• Title/Summary/Keyword: Long-Term Variation

Search Result 708, Processing Time 0.028 seconds

Evaluation of Sejong Base as a Long Term Monitoring Site for Chromophoric Dissolved Organic Matter (CDOM) Variation in the Antarctic Ocean (남극해 유색 용존 유기물질의 장기 변동성 모니터링을 위한 세종 기지의 활용 가능성 평가)

  • Jeon, Mi-Hae;Park, Mi-Ok;Kang, Sung-Ho;Jeon, Misa
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.7
    • /
    • pp.898-905
    • /
    • 2019
  • As the positive feedback between the absorption of chromophoric dissolved organic matter (CDOM) and acceleration of ice melt can impact the aquatic biota and dynamic heat budget, long-term monitoring of the CDOM variation in the polar ocean is necessary. However, the monitoring of CDOM is not easy because of harsh weather and difficult access, especially in the Antarctic Ocean. Therefore, the purpose of this study was to find a suitable long-term monitoring site for CDOM variation; we selected Maxwell Bay and Marian Cove at Sejong Base and horizontal and vertical distributions of CDOM were measured. After a 72 hr time-series measurement test of the CDOM variation at Sejong Dock and Sejong Cape in Maxwell Bay, Sejong Dock was selected, as it does not haveland discharge effects. The seasonal variation of CDOM was evident and the average CDOM concentration of Maxwell Bay was comparable with the adjacent sea. The CDOM at Sejong Dock from February to November 2010 was the highest in the fall and winter and the lowest during spring and summer. Thus, based on our one-year CDOM data, we suggest that Sejong Dock in Maxwell Bay is suitable for long-term monitoring of CDOM as an indicator of photochemical and biological environmental change and an important factor in determining the heating budget in the Antarctic Ocean.

Application of Neural Network for Long-Term Correction of Wind Data

  • Vaas, Franz;Kim, Hyun-Goo
    • New & Renewable Energy
    • /
    • v.4 no.4
    • /
    • pp.23-29
    • /
    • 2008
  • Wind farm development project contains high business risks because that a wind farm, which is to be operating for 20 years, has to be designed and assessed only relying on a year or little more in-situ wind data. Accordingly, long-term correction of short-term measurement data is one of most important process in wind resource assessment for project feasibility investigation. This paper shows comparison of general Measure-Correlate-Prediction models and neural network, and presents new method using neural network for increasing prediction accuracy by accommodating multiple reference data. The proposed method would be interim step to complete long-term correction methodology for Korea, complicated Monsoon country where seasonal and diurnal variation of local meteorology is very wide.

  • PDF

LONG-TERM VARIATION OF THE SHUTTER DELAY TIME OF Y4KCAM OF THE CTIO 1.0 M TELESCOPE

  • Lee, Jae-Woo;Pogge, Richard
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.6
    • /
    • pp.289-293
    • /
    • 2016
  • We investigate the long-term spatial drift of the center and the temporal variation of the shutter delay time map of Y4KCam mounted on the CTIO 1.0 m telescope. We have collected shutter delay time maps over eight years as a part of our long-term survey program. We find that the center of the shutter delay time map can drift up to $450{\mu}m$, equivalent to ${\approx}30pixels$, on the CCD. This effect can result in a small amount of error in integration time without the proper shutter delay time correction, but it does not appear to cause any significant problems in photometric measurements. We obtain a mean shutter delay time of $69.1{\pm}0.8$ ms and find no temporal variation of the shutter delay time of Y4KCam over eight years, indicative of the mechanical stability of the shutter. We suggest that using a master shutter delay time correction frame would be sufficient to achieve high precision photometry, which does not exceed photometric errors ${\approx}1.7mmag$ across the CCD frame for exposure times longer than 1 s.

Characteristics of Wind Energy for Long-term Period (10 years) at Seoguang Site on Jeju Island (제주 서광지역에 대한 풍력에너지의 장기간 (10년) 특성)

  • Ko, Kyung-Nam;Kim, Kyoung-Bo;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.45-52
    • /
    • 2008
  • In order to clarify characteristics of variation in wind energy over a long-term period, an investigation was carried out at Seoguang site on Jeju island. The wind data for 10 years from Automatic Weather System (AWS) were analyzed for each year. The variation in the annual energy production (AEP) for the 2 MW wind turbine was estimated through statistical work. The result shows that the range of the yearly average wind speed at 15 m above ground level for 10 years was from -22.6% to +13.7%, which is wider range than that in Japan. The coefficient of variation for the AEP was 22.7%, which is about twice of that for the yearly average wind speed. Therefore, for estimating the wind energy potential accurately at a given site, the wind data should be analyzed over a long-term period based on the data from the meteorological station.

Studie8 on Long-Term Performance Evaluation of Geotextiles -for Filter and Drainage- (필터 및 배수용 토목섬유의 장기적 성능 평가에 관한 연구)

  • 권우남
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.130-139
    • /
    • 1993
  • In order to evaluate the long-term permeability performace of the geotextiles, for five different combination of geotextiles and soils the long-term column test method The results obtained are as follows; 1.The gradient range of the initial stage of the long-term permeability curves varied with respect to the soil types, while that of the final stage varied according to the interaction of the soil/geotextile system. 2.The time required for a given soil/geotextile system to reach a interactive stable stage was measured ahout 100 hours for the standard sand and 150 to 600 hours for the silty content soils, respectively. 3.There were no differences between the plain woven geotextile and the non-geotextile in the long-term permeability performance. 4.As the silt content increased, the long-term performance of the geotextiles decreased, and the limiting silt content was about 15%. 5.The thickness and area density of the geotextiles did not influence on the variation of the seepage quantities. 6.The ayerage slope and the transition time of the long-time flow curve were calculated. 7.In order to evaluate the mechanism of soil/geotextile system more perfectly, the gradient ratio test or the hydraulic conductivity test is required.

  • PDF

Application of Normality Test and Classification of Process Capability Index (공정능력지수의 유형화 및 정규성 검정의 응용)

  • Choe, Seong-Un
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.551-556
    • /
    • 2011
  • This research presents an implementation strategy of Process Capability Index (PCI) according to the types of process characteristics. The types of process feature are classified as four perspectives of variation range, time period, error position, and process stage. The paper examines short-term or long-term PCI, within or between variation, position of precision or accuracy, and inclusion of measurement or calibration stage. Moreover, the study proposes normality test of unilateral PCI.

  • PDF

Analysis of the Long-term Trend of PM10 Using KZ Filter in Busan, Korea (KZ 필터를 이용한 부산지역 PM10의 장기 추세 분석)

  • Do, Woo-gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.26 no.2
    • /
    • pp.221-230
    • /
    • 2017
  • To determine the effect of air pollution reduction policies, the long-term trend of air pollutants should be analyzed. Kolmogorov-Zurbenko (KZ) filter is a low-pass filter, produced through repeated iterations of a moving average to separate each variable into its temporal components. The moving average for a KZ(m, p) filter is calculated by a filter with window length m and p iterations. The output of the first pass subsequently becomes the input for the next pass. Adjusting the window length and the number of iterations makes it possible to control the filtering of different scales of motion. To break down the daily mean $PM_{10}$ into individual time components, we assume that the original time series comprises of a long-term trend, seasonal variation, and a short-term component. The short-term component is attributable to weather and short-term fluctuations in precursor emissions, while the seasonal component is a result of changes in the solar angle. The long-term trend results from changes in overall emissions, pollutant transport, climate, policy and/or economics. The long-term trend of the daily mean $PM_{10}$ decreased sharply from $59.6ug/m^3$ in 2002 to $44.6ug/m^3$ in 2015. This suggests that there was a long-term downward trend since 2005. The difference between the unadjusted and meteorologically adjusted long-term $PM_{10}$ is small. Therefore, we can conclude that $PM_{10}$ is unaffected by the meteorological variables (total insolation, daily mean temperature, daily mean relative humidity, daily mean wind speed, and daily mean local atmospheric pressure) in Busan.

The Development of Dynamic Model for Long-Term Simulation in Water Distribution Systems (상수관망시스템에서의 장기간 모의를 위한 동역학적 모형의 개발)

  • Park, Jae-Hong
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.4
    • /
    • pp.325-334
    • /
    • 2007
  • In this study, a long-term unsteady simulation model has been developed using rigid water column theory which is more accurate than Extended-period model and more efficient comparing with water-hammer simulation model. The developed model is applied to 24-hours unsteady simulation considering daily water-demand and water-hammer analysis caused by closing a valve. For the case of 24-hours daily simulation, the pressure of each node decreases as the water demand increase, and when the water demand decrease, the pressure increases. During the simulation, the amplitudes of flow and pressure variation are different in each node and the pattern of flow variation as well as water demand is quite different than that of KYPIPE2. Such discrepancy necessitates the development of unsteady flow analysis model in water distribution network system. When the model is applied to water-hammer analysis, the pressure and flow variation occurred simultaneously through the entire network system by neglecting the compressibility of water. Although water-hammer model shows the lag of travel time due to fluid elasticity, in the aspect of pressure and flow fluctuation, the trend of overall variation and quantity of the result are similar to that of water-hammer model. This model is expected for the analysis of gradual long-term unsteady flow variations providing computational accuracy and efficiency as well as identifying pollutant dispersion, pressure control, leakage reduction corresponding to flow-demand pattern, and management of long-term pipeline net work systems related with flowrate and pressure variation in pipeline network systems

A study on seasonal characteristics through long-term water quality monitoring in the Nakdong River Watershed (낙동강유역 장기 수질모니터링을 통한 계절적 특성분석 연구)

  • Kal, Byungseok;Park, Jaebeom;Kim, Seongmin;Shin, Sangmin;Jang, Soonja;Jeon, Minjae
    • Journal of Wetlands Research
    • /
    • v.24 no.4
    • /
    • pp.301-311
    • /
    • 2022
  • The purpose of this study is to analyze the seasonal characteristics of water quality using long-term water quality monitoring data. Seasonal characteristics of water quality were analyzed using monitoring data from 34 tributaries where long-term monitoring was performed in the Nakdong River system, and average data analysis of water quality, coefficient of variation analysis, and trend analysis were performed for seasonal analysis. For seasonal analysis, average data analysis of water quality, coefficient of variation analysis, and trend analysis were performed. As a result of the evaluation of the coefficient of variation, tributaries were larger than main streams, and BOD, T-P, and TOC were larger in autumn and T-N were larger in spring. Trend analysis was analyzed using Mann-Kendall and Sen's Slope. BOD, T-N, and T-P tended to decrease, but TOC had a lot to increase. Through this study, it was possible to evaluate the availability of long-term water quality monitoring data and analyze seasonal characteristics, and to analyze the stabilization period of water quality and changes in pollutant sources for watershed management.

The Long-term Variation Patterns of Atmospheric Mercury in Seoul, Korea from 1997 to 2002 (서울시 대기 중 수은농도의 장기변동 특성 1997~2002)

  • 김민영;김기현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.2
    • /
    • pp.179-189
    • /
    • 2003
  • The concentration of gaseous elemental mercury (Hg) was measured concurrently with relevant environmental parameters from Yang-Jae monitoring station in Seoul during Sept. 1997 to June 2002. Although data collection was disrupted for certain periods, the grand mean concentration of Hg for this five year period was found at 5.32 $\pm$ 3.53 ng m$^{-3}$ (N = 27,170). Because of short resolution of data acquisition, we were able to examine the temporal variability of Hg at varying time scale. The diurnal variability of Hg, when investigated for each of those five years, indicated consistently the dominance of nighttime over daytime. If examined at seasonal scale, Hg level was systematically higher during winter/spring than summer/fall period. The results of this short-term variability were best explained by the combined effects of such factors as meteorological conditions (formation of inversion layer and seasonal changes) and anthropogenic source processes. However, examination of long-term variation Pattern was much more complicated to explain. Thus, extension of our study is needed to diagnose the future direction in long-term trend of Hg behavior.