• 제목/요약/키워드: Low Permeability

검색결과 876건 처리시간 0.029초

화상분석법을 이용한 하이브리드 콘크리트의 공극구조 특성 및 투수성 평가 (Estimation of Pore Structure Characteristic and Permeability of Hybrid Concrete by Image Analysis Method)

  • 장봉진;전범준;홍영호;배종오;임홍범
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.59-67
    • /
    • 2015
  • PURPOSES : In this study, an image analysis method is used to evaluate the pore structure characteristics and permeability of hybrid concrete. METHODS : The binder weight of hybrid concrete is set to $400kg/m^3$, $370kg/m^3$, and $350kg/m^3$, and for each value of binder weight, the pore structure and permeability of concrete mixture is evaluated. The permeability of hybrid concrete is evaluated using a rapid chloride penetration test(RCPT). RESULTS : The concrete pore structure characteristics of hybrid concrete reveals that as the binder weight is reduced, the entrained air is reduced and the entrapped air is increased. The permeability of the hybrid concrete for all values was measured to be below 1000 C, which indicates a "Very Low" level of permeability relative to the evaluation standard of KS F 2711. Additionally, as the binder weight is decreased, there is a significant increase in the permeability of chloride ions. CONCLUSIONS : In this study, the pore structure characteristics of hybrid concrete at different binder weights shows that as the binder weight is reduced, the entrained air is reduced and the entrapped air is increased. Consequently, chloride ion penetration resistance of the hybrid concrete is diminished. As a result, it is expected that this will reduce the concrete's durability.

다전극 산소 센서를 이용한 고분자 막의 산소 투과도 측정 장치 연구 (A Study on the Apparatus for Measuring Oxygen-Permeability of Membranes with a Multi-Electrode Oxygen Sensor)

  • 정일손;정재칠;김태진
    • 센서학회지
    • /
    • 제21권3호
    • /
    • pp.229-234
    • /
    • 2012
  • The existing permeability measurements based on pressure differential between the polymer membrane that is permeable to measure the amount of oxygen used, but these methods must be kept in a vacuum, and the measurement of the membrane with low permeability in the membrane is too time consuming. In recent years by using electrochemical method polymer membrane currents caused by the amount of oxygen is a measure of how much is used. In this study, apparatus consisting of one anode and six cathodes for multi-oxygen permeability tester used the same number of membranes produced by electrochemical oxygen permeation characteristics. In this study, one silver/silver chloride anode electrochemical method with a hexagonal sensor to put various kinds of polymer membranes with the six oxygen permeability for simultaneous measurement in real-time systems. Six cathodes (Pt), and one of the coil-shaped anode (Ag/AgCl) to form a hexagonal one of the polarographic oxygen sensor in a single measurement system by six sensors. Each sensor for making hexagonal specificity of the sensor to compensate for the conditions obtained in a pure nitrogen gas and pure oxygen gas conditions. With this study, self-developed hexagonal sensor capable of measuring sensors and oxygen permeability tester, for a multi-six different oxygen permeability characteristics of the membrane measured at the same time.

마사토의 차수성에 관한 실험적 연구 (Experimental Study on the Permeability of Decomposed Granite Soil)

  • 이형수
    • 물과 미래
    • /
    • 제7권2호
    • /
    • pp.83-91
    • /
    • 1974
  • Fill Type Dam에 있어서 일반적으로 축조재료는 경제성을 감안하여 Dam Site 부근에서 구해야하므로 Core 용재료로서는 차수성의 문제만 해결된다면 마시토도 사용가능할 것이라는 전제하에 본문에서는 마사토를 단독 또는 혼합재료로서 각종시험을 실시하여 사용가능성 여부를 검토하고 기사용범위를 정함으로써 앞으로의 사용자들에게 편의를 제공코저 한다.

  • PDF

CoZrNb막의 두께에 따른 투자율의 변화 (Permeability of CoZrNb film with thickness)

  • 허진;김영학;신광호;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.443-446
    • /
    • 2001
  • MI(Magneto-Impedance) sensor which is made by thin films has significantly high detecting sensitivity in weak magnetic field. It also has a merit to be able to build in low power system. Its structure is simple, which makes it easier to prepare a miniature. In this study, its magnetic permeability and anisotropy field(H$\sub$k/) as a function of a thickness of sputtered amorphous CoZrNb thin film with high saturation magnetostriction and excellent soft magnetic property are investigated. In order to make a uniaxial anisotropy, thin film was subjected to post annealing with a static magnetic field with 1KOe intensity at 250, 300, and 320$^{\circ}C$ for 2 hour. Anisotropy field(H$\sub$k/)of thin film is measured by using MH loop tracer. Its magnetic permeability of thin film is measured over the frequency range from 1 MHz to 750MHz. It has shown that the magnetic permeability of amorphous CoZrNb thin film is decreased due to the skin effect with increasing a thickness of CoZrNb thin film, and hence its driving frequency is lowered.

  • PDF

Evaluation of Air Void System and Permeability of Latex-Modified Concrete by Image Analysis Method

  • Jeong, Won-Kyong;Yun, Kyong-Ku;Hong, Seung-Ho
    • International Journal of Concrete Structures and Materials
    • /
    • 제19권1E호
    • /
    • pp.41-48
    • /
    • 2007
  • Addition of latex to concrete is known to increase its durability and permeability. The purpose of this study is to analyze air void systems in latex-modified concretes using a reasonable and objective method of image analysis with such experimental variables as water-cement (w/c) ratios, latex contents (0%, 15%) and cement types (ordinary portland cement (OPC), high-early strength (HES) cement and very-early strength (VES) cement). The results are analyzed by spacing factor, air volume (content) after hardening, air void distribution and structure. Additionally, air void systems and permeability of latex-modified concrete (LMC) are compared by a correlation analysis. The results are as follows. The LMC of the same w/c ratio showed better air entraining (AE) effect than OPC with AE water reducer. The VES-LMC showed that the quantity of entrained air below $100{\mu}m$ increased more than four times. For the case of HES-LMC, microscopic entrained air between the range of 50 to $500{\mu}m$ increased greater than 7 times even in the absence of anti-foamer. Although spacing factor was measured rather low, the permeability of latex-modified concrete was good. It is construed that air void system does not have a considerable effect on the property of latex-modified concrete, but latex film (membrane) has a definite influence on the durability of LMC.

DC 마그네트론 스퍼터로 증착한 flexible OLED용 IZO 박막의 기계적 특성과 투습특성에 미치는 반응성 가스 첨가의 효과 (Effects of Reactive Gas Addition on the Mechanical Property and Water Permeability of IZO Films Deposited by DC Sputtering for Application to Flexible OLED)

  • 천고은;이동엽;조영래;송풍근
    • 한국표면공학회지
    • /
    • 제40권6호
    • /
    • pp.245-249
    • /
    • 2007
  • Amorphous IZO films were deposited on PET substrate by DC magnetron sputtering without substrate heating. In order to investigate effect of reactive gas addition on film properties, 0.2-0.4% of $H_2$ or $O_2$ gas was introduced during the deposition. Deposited IZO films were evaluated with mechanical property, electrical property, and water permeability. In the case of $H_2$ gas addition, mechanical property showed clear degradation compared to $O_2$ gas. In the case of $O_2$ gas, water permeability of the IZO film was increased compared to $H_2$ gas which could be attributed to the low adhesion of the film caused by bombardment of high energy negative oxygen ion. As a result, it is confirmed that water permeability of the film could be strongly affected by adhesion of the film.

유형별 슈퍼블록이 가로활력에 미치는 영향 분석 - 서울시 강남구 역삼2동을 사례로 - (A Study on Street Vitality of Two Different Types of Superblocks - With a case of Yeoksam 2-dong, Seoul -)

  • 주상민;김지엽
    • 대한건축학회논문집:계획계
    • /
    • 제35권10호
    • /
    • pp.71-82
    • /
    • 2019
  • This study tried to prove why a low-rise residential block is more vitalized than in a superblock consisted of an apartment housing complex. To do this, two adjacent superblocks in Yeoksam 2-dong were selected as a case study among superblocks of residential area in Gangnam, Seoul. It adopted the concept of 'complexity', 'Osmosis', 'Vitality' and 'Permeability' for evaluation indexes to measure street vitality. As a result, four indexes were clearly higher in low-density residential superblocks than apartment housing complex superblocks. First, the superblocks for apartment housing complexes showed a lower 'complexity' because large-scale parcels for an apartment housing complex reduces a possibility for various land uses. Second, smaller blocks improved "osmosis" compared to larger blocks, and the larger the block, the less likely it is that buildings and streets penetrate activity. Third, as the apartment complex block became larger, the number of accesses decreased. Thus, it did not provide vitality to the streets. Fourth, high permeability was shown in the low-density superblocks, while that of the superblock consisted of apartment housing complexes was very low because the entrance of the complexes entrance is closed to the public. The results of this study demonstrated that an apartment housing complex may hamper street vitality and deteriorate the quality of urban environments.

극저탄소강판의 자성에 미치는 변형소둔 결정립도의 영향 (Effects of Strain Annealing Grain Size on the Magnetic Properties of Extra-Low Carbon Steel)

  • 안성권;정원섭;박정웅
    • 열처리공학회지
    • /
    • 제19권4호
    • /
    • pp.208-218
    • /
    • 2006
  • The effects of the grain size on the magnetic properties in extra-low carbon steel after strain annealing were investigated. Two kinds of sample were prepared. One is the annealed sheet, which was annealed at $670^{\circ}C$ and $850^{\circ}C$ for various time periods after cold rolling. The other is the strain annealed sheet, which was temper rolled by 0.4% and subsequently strain annealed at the temperature ranging between $670^{\circ}C$ and $850^{\circ}C$ for various time periods. The grains after strain annealing became more coarse than those after primary annealing. The grains were coarsened due to the strain induced grain boundary migration (SIGM). It was found that the permeability tended to be increased and coercivity tended to be decreased with the increase of grain size. The optimum magnetic properties was achieved after strain annealing at $850^{\circ}C$ for 30 minites. Under this condition, the coercivity was measured to be 0.6 and the permeability was measured up to be 13000.

압축토양의 투수성과 수도생육 및 수확량에 관한 연구 (A Study on the Effect of the Permeability to Yield Weight of Paddy Rice on the Compressed Soil)

  • 조형용
    • 한국농공학회지
    • /
    • 제15권2호
    • /
    • pp.2968-2979
    • /
    • 1973
  • The aim of this study was to bring light on the effect of permeability to yield weight of paddy rice on the compressed soil. a) The percolation volume during the growth of paddy rice reduced, while the degree of compression on soil column increased and varied by the evaporation and absorption volumn. b) The percolation volume in the natural soil column was notably low compared with that of in the artificial and had little influence to the variation of permeabilty by compression. c) The results in growth of paddy rice were best on the section of low compression and the yield weight reduced, while the degree of compression on the soil column increased. d) The relationship between the yield weight and percolation volumn, under the condition when percolation volume is 1mm/day, had little difference in the yield weight but immediately reduced under $0.5{\sim}1.0mm/day$. The consequences of investigation are not so perfect, but have done my best to get some new data for effect on additional yield by inquiring into influences of permeability to the yield weight of paddy rice on compressed paddy field. I will have a great pleasure if treatise helps investigaters or the men of affairs in this field.

  • PDF

비정질 CoFeHfO 박막 재료의 마이크로파 투자율 및 감쇠상수 분석 (Analysis of Microwave Permeability and Damping Constant in Amorphous CoFeHfO Thin Film)

  • 김동영;윤석수
    • 한국자기학회지
    • /
    • 제19권4호
    • /
    • pp.147-151
    • /
    • 2009
  • 전도성 저항특성이 우수한 비정질 CoFeHfO재료의 자화곡선 및 토오크 측정으로부터 포화자화량 및 일축이방성상수를 도출하였으며, 이들 결과를 Landau-Lifshitz-Gilbert(LLG) 이론에 적용하여 마이크로파대역의 복소투자율 특성을 분석하였다. LLG 분석 결과 CoFeHfO 박막 재료의 감쇠상수(damping factor)는 ${\alpha}$ = 0.014로 매우 작은 값을 보였다. 이는 CoFeHfO 재료 내에 존재하는 다양한 자성상(magnetic phase)들 중 감쇠상수가 현저히 작은 자성상들에 의하여 유발되었음을 자기장의 세기에 따른 FMR(ferromagnetic resonance) 신호의 선폭 분석을 통하여 알 수 있었다.