Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- 2008.07a
- /
- Pages.2044-2045
- /
- 2008
Analysis of Fault Possibility and Vibration of Glass Insulator on High-speed Railway
고속철도용 유리애자의 진동 및 파손가능성 분석
- Kim, Young-Seok (Electrical Safety Research Institute subsidiary of KESCO) ;
- Shong, Kil-Mok (Electrical Safety Research Institute subsidiary of KESCO) ;
- Jung, Jin-Su (Electrical Safety Research Institute subsidiary of KESCO) ;
- Kim, Sun-Gu (Electrical Safety Research Institute subsidiary of KESCO) ;
- Jeon, Yong-Ju (KOREA Railroad) ;
- Ryu, Young-Tae (KOREA Railroad)
- 김영석 (한국전기안전공사 전기안전연구원) ;
- 송길목 (한국전기안전공사 전기안전연구원) ;
- 정진수 (한국전기안전공사 전기안전연구원) ;
- 김선구 (한국전기안전공사 전기안전연구원) ;
- 전용주 (한국철도공사) ;
- 류영태 (한국철도공사)
- Published : 2008.07.16
Abstract
This paper was studied fault possibility of glass insulator through the proper vibration and field vibration comparison. The proper vibration of 1 cell glass insulator have many frequency band and high amplitude showed in high frequency than low frequency. The field signal amplitude of viaduct and open route were biggest moment pantograph of high-speed rail. From the FFT analysis of viaduct and open route, in the case of positive direction, the strut tube insulator effect by vertical vibration was big, the frequency was 82.5Hz and 105Hz, respectively. However, in the case of negative direction, the vibration did not cause big effect. In comparison with the proper vibration of glass insulator, the resonance was not observed.
Keywords