• Title/Summary/Keyword: Low Frequency Vibration

Search Result 957, Processing Time 0.033 seconds

Analysis of Fault Possibility and Vibration of Glass Insulator on High-speed Railway (고속철도용 유리애자의 진동 및 파손가능성 분석)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su;Kim, Sun-Gu;Jeon, Yong-Ju;Ryu, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2044-2045
    • /
    • 2008
  • This paper was studied fault possibility of glass insulator through the proper vibration and field vibration comparison. The proper vibration of 1 cell glass insulator have many frequency band and high amplitude showed in high frequency than low frequency. The field signal amplitude of viaduct and open route were biggest moment pantograph of high-speed rail. From the FFT analysis of viaduct and open route, in the case of positive direction, the strut tube insulator effect by vertical vibration was big, the frequency was 82.5Hz and 105Hz, respectively. However, in the case of negative direction, the vibration did not cause big effect. In comparison with the proper vibration of glass insulator, the resonance was not observed.

  • PDF

Small Energy Generator Using Multilayer Piezoelectric Devices (적층형 압전 소자를 이용한 미소 에너지발생장치)

  • Jeong, Soon-Jong;Kim, Min-Soo;Kim, In-Sung;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.261-261
    • /
    • 2007
  • Wearable and ubiquitous micro systems will be greatly growing and their related devices should be self-powered in order to avoid the replacement of finite power sources, for example, by scavenging energy from the environment. With ever reducing power requirements of both analog and digital circuits, power scavenging approaches are becoming increasingly realistic. One approach is to drive an electromechanical converter from ambient motion or vibration. Vibration-driven generators based on electromagnetic, electrostatic and piezoelectric technologies have been demonstrated. Among various generator types proposed so far, piezoelectric generator possesses considerable potential in micro system. To overcome low mechanical-to- electric energy conversion, the piezoelectric device should activate in resonance mode in response to external vibration. Normally, the external vibration excretes at low frequency ranging 0.1 to 200 Hz, whereas the resonant frequencies of the devices are fixed as constant. Therefore, keeping their resonant mode in varying external vibration can be one of important points in enhancing the conversion efficiency. We investigated the possibility of use of multi-bender type piezoelectric devices. To match the external vibration frequency with the device resonant frequency, the various devices with different resonant frequency were chosen. Under an external vibration acceleration of 0.1G at 120 Hz, the device exhibited a peak-to-peak voltage of 2.8 V and a power of 0.5 mw in resonance mode.

  • PDF

Study on Discomfort of Vertical Whole-body Shock Vibration Having Various Magnitudes, Frequencies and Damping (다양한 크기와 주파수 그리고 감쇠를 갖는 상하방향 전신 충격진동에 대한 불편함 연구)

  • Ahn, Se-Jin;Griffin, Michael J.;Yoo, Wan-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.50-57
    • /
    • 2007
  • Shocks are excited by impulsive forces and cause discomfort in vehicles. Current standards define means of evaluating shocks and predicting their discomfort, but the methods are based on research with a restricted range of shocks. This experimental study was designed to investigate the discomfort of seated subjects exposed to a wide range of vertical shocks. Shocks were produced from the responses of one degree-of-freedom models, with 16 natural frequencies (from 0.5 to 16 Hz) and four damping ratios (0.05 0.1, 0.2 and 0.4), to a hanning-windowed half-sine force inputs. Each type of shock was presented at five vibration dose values in the range $0.35\;ms^{-1.75}$ to $2.89\;ms^{-1.75}$. Fifteen subjects used magnitude estimation method to judge the discomfort of all shocks. The exponent in Stevens' power law, indicating the rate of growth in discomfort with shock magnitude, decreased with increasing fundamental frequency of the shocks. At all magnitudes, the equivalent comfort contours showed greatest sensitivity to shocks having fundamental frequencies in the range 4 to 12.5 Hz. At low magnitudes the variations in discomfort with the shock fundamental frequency were similar to the frequency weighting $W_b$ in BS 6841, but low frequency high magnitudes shocks produced greater discomfort than predicted by this weighting. At some frequencies, for the same unweighted vibration dose value, there were small but significant differences in discomfort caused by shocks having different damping ratios. The rate of increase in discomfort with increasing shock magnitude depends on the fundamental frequency of the shock. In consequence, the frequency-dependence of discomfort produced by vertical shocks depends on shock magnitude. For shocks of low and moderate discomfort, the current methods seem reasonable, but the response to higher magnitude shocks needs further investigation.

Assessment of traffic-induced low frequency sound radiated from a viaduct by field experiment

  • Kawatani, M.;Kim, C.W.;Nishitani, K.
    • Interaction and multiscale mechanics
    • /
    • v.3 no.4
    • /
    • pp.373-387
    • /
    • 2010
  • This study is intended to assess low frequency sound radiated from a viaduct under normal traffic. The bridge comprises steel box girders and wide cantilever decks on which vehicles pass. The low frequency sound and the acceleration response of the bridge under normal traffic are measured to investigate how bridge vibrations affect the low frequency sound observed near the bridge. Observations demonstrate that strong relationships exist between frequency characteristic of bridge's acceleration response and the sound pressure level of low frequency sound. A noteworthy point is that the dynamic feature of the sound pressure level is mostly affected by dynamic feature of the span locating near the observation point.

Optimal Design of Air-spring and Active Control of Vibration Isolation Table (공기스프링의 최적설계 및 방진 테이블의 능동 제어)

  • An, Chae-Hun;Kim, Ho-Sung;Yim, Kwang-Hyeok;Jin, Kyong-Bok;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.909-914
    • /
    • 2006
  • Vibration isolation tables are mostly required in precise measurement and manufacturing system. Among the vibration isolation tables, an air spring is the most favorable equipment because of low resonant frequency and high damping ratio. However, it is difficult to design the air spring with the required stiffness and damping ratio. Futhermore, whenever conventional active control methods are applied to the air spring, it may be difficult to obtain effective control performance due to high nonlinearity of air spring. In this paper, the optimal design of the air spring is performed using genetic algorithm to bring out low resonant frequency and high damping ratio. Also, active control of the vibration isolation table with 3-DOF model is proposed using the adaptive control method. Through experiments, optimal design is shown to be effective. And performance of the proposed control method is verified to be better than those of the passive control method and the conventional active control methods.

  • PDF

Numerical Study on Load Transfer Efficiency of Floating Slab Track (플로팅궤도 연결부의 하중전달효율 산정을 위한 수치해석)

  • Chung, Won-Seok;Jang, Hoon;Park, Sung-Jae;Park, Myung-Kyun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1287-1292
    • /
    • 2010
  • Recently, many railway stations are built under the railway line in urban area. The passage of railway vehicles generates mechanical vibrations of a wide range of frequency. Thus, it is required to place structural vibration isolation systems to reduce vibration and noise originating from surrounding environments. This study utilizes elastometric bearings as a vibration isolation system. The slab track system on elastometric bearings is called "low vibration track" or "floating slab track." In this low vibration track system, dowel bars or plates can be installed to minimize the discontinuity of displacement between adjacent floating slab tracks. This study is to numerically investigate the effects of dowel members on static behavior of the low vibration track. The study involves two steel dowel systems including dowel bars and dowel plates. Each dowel system is analyzed under the service load condition to assess load transfer efficiency (LTE).

  • PDF

A Case Study on Vibration of Vertical Pumps according to Changing Water Level (수위변화에 따른 수직형 펌프의 진동 발생 사례 고찰)

  • Song, Ae-Hee;Song, Jin-Dae;Kim, Hyeon-Sig;Jung, Gi-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.274-278
    • /
    • 2012
  • Vertical pumps are structurally weak in terms of vibration because of installed heavy motor on top of the pumps in form of cantilever. So high vibration on top of the pumps can occur with low vibration in the bottom. These vibration problems experienced very frequently. Majority of studies have been related to the unbalance of rotating parts or structural resonance. In this paper, we introduce an unusual case, vibration variation caused by VPF(Vane Passing Frequency) according to water level.

  • PDF