between the lateral PNP and base of lateral NPN in SCR structure. The triggering voltage was simulated to 5.8V. Finally, we performed the layout high speed I/O interface circuit with the low triggered ESD protection device in one-chip.

  • PDF

웨이블렛을 이용한 초광대역 데이터 전송 시스템 (A System of Ultra Wide Band Data Transmission Using Wavelet)

  • 노진수;박종태;이강현
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 I
    • /
    • pp.446-449
    • /
    • 2003
  • In recent years, the research of an efficient transmission method is going to meet a demand for high speed and large capacity radio communication. These systems make use of ultra-short duration pulses which yield UWB(Ultra Wide Band) signals characterized by low power spectral densities. The wavelet synthesis wave is able to set up the scale freely. So it is possible to use as the transmission wave of UWB by compressing time. In this paper, we present a general analytical expression for the average BER(Bit Error Rate) performance of UWB data transmission using wavelet system as a function of the cross-correlation between the users' signatures in an additive white Gaussian noise(AWGN) channel.

  • PDF

사물 네트워크에서 LoRa 기반 네트워크 프로토콜 설계 및 적용 (Design and Application of LoRa-based Network Protocol in IoT Networks)

  • 이성근
    • 한국전자통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1089-1096
    • /
    • 2019
  • 최근 저성능 컴퓨팅을 통해 적은 양의 정보를 사용하는 소규모 사물 인터넷 서비스들이 확산되고 있다. 이를 위해 통신 반경이 넓고 전력 소모가 상대적으로 낮으며, 가격이 저렴한 저전력 장거리 통신 기술이 필요하다. 본 논문은 LoRa 통신 방식을 기반으로 넓은 지역에 분포되어 소량의 센싱 데이터를 전달하는 소물 인터넷 환경에서 멀티 홉 전송을 지원하는 MAC 계층과 라우팅 프로토콜을 제안한다. 단말 노드는 이동 가능하며, 통신 형태는 단말 노드와 네트워크 응용 서버 간의 양방향 전송을 제공한다. 제안한 프로토콜을 적용하여 스마트 팩토리 생산 설비 모니터링 시스템을 구축하였으며, 기본적인 모니터링 기능은 정상적으로 수행됨을 확인하였다.

ZigBee 응용을 위한 웨이블릿변환 기반 오디오 데이터 전송 (Audio Data Transmission Based on The Wavelet Transform for ZigBee Applications)

  • 진진흥;최은창;허재두;강석근
    • 대한임베디드공학회논문지
    • /
    • 제2권1호
    • /
    • pp.31-42
    • /
    • 2007
  • A transform coding scheme for the transmission of audio data in ZigBee based wireless personal area networks (WPAN) is presented in this paper. Here, wavelet transform is exploited to encode the features of audio data included mainly in the low frequency region. As a result, it is confirmed that the presented scheme recovers the original audio signals much accurately while it transmits the binary data compressed as 37.5% of the entire data generated without coding scheme. Especially, the mean-squared error between the recovered and original audio data approaches $10^{-4}$ when the signal-to-noise power ratio is sufficiently high. Hence, the presented coding scheme which exploits the wavelet transform is possibly applied for high-quality audio data transmission services in a small-scale sensor network based on ZigBee. Such a result is considered to be applicable as a basic material to update the technical specifications and develop the applications of ZigBee in WPANs.

  • PDF

Ultra-low-power Pulse Oximeter with a 32.768 kHz Real Clock

  • Lee, Wonjun;Han, Youngsun;Kim, Chulwoo;Rieh, Jae-sung;Park, Jongsun;Park, Jae Young;Kim, Seon Wook
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제6권2호
    • /
    • pp.129-132
    • /
    • 2017
  • A conventional pulse oximeter has high power consumption; thus, its mobility is severely limited. In this paper, we discuss the drawbacks of the existing pulse oximeters and propose a new ultra-low-power pulse oximeter that supports wireless data transmission for remotely monitoring vital signs, such as peripheral capillary oxygen saturation (SpO2) and beats per minute (BPM). We could notably reduce power consumption by using a low-frequency single clock in all well-customized modules. Also, our device is publicly certified, and thus, possibly engaged in clinical trials for commercial use.

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.