• 제목/요약/키워드: Loss-less snubber

검색결과 34건 처리시간 0.025초

로스레스 스너버를 사용한 고효율의 대용량 AC-DC 강압형 컨버터 (The High Power AC-DC Buck Converter of High Efficienty Using Loss-Less Snubber)

  • 문상필;서기영;이현우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.951-954
    • /
    • 1998
  • This paper proposed that a high power AC-DC buck converter topology of high efficiency using loss-less snubber operates with four chopper connecting a number of parallel circuit. To improve these, a large number of soft switching topologies included a resonant circuit have been proposed. And, some simulative resutls on computer is included to confirm the validity of the analytical results. The partial resonant circuit makes use of a inductor using step-down and a condenser of loss-less snubber. The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source of rresonant operation. The proposed conversion system is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

무손실 스너버 회로를 이용한 소프트 스위칭 강압형 고역률 컨버터 (Soft switching high power factor buck converter using loss less snubber circuit)

  • 구헌회;변영복;김성철;서기영;이현우
    • 전자공학회논문지S
    • /
    • 제34S권6호
    • /
    • pp.77-84
    • /
    • 1997
  • buck type converter doesn't appear when an input voltag eis lower than an output voltage. This is the main reason the buck converter has not been used for high power factor converters. In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn on of the switching device is a zero current switching (ZCS) and high powr factor input is obtianed. In addition, zero voltage switching (ZVS) at trun off is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontinous conduction mode operation. High power factro, efficiency, soft switching operation of proposed converter is veified by simulation using Pspice and experimental results.

  • PDF

무손실 스너버 커패시터에 의한 고효율의 DC-DC 컨버터 (DC-DC Converter of High Efficiency by using Loss-less Snubber Capacitor)

  • 곽동걸;이봉섭;김춘삼;심재선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1049-1050
    • /
    • 2006
  • This paper is proposed to a novel DC-DC converter operated high efficiency for loss-less snubber capacitor. The general converters of high efficiency is made that the power loss of the used switching devices is minimized. To achieve the soft switching operation of the used control switches, the proposed converter is constructed by using a loss-less snubber capacitor. The proposed converter achieves the soft-switching for all switching devices without increasing their voltage and current stresses. The result is that the switching loss is very low and the efficiency of converter is high. The soft switching operation of the proposed converter is verified by digital simulation and experimental results.

  • PDF

Switched Reluctance Motor 구동용 Converter의 무손실 Snubber (A lossless snubber for SRM converters)

  • 김원호;하성운;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.426-428
    • /
    • 1994
  • The effect of the snubber circuit is to control the voltage spikes applied across switching devices during turn-off. This paper describes a loss-less snubber of a converter for Switched Reluctance Motors. The feasibility of the snubber circuitry is experimentally verified using a laboratory prototype.

  • PDF

Soft Switching방식 고역률 강압형 컨버터 (Soft Switching High Power Factor Buck Converter)

  • 구헌회;조기연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.243-246
    • /
    • 1997
  • In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, a input capacitor can be small enough to filter input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn of of the switching device is a zero current switching(ZCS) and high power factor input is obtained. In addition, zero voltage switching(ZVS) at turn of is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontious conduction mode operation.

  • PDF

무손실 스너버를 이용한 부분공진 스위칭에 의한 고효율 승압형 단상 컨버터 (Boost $1\Psi$ converter of high efficiency by partial resonant switching using lossless snubber)

  • 서기영;곽동걸;전중함;이현우
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.315-322
    • /
    • 1998
  • 전력변환 시스템은 소형화, 경량화, 저잡음화를 실현하기 위하여 스위칭 주파수가 증대되어야 한다. 하지만 컨버터의 스위치들은 스위칭 스트레스와 많은 스위칭 전력손실을 동반한다. 이들 때문에 전력 시스템은 낮은 효율을 가져온다. 본 논문에서는 부분공진 모드에 의해 고효율의 승압형 단상 컨버터를 제안한다. 제안된 회로의 소자들은 소프트 스위칭으로 동작되며 이것의 제어기술은 일정 듀티 싸이클에서 동작되도록 스위치군을 간략화 하였다. 부분공진 회로는 승강압에 사용되는 인덕터와 무손실 스너버의 콘덴서를 사용한다. 또한, 이 회로는 종래의 회로가 가지는 스너버의 손실이 없는 스너버 콘덴서에 축적된 에너지를 입력전원 측으로 회생시킴으로서 효율증대의 장점이 있다. 그 결과 스위칭 손실이 매우 낮고 효율과 시스템 역률이 높게 된다. 제안된 컨버터는 전력용 스위칭 소자들이 사용되는 고출력의 응용분야에 가장 적합하다고 생각된다.

  • PDF

절연형 고효율 PFC AC-DC 컨버터에 관한 연구 (A Study on PFC AC-DC Converter of High Efficiency added in Electric Isolation)

  • 곽동걸;김상훈
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1349-1355
    • /
    • 2009
  • This paper is studied on a novel power factor correction (PFC) AC-DC converter of high efficiency by soft switching technique. The input current waveform in the proposed converter is got to be a sinusoidal form composed of many a discontinuous pulse in proportion to the magnitude of a ac input voltage under the constant switching frequency. Therefore, the input power factor is nearly unity and the control method is simple. The proposed converter adding an electric isolation operates with a discontinuous current mode (DCM) of the reactor in order to obtain some merits of simpler control, such as fixed switching frequency, without synchronization control circuit used in continuous current mode (CCM). To achieve the soft switching (ZCS or ZVS) of control devices, the converter is constructed with a new loss-less snubber for a partial resonant circuit. It is that the switching losses are very low and the efficiency of the converter is high, Particularly, the stored energy in a loss-less snubber capacitor recovers into input side and increases input current from a resonant operation. The result is that the input power factor of the proposed converter is higher than that of a conventional PFC converter. This paper deals mainly with the circuit operations, theoretical, simulated and experimental results of the proposed PFC AC-DC converter in comparison with a conventional PFC AC-DC converter.

새로운 PFC 스텝-업 컨버터의 입출력 파형해석 및 고조파분석에 관한 연구 (A Study on Input${\cdot}$Output Waveform Solutions and Harmonics Analyses for a Novel PFC Step-up Converter)

  • 곽동걸
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.622-628
    • /
    • 2005
  • This paper is given a full detail of mathematical analyses of input current and output voltage for a novel active type power factor correction (PFC) converter. These are compared with harmonics components of input current for a conventional PFC converter. The proposed PFC converter is constructed in using a new loss-less snubber circuit to achieve a soft switching of control device. Also the proposed converter for discontinuous conduction mode (DCM) eliminates the complicated circuit control requirement and reduces the size of components. The input current waveform in the proposed converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching. Therefore, input power factor is nearly unity and the control method is simple. Particularly, the stored energy of loss-less snubber capacitor is recovered with input side and increases input current from resonant operation. The result is that input power factor of the proposed converter is higher than that of conventional PFC converter. Some simulative results on computer and experimental results are included to confirm the validity of the analytical results.

유도 가열용 Half-Bridge 인버터 시스템의 신뢰성 향상 및 최적제어에 관한 연구 (A Study on the Reliability and Optimal Control of Half-Bridge Inverter for Induction Beating System)

  • 유상봉
    • 기술사
    • /
    • 제33권1호
    • /
    • pp.94-105
    • /
    • 2000
  • The purpose of this paper is to obtain the improved reliability and optimal control of the half-bridge inverter for induction heating system. Parasitic inductance components within the inverter circuit for induction heating including the loss-less turn-off snubber capacitor considerably affect stable operation and noise level of the system. This paper analyzes the effect of the inductance in detail and presents a new snubber configuration suitable for the half-bridge inverter to effectively reduce it. In the half-bridge inverter for induction heating the capacity of the loss-less snubber capacitor determines the switching losses because the zero voltage turn-on switching is used. However, the increase of the capacitor is limited by the system specifications, so that it is not easy work to reduce the switching loss. To effectively overcome the limitation, this paper introduces an active auxiliary resonant circuit suitable for the half-bridge inverter circuit, which operates actively according to the variation of load condition. It is also one of the most important study issues for the half-bridge inverter driven induction heater that the development of optimal control scheme considering varied load condition should be achieved. The control strategy ensures a very stable operation of overall inverter system and zero voltage turn-on switching irrespective of sensitive load parameter variations, in particular, even under the non-magnetic materials.

  • PDF

전류불연속 제어의 고효율 부스트 DC-DC 컨버터에 관한 연구 (A Study on High Efficiency Boost DC-DC Converter of Discontinuous Current Mode Control)

  • 곽동걸;김춘삼
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권9호
    • /
    • pp.431-436
    • /
    • 2005
  • This paper studies a novel boost DC-DC converter operated high efficiency for discontinuous current mode (DCM) control. The converter worked in DCM eliminates the complicated circuit control requirement, reduces a number of components, and reduces the used reactive components size. In the general DCM converter, the switching devices are turned-on the zero current switching (ZCS), and the switching devices must be switched-off at a maximum reactor current. To achieve the zero voltage switching (ZVS) at the switching turn-off, the proposed converter is constructed by using a new loss-less snubber circuit. Soft-switched operation of the proposed boost converter is verified by digital simulation and experimental results. A new boost converter achieves the soft-switching for all switching devices without increasing their voltage and current stresses. The result is that the switching loss is very low and the efficiency of boost DC-DC converter is high.