• 제목/요약/키워드: Location analysis

검색결과 7,088건 처리시간 0.038초

주파수영역 패널기법을 사용한 유도무기형태 동체에 장착된 엇회전식 프롭팬의 공력해석 (Aerodynamic Analysis of Counter-Rotating Propfans Around a Missile-Like-Body Using a Frequency Domain Panel Method)

  • 조진수
    • 대한기계학회논문집
    • /
    • 제18권6호
    • /
    • pp.1590-1597
    • /
    • 1994
  • The aerodynamic analysis of a $6{\times}6$ counter-rotating propfan around a missile-like-body has been completed analytically using a frequency domain panel method. The present method requires Fourier transformation of flow field around the propfan in computing the velocities normal to the propfan lifting surfaces. The aerodynamic performance curve is determined by angle of attack and nonuniform inflow conditions. The inflow conditions result from the variations of missile flight speed, angle of attack, propfan location relative to control surfaces and control surface deflection angle. The two cases of propfan location relative to control surface, front and behind, are analyzed and the aerodynamic results are presented.

우편물 자동순로구분시스템 운영방안의 평가 (Quantitative Evaluation and Economy Analysis for the Operation Policies of Automatic Mail Reading and Sorting System)

  • 임준묵;남윤석;강진규;임길택;왕승진;송재관;서재준;최한용
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2003년도 춘계공동학술대회
    • /
    • pp.1020-1027
    • /
    • 2003
  • The development of an automatic delivery sorter requires enormous cost and time, and actually it is a key business which gains control of the future of postal service for national economy. In this paper, we select executive alternatives considering the restrictive conditions both in physically and technically such as installation location, OCR location, and the types of VCS. Then, we evaluated selected alternatives through the analysis of a cost and a performance. And we also performed economy analysis reflecting on the qualitative factors.

  • PDF

A Numerical Study on the Effect of DVI Nozzle Location on the Thermal Mixing in RVDC

  • Kang, Hyung-Seok;Cho, Bong-Hyun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.283-288
    • /
    • 1996
  • Direct safety injection into the reactor vessel downcomer annulus(DVI) is a fundamental feature of the KNGR(Korean Next Generation Reactor) four-train safety injection system. The numerical analysis of thermal mixing of ECC(Emergency Core Cooling) water through DVI with the water in the RVDC(Reactor Vessel Downcomer) annulus has been performed, in order to study the impact of nozzle location on the pressurized thermal shock and safety analysis. The results of this study show that the thermal mixing due to the natural circulation induced by the limiting accident conditions is sufficient to prevent temperature in the RVDC from dropping to the level of concern for PTS. When the DVI nozzle is located right above the cold leg, the temperature distribution at the outlet of flow field is most uniform. The tool used for numerical analysis is CFDS-FLOW3D.

  • PDF

Frequency analysis of beams with multiple dampers via exact generalized functions

  • Failla, Giuseppe
    • Coupled systems mechanics
    • /
    • 제5권2호
    • /
    • pp.157-190
    • /
    • 2016
  • This paper deals with frequency analysis of Euler-Bernoulli beams carrying an arbitrary number of Kelvin-Voigt viscoelastic dampers, subjected to harmonic loads. Multiple external/internal dampers occurring at the same position along the beam axis, modeling external damping devices and internal damping due to damage or imperfect connections, are considered. The challenge is to handle simultaneous discontinuities of the response, in particular bending-moment/rotation discontinuities at the location of external/internal rotational dampers, shear-force/deflection discontinuities at the location of external/internal translational dampers. Following a generalized function approach, the paper will show that exact closed-form expressions of the frequency response under point/polynomial loads can readily be derived, for any number of dampers. Also, the exact dynamic stiffness matrix and load vector of the beam will be built in a closed analytical form, to be used in a standard assemblage procedure for exact frequency response analysis of frames.

인공신경망을 이용한 산사태 취약성 분석 (Landslide Susceptibility Analysis Using Artificial Neural Networks)

  • 이사로;류주형;민경덕;원중선
    • 자원환경지질
    • /
    • 제33권4호
    • /
    • pp.333-340
    • /
    • 2000
  • The purpose of this study is to develop landslide susceptibility analysis techniques using artificial neural network and apply the newly developed techniques for assessment of landslide susceptibility to study areas, Yongin. Landslide locations detected from interpretation of aerial photo and field survey, and topographic, soil and geological maps of the Yongin area were collected. The data of the locations of land-slide, slope, soil texture, topography and lithology were constructed into spatial database using GIS. Using the factors, landslide susceptibility was analyzed by artificial neural network methods. The results of the analysis were verified using the landslide location data. The validation results showed satisfactory agreement between the susceptibility map and landslide location data.

  • PDF

AHP를 활용한 물류센터 입지 선정 요인 분석에 관한 연구 (A Study on the Factor Analysis of Distribution Center Location Selection Using Analytic Hierarchy Process)

  • 양광모
    • 대한안전경영과학회지
    • /
    • 제13권2호
    • /
    • pp.129-135
    • /
    • 2011
  • Logistics parks make profits using the efficiency of time and space. Such logistics parks play an important role in a corporation creating operating profits as well as acting as a method of alternative investment for individuals. Logistics parks no longer simply store materials, but have become a place that plays an important role in various areas of corporate and individual activities, and thus the analysis of the selection of the location of logistics parks and the related characteristics is extremely important. The estimation model is established by the weights for industry derived from AHP(Analytic Hierarchy Process).

On the fundamental period of infilled RC frame buildings

  • Asteris, Panagiotis G.;Repapis, Constantinos C.;Cavaleri, Liborio;Sarhosis, Vasilis;Athanasopoulou, Adamantia
    • Structural Engineering and Mechanics
    • /
    • 제54권6호
    • /
    • pp.1175-1200
    • /
    • 2015
  • This paper investigates the fundamental period of vibration of RC buildings by means of finite element macro-modelling and modal eigenvalue analysis. As a base study, a number of 14-storey RC buildings have been considered "according to code designed" and "according to code non-designed". Several parameters have been studied including the number of spans; the span length in the direction of motion; the stiffness of the infills; the percentage openings of the infills and; the location of the soft storeys. The computed values of the fundamental period are compared against those obtained from seismic code and equations proposed by various researchers in the literature. From the analysis of the results it has been found that the span length, the stiffness of the infill wall panels and the location of the soft storeys are crucial parameters influencing the fundamental period of RC buildings.

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • 오규환;강파;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF

EDISON OPT 평면요소를 이용한 고 세장비 날개에 대한 선형, 비선형 비교연구 및 추가구조물 위치 최적화 (Study on High Aspect Ratio Wing and Optimization of Substructure Location by Using EDISON OPtimal Triangle membrane(Linear and Non-linear analysis) - Static)

  • 이다운;홍윤표;신상준
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제5회(2016년)
    • /
    • pp.262-267
    • /
    • 2016
  • In this paper, to design Human Powered Aircraft(HPAC) with high aspect ratio wing which behave with large displacement under lift distribution causing a failure itself, then steel wire has been designed to prevent its failure. unit load method is used to calculate reaction force on wire and Optimal Triangle(OPT) membrane is employed to analyze its main wing spar with large displacement. EDISON CSD solver, linear static analysis and co-rotational nonlinear static anaysis both using OPT membrane produce behaviors of beam for each case of wire location about main wing spar, and aerodynamic coefficient also, by using aerodynamic analysis tool.

  • PDF

분포정수회로 해석 방법을 이용한 지중선로 고장점 추정 알고리즘 (A Novel Algorithm of Underground Cable Fault Location based on the analysis of Distributed Parameter Circuit)

  • 이덕수;양하;최면송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.24-27
    • /
    • 2004
  • This paper proposes a new algorithm of underground cable fault location based on the analysis of distributed parameter circuit. The proposed method firstly makes voltage and current equations for each of cores and sheathes respectively, and then establishes an equation of the fault distance according to the analysis of the fault conditions. Finally the solution of this equation is calculated by Newton-Raphson iteration method. The effectiveness of this proposed algorithm has been proven through PSCAD/EMTDC simulations.

  • PDF