• 제목/요약/키워드: Loading Distribution Method

검색결과 560건 처리시간 0.031초

Comparative Analysis of Stress Distribution in Composite Resin Brackets with Metal Slot of Permanent Maxillary Central Incisor Using the Finite Element Method: A Pilot Study

  • Im, Jae-Jung;Song, Jae-Joon;Kim, Nan-Hee;Heo, Jin-Young;Jung, Gyu-Un;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Korean Dental Science
    • /
    • 제4권2호
    • /
    • pp.46-51
    • /
    • 2011
  • Purpose: For aesthetic reasons, composite resin brackets are widely used. However, related studies are rare. This pilot study sought to compare the stress distributions in two commercially available composite resin brackets with metal slot. Materials and Methods: Two commercially available resin brackets -- full-metal slot resin bracket (fSRB) and partial-metal slot resin bracket (pSRB) with straight wire appliance dimension of $0.022{\times}0.028$ in -- were selected. In each bracket, 3-dimensional finite element models were constructed, and stress level was evaluated using finite element analysis. By loading the tipping force and torsion moment, which are similar to those applied by the stainless steel rectangular wire ($0.019{\times}0.025$ -in), stress distributions were calculated, and von Mises stress values were obtained. Results: In pSRB and fSRB, the stress value of the torque moment was much higher than that of the tipping force. The pSRB showed higher stress value than fSRB in both tipping force and torque moment because of the difference in size and configuration of the metal frame inserted into the slot. More stress was also found to be concentrated on the slot area than the wing area in fSRB. Conclusion: The slot form of fSRB was found to be more resistant to the stress of tipping and torque than the slot form of pSRB. In addition, the slot areas -- rather than the wing areas -- of the bracket showed breakage susceptibility. Therefore, resistance to the torque moment on the slot area should be considered in bracket design.

이프리플라본을 함유한 생분해성 미립구의 제조와 특성분석 (Preparation and Characteristics of Ipriflavone-Loaded PLGA Microspheres)

  • 이진수;강길선;이종문;신준현;정제교;이해방
    • 폴리머
    • /
    • 제27권1호
    • /
    • pp.9-16
    • /
    • 2003
  • 골다공증 치료제 이프리플라본 (IP)은 조골세포의 분화와 증식을 자극하고 에스트로겐의 존재로 칼시토닌 분비를 강화한다. 조절 가능한 생분해성과 생체적합성으로 인하여 락타이드-글라이콜라이드 공중합체 (PLGA)는 약물방출조절을 연구하는데 가장 적합한 고분자중의 하나이다. 본 연구에서 IP가 함유된 PLGA 미립구는 일반적인 O/W 용매 증발법으로 제조하였으며, 미립구의 크기는 5~200 $mu extrm{m}$의 범위에 있었다. 미립구의 형태는 SEM으로 관찰하였고, 생체외 방출실험에서 IP 방출량은 HPLC로 분석 하였다. 젤라틴 및 PVA등의 유화제 사용으로 가장 높은 약물 포접율을 얻을 수 있었다. 미립구의 형태, 크기 및 약물 방출 패턴은 PLGA의 분자량 (8, 20, 33 및 90 kg/mol), 고분자용액의 농도 (2.5, 5, 10 및 20%), 유화제의 종류 (PVA, gelatin 및 Tween 80), 초기 약물 함유량 (5, 10, 20 및 30%) 및 교반속도 (250, 500 및 1000 rpm) 등과 같은 여러 제조 변수들에 의하여 조절할 수 있음을 알 수 있었다. 생체외 방출실험에서 IP 방출은 제조조건을 조절함으로써 거의 영차방출 형태로 30일 이상으로 지속적이었다 또한, XRD와 DSC로 IP 함유 PLGA 미립구의 물리화학적인 성질을 조사하여 방출메카니즘을 고찰하였다.

축하중 분포 변화가 콘크리트 포장의 공용성 예측결과에 미치는 영향 연구 (Influence on Predicted Performance of Jointed Concrete Pavement with Variations in Axle Load Spectra)

  • 이경배;권순민;이재훈;손덕수
    • 한국도로학회논문집
    • /
    • 제16권1호
    • /
    • pp.11-19
    • /
    • 2014
  • PURPOSES : The purpose of this article is to investigate the predicted life of jointed concrete pavement (JCP) with two variables effecting on axle load spectra (ALS). The first variable is different data acquisition methods whether using high-speed weigh-in-motion (HS-WIM) or not and the other one is spectra distribution due to overweight enforcement on main-lane of expressway using HS-WIM. METHODS : Three sets of ALS had been collected i) ALS provided by Korea Pavement Research Program (KPRP), which had been obtained without using HS-WIM ii) ALS collected by HS-WIM before the enforcement at Kimcheon and Seonsan site iii) ALS collected after the enforcement at the same sites. And all ALS had been classified into twelve vehicle classes and four axle types to compare each other. Among the vehicle classes, class 6, 7, 10 and 12 were selected as the major target for comparing each ALS because these were considered as the primary trucks with a high rate of overweight loading. In order to analyze the performance of JCP based on pavement life, fatigue crack and International Roughness Index (IRI) were predicted using road pavement design program developed by KPRP and each ALS with same annual average daily traffic (AADT) was applied to design slab thickness. RESULTS : Comparison ALS of KPRP with those of HS-WIM shows that the ALS of KPRP has a low percentage of heavy spectra such as 6~9 tonnes for single axle, 18~21 tonnes for tandem axle and 27~30 tonnes for tridem axle than other two ALS of HS-WIM in most vehicle classes and axle types. It means that ALS of KPRP was underestimated. And after the enforcement, percentage of heavy spectra close to 10 tonnes per an axle are lowered than before the enforcement by the effect of overweight enforcement because the spectra are related to overweight regulation. Prediction results of pavement life for each ALS present that the ALS of HS-WIM collected before the enforcement makes the pavement life short more than others. On the other hand, the ALS of KPRP causes the longest life under same thickness of slab. Thus, it is possible that actual performance life of JCP under the traffic like ALS of HS-WIM could be short than predicted life if the pavement was designed based on ALS provided by KPRP. CONCLUSIONS : It is necessary to choose more reliable and practical ALS when designing JCP because ALS can be fairly affected by acquisition methods. In addition, it is important to extend performance life of the pavement in service by controlling traffic load such as overweight enforcement.

다짐도에 따른 지중파형강판의 거동에 대한 원심모형실험 (Centrifugal Model Test on Behavior of Underground Corrugated Steel Plate with Compaction Degree)

  • 허열;권선욱;김홍종;배우석
    • 한국지반환경공학회 논문집
    • /
    • 제12권10호
    • /
    • pp.83-90
    • /
    • 2011
  • 본 연구에서는 고성토 구간 파형강판 수로암거의 대표단면을 대상으로 뒤채움부의 다짐도에 따른 원형 연성지중 암거에 작용되는 수직토압 분포를 파악하기 위해 원심모형실험을 실시하였다. 모형실험은 뒤채움부의 다짐도를 80, 85, 90, 95%로 변화시키면서 현장의 상사성을 고려하여 53g-level의 중력수준에서 수행하였다. 실험결과, 연성거동을 하는 파형강판 상부의 아칭효과에 의한 하중감소계수는 AISI(2002) 설계법에서 규정한 뒤채움 다짐도에 따른 하중감소계수와 거의 일치하였다. 파형강판 상부에서 측정된 수직토압은 다짐도가 증가함에 따라 선형적으로 감소하였으며, 뒤채움부의 다짐도가 클수록 아칭효과에 의한 파형강판 상부의 상재하중 감소가 크게 발휘된다는 것을 확인할 수 있었다. 파형강판 상부에서 발생한 아칭효과에 의해 감소한 하중이 파형강판측면 뒤채움부(EP 1)와 뒤채움부 외부(EP 3)로 전이되는 것으로 나타났다.

중간 지대치가 존재하는 고정성 국소의치에서 보철물 설계 및 치조골 상태가 응력분포에 미치는 영향 (Effect of prosthetic designs and alveolar bone conditions on stress distribution in fixed partial dentures with pier abutments)

  • 조욱;김창섭;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.328-334
    • /
    • 2009
  • 연구목적: 하악 제 1 소구치 및 제 1 대구치가 결손 되어 중간 지대치를 갖는 5 본 고정성 국소의치에서 비고정형 어태치먼트의 설계 유무 및 지대치의 지지골 상태에 따른 변위 및 응력분포의 차이를2 차원 유한요소분석을 통해 비교하여 보고자 하였다. 연구 재료 및 방법: 5 본 고정성 국소의치는 일체형과 분할형으로 구분하였으며, 분할형에는 제 2 소구치와 제 1 대구치 사이에 비고정형 어태치먼트를 설계하였다. 지지골은 모두 정상인 경우와 세 개 지대치중 한 개의 지대치에서 임상적 치관 대 치근 비율이 6 : 4 정도까지 골 흡수가 일어난 세 가지 경우를 가정하여 총 네 가지의 지지골 상태를 설정하였다. 제 1 소구치와 제 1 대구치 가공치 중앙에 각각 150 N의 수직 분산하중과, 제 1 대구치 가공치 중앙에 300 N의 수직 집중하중을 가하였다. 결과: 일체형과 분할형 고정성 국소의치 모두에서 하중 시 하방 변위를 보였다. 분할형 고정성 국소의치에서 일체형보다 전방 지대치 지지골에서의 응력은 감소하였으나 중간 및 후방 지대치 지지골에서의 응력은 증가하였다. 지대치의 치조골 흡수가 있는 경우 해당 지대치의 지지골에 국소적인 응력 증가가 나타났다. 결론: 중간 지대치를 갖는 고정성 국소의치를 설계할 경우 유지 장치의 유지 능력과 지대치의 지주 상태 그리고 어태치먼트의 사용에 대한 주의 깊은 고찰이 필요하겠다.

골 이식술 후 Osstem Implant (US II Plus/GS II)의 다기관 임상연구 (A multicenter clinical study of installed US II Plus/GS II Osstem implants after bone graft)

  • 정광;오철중;하지원;국민석;박홍주;오희균;김수관;김영균;김우철
    • 대한치과의사협회지
    • /
    • 제50권12호
    • /
    • pp.743-754
    • /
    • 2012
  • urpose : The purpose of this study was to evaluate the US II plus/GS II Osstem$^{(R)}$ implants through the study for the clinical success rate during the installation of the Osstem¢Á implants after bone graft. Materials and Methods : This study was researched in the 4 medical institutions: Chonnam National University, Chosun University, Bundang Seoul National University Hospital, and FM dental clinic from May, 2002 to September, 2009. Based on the total number of 60 patients whose treatment was the installation of the US II plus/GS II Osstem¢Á implants after bone graft, we evaluated success rate of implants. We analysis the distribution of patient's age and gender, edentulous area, bone type, fixture length and diameter, installation and loading time, donor site, bone graft material and method, antagonistic teeth, and survival and success rate. From these analyses we got the following results. Results : 1. In this study, the total number of patients who have been installed with US II plus implant was 27, and total of 52 implants were installed. The average age was 38.9, with 16 male, and 11 female patients. 2. The total number of patients who have been installed with GS II implant was 33, and total of 54 implants were installed. The average age was 49.7, with 24 male, and 9 female patients. 3. As for bone graft method, either autogenous bone or a mix of autogenous and heterogenous bone was used(88.4%) for US II plus. Chin, iliac, and Maxillary tuberosity were the donor sites for autogenous bone graft, and onlay method of bone graft was performed. 4. Allogenic bone or a mix of autogenous and heterogenous bone was used(77.8%) for GS II. Chin, ramus, and tibia were the donor sites for autogenous bone graft, and GBR method of bone graft was performed. 5. The duration from the installation of implants to setting of final prosthesis was average of 16 months and 10 months for US II plus and GS II respectively. Also, the final follow up period was average of 31 months and 28 months respectively. During this period, one GS II implant was removed from 1 patient due to failure of early osteointegration. 6. The survival rates were 100% and 98.1%, and success rates were 94.2% and 94.4% for US II plus and GS II implant respectively. Conclusion : On the evaluation of our clinical study, both US II plus and GS II Osstem¢Á implants showed the excellent clinical results after bone graft.

Glass fiber 강화 복합레진을 사용한 3본 고정성 국소의치의 개념 설계 연구 (Conceptual Design of the Three Unit Fixed Partial Denture with Glass Fiber Reinforced Hybrid Composites)

  • 나경희;이규복;조광헌
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.145-155
    • /
    • 2002
  • 본 연구에서는 knitted glass fabric 강화 레진에 대한 치과보철소재로서의 적용가능성을 평가하기 위한 목적으로, 가장 높은 수준의 교합하중이 작용하게 되는 구치부 3본 고정성국소의치에 이 재료를 사용하는 경우에 대해 해석을 수행하였다. 우선 구치부3본 고정성국소의치에 대해 knitted glass fabric 강화 레진을 적용한 두 가지 설계 개념을 상정하였고, 각 설계형상에 대한 유한요소해석을 하였다. 강도 평가를 위해서75N의 생리적인 반복 수직 교합 하중 조건을 부여, 보철물에 유도되는 국소응력을 피로강도측면에서 고찰하였다. 각각의 설계에는 knitted glass fabric을 모재로 하고 보강재로 unidirectional 형의 glass 복합재가 사용되었다. 본 연구에서 개념설계 된 두 가지의 3본 고정성국소의치는 수직 교합 하중 75N 에 대해 충분한 강성과 강도를 가진 것으로 분석되었다. 가공치와 knitted caps사이의 연결 부위에서 국소적인 응력 집중이 관찰되었으나 그 크기는 재료의 피로강도 범위 이내였으며 국소적인 설계변경을 통하여 응력분포를 더욱 개선할 수 있을 것으로 추정하였다. 본 연구를 통해 knitted glass fabric 은 새로운 치과 보철 소재로서의 그 가능성이 기대된다.

CT상의 HU 수치에 따른 상악골 전방견인 효과의 유한요소 분석 (Stress distribution following face mask application using different finite element models according to Hounsfield unit values in CT images)

  • 정동화
    • 대한치과교정학회지
    • /
    • 제36권6호
    • /
    • pp.412-421
    • /
    • 2006
  • 유한요소분석의 결과는 표현된 물성과 구조, 유한요소의 밀도, 그리고 경계 및 하중조건에 의존하게 된다. 상악견인장치의 사용에 있어 상악의 실제 구조와 밀도를 물성으로 반영하여 새로이 개선된 유한요소 모텔과 기존의 방식을 따른 유한요소 모델을 비교하였다. 연구에서 대상이 된 환자는 13세 6개월된 남자 환자였으며 전산화단층사진 촬영으로 얻은 DICOM 영상정보를 개인용 컴퓨터로 옮긴 후 3차원 영상프로그램을 이용하여 3차원 입체영상을 제작하였다. CT상에서 Gray scale을 표현하는 수치인 Hounsfield unit (HU)값을 이용하여 24단계의 물성을 가진 모델(모델1)과 고전적인 방법에 따라 2가지의 물성만을 가진 모델(모델2)을 구성하였다. FH plane하방 $45^{\circ}$ 방향에서 500g의 힘으로 견인하여 다음과 같은 결론을 얻었다. 관골하 능선 후방에 있는 상악골의 부위는 전방부보다 더 넓고, 낮은 밀도를 가진 해면골로 구성되어 있었다. 따라서 같은 견인력을 적용하였음에도 24개의 물성을 가진 모델1의 제1소구치가 모델2의 제1소구치보다 전방과 하방으로의 더 많은 이동이 가능했다. 이에 대한 반응으로, 상악골은 시상면과 전두면상에서 휘어졌고, 소구치를 포함한 전방부위의 상악골이 아래 방향으로 움직이게 되었다. 고전적인 방법의 2개의 물성을 이용한 모델의 경우, 제1소구치 골 주위에서의 전하방 이동이 작게 나타났으며 상악결절 부위에서는 상방으로의 이동양상을 보여 결과적으로 이 모델에서는 상악 제1대구치의 전방을 중심으로 시계방향의 회전을 보여 주었다. 따라서 물성 지정의 차이에 따라 유한 요소분석의 결과에 차이를 보였으며 HU 값을 이용했을 때 좀 더 역학적 구조가 잘 표현해 내리라 고려된다.drilling microscrew implants가 더 많은 골접촉을 보였으나 5주에서는 두 군사이에 차이가 관찰되지 않았다. 이 결과는 두 방법이 모두 microscrew implant의 식립에 사용될 수 있음을 시사하나 self-tapping microscrew implants의 경우 초기에는 약한 힘을 가하는 것이 좋을 것으로 생각된다. 와이어에서 열처리를 시행하여 굴곡을 부여한 실험군은 열처리만 시행한 실험군과 열처리를 시행하지 않은 대조군에 비해 부하-변위 곡선이 상방 이동되었으며, 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군에서 가장 높은 부하-변위 곡선을 나타냈다. $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 와이어에서 $A_f$ 온도는 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군에서 가장 낮게 관찰되었고 열처리를 시행하여 굴곡을 부여한 실험군, 열처리만 시행한 실험군 그리고 열처리를 시행하지 않은 대조군 순으로 높게 관찰되었다. 이상의 결과를 종합할 때, 임상에서 니켈-티타늄 합금 와이어에 굴곡을 부여하기 위해 열처리하는 경우 초탄성 특성은 유지될 수 있으나, 부하-변위 곡선의 상방 증가가 나타나므로, 와이어에 의한 교정력이 증가될 수 있음에 유의하여야 한다. $day^{-1}$인 인공습지), scenario 2(면적 4.2ha인 저류지)가 각각 연평균 6.9%, 4.8%, 7.1%의 감소를 보였다. TN은 4.7%, 3.4%, 13.4%의 삭감율을 나타내었으며, TP는 5.6%, 3.9%, 7.3%의 삭감율을 나타내었다. 본 연구에서는 적용하지 못하였으나, 인공습지와 저류지의 적절한

Development of High Intensity Focused Ultrasound (HIFU) Mediated AuNP-liposomal Nanomedicine and Evaluation with PET Imaging

  • Ji Yoon Kim;Un Chul Shin;Ji Yong Park;Ran Ji Yoo;Soeku Bae;Tae Hyeon Choi;Kyuwan Kim;Young Chan Ann;Jin Sil Kim;Yu Jin Shin;Hokyu Lee;Yong Jin Lee;Kyo Chul Lee;Suhng Wook Kim;Yun-Sang Lee
    • 대한방사성의약품학회지
    • /
    • 제9권1호
    • /
    • pp.9-16
    • /
    • 2023
  • Liposomes as drug delivery system have proved useful carrier for various disease, including cancer. In addition, perfluorocarbon cored microbubbles are utilized in conjunction with high-intensity focused-ultrasound (HIFU) to enable simultaneous diagnosis and treatment. However, microbubbles generally exhibit lower drug loading efficiency, so the need for the development of a novel liposome-based drug delivery material that can efficiently load and deliver drugs to targeted areas via HIFU. This study aims to develop a liposome-based drug delivery material by introducing a substance that can burst liposomes using ultrasound energy and confirm the ability to target tumors using PET imaging. Liposomes (Lipo-DOX, Lipo-DOX-Au, Lipo-DOX-Au-RGD) were synthesized with gold nanoparticles using an avidin-biotin bond, and doxorubicin was mounted inside by pH gradient method. The size distribution was measured by DLS, and encapsulation efficiency of doxorubicin was analyzed by UV-vis spectrometer. The target specificity and cytotoxicity of liposomes were assessed in vitro by glioblastoma U87mg cells to HIFU treatment and analyzed using CCK-8 assay, and fluorescence microscopy at 6-hour intervals for up to 24 hours. For the in vivo study, U87mg model mouse were injected intravenously with 1.48 MBq of 64Cu-labeled Lipo-DOX-Au and Lipo-DOX-Au-RGD, and PET images were taken at 0, 2, 4, 8, and 24 hours. As a result, the size of liposomes was 108.3 ± 5.0 nm at Lipo-DOX-Au and 94.1 ± 12.2 nm at Lipo-DOX-Au-RGD, and it was observed that doxorubicin was mounted inside the liposome up to 52%. After 6 hours of HIFU treatment, the viability of U87mg cells treated with Lipo-DOX-Au decreased by around 20% compared to Lipo-DOX, and Lipo-DOX-Au-RGD had a higher uptake rate than Lipo-DOX. In vivo study using PET images, it was confirmed that 64Cu-Lipo-DOX-Au-RGD was taken up into the tumor immediately after injection and maintained for up to 4 hours. In this study, drugs released from liposomes-gold nanoparticles via ultrasound and RGD targeting were confirmed by non-invasive imaging. In cell-level experiments, HIFU treatment of gold nanoparticle-coupled liposomes significantly decreased tumor survival, while RGD-liposomes exhibited high tumor targeting and rapid release in vivo imaging. It is expected that the combination of these models with ultrasound is served as an effective drug delivery material with therapeutic outcomes.

자동차 조립 작업자들에서 상지 근골격계의 인간공학적 작업평가(Rapid Upper Limb Assessment) 결과와 자각증상과의 연관성 (The Relation Between Work-Related Musculoskeletal Symptoms and Rapid Upper Limb Assessment(RULA) among Vehicle Assembly Workers)

  • 김재영;김해준;최재욱
    • Journal of Preventive Medicine and Public Health
    • /
    • 제32권1호
    • /
    • pp.48-59
    • /
    • 1999
  • 본 연구는 Rapid Upper Limb Assessment(RULA)를 이용하여 자동차 조립작 업에 대한 인간공학적 작업평가를 하고, 이 결과와 작업관련 상지 근골격계 질환의 자각증상율 및 작업특성 변수들의 연관성을 분석함으로써, RULA결과가 관련 신체부위의 통증이나 불편함으로 보고되는 근골격계 부하의 좋은 지표가 될 수 있는지, RULA평가체계를 이용하여 작업 위험도가 적합한지 여부를 평가할 수 있는가를 보고자 하였다. 자동차 제조업 작업자 314명을 대상으로 근골격계질환 자각증상설문과 RULA를 이용한 작업평가를 하였으며, 다음과 같은 결과를 얻었다. 1. NIOSH의 작업관련 근골격계 질환의 감시기준(surveillence criteria)에 따라 자각증상을 조사한 결과, 연구대상자 중 목 32.8%, 어깨 26.4%, 팔 10.5%, 손 29.3%, 허리 41.4%였으며, 한가지 이상 의 증상을 보이는 경우는 62.4%의 분포를 보였다. 2. 품질관리부에 비해 조립부서 작업자 틀이 전체 증상과 어깨, 허리, 팔 및 손부 위 증상에서 더 높은 유증상률을 보였다(p<0.05). 3. 부서별 RULA를 이용한 작업평가 결과, 서브/조립반과 의장반의 공정이 높은 위험점수를 보였다. 전체 조립부서에 대한 평가결과 적합한 작업은 3.02%였고, 62.8%가 부적합한 작업으로 작업전환이나 중재조치가 필요한 경우였다. 자각증상과 RULA를 이용한 작업평가 결과를 비교한 결과 RULA점수가 클수록 자각증상율이 높음을 보였다.(p<0.05) 4. RULA평가지표와 자각증상사이의 관련성을 보기 위하여, RULA지표와 기타 작업관련요인들을 독립변수로, 자각증상유무를 종속변수로 하여 다중 로지스틱 회귀분석을 실시하였다. 최종적으로 증상유무를 가장 잘 설명하는 회귀모형에 대한 분석결과는 다음과 같다. 모든 증상군에 대해서는 반복작업(OR 2.183), 진동공구 사용(OR 2.775)과 총 위험도 점수(OR 2.250); 목 부위 증상군에서는 상완의 자세점수(OR 1.786), 상완 및 손부 위의 총점수(OR 1.634) ; 어깨 증상군은 상지의 근사용(OR 3.076), 상완 및 손부 위의 총점수(OR 1.798); 어깨와 목 부위를 합한 증상군은 상완 및 손부위의 총점 수(OR 1.715)와 상지의 근사용 점수(OR 2.057); 팔 증상군에서는 상지의 근사용 점수(OR 10.662) ; 손 부위 증상군에 대해서는 손목의 자세/손목 비틀림 지표 (OR 2.068)와 상지의 근사용 점수(OR 2.215); 허리부위 증상군에서는 하지의 근사용 점수(OR 2.601)가 통계적으로 유의한 지표였다.(p<0.05) 이상의 결과에서 작업관련 상지근골격계 자각증상과 RULA 점수사이에는 연관성이 있음이 관찰되었다. 이는 RULA가 직업성 질환을 유발할 수 있는 근골격계 부하에 폭로된 작업자들을 평가하는, 일차적인 작업 위험도 평가도구(Screening tool)로서 쓰일 수 있음을 말해준다. 다만 향후 RULA 사용에 있어서 상지(upper limb)와 허리부위(back)의 평가를 구분하고, 기타 다른 작업관련 요인들에 대한 평가체계를 보완하는 것이 필요하다.

  • PDF